• Title/Summary/Keyword: apparatus development

Search Result 701, Processing Time 0.024 seconds

A Study on Development of Over-load Fault Prevention Apparatus using Distribution Line Voltage (배전선로 선로전압을 이용한 과부하 사고 예방장치 개발에 관한 연구)

  • Kwak, D.K.;Park, D.H.;Park, Y.J.;Jung, D.Y.;Kim, D.K.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.617-618
    • /
    • 2012
  • Recently as the inactive response characteristics of the existing RCD(Residual Current protective Device) used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper is proposed a prevention apparatus using neutral line voltage and semiconductor switching devices for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The proposed prevention apparatus confirms the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker(RCD) through various operation performance analysis.

  • PDF

Performance Evaluation of Evacuation in Subway Station Stairs using Movement Recording Apparatus (이동정보 기록장치를 이용한 전철 계단 피난평가 연구)

  • Kim, Young Gil;Kim, Eung Sik
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.123-127
    • /
    • 2018
  • Recent catastrophic accidents at the underground subway stations in South Korea have proven that the subway evacuation is an important safety concern. Previous studies have used commercial programs for safety assessment or have been focused on development of computing algorithms rather than the basic analysis data which form the foundation of studies. In this study, we designed a new movement recording apparatus which measured and analyzed crowd movements including but not limited to moving velocity, specific flow rate and crowd density. Moreover, We propose new effective analysis method for evacuation studies with this apparatus.

Development of Microwave Extraction Method for the Active Ingredients and Functional Constituents of Paeonia Root (마이크로웨이브 추출방법을 이용한 작약의 유효성분 추출 및 생리활성 측정)

  • Lee, Hyojin;Jang, Kyoung won
    • Korean Journal of Pharmacognosy
    • /
    • v.52 no.3
    • /
    • pp.157-162
    • /
    • 2021
  • The heat-mediated reflux apparatus extraction of Paeonia lactiflora Pall. has been widely used as a traditional extraction method. In this paper, the microwave apparatus extraction method of Paeonia Radix was performed and the active ingredients and functional constituents were compared with the reference extraction method. The most effective extraction condition of albiflorin using the microwave was 120℃ in 50% methanol, and paeoniflorin was maximally extracted at 60℃. The reduced level of paeoniflorin molecule at high-pressure and high-temperature extraction condition was caused by the molecular instability. Additionally, the microwave extraction of 50% methanol extracts at 150℃ showed the highest functional constituents determined by in vitro DPPH radical scavenging activity, polyphenol concentration, and tyrosinase inhibition assay. The microwave apparatus was adapted as a rapid, low-cost, and environmentally friendly method to extract active ingredients and the practical extraction conditions of Paeonia Radix can be used in industrial applications.

Development of apparatus for Single-sided Wet Etching and its applications in Corrugated Membrane Fabrication

  • Kim, Junsoo;Moon, Wonkyu
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.10-14
    • /
    • 2021
  • Wet etching is more economical than dry etching and provides a uniform etching depth regardless of wafer sizes. Typically, potassium hydroxide (KOH) and tetra-methyl-ammonium hydroxide (TMAH) solutions are widely used for the wet etching of silicon. However, there is a limit to the wet etching process when a material deposited on an unetched surface reacts with an etching solution. To solve this problem, in this study, an apparatus was designed and manufactured to physically block the inflow of etchants on the surface using a rubber O-ring. The proposed apparatus includes a heater and a temperature controller to maintain a constant temperature during etching, and the hydrostatic pressure of the etchant is considered for the thin film structure. A corrugation membrane with a diameter of 800 ㎛, thickness of 600 nm, and corrugation depth of 3 ㎛ with two corrugations was successfully fabricated using the prepared device.

A study on the development of a performance evaluation test apparatus for reinterpreting the vibration demand response spectrum for waterproof layers (방수층에 전달되는 진동 요구응답스펙트럼을 재해석 한 성능평가 시험장치 개발에 관한 연구)

  • Kim, Soo-Yeon;Lee, Seung-Jin;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.208-209
    • /
    • 2021
  • In 2017, 100 aftershocks with a magnitude of 2.0~3.0 and 615 minor earthquakes in Pohang in Korea caused the collapse and destruction of aggregate, tile, glass, and other structural components of multi-family houses constructed as finishing materials for buildings, causing damage to vehicles and casualties. Based on this factor, seismic design standards were established for non-structural elements of buildings that were applied only to past structures. Therefore, this study reinterpreted various vibration response spectra transmitted to waterproof layers as well as the definition and concept of the waterproof layer demand response spectrum derived by developing various vibration response test evaluation devices through a new testing apparatus.

  • PDF

The Development and Evaluation of Sidestream Smoke Collecting Apparatus Compatible for Linear Smoking Machine (다채널 선형자동흡연장치 부착형 부류연 포집장치의 개발과 평가)

  • Kim Hyo-Keum;Hwang Keon- Jung;Ji Sang-Un;Lee John-Tae;Rhee Moon-Soo
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.27 no.1 s.53
    • /
    • pp.120-126
    • /
    • 2005
  • The Fishtail Chimney system mounted on 1 channel smoking machine is not appropriate for the routine analysis of sidestream smoke, because of its low repeatability and very long time required for smoke collection. To overcome this inconvenience, we developed a new sidestream smoke collecting apparatus compatible for 8 channel linear smoking machine. An electric motor driven stroke and automatic control system were adopted in this device to maximize convenience and efficiency of its operation. Also, we carried out the international collaborative study on monitoring sidestream smoke analysis to test the performance of this system. From the statistical analysis of the data obtained in our laboratory and other participating labs, it has been indicated that the newly developed sidestream smoke collection apparatus could be applicable to the routine analysis of sidestream smoke.

Development of an Apparatus for Removing Magnetic Sludge by Permanent Magnets Set up in the Condenser of the Power Plant (영구자석을 이용한 복수기 집수정 내부 자성이물질 제거장치 개발)

  • Bae, Jun-Ho;Kim, Moon-Saeng;Hwang, Beom-Cheol;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.9
    • /
    • pp.938-948
    • /
    • 2009
  • In this paper, permanent magnets were used to remove magnetic sludge in the condenser of the power plant. To obtain the flow characteristics and magnetic information that are needed for determining a proper design of the magnetics sludge removal apparatus, numerical simulations were performed through the use of two commercial codes, ANSYS Workbench-Emag and CFX. Experiments were also performed on various kinds and sizes of magnets to obtain the magnetic information through a gauss meter. By analyzing the results of simulations and experiments, the minimum magnetic force that is able to remove the any size of the magnetic sludge in the condenser was calculated, and the design of the removal apparatus was confirmed. The test model which was confirmed by simulations and experiments was made. After testing, the test results were compared with those of numerical simulations and have good agreements.

Development of Corrosion Rust Removing Unit for Small Ship Propeller (소형선박용 프로펠러의 부식 녹 제거장치 개발)

  • Kim, Gui-Shik;Han, Se-Woong;Hyun, Chang-Hae
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.6 s.67
    • /
    • pp.72-77
    • /
    • 2005
  • The materials used in a ship screw propeller are commonly made with brass. The seawater corrosion and seawater cavitation of the screw propeller reduces the propulsive performance of the ship. In screw manufacturing, the corrosion rust of the screw propeller is removed through a hand grinding method. The grinding process produces dust of the heavy metals from the brass. The dust creates a poor working environment that is harmful to the health of the workers. An automatic corrosionrust removing apparatus, using a blasting method, was developed for the improvement of screw polishing conditions and its working environment. The performance of this apparatus was investigated by surface roughness, weight loss rate, hardness, electrochemical corrosion resistance, and cavitation erosion, after removing of the corrosion rust under various blasting conditions. Two medias of alumina and emery were used in this experiment. The surface roughness and hardness of the screw were improved by this apparatus. The electrochemical corrosion potential (Ecorr) and current density (Icorr) were measured by the dynamic polarization method, using a potentiostat,under the conditions of surface polishing with grinding, blasting, wire brushing, and fine sand papering. The test results prove that the new corrosion rust-removing apparatus improves the surface performance of a screw propeller.

Development of Experimental Apparatus for Carbon Dioxide Geological Storage (이산화탄소 지중저장을 위한 실내 모사실험 장치 개발)

  • Park, Sam-Gyu;Cho, Seung-Jun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.141-144
    • /
    • 2008
  • Geological storage of carbon dioxide has been studying in advanced countries to reduce greenhouse gases and a pilot site for geological storage is also in operation in the deep saline aquifer. Seismic wave and electrical resistivity tomography methods are applicable to monitoring techniques and they are used to evaluate the distribution range and behavior of the carbon dioxide injected in the porous sandstone formations. This paper describes the construction of an experimental apparatus which consists of a high pressure vessel and a measurement system for geological storage of carbon dioxide. The experiment apparatus will be used to measure seismic velocities and resistivities during the injection of carbon dioxide at the supercritical phase in the porous sandstones.

  • PDF

Development and demonstration of an erosion-corrosion damage simulation apparatus (배관 침부식 손상 연속모사 장비 개발 및 실증)

  • Nam, Won Chang;Ryu, Kyung Ha;Kim, Jae Hyoung
    • Corrosion Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.179-184
    • /
    • 2013
  • Pipe wall thinning caused by erosion and corrosion can adversely affect the operation of aged nuclear power plants. Some injured workers owing to pipe rupture has been reported and power reduction caused by unexpected pipe damage has been occurred consistently. Therefore, it is important to develop erosion-corrosion damage prediction model and investigate its mechanisms. Especially, liquid droplet impingement erosion(LDIE) is regarded as the main issue of pipe wall thinning management. To investigate LDIE mechanism with corrosion environment, we developed erosion-corrosion damage simulation apparatus and its capability has been verified through the preliminary damage experiment of 6061-Al alloy. The apparatus design has been based on ASTM standard test method, G73-10, that use high-speed rotator and enable to simulate water hammering and droplet impingement. The preliminary test results showed mass loss of 3.2% in conditions of peripheral speed of 110m/s, droplet size of 1mm-diameter, and accumulated time of 3 hours. In this study, the apparatus design revealed feasibility of LDIE damage simulation and provided possibility of accelerated erosion-corrosion damage test by controlling water chemistry.