• Title/Summary/Keyword: appropriate level & range

Search Result 240, Processing Time 0.026 seconds

Traffic management for large-scale evacuation with public transportation and calculation of appropriate operating ratio

  • Ham, Seunghee;Lee, Jun;Lee, Sang Jo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3347-3352
    • /
    • 2022
  • In 2013, the International Atomic Energy Agency (IAEA) changed the recommended maximum range of the Emergency Planning Zone (EPZ) to 30 km, and the Kori Nuclear Power Plant in Republic of Korea has also expanded the EPZ to 30 km, following the recommendation. As a result, metropolitan cities with a high population density are contained within the EPZ, and evacuating millions of people should be considered if the 30 km range of evacuation is to take place. This study proposes an evacuation plan using buses (public transportation) to transport people outside of the EPZ, quickly and efficiently. To verify the appropriate mode share ratio of buses that can guarantee the right of vulnerable road users and reduce traffic congestion, a model was built simulating the Kori Nuclear Power Plant in Ulsan Metropolitan City. The scenarios were established by changing the mode share ratio of buses and passenger cars by 10%. Considering a large-scale network analysis at the city level, a cell transmission model was applied to calculate the evacuation time in each scenario. The result shows that the optimal mode share ratio of buses is 40%, with a total evacuation time of 132 min, considering feasible bus fleets in Ulsan Metropolitan City.

Combined Open Door Laminoplasty with Unilateral Screw Fixation for Unstable Multi-Level Cervical Stenosis : A Preliminary Report

  • Son, Seong;Lee, Sang Gu;Park, Chan Woo;Kim, Woo Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.2
    • /
    • pp.83-88
    • /
    • 2013
  • Objective : The authors reviewed their experiences of combined surgery (open door laminoplasty with unilateral screw fixation) for unstable multi-level cervical stenosis, to clarify the situation regarding the surgical approach most appropriate for the treatment of diffuse unstable multi-level cervical stenosis. Methods : From January 2011 to January 2012, combined surgery was performed for unstable multi-level cervical stenosis by one surgeon at our institution. The subjects of this study were 6 men of mean age 53.7 years (range, 48-71) with a mean follow-up of 9.3 (range, 3-14) months. All imaging studies showed severe multi-level cervical stenosis with spinal cord signal change, and instability or kyphotic deformity. A retrospective review of clinical, radiological, and surgical data was conducted. Results : Average laminoplasty level was 4.8 and the average screw fixation level was 5.0. Japanese Orthopedic Association score improved from an average of 5.2 to 11.2 points. According to Nurick's grades and Odom's criteria, symptom improvement was statistically significant. On the other hand, Cobb's angle changes were not significant. Average operation time was 5.86 hours with an average blood loss of 460 mL. No significant surgical complication was encountered. Conclusion : Despite the small cohort and the short follow-up duration, the present study demonstrates that laminoplasty with unilateral screw fixation is a safe and effective treatment for unstable multi-level cervical stenosis.

Logic gate implementation of constant amplitude coded CS/CDMA transmitter (정포락선 부호화된 CS-CDMA 송신기의 논리 게이트를 이용한 구현)

  • 김성필;류형직;김명진;오종갑
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.281-284
    • /
    • 2003
  • Multi-code CDMA is an appropriate scheme for transmitting high rate data. However, dynamic range of the signal is large, and power amplifier with good linearity is required. Code select CDMA (CS/CDMA) is a variation of multi-code CDMA scheme that ensures constant amplitude transmission. In CS/CDMA input data selects multiple orthogonal codes, and sum of these selected codes are MPSK modulated to convert multi-level symbol into different carrier phases. CS/CDMA system employs level clipping to limit the number of levels at the output symbol to avoid hish density of signal constellation. In our previous work we showed that by encoding input data of CS/CDMA amplitude of the output symbol can be made constant. With this coding scheme, level clipping is not necessary and the output signal can be BPSK modulated for transmission. In this paper we show that the constant amplitude coded(CA-) CS/CDMA transmitter can be implemented using only logic gates, and the hardware complexity is very low. In the proposed transmitter architecture there is no apparent redundant encoder block which plays a major role in the constant amplitude coded CS/CDMA.

  • PDF

Selection of Fusion Level for Adolescent Idiopathic Scoliosis Surgery : Selective Fusion versus Postoperative Decompensation

  • Kim, Do-Hyoung;Hyun, Seung-Jae;Kim, Ki-Jeong
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.473-485
    • /
    • 2021
  • Adolescent idiopathic scoliosis (AIS), which is associated with an extensive range of clinical and radiological presentations, is the one of the most challenging spinal disorders. The goals of surgery are to correct the deformity in 3 dimensions and to preserve motion segments while avoiding complications. Despite the ongoing evolution of classification systems and algorithms for the surgical treatment of AIS, there has been considerable debate regarding the selection of an appropriate fusion level in AIS. In addition, there is no consensus regarding the exact description, relationship, and risk factors of coronal decompensation following selective fusion. In this review, we summarize the current concepts of selection of the fusion level for AIS and review the available information about postoperative coronal decompensation.

Band Structure Engineering of Monolayer MoS2 by Surface Ligand Functionalization

  • Lee, Sang Yoon;Ramzan, Sufyan
    • Proceeding of EDISON Challenge
    • /
    • 2015.03a
    • /
    • pp.367-370
    • /
    • 2015
  • Monolayer transition metal dicalcogenide (TMDC) materials are currently attracting extensive attention due to their distinctive electronic, transport, and optical properties. For example, monolayer $MoS_2$ exhibits a direct band gap in the visible frequency range, which makes it an attractive candidate for the photocatalytic water splitting. For the photoelectrochemical water splitting, the appropriate band edge positions that overlap with the water redox potential are necessary. Similarly, appropriate band level alignments will be crucial for the light emitting diode and photovoltaic applications utlizing heterojunctions between two TMDC materials. Carrying out first-principles calculations, we here investigate how the band edges of $MoS_2$ can be adjusted by surface ligand functionalization. This study will provide useful information for the realization of ligand-based band engineering of monolayer $MoS_2$ for various electronic, energy, and bio device applications.

  • PDF

Effects of Integrated Soil Amelioration Techniques to Mature Newly Established Research Fields

  • Jung, Sug-Jae;Hyun, Byung-Keun;Sonn, Yeon-Kyu;Cho, Hyun-Jun;Choi, Jung-Won;Lee, Pyeong-Ho;Lim, Dong-Hyuk
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.49 no.2
    • /
    • pp.208-217
    • /
    • 2016
  • The Rural Development Administration moved to Jeonju for the balanced development of the land. This situation required establishment of new research fields with soils appropriate to cultivation. We applied a variety of amelioration techniques to mature soils of new research fields of the National Institute of Agricultural Science (NAS) and evaluated effects of the integrated amelioration techniques. The schedule of amelioration was following: 1) location of research fields was determined, 2) surface and subsoil samples were collected separately, 3) after aligning the top level of research fields, subsoil and surface soil were re-established with soil amendment, 4) the green manure crops were grown four seasons to improve the uniformity and increase the organic content of the research field, and 5) drainage canal and/or underdrainage were applied to poorly drained fields. The last green manure crop was rape in RDA fields and green barley in NAS fields. The average height, fresh weight, and dry matter weight of rape in good condition were 123 cm, $3,938kg\;10a^{-1}$, and $651kg\;10a^{-1}$, respectively. The height, fresh weight, and dry matter of green barley, on average, were 97 cm, $3,013kg\;10a^{-1}$, and $1,004kg\;10a^{-1}$, respectively. In the chemical properties of paddy field, pH and levels of silicate, calcium, magnesium, and potassium were in appropriate range but organic matter content of $16g\;kg^{-1}$ was less than the optimum level. In the chemical properties of upland field, pH and levels of phosphorus, calcium, magnesium, and potassium were appropriate range but organic matter content of $12g\;kg^{-1}$ was less than the optimum range. Evaluation of well-adapted soil was performed. The field in RDA was classified into the superior class with points ranging from 90 to 95 by the field evaluation test. The fields in NAS were mainly evaluated as the superior class with points greater than 85. However, some fields in NAS remained low quality with scores between 80 and 83. Further soil amelioration practices were suggested to fields with low soil quality.

Finite element analysis of callus generation in fractured bones according to the strain distribution (골절부 변형률에 따른 골절부 가골 형성 과정의 유한요소해석)

  • Kim, Suk-Hun;Park, Myong-Gil;An, Song-Tao;Cho, Sung-Kyum;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.22 no.3
    • /
    • pp.29-34
    • /
    • 2009
  • In this paper, finite element analyses were used to estimate the strain distribution at the fracture site of a tibia bone. A stainless steel bone plate and various composite bone plates were considered to find out the best conditions for callus generation while bone fracture was cured for 16 weeks. Through this research, the appropriate load condition which makes the strains between the appropriate range($2{\sim}10%$) was sought. From this analysis, it was found that lower level of external load is needed for the appropriate strain for the case of composite bone plate application and it was also found that the composite bone plate had potential advantages for effective bone fracture healing relieved stress shielding effect.

A Study on the size of the school rationalization orientation considering the local characteristics (지역특성을 고려한 학교규모 적정화 방향 설정에 관한 연구)

  • Lee, Sang-Min;Cho, Chang-Hee
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.15 no.1
    • /
    • pp.40-48
    • /
    • 2016
  • School appropriate scale refers to the size of the school to minimize students' educational deficits and ensure an appropriate level of students, the number of classes, class size, etc., and maximize educational effects. Difficult set of absolute standards appropriate scale school, contemporary social situations and educational effects, and seek a comprehensive and reasonable direction, considering this is required. School appropriate scale it is preferable to consider the effect of conditions in areas such as education, curriculum, but it is common to set the range in terms of school operational effectiveness, and efficiency of education funding, school environment. So the concept of the appropriate scale including the school's status changes associated with school size, is seeking a new direction is needed so that the school environment, etc. are considered.

Reexamination of Patient's Cost-sharing System for Oriental Medical Services in the Korean National Health Insurance (한방의료의 건강보험 적정 본인부담률 추계)

  • Kim, Jin-Hyun;Yoo, Wang-Keun;Seo, Dong-Min
    • Health Policy and Management
    • /
    • v.17 no.1
    • /
    • pp.1-27
    • /
    • 2007
  • This study is designed to estimate an appropriate level of patient's cost-sharing for oriental medical services in the Korean National Health Insurance. The findings of this study can be summarized as follows: 1) The current co-payment system for oriental medical services does not reflect its cost structure in clinical practice due to inconsistency of cost-sharing plan in the NHI. 2) Both oriental medical institutions and their patients, as a result, are at a relative disadvantage in financial burden, compared with other services. 3) The substantial proportion of patients' cost-sharing depends on the amount of co-payment and the range of medical cost that a flat rate is applied to. 4) The extension of the range doesn't make any substantial decrease in patient's cost-sharing. 5) The fixed amount of co-payment is more sensitive than a range to total variations of patient's cost-sharing. Based on the above, the budget impacts of a new co-payment system were estimated for each co-insurance rate, according to given scenarios. The results range from -59 billion Won (-8.5%) to 16 billion Won(2.3%).

Variable Structure PWM Controller for Highly Efficient PV Inverters

  • Oh, Seong-Jin;SunWoo, Myoung-Ho
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.866-873
    • /
    • 2009
  • In general, the output voltage level of a PV array varies widely at various irradiances and temperatures. The MPP (Maximum Power Point) range of a medium- or high-power PV PCS is normally 450~830Vdc or 300~600Vdc. This means the PV PCS should operate in a wide range of modulation indexes. The PV PCS should satisfy the harmonic current requirement that the TDD (Total demand distortion) shall not exceed 5%. This paper proposes a new PWM control method for a medium- or high-power PV PCS which increases the efficiency of power conversion in all operation ranges with acceptable harmonic ripple currents. This paper compares and analyzes appropriate PWM schemes for the PV PCS in the view points of conversion efficiency and current harmonics.