• 제목/요약/키워드: arc temperature

검색결과 657건 처리시간 0.034초

P122강 용접부의 대기중 고온산화 부식속도와 스케일 분석 (High-Temperature Oxidation Kinetics and Scales Formed on P122 Steel Welds in Air)

  • 박상환;이동복
    • 대한금속재료학회지
    • /
    • 제49권9호
    • /
    • pp.699-707
    • /
    • 2011
  • P122 steel, with a composition of Fe-10.57%Cr-1.79%W-0.96Cu-0.59Mn was arc-welded and oxidized between $600^{\circ}C$ and $800^{\circ}C$ in air for up to 6 months. The oxidation rates increased in the order of the base metal, weld metal, and heat-affected zone (HAZ), depending on the microstructure. The scale morphologies of the base metal, weld metal, and HAZ were similar because it was determined mainly by the alloy chemistry. The scale consisted primarily of a thin $Fe_2O_3$ layer at $600^{\circ}C$ and $700^{\circ}C$ and an outer $Fe_2O_3$ layer and an inner ($Fe_2O_3$, $FeCr_2O_4$)-mixed layer at $800^{\circ}C$. The microstructural changes resulting from heating between $600^{\circ}C$ and $800^{\circ}C$ coarsened the carbide precipitates, secondary Laves phases, and subgrain boundaries in the matrix, resulting in softening of the base metal, weld metal, and HAZ.

Leg Amputation due to Buerger's Disease: Management with Combined Korean Medicine

  • Won, Eun Sol;Lee, Hyun;Ryu, Hwa Yeon;Ku, Yong Ho;Jung, Ga Hyeon;Park, Chae Hyun;Kang, Jae Hui
    • Journal of Acupuncture Research
    • /
    • 제38권4호
    • /
    • pp.325-330
    • /
    • 2021
  • In this Case Report, a patient with Buerger's disease who had a leg amputation below his lower right knee and a vascular bypass of right leg, developed a wound caused by his prosthetic leg and subjective discomfort. The patient received skin flap surgery but the wound did not heal properly. He was admitted to the Korean Medicine Hospital where his wound, right leg coldness, and phantom pain were treated with combined Korean medicine. The patient was hospitalized again where he underwent micro-drilling surgery. The patient was re-admitted to the Korean Medicine Hospital where he received combined Korean medicine treatment (CKMT) and carbon arc light treatment (CALT) for his wound, leg coldness, stiffness, and hypoplasia. The temperature of his right leg increased, the numeric rating scale score for assessing pain fell from 5 to 1.5, and subjective discomfort was reduced (< 20%) suggesting this may be an effective treatment.

Preliminary conceptual design of a small high-flux multi-purpose LBE cooled fast reactor

  • Xiong, Yangbin;Duan, Chengjie;Zeng, Qin;Ding, Peng;Song, Juqing;Zhou, Junjie;Xu, Jinggang;Yang, Jingchen;Li, Zhifeng
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.3085-3094
    • /
    • 2022
  • The design concept of a Small High-flux Multipurpose LBE(Lead Bismuth Eutectic) cooled Fast Reactor (SHMLFR) was proposed in the paper. The primary cooling system of the reactor is forced circulation, and the fuel element form is arc-plate loaded high enrichment MOX fuel. The core is cylindrical with a flux trap set in the center of the core, which can be used as an irradiation channel. According to the requirements of the core physical design, a series of physical design criteria and constraints were given, and the steady and transient parameters of the reactor were calculated and analyzed. Regarding the thermal and hydraulic phenomena of the reactor, a simplified model was used to conduct a preliminary analysis of the fuel plates at special positions, and the temperature field distribution of the fuel plate with the highest power density under different coolant flow rates was simulated. The results show that the various parameters of SHMLFR meet the requirements and design criteria of the physical design of the core and the thermal design of the reactor. This implies that the conceptual design of SHMLFR is feasible.

가스분해 분석기법을 활용한 가스 전열 변압기의 상태 진단 연구 (A Study on the Condition Diagnosis for A Gas-insulated Transformer using Decomposition Gas Analysis)

  • 김아름;곽병섭;전태현;박현주
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.119-126
    • /
    • 2022
  • A growing number of gas-insulated transformers in underground power substations in urban areas are approaching 20 years of operation, the time when failures begin to occur. It is thus essential to prevent failure through accurate condition diagnosis of the given facility. Various solid insulation materials exist inside of the transformers, and the generated decomposition gas may differ for each gas-insulated equipment. In this study, a simulation system was designed to analyze the deterioration characteristics of SF6 decomposition gas and insulation materials under the conditions of partial discharge and thermal fault for diagnosis of gas-insulated transformers. Degradation characteristics of the insulation materials was determined using an automatic viscometer and FT-IR. The analysis results showed that the pattern of decomposition gas generation under partial discharge and thermal fault was different. In particular, acetaldehyde was detected under a thermal fault in all types of insulation, but not under partial discharge or an arc condition. In addition, in the case of insulation materials, deterioration of the insulation itself rapidly progressed as the experimental temperature increased. It was confirmed that it was possible to diagnose the internal discharge or thermal fault occurrence of the transformer through the ratio and type of decomposition gas generated in the gas-insulated transformer.

X-ray Absorption Near-edge Studies of Au1-xPtx alloys

  • Y.D. Chung;Lim, K.Y.;Lee, Y.S.;C.N.Whang;Park, B.S.;Y.Jeon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.164-164
    • /
    • 2000
  • Since Au-Pt alloys have various atomic structures depending upon composition and annealing temperature, it is very interesting to investigate the electronic structures of alloys. We studied the changes of the electronic structure I the Au-Pt alloys by x-ray absorption near edge spectroscopy (XANES). Two kinds of Au-Pt alloy samples were prepared by arc melting methods and ion-beam-mixing technique. The Pt L2, 3-edge and Au L2, 3-edge X-ray absorption spectra (XPS) were measured with the electron yield mode detector at the 3C1 beam line of the Pohang Light Source (PLS). It was found that there was a substantial decrease in the area of the Pt L2, 3 white lines compared with that of pure Pt. The observed decrease in white line area was attributed to an increase in the number of pure Pt. The observed decrease in white line area was attributed to an increase in the number of 5d-electrons at the Pt site upon alloy formation. However, the Au L2, 3 edge spectra for Au-Pt alloys are all similar to that of pure Au. This implies that the 5d hole count of Au is not changed by alloy formation with Pt.

  • PDF

HSC발전소 터빈용 초내열합금 Alloy 617 및 263 용접부의 미세조직에 미치는 후열처리의 영향 (Effects of Post Weld Heat Treatment on Microstructures of Alloy 617 and 263 Welds for Turbines of HSC Power Plants)

  • 김정길;심덕남;박해지
    • Journal of Welding and Joining
    • /
    • 제34권3호
    • /
    • pp.52-60
    • /
    • 2016
  • Recently nickel based superalloys are extensively being regarded as the materials for the steam turbine parts for hyper super critical (HSC) power plants working at the temperature over $700^{\circ}C$, since the materials have excellent strength and corrosion resistance in high temperature. In this paper, alloy 617 of solution strengthened material and alloy 263 of ${\gamma}^{\prime}$-precipitation strengthened material were prepared as the testing materials for HSC plants each other. Post weld heat treatment (PWHT) was conducted with the gas tungsten arc (GTA) welded specimens. The microstructure of the base metals and weld metals were investigated with Electron Probe Micro-Analysis (EPMA) and Scanning Transmission Electron Microscope (STEM). The experimental results revealed that Ti-Mo carbides were formed in both of the base metals and segregation of Co and Mo in both of the weld metals before PWHT and PWHT leaded to precipitation of various carbides such as Mo carbides in the specimens. Furthermore, fine ${\gamma}^{\prime}$ particles, that were not precipitated in the specimens before PWHT, were observed in base metal as well as in the weld metal of alloy 263 after PWHT.

저압용 누전차단기 접속부의 발열 및 금속 조직 분석에 관한 연구 (A Study on the Analysis of Heat and Metallurgical Structure of Connection Parts for Residual Current Protective Devices)

  • 최충석;송길목;김동욱;김동우;김영석
    • 한국화재소방학회논문지
    • /
    • 제18권4호
    • /
    • pp.57-63
    • /
    • 2004
  • 본 연구에서는 저압용 누전차단기 접속단자에서의 접촉압력에 따른 발열특성을 조사하고 차단기 단자와 전선에 접촉 불량이 발생했을 때의 전압, 전류파형과 산화물 증식 등을 분석하였다. 차단기 단자와 전선에 접촉압력이 가해지지 않았을 때는 접촉저항증가로 열이 발생하고 금속표면에 산화 막이 형성되었다. 이때 단자 외부 절연물의 온도는 접촉 불량에 의해 급격하게 상승하며 단자내부에서 미세한 불꽃과 연속적인 방전음이 발생하였다. 단자내부도체와 접속전선 접촉면에서 기계적 진동에 의한 접촉 불량이 발생했을 때, 접촉면에서 산화물이 증식되고 발열온도는 869℃이상으로 상승하여 전기재해의 위험이 높음을 알 수 있었다.

Type-I Ge clathrate 2상 합금의 열전특성 (Thermoelectric Properties of Two-Phases Alloys of Type-I Ge clathrates)

  • 오민욱;박수동;김봉서;위당문;송재성;이희웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.141-142
    • /
    • 2006
  • Thermoelectric properties and microstructures of $Sr_{8-x}Ba_xGA_{16}Ge_{30}$ alloys fabricated by the arc-melting method were investigated. The alloys with the nominal composition of $Sr_8Ga_{16}Ge_{30}$ and $Ba_8Ga_{16}Ge_{30}$ were the single-phase alloys, while those of $Sr_4Ba_4Ga_{16}Ge_{30}$ and $Sr_2Ba_6Ga_{16}Ge_{30}$ were two-phases alloys. Electrical resistivity and the Seebeck coefficient for both two-phases alloys were higher in magnitude than those of the single-phase alloys between room temperature and 873K The thermal conductivities for both two-phase alloys were reduced with respect to those of the single-phase alloys in the whole temperature range. The maximum values of ZT for $Sr_4Ba_4Ga_{16}Ge_{30}$ and $Sr_2Ba_6Ga_{16}Ge_{30}$ were achieved with the values of 0.69 at 753K and 0.51 at 754K, respectively, while those of $Sr_8Ga_{16}Ge_{30}$ and $Ba_8Ga_{16}Ge_{30}$ were 0.86 at 758K and 0.76 at 943K, respectively.

  • PDF

양축 정렬된 Ni 기판의 특성에 미치는 W 첨가의 효과 (The Influence of W Addition on Cube Textured Ni Substrates for YBCO Coated Conductor)

  • 김규태;임준형;김정호;장석헌;김호진;주진호;김찬중;송규정;신형섭
    • Progress in Superconductivity
    • /
    • 제6권1호
    • /
    • pp.64-68
    • /
    • 2004
  • We fabricated cube-textured Ni and Ni-W alloy substrates for coated conductors and characterized the effects of W addition on microstructure, mechanical strength, and magnetic properties of the substrate. Pure Ni and Ni-(2, 3, 5at.%)W alloys were prepared by plasma arc melting, heavily cold rolled and then annealed at various temperatures of $600-1300^{\circ}C$. The texture was evaluated by pole-figure and orientation distribution function (ODF) analysis. Mechanical properties were investigated by micro Vickers hardness and tension test. Ferromagnetism of the substrate was measured by physical property measurement system (PPMS). It was observed that Ni-W substrates had sharp cube texture, and the full-width at half-maximums (FWHMs) of in-plane texture was $^{\circ}$-5.57$4.42^{\circ}$, which is better than that of pure Ni substrate. In addition cube texture of Ni-W substrates was retained at higher temperature up to $1300^{\circ}C$. Microstructural observation showed that the Ni-W substrates had fine grain size and higher mechanical properties than the pure Ni substrate. These improvements are probably due to strengthening mechanisms such as solid solution hardening and/or grain size strengthening. PPMS analysis showed that addition of W effectively reduced saturation magnetization in applied magnetic field and Curie temperature.

  • PDF

생체용 타이타늄 합금의 산화거동 및 세포독성에 관한 연구 (A Study on Oxidation Behavior and Cytotoxicity Test of Ti-10Ta-10Nb Alloy)

  • 조홍규;이도재;이광민;이경구
    • 대한치과기공학회지
    • /
    • 제26권1호
    • /
    • pp.97-104
    • /
    • 2004
  • A new Ti-10Ta-10Nb alloy has designed and examined some possibility of forming more passive oxide film by oxidation treatment which is closely related to corrosion resistance and biocompatibility. Ti-6Al-4V and Ti-10Ta-10Nb alloys were prepared by consumable vacuum arc melting and homogenized at 1050$^{\circ}C$ for 24hours. Alloy specimens were oxidized at the temperature range of 400 to 750$^{\circ}C$ for 30minutes, and the oxide films on Ti alloys were analysed by optical microscope, SEM, XPS and TGA. Cytotoxicity test was performed in MTT assay treated L929 fibroblast cell culture by indirect method. It is found out that the oxide film on Ti-10Ta-10Nb alloy is denser and thinner compared to Ti-6Al-4V alloy. The weight gain during the oxidation was increased rapidly at the temperature above 650$^{\circ}C$ for Ti-6Al-4V alloy and above 700$^{\circ}C$ for Ti-10Ta-10Nb alloy respectively. It was analysed that the passive film of the Ti alloys consisted of TiO2 through X-ray photoelectron spectroscopy (XPS) analysis. It is found out by cytotoxicity test that moderate oxidation treatment lowers cell toxicity, and Ti-10Ta-10Nb alloy showed better result compared to Ti-6Al-4V alloy.

  • PDF