• 제목/요약/키워드: apparent power

검색결과 273건 처리시간 0.036초

Power line interference noise elimination method based on independent component analysis in wavelet domain for magnetotelluric signal

  • Cao, Xiaoling;Yan, Liangjun
    • Geosystem Engineering
    • /
    • 제21권5호
    • /
    • pp.251-261
    • /
    • 2018
  • With the urbanization in recent years, the power line interference noise in electromagnetic signal is increasing day by day, and has gradually become an unavoidable component of noises in magnetotelluric signal detection. Therefore, a kind of power line interference noise elimination method based on independent component analysis in wavelet domain for magnetotelluric signal is put forward in this paper. The method first uses wavelet decomposition to change single-channel signal into multi-channel signal, and then takes advantage of blind source separation principle of independent component analysis to eliminate power line interference noise. There is no need to choose the layer number of wavelet decomposition and the wavelet base of wavelet decomposition according to the observed signal. On the treatment effect, it is better than the previous power line interference removal method based on independent component analysis. Through the de-noising processing to actual magnetotelluric measuring data, it is shown that this method makes both the apparent resistivity curve near 50 Hz and the phase curve near 50 Hz become smoother and steadier than before processing, i.e., it effectively eliminates the power line interference noise.

Expected Future Market Volume of HTS Equipment in South Korea

  • Yoon, Jae-Young;Lee, Seung-Ryul;Yang, B.;Lee, Seung-Yeup;Won, Young-Jin
    • Journal of Magnetics
    • /
    • 제16권2호
    • /
    • pp.129-133
    • /
    • 2011
  • This paper shows the entire future market volume of the HTS power industry, one of main smart grid equipment, in the case of the final market penetration ratio reaching 100% in the domestic market (South Korea). In this paper, the market penetration ratio is determined using the judgment method, with the market penetration S-curve induced using the Delphi method and the Product Life Cycle from 2011 (supposed launching year, not realistic physical year), to 2050 (expected final target year). This paper analyzes the HTS market penetration ratio of each stage, apparent innovation, early adapters, and the early/late majority and laggard stage, using the S-curve, thus calculating the total future market volume of HTS equipment in the positive sense. Finally, this paper estimates the quantitative analysis results for the HTS4-items (cable, FCL, transformer, rotation machine) of each year within the domestic market.

신교통 차량 추진용 리니어모터의 운전성능측정 및 모니터링시스템 구축 (The Monitoring system for the measurement of the operating performance of a LIM which can be drive a new vehicle)

  • 장석명;박영태;서진호;정상섭;이성호;함상용;박찬일;정락교;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.74-76
    • /
    • 1997
  • This paper describes the implementation for electrical quanties and mechanical quanties monitoring system of the LIM driven by a inverter. The monitoring system can be display the characteristics of it's quanties, such as voltage, current, power, power factor, frequency, apparent power, thrust, speed, position, normal force, on the real time.

  • PDF

Cooling Geometry Dependent Operation Properties in a Diode End-Pumped Monolithic Yb:YAG Laser

  • Moon, Hee-Jong;Lim, Changhwan
    • Journal of the Optical Society of Korea
    • /
    • 제20권5호
    • /
    • pp.593-600
    • /
    • 2016
  • Operation properties, such as output power, beam radius, and crystal temperature rise were investigated in a diode-pumped edge-cooled monolithic Yb:YAG laser with ~ 4 W pumping level. The output power showed saturation behavior because of severe temperature rise and poor spatial overlapping between pump beam and lasing mode. Face cooling geometry by using a sapphire plate was also investigated. No apparent saturation behavior in output power was observed due to the reduced temperature rise, which could be attributed to efficient heat removal through the crystal-sapphire interface.

Evaluating Predictive Ability of Classification Models with Ordered Multiple Categories

  • Oong-Hyun Sung
    • Communications for Statistical Applications and Methods
    • /
    • 제6권2호
    • /
    • pp.383-395
    • /
    • 1999
  • This study is concerned with the evaluation of predictive ability of classification models with ordered multiple categories. If categories can be ordered or ranked the spread of misclassification should be considered to evaluate the performance of the classification models using loss rate since the apparent error rate can not measure the spread of misclassification. Since loss rate is known to underestimate the true loss rate the bootstrap method were used to estimate the true loss rate. thus this study suggests the method to evaluate the predictive power of the classification models using loss rate and the bootstrap estimate of the true loss rate.

  • PDF

UPFC가 설치된 선로에서 거리계전기의 동작특성에 관한 연구 (A Study for Operation Zone of Distance Relay on Transmission Line Connected UPFC)

  • 정창호;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.130-132
    • /
    • 2001
  • This paper discusses the operation zone of distance relay on transmission line connected unified power flow controller(UPFC). Depending on operating conditions of UPFC, the trip characteristics of distance relay is influenced by the prefault conditions. In this paper, apparent impedance of distance relay influenced by the UPFC control of distance is calculated.

  • PDF

전세계(全世界) 발송전계통(發送電系統)의 에너지관리(管理)시스템조사(調査) (SURVEY OF ENERGY MANAGEMENT SYSTEMS FOR GENERATION AND TRASMISSION SYSTEMS THROUGHOUT THE WORLD)

  • 윤갑구;유홍우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1983년도 하계학술회의강연.논문초록집
    • /
    • pp.177-179
    • /
    • 1983
  • This paper provides a primer for the Energy Control Center designers and a comprehensive overview for utility management personnel that desire an understanding of the Energy Management System for a Generation-Transmission System. Any errors or apparent misrepresentation of facts that may appear in the list are entirely unintentional. I would greatly appreciate being informed of any such omissions and errors.

  • PDF

여러 가지 교반조에서 Paddle 임펠러의 교반소요동력 특성 (Characteristic of Power Consumption for Paddle Impeller in Various Agitated Vessels)

  • 이영세
    • 공업화학
    • /
    • 제16권5호
    • /
    • pp.698-704
    • /
    • 2005
  • 구형교반조 및 원통교반조에서 paddle 임펠러의 교반소요동력을 넓은 범위의 레이놀즈수 영역에서 측정하였다. 구형교반조는 교반조 높이가 직경과 같고, 구형교반조의 체적과 같은 원통교반조의 겉보기 직경을 이용하여 구형교반조 및 원통교반조 모두에 적용할 수 있는 교반소요동력 상관식을 구했다. 이 상관식은 Nagata 등 및 Hixson 등의 실험결과에도 양호하게 상관되었다. 또한 임계레이놀즈수는 본 상관식에서 얻은 층류영역에서 난류영역으로의 전이에 관한 계수 $C_{tr}$에 잘 상관되었다.

부분방전검출 신뢰도 향상을 위한 UHF 센서개선 및 성능검증 (Performance Verification and Improvement of UHF Sensor for the Increasement of the Partial Discharge Detection Reliability)

  • 김원규;김민수;백영식
    • 전기학회논문지
    • /
    • 제63권10호
    • /
    • pp.1461-1466
    • /
    • 2014
  • GIS(Gas Insulated Switchgear) is important power apparatus which have strong dielectric strength, supply electric power and is a part of the power system. Most substation type is configured as GIS. Recently, because of continuous increasement of GIS demand resulted from high quality & big capacity of electric power, the necessity of the preventive & diagnosis system is being expanded gradually. GIS partial discharge occurred on the UHF band is detected effectively by the method to IEC 60270 that recommend to be able to detect the apparent minimum discharge, 5 pC. Additionally, the UHF sensor should be installed to detect PD signal if Partial discharge signal, 5 pC occur in every part of GIS. Currently PD diagnosis system applying UHF sensor for GIS with various voltage level like 154 kV, 345 kV, 765 kV have been operated. And it is necessary to measure and analyze insulation breakdown phenomenon of inside GIS exactly. In this paper, we proposed Fat-dipole patch UHF sensor that is developed and more sensitive, excellent wide-range characteristic than the exising UHF sensor. And we performed KERI (Korea Electrotechnology Research Institute) reference test, which showed the excellent result for the all tests.

유도전동기에 대한 역률 보상설비의 특성 해석 (A Characteristic Study on the Power Factor Correction Application for Induction Motor)

  • 김종겸;박영진
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.25-31
    • /
    • 2008
  • 유도전동기의 자계는 전류의 방향에 따라 자화 및 감자되는 특성을 가지고 있다. 전통기의 자계를 형성하는데 필요한 자화전류는 유도성으로 무효전력의 대부분을 차지하고 있다. 무효전력은 유도전동기가 동작하는데 필요한 자계를 지속시키는 역할을 한다. 유도전통기의 역률은 낮은 편이므로 역률 보상이 필요하다. 유도전동기를 정격출력보다 낮은 부하로 운전할 경우 유효전력에 비해 무효성분의 비율증가로 역률이 낮아진다. 역률 보상장치의 용량은 전동기 정격에 맞도록 설치하기를 권고하고 있다. 그러나 부하의 운전상황에 따라 역률 보상용 커패시터 값은 수정하기가 어렵다. 본 논문에서는 저압 소용량 유도 전동기에 연결된 부하의 변화에 따라 전력 및 역률의 동작특성을 해석한 결과 기존에 제시된 낮은 역률 보상용 파라미터는 수정되어야 함을 확인하였다.