$CO_2$ 용접의 단락이행영역에 있어서 스패터 발생특성 (Characteristics of Spatter Generation in the Short Circuit Transfer Region of $CO_2$ Arc Welding)

  • 안영호;이종봉;최원규
    • Journal of Welding and Joining
    • /
    • 제19권6호
    • /
    • pp.630-635
    • /
    • 2001
  • The characteristics of spatter generation in the short circuit transfer region of $CO_2$ welding was investigated. Spatteriing phenomena could be classified into three types : Type I generated due to the abrupt increase of arc voltage in arcing duration. Type II by the gas ejection from molten metal and Type III generated by the arc instability at the moment of arc re-ignition just after short circuiting. Main observed types were dependent on the chemical composition of welding wires. The case of YCW12 wires was mainly composed of spatters generated by Type l and Type II, while most, spatters in YCW11 wires were generated by Type II and Type III.

  • PDF

아킹혼 금구류 섬락특성 연구 (A study on the flashover characteristics of arcing horn fittings)

  • 김태훈;곽주식;정문규;정재승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.453-454
    • /
    • 2015
  • 낙뢰에 대한 전력계통의 적절한 보호를 위해서 피뢰기/아킹혼의 적절한 보호작동 설계가 필요하다. 피뢰기/아킹혼은 낙뢰에 의해 이상전압 발생시 섬락 동작을 통하여 계통을 보호하므로, 절연파괴 특성에 대한 상세한 연구가 필요하다. 본 논문에서는 피뢰기/아킹혼의 섬락동작에 직접적인 영향을 주는 절연갭의 미세조정에 따른 절연파괴 특성에 대한 연구를 실험적으로 수행하였다. 실험 결과, 갭간격이 증가할수록 절연파괴전압은 증가하고, 그 증가폭은 지수적으로 감소하는 전형적은 방전 특성을 확인하였으며, 그 상세한 변화 값을 측정하였다. 또한 표준 갭간격에서의 섬락특성과 섬락전압 분포도를 구하여 절연협조 상태를 분석하였다.

  • PDF

PTFE 용삭을 고려한 초고압 복합소호 차단기의 성능 예측 (Prediction of Performance considering Ablated PTFE in High Voltage Self-blast Circuit Breaker)

  • 김진범;권기영;이학성
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.695-698
    • /
    • 2008
  • Self-blast circuit breakers utilize the energy dissipated by the arc itself to create the required conditions for arc quenching during the current zero. During the arcing period, high pressure, temperature and radiation of the arc could burn in pure SF6 gas and PTFE nozzle. Ablated nozzle shape and $SF_6$-PTFE mixture vapor affect the performance of an self-blast circuit breaker. After a number of tests, nozzle in circuit breaker is disassembled, a section of ablated nozzle is investigated precisely. Using computational fluid dynamics, the conservation equation for the gas and temperature, velocity and electric fields within breaker is solved. Before applying a section model, developed program is verified with experimental data. Performance of ablated nozzle shape is compared with original model through analysis program.

  • PDF

EPDM 고분자 애자에 대한 표면방전 및 누설전류파형의 고조파분석 (Harmonics Analysis of Leakage Current Waveforms and Surface Discharge for EPDM Polymer Insulator)

  • 박재준;양태규
    • 한국전기전자재료학회논문지
    • /
    • 제17권9호
    • /
    • pp.1013-1021
    • /
    • 2004
  • This paper presents the results of spectrum analysis of leakage current waveforms on contaminated polymer insulators under fog conditions. This is a basic study on development of a monitoring for aging degree and surface pollution state using distortion rate(%) of 3rd and 5th harmonics according fundamental frequency[60Hz] under environment conditions. Arcing on the surface was always associated with distortion in the leakage current ; hence the low frequency components of the leakage current can be used as a means to evaluate the surface degradation. The results indicate that the distortion rate by spectrum analysis is available for the monitoring of contamination condition of EPDM Polymer insulators.

0.7 inch FED Panel system build-up by using proper sealing process

  • Kwon, Sang-Jik;Hong, Kun-Jo;Cho, Tae-Hee;Lee, Jong-Duk;Oh, Chang-Woo;Kwon, Yong-Bum
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제3권1호
    • /
    • pp.85-89
    • /
    • 1999
  • FDE panel was successfully fabricated through the integration of a 0.7" diagonal Si-based Mo-tip FEA with 25${\times}$25 pixels, Y2O3:Eu or ZnO:Zn phosphor screen, and vacuum sealing through an exhausting glass tube, including a getter. The panel system was driven by an external driver circuit having pulse width modulation(PWM) driving scheme. Before character imaging, it was stabilized through tip aging by slowly increasing a pulse-mode emission current and phosphor aging by a coulombic charging process. After aging, luminescent characteristics such as emission uniformity, charging and arcing phenomena were shown to be improved significantly.

  • PDF

PHOENICS Code를 이용한 자력팽창 소호부 내 아크유동해석 (The Flow Analysis of Arc in LG Hybrid Interrupter Using PHOENICS Code)

  • 이종철;이방욱;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.44-46
    • /
    • 2001
  • This paper describes the use of the PHOENICS CFD package for the simulation of the high-current period of the arcing process in a hybrid rotating arc/auto expansion by interrupter. The operating principle of this device depends on rapid arc rotation due to the magnetic field created by the fault current through a coil which is mounted on contacts and also relies on the principle of thermal expansion created by arc energy in extinguishing chamber and finally causes pressure rise in expansion volume. This paper is divided into three main sections. The first gives a brief overview of the interrupter. The second section gives a full description of the methods used in the calculation. The final section presents some sample results for the hybrid interrupter.

  • PDF

고분자 절연재료의 트랙킹 열화에 미치는 오손액의 영향 (The Effect of Contaminants on Tracking Aging in Polymer Insulating Materials)

  • 조한구;박용관
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권8호
    • /
    • pp.770-777
    • /
    • 1997
  • Some polymer materials including epoxy resin are being instead of porcelain for outdoor insulating materials such as insulators bushings cable terminators and surge arrester housing. And the largest problem to be overcomed is the tracking and erosion of the outdoor polymer material brought about by dry band arcing during prolonged exposure to contaminations. In this paper the effect of surface tension wettability flow rate of contaminants with varying surfactant content and frequency of applied voltage on the tracking breakdown of epoxy insulating materials were investigated. As the flow rate of contaminant is increased the surface resistivity is decreased and the leakage current is increased the time to tracking breakdown is decreased. It is found that time to tracking breakdown depends on the surface tension of contaminant that is difference of wettability. And as the frequency of applied voltage is increased time to tracking breakdown decreased.

  • PDF

보조접지선 시공에 의한 송전선로의 내뢰성 향상효과 모의 (A Simulation of Lightning Faults Reducing Effects on the 154 kV Transmission Tower by Auxiliary Grounding)

  • 곽주식;심정운;심응보;최종기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1843-1846
    • /
    • 1997
  • This paper describes the fault reducing effects of the 154 kV transmission tower by auxiliary grounding from the top of the tower to ground. The grounding surge impedance of the auxiliary grounding system is calculated by CDEGS(:Current Distribution Electromagnetic Interference Grounding and Soil Structure Analysis), and the critical lightning back flashover current and arcing horn dynamic characteristics are simulated by EMTP/TACS(:Electromagnetic Transient Program/Transient Analysis of Control Systems). The calculated results of total LFOR(Lightning Flashover Rate) shows that the LFOR can be reduced from 5.2(count/100km. year) to 3.4 by auxiliary grounding on the 154 kV transmission tower with one ground wire shielding system.

  • PDF

단상재폐로 선로의 2차아크랜 대한 새로운 모델링 기법 (A New Modeling Technique for Secondary Arc on Single-Pole Switching Transmission Lines)

  • 박병철;이욱화;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.880-882
    • /
    • 1997
  • The secondary arcing phenomenon can be hardly modeled for computer simulation due to its particularly-nonlinear characteristics. This paper describes a new computer modeling technique for the secondary arc which can be implemented with the EMTP MODELS. The computer model proposed is based on realistic arc conduction behaviors through newly designed variable resistor modules which can be supported in the EMTP. In this Paper, for the variable resister modules, a new variable arc resistance formula is proposed. Simulation results using the proposed technique are compared with some previous studies.

  • PDF

에어컨에서 직렬아크검출 알고리즘에 관한 연구 (A Study on the Detection Algorithm of Series Arc Signals in Air Conditioners)

  • 지홍근;최성국;정광석;박대원;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1970-1976
    • /
    • 2009
  • This paper describes a series arc detection algorithm in a low-voltage wiring system. We designed and fabricated an arc detection circuit which consists of a high-pass filter with the low cut-off frequency of 170 kHz to attenuate power frequency. The series arcing phenomena was simulated by an arc generator specified in UL1699. In the experiment, various loads such as resistive loads, resistive loads controlled by a dimmer, and vacuum cleaners were used. Whether the signal is arc or noise is discriminated by pulse counts and periodicity of the detected signal.

  • PDF