A Study on the Toxicity Analysis of Combustion Gases of Architectural Surface Materials and Architectural Adhesives (건축용 외장재와 접착제 연소가스의 독성분석에 관한 연구)

  • Kim, Won-Jong;Park, Young-Ju;Lee, Hae-Pyeong;Lim, Suk-Hwan;Kim, Jung-In
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.4
    • /
    • pp.48-52
    • /
    • 2013
  • This study was carried out, using toxicity test apparatus, to analyze toxic gases of heat insulation material and adhesives of composite panels used for the architectural surface material when a fire occurs. The findings of this study show that CO, $CO_2$, HCOH, $CH_2CHCN$ and $NO_x$ were detected from styrofoam, reinforced styrofoam, polyurethane foam and glass fiber, but in the case of the polyurethane foam, HCl and HCN were detected as well. All the architectural adhesives released CO, $CO_2$ and $NO_x$, but HCHO was only detected from the adhesives for styrofoam, wood, tile, windows and doors; $CH_2CHCN$ was only from those for wood and stone; $C_6H_5OH$ was only from those for wood. The toxicity index was also measured for architectural surface material and adhesives. Polyurethane foam showed the highest index, 11.7, and glass fiber was followed as 6.8. Reinforced styrofoam showed 5.7 and styrofoam revealed the least 4.9. In the case of architectural adhesives, the highest ranking was those for stone 7.4, windows and doors 6.1, wood 5.3, tile 3.8, and styrofoam 3.7 were followed, respectively.

A Study on the Characteristics of Smoke Release for Architectural Surface Materials and Architectural Adhesives (건축용 외장재와 접착제의 발연특성에 관한 연구)

  • Park, Young Ju;Kim, Won Jong;Lee, Hae Pyeong;Yu, Jae Yeol;Yang, Young Suk
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.1
    • /
    • pp.21-24
    • /
    • 2014
  • In this study, we have investigated the maximum smoke density and the initial stage smoke density in order to see the characteristics of smoke release of the architectural surface materials and the architectural adhesives, using smoke density chamber. As a result of the study, polyurethane foam showed the highest smoke density index, 206.55 within 10 min. In the case of the other samples, reinforced styrofoam was followed as 39.90, general styrofoam 33.73, and glass fiber 5.40, respectively. In the intial stage of a fire, it is forecasted actually to give hardship at the clear visibility. In the case of architectural adhesives, the highest ranking was those for windows and doors 509.64, stone 275.63, wood 232.25, tile 18.65, and styrofoam 6.44 were followed, respectively. This result is an early research to show characteristics of smoke release through experiment. However, it is meaningful that this study can be used as a basic for further study on architectural fire hazard prediction.

Properties of Inorganic Adhesives according to Phosphate Type and Borax Ratio (인산염 종류와 붕사 첨가율에 따른 무기접착재의 특성)

  • Song, Ha-Young;Lim, Jeong-Jun;Khil, Bae-Su;Lee, Sang-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.4
    • /
    • pp.289-297
    • /
    • 2019
  • Epoxy resin adhesives are currently used as adhesives in buildings. Epoxy resin adhesives, which are organic materials, generate harmful substances when producing adhesives, and toxic substances are high in the residential space after installation. In addition, a large amount of carbon monoxide generated from organic materials in the case of a building fire leads to personal injury. This study evaluates the feasibility of inorganic adhesives using pure inorganic materials such as magnesia, phosphate, and borax as inorganic adhesives to replace existing organic adhesives. As a result of the experiment on the selection of adequate phosphate and the characteristics of the addition rate of borax used as a retarder, the potassium phosphate monobasic was obtained as a suitable phosphate and the characteristics according to the borax addition rate were compared with the quality standard of KS F 4923 The hardening shrinkage and heat change rate satisfied the quality standards. The tensile strength was satisfactory when the borax addition rate was 4% or more, but the adhesive strength did not meet the quality standards. Further studies are needed to improve adhesion strength.

Strength properties of inorganic adhesives using dead burned magnesia and phosphate according to addition ratio of borax (사소마그네시아와 인산염을 활용한 무기접착재의 붕사첨가율에 따른 강도특성)

  • Kim, Dae-Yeon;Pyeon, Su-Jeong;Lim, Jeong-Jun;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.48-49
    • /
    • 2018
  • Recently the old buildings have been increasing and increasing reconstruction. As a result, the frequency of use of architectural adhesives has increased. Adhesives are not only used for bonding but also for building materials used in various fields. However, since the adhesive is made of an organic material, it causes various skin diseases and sick house syndrome, and when a fire occurs, harmful substances are generated, and incomplete combustion may cause personal injury. Therefore, in this study, to solve the disadvantages of conventional adhesives, we tried to develop inorganic adhesives using inorganic materials.

  • PDF

Strength properties of magnesium oxide matrix according to type of phosphate (인산염 종류에 따른 산화마그네슘 경화체의 강도 특성)

  • Lim, Jeong-Jun;Pyeon, Su-Jeong;Kim, Dae-Yeon;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.79-80
    • /
    • 2018
  • Recently, the interest in remodeling of new and old buildings is increasing worldwide. As a result, the frequency of use of architectural adhesives has increased. Currently, adhesives used in buildings are made of organic materials in most cases, and epoxy resin adhesives are most widely used. However, epoxy resin adhesives contain formaldehyde and VOCs in the room during construction, which can cause sick house syndrome. In case of building fire, it may cause damage due to carbon monoxide generated from organic materials. It is urgent to study the problem of epoxy fill adhesive made of such organic materials. Therefore, the purpose of this study is to investigate the effect of the adhesion of epoxy resin adhesive, which is a problem of epoxy resin adhesive, which is an existing organic adhesive by using inorganic materials such as magnesia and phosphate, And the inorganic adhesive which does not emit the release amount as an inorganic material.

  • PDF

Compressive Shear and Bending Performance of Compressed Laminated Wood after Microwave Heating

  • Park, Cheul-Woo;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.5
    • /
    • pp.539-547
    • /
    • 2012
  • To manufacture laminated wood with improved mechanical properties by providing uniform adhesiveness, the adhesive was applied and the plate adhesive was laminated on the wood surface. Then, after laminating the wood on the top part of the adhesivebond, it was heated and dried while the adhesive was stiffened using microwaves, and the test piece was manufactured by compressing it with the press machine for thirty minutes. The temperature and the water content were examined according to the heating time of the wood heated with the microwave, and testing was conducted on the shear strength and flexural strength of the wood. In addition, the microstructure of the adhesive bond between the wood was recorded to confirm the penetrabilityinto the wood structure for the adhesive. After the test was conducted, it was found that the test piece manufactured with wood that has its water content leveled with the microwave heating showed improved shear strength and bending strength compared to the standard test piece. With regard to adhesives, liquefied polyvinyl acetate resin and plate's PVB resin were found to have superior adhesive strength. Also, after filming the cellular microstructure, it was found that when the laminated wood is heated with microwaves, the infiltration of the adhesive into the inside of the wood becomes easy, which makes it effective for improving adhesiveness.

A Study on Performance of Thermo-Humidity Indicator Card for Measuring Thermo-Humidity of Work Surface (자재 시공면의 온습도 측정을 위한 간이 온.습도 측정지의 성능 연구)

  • Heo, Jung-Yong;Choi, Chang-Ho;Lee, Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.4
    • /
    • pp.236-242
    • /
    • 2009
  • In finishing work, defects are often taken place by many factors. One of them is the thermo-humidity condition on the work surface as coating and anointing adhesives. Thus, the condition of thermo-humidity on work surface should be checked prior to the finishing work. However, many construction companies show a tendency to overlook it because not only are measurement tools so expensive but they don't have skilled hands about those tools. Therefore, we propose the measurement method that makes it easy to recognize surface thermo-humidity condition so as to reduce constructional flaws. And then we test this product. The test progresses to four stages with various conditions. We evaluate its usefulness and application possibility of this product in the field.

Architectural Implementation of the Indoor Air Quality in the Elementary School Classroom (학교건물의 실내공기환경 개선방안에 관한 건축계획적 연구)

  • Koo, Jae-Oh;Bae, Sun-Chul;Kim, Gon
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.15-22
    • /
    • 2007
  • Indoor air quality(IAQ) problems are not limited to large office buildings that are inadequately operated. In fact, many school buildings have significant potentials of air pollution and indoor air pollutants may be of particular concern because it is estimated that most young students who are physically weak to the pollutants spend about 90% of their time in classrooms. The goal of the study is to provide academic and architectural information on the major factors that influence indoor air quality in the elementary school. In order to gain a better understanding of IAQ problems in schools, a series of measurement studies of indoor air quality were designed and 3 different elementary school buildings located in Chuncheon were selected. The levels of CO, $CO_2$, and total volatile organic compounds(TVOCs) including formaldehyde(HCHO), major concern of this study, were measured in absence of students after class. As the results, it is noticeable that most indoor air pollution comes from sources inside the building, which are, for example, adhesives, upholstery, manufactured wood products, art and scientific supplies. The level of CO was measured similarly to that of outdoors, which means no impact on the indoor air problems since it is lower than the code. Ventilation played an important role in the level of $CO_2$ of which difference was 1.7 times in rough and 230 % of difference in the level was detected among the 3 school buildings. This concludes that indoor air problems might be result of poor building design with inadequate location of corridors within space organization or occupant activity patterns of ventilation.

Weatherability of Epoxy Cement Mortars without Hardener (경화제를 첨가하지 않은 에폭시 시멘트 모르타르의 내후성)

  • Jo, Young-Kug
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.801-809
    • /
    • 2006
  • Epoxy resin has widely been used as adhesives and corrosion-resistant paints in the construction industry for many years, since it has desirable properties such as high adhesion and chemical resistance. Until now, in the production of conventional epoxy cement mortars, the use of any hardener has been considered indispensable for the hardening of the epoxy resin. However we have noticed the fact that even without any hardener, the hardening process of the epoxy resin can proceed by the action of hydroxides in cement mortars. As a result the disadvantages of the two-component mixing of the epoxy resin and hardener have been overcome. The purpose of this study is to evaluate the mechanical properties and durability of epoxy cement mortar without a hardener exposed at indoor and outdoor for one year. The epoxy cement mortars without and with a hardener were prepared with various polymer-cement ratios, and tested for weight change, flexural and compressive strengths, water absorption, carbonation depth and pore size distribution. Especially, the basic properties of the epoxy cement mortars without hardener are discussed in comparison with ones with the hardener. From the test results, it is concluded thai the epoxy cement mortars without a hardener exposed at indoor and outdoor for one year have higher strength and better durability than ones with the hardener within the polymer-cement ratios of 10 to 20%.

A Study on the Fabrication of the Laminated Wood Composed of Poplar and Larch (포푸라와 일본잎갈나무의 집성재 제조에 관한 연구)

  • Jo, Jae-Myeong;Kang, Sun-Goo;Kim, Ki-Hyeon;Chung, Byeong-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.25-31
    • /
    • 1974
  • 1. Various gluing qualities applying Resorcinol Plyophen #6000 were studied on aiming the strength relationships of laminated woods resulted by single species [poplar (Populus deltoides), larch(Larix leptolepis)], mixed species of (poplar and larch), preservatives, treated poplar the scarf joint with mixed species of poplar and larch and the scarf joint treated with preservatives. 1. 1 On the block shear and on the DVL tension test, the mean wood failure ratio showed an excellent value i.e., above 65% and the tangential strength for larch was higher than that of radial, but it was reversed for poplar as shown in Tables 1 and 2. 1. 2 The lamina treated with Na-PCP reduced slightly the strength but the limited strength allowed for manufacturing laminated wood was not influenced by treating Na-PCP as shown in Tables 3 and 4. 1. 3 The safe scarf ratio in the plane scarf joint was above 1/12 for larch and 1/6 for poplar regard less of the chemical treatment or untreatment as shown in Tables. 5, 6, 7 and 8. 2. In the normal and boiled state, the gluing quality of the laminated wood composed of single[poplar (Populus deltoides), larch (Larix leptolepis)] and double species (poplar and larch) glued with Resorcinol Plyophen #6000 were measured as follow, and also represented the delamination of the same laminated wood. 2.1 The normal block shear strength of the straight and curved laminated wood (in life size) were more than three times of the standards adhesion strength. And, the value of the boiled stock was decreased to one half of the standard shear adhesion strength, but it was more than twice the standard strength for the boiled stock. Thus, it was recognized that the water resistance of the Resorcinol Plyophen #6000 was very high as shown in Tables 9 and 10. 2. 2 The delamination ratio of the straight and curved laminated woods in respect of their composition were decraesed, in turn, in the following order i. e., larch, mixed stock (larch+poplar) and poplar. The maximum value represented by the larch was 3.5% but it was below the limited value as shown in Table 11. 3. The various strengthes i.e., compressive, bending and adhesion obtainted by the straight laminaced wood which were constructed by five plies of single and double species of lamina i. e., larch (Larix leptolepis) and poplar (Populus euramericana), glued with urea resin were shown as follows: 3. 1 If desired a higher strength of architectural laminated wood composed of poplar (P) and larch (L), the combination of the laminas should be arranged as follows, L+P+L+P+L as shown in Table 12. 3.2 The strength of laminated wood composed of laminas which included pith and knots was conside rably decreased than that of clear lamina as shown Table 13. 3.3 The shear strength of the FPL block of the straight laminated wood constructed by the same species which were glued with urea adhesives was more than twice the limited adhesion strength, thus it makes possible to use it for interior constructional stock.

  • PDF