• 제목/요약/키워드: arcing

검색결과 218건 처리시간 0.026초

온도센서를 이용한 전력설비의 온라인 상태 감시 (On-Line Condition Monitoring of Electrical Equipment Using Temperature Sensor)

  • 최용성;김선재;김영민;송환기;이경섭
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.202-208
    • /
    • 2008
  • Condition monitoring technologies allow achieving this goal by minimizing downtime through the integrated planning and scheduling of repairs indicated by condition monitoring techniques. Thermal runaways induced by conduction problems deteriorate insulating material and cause disruptive dielectric discharges resulting in arcing faults. Therefore, having the ability to directly measure the temperature of the contacts while in service will provide more information to determine the true condition of the equipment. It allows connective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on -line condition monitoring of energized equipment is applicable both as stand alone system and with an interface for power quality monitoring system. The paper presents the results of wireless temperature monitoring: of electrical equipment at a power plant.

고속 적응자동재폐로를 위한 사고거리추정 및 사고판별에 관한 개선된 양단자 수치해석 알고리즘 (An Improved Two-Terminal Numerical Algorithm of Fault Location Estimation and Arcing Fault Detection for Adaptive AutoReclosure)

  • 이찬주;김현홍;박종배;신중린;조란 라도예빅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권11호
    • /
    • pp.525-532
    • /
    • 2005
  • This paper presents a new two-terminal numerical algorithm for fault location estimation and for faults recognition using the synchronized phaser in time-domain. The proposed algorithm is also based on the synchronized voltage and current phasor measured from the assumed PMUs(Phasor Measurement Units) installed at both ends of the transmission lines. Also the arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records obtained by transient recorder. From the calculated arc voltage amplitude it can make a decision whether the fault is permanent or transient. In this paper the algorithm is given and estimated using DFT(discrete Fourier Transform) and the LES(Least Error Squares Method). The algorithm uses a very short data window and enables fast fault detection and classification for real-time transmission line protection. To test the validity of the proposed algorithm, the Electro-Magnetic Transient Program(EMTP/ATP) is used.

아크계측 및 응용연구를 위한 LC공진회로 전류원 구축 (Installation of Current Source Using LC Resonance Circuit for Arcing Experiments)

  • 강종성;박홍태;최원준;이방욱;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2113-2115
    • /
    • 2000
  • It is necessary to install the arc generation facility in order to obtain the important technology for the design of breakers and switches, and for the improvement of their performance and reliability. With this facility, it is possible, to study the characteristics of Arc in air/gas/vacuum insulation environment. The facility briefly consists of capacitor bank which can charge enormous energy, an air-core reactor, experimental arc-chamber, and several measurement equipments. This facility can simulates the arc phenomena in breakers and switches by means of generating high currents. In order to study the arc phenomena in SF6 gas and vacuum and to test the quenching performance of the extinguishing chambers which are developing. we made experimental $SF_6$gas/vacuum chambers and measured several parameter's of chambers. And besides we visualized arc ignition and arc movement by means of high speed camera.

  • PDF

표준 단일모드 광섬유와 하이델타 광섬유사이의 저 손실 접속 기법 (Low Splicing Loss Technique between Standard Single Mode Fiber and High Δ Fiber)

  • 김광택;양병철
    • 한국광학회지
    • /
    • 제19권3호
    • /
    • pp.169-174
    • /
    • 2008
  • 열처리에 의한 광섬유 코어의 모드 확산과 모드 진화 현상을 이용하여 일반 통신용 단일모드 광섬유와 하이텔타(high ${\Delta}$) 광섬유 사이의 접속 손실을 줄일 수 있는 기법들을 제시하였다. 실험결과는 하이텔타 광섬유의 적절한 열처리를 통해 기계적 접속 손실이 2.3 dB에서 0.1 dB까지 감소함을 나타내었다. 반면 융착접속 후 접속 부위에 전기 방전이나 산소 불꽃으로 열을 인가하는 방법으로 $0.2{\sim}0.4dB$ 정도의 접속 손실을 달성하였다.

병렬아크의 고속차단에 관한 연구 (A Study on the High Speed Interruption of Parallel Arcing)

  • 길경석;지홍근;박대원;김일권;김영일;조영진
    • 조명전기설비학회논문지
    • /
    • 제22권12호
    • /
    • pp.95-100
    • /
    • 2008
  • 기존의 누전차단기는 병렬아크에 대해서 차단을 실패하거나 차단시간이 결어지는 결함이 있었다. 본 논문에서는 저압 옥내배선 계통에서 병렬아크를 모의하여 기존 누전차단기의 차단특성을 분석하고, 병렬아크 검출에 적합한 공심형 전류센서와 신호변환회로를 설계하여 기존 방식의 누전차단기에 적용하였다. 제안한 방식은 병렬아크의 발생위치와 관계없이 누전차단기를 동작시켰으며, 차단시간은 아크가 발생한 위상에 따라 $1.74{\sim}8.3[ms]$의 범위로 기존 차단기에 비해 약 5배 빠른 특성이다.

E-T(Electro-Thermal) 액츄에이터를 이용한 microgripper (Microgripper driven by E-T(Electro-Thermal) actuator)

  • 박호준;이현기;박정호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3325-3327
    • /
    • 1999
  • A microgripper driven by E-T (electro-thermal) actuators has been designed and fabricated by surface micromachining. This microgripper consists of two E-T actuators. Each actuator has two arms with different widths joined at the end to form a 'U' shape. The wider 'cold' arm has a narrow flexure at the end (anchor or electrode side) for easy bending, This actuator can be fabricated with only two masks - one for the sacrificial layer and the other for the poly-Si structure layer. An E-T actuator bends its arm due to unequal thermal expansion between the 'cold' arm and the 'hot' arm, This actuator tip moves laterally in an arcing motion towards the cold arm side when the structure is unevenly heated by the applied current. Therefore each microgripper is actuated inwards and can hold a micro object. The fabricated E-T actuator was operated in the range of $2{\sim}12V$ and $1{\sim}5mA$. and maximum tip displacement was $13.6{\mu}m$. This device may become useful in many applications because an E-T actuator can be designed and fabricated easily, and obtain large displacement.

  • PDF

여러환경조건에 의한 Silicon애자의 표면열화 진단기술 (Diagnosis Technique of Surface Aging according to Various Environment Condition for Silicon Polymer Insulator)

  • 박재준;정명연;이승욱;김정부;송영철;김희동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.76-81
    • /
    • 2004
  • This paper presents the results of spectral analysis of leakage current waveforms on contaminated insulators under various fog and environment conditions(salt fog, clean fog, rain) The larger the leakage current during 200ms, the higer the power spectrum at 60Hz. For almost equal maximum current during 200ms, however, the spectrum at 60hz and the odd order harmonics increase emphatically when discharges occur continuously for several half-waves. If contaminated insulators suffers from high salt-density fog, the leakage current occurs with high crest value intermittently, results in the low spectrum. Analysis of leakage current data showed that this electrical activity was characterized by transient arcing behavior contaminants are deposited on the insulator surface during salt fog tests. This provides a path for the leakage current to flow along the surface of the insulator. It is important to have an indication of the pollution accumulation in order to evulate the test performance of a particular insulator. If the drop in surface resistivity is severe enough, then the leakage current may escalate into s service interrupting flashover that degrade power quality.

  • PDF

Self-blast형 $SF_6$ 가스 차단기의 노즐용삭 분석 (Analysis on the Mass Loss in Self-blast type $SF_6$ Gas Circuit Breaker)

  • 정영우;배채윤;안희섭;최종웅;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1422-1423
    • /
    • 2006
  • In our study, the PTFE nozzle ablation in the high-voltage self-blast type $SF_6$ gas circuit breaker was investigated. The test circuit breaker has the structure that the pin electrode is moving and the pressure reservoir volume and the dimension is almost same as commercial 145kv 40kA circuit breaker for similar result in real circuit breaker. The variation of current and arcing time was the range of $36kA_{rms}$(symmetry) - $40kA_{rms}$(asymmetry) and 10-16 ms. From the measured data the tendecy of the mass loss of the nozzle to current load and arc energy was estimated. In this process, the distance from the arc to nozzle(PTFE) surface, area which was exposed to arc and stroke contour was considered. These results will be used to enhance the accuracy of the computational fluid dynamics analysis in circuit breaker and estimate the residual life time of a circuit breaker.

  • PDF

전력기기용 Nozzle의 전기적 특성 (Electrical Properties of Nozzle for Electrical Apparatus)

  • 박효열;강동필;안명상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.7-10
    • /
    • 2004
  • This paper presents the electrical properties of PTFE nozzle for a electrical apparatus. In the arcing environment in a electrical apparatus, radiation is considered to be the major energy transport mechanism from the arc to the wall. The fraction of the radiation power is emitted out of the arc and reaches the nozzle wall, causing ablation at the surface and in the depth of the wall. The energy concentration in the material leads to the depolymerization and eventually leads to the generation of decomposed gas as well as some isolated carbon particles. Adding some fillers into PTFE is expected to be efficient for improving the endurability against radiation. In this experiment, three kinds of fillers that have endurance in the high temperature environment were added into PTFE. Light reflectance of fillers was investigated. Dielectric constan and dissipation factor of PTFE composites were investigated. Dielectric constant and dissipation factor of the PTFE composites increased with increasing contents of the fillers.

  • PDF

ANSI 규격에 의한 주상 변압기의 동압력 내력시험에 관한 연구 (The Study of the Design Tests for Current Capability according to ANSI)

  • 김선구;김원만;나대열;노창일;이동준;정흥수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.909-911
    • /
    • 2003
  • The almost pole transformers are constructed with tank, cover, clamp etc., that contains the insulation oil, core, coil, terminals, bus and the other accessories. If some fault current will be flown by some trouble or accident, interior pressure of the transformer shall be very quickly rise, and mechanical components or insulation oil from the transformer enclosure shall be propelled or dropped from the tank. For the prevention of the above accident, recently the pole transformers should be done 'the Design Tests for Fault Current Capability' according to ANSI C57.12.20(1997) There are two tests method in this standard, Test Number I with a high current arcing fault, without internal fusible elements, shall be conducted on rack enclosure with its minimum designed air space. Test Number II with an internal fusible element, shall be conducted on each enclosure diameter utilizing the internal fusible elements. KEPCO recently request to be done the 'Design Tests for Fault Current Capability' for pole transformers according to KEPCO's standard ES141-$533{\sim}545$, PS141-$482{\sim}518$ and RS141-$611{\sim}628$ that is same with Test Number I of ANSI C57.12.20.

  • PDF