• 제목/요약/키워드: apparatus

검색결과 4,308건 처리시간 0.032초

관내법 시험시 Air-Damping 이 흡음계수에 미치는 영향 고찰 (Investigation on the Effects of Air-Damping on the Sound Absorption Coefficients Measured in the Tube)

  • 정완섭;서재갑;이두희;황재호
    • 소음진동
    • /
    • 제7권5호
    • /
    • pp.797-801
    • /
    • 1997
  • This paper raises issues in testing the absorption coefficients of sound-absorptive samples using the standing wave apparatus according to the Korean standard of KS F 2814. The standard code does not consider any effect of air-damping which is significant in testing relatively low sound-absorptive samples. This limitation has been shown to yield much variation of sound absorption coefficients for recent samples tests whose coefficients are less than 10%. An improved method of calculating the sound absorption coefficients is proposed in this work and its effectiveness in real test is also illustrated. Finally, the guideline for the modification of our national standard code KS F 2814 is proposed.

  • PDF

Cryogenic Fracture Toughness Evaluation for Austenitic Stainless Steels by Means of Unloading Compliance Method

  • Yu, Hyo-Sun;Kwon, Il-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제15권1호
    • /
    • pp.26-34
    • /
    • 2001
  • Most research to date concerning the cryogenic toughness of austenitic stainless steels has concentrated on the base metal and weld metal in weldments. The most severe problem faced on the conventional austenitic stainless steel is the thermal aging degradation such as sensitization and carbide induced embrittlement. In this paper, we investigate the cryogenic toughness degradation which can be occurred for austenitic stainless in welding. The test materials are austenitic stainless JN1, JJ1 and JK2 steels, which are materials recently developed for use in nuclear fusion apparatus at cryogenic temperature. The small punch(SP) test was conducted to detect similar isothermally aging condition with material degradation occurred in service welding. The single-specimen unloading compliance method was used to determine toughness degradation caused by thermal aging for austenitic stainless steels. In addition, we have investigated size effect on fracture toughness by using 20% side-grooved 0.5TCT specimens.

  • PDF

Electorlyzed water as a disinfectant against foodborne pathogens in vegatables and kitchen apparatus

  • Chang, Tae-Eun;Shin, O-kyu;Jun, Dong-Wha;Lee, Tae-Seek;Kim, Poong-Ho;Shin, Il-Shik
    • 한국어업기술학회:학술대회논문집
    • /
    • 한국어업기술학회 2003년도 춘계 수산관련학회 공동학술대회발표요지집
    • /
    • pp.93-94
    • /
    • 2003
  • In recent, there are many report about nonthermal disinfection using electorlyzed water, Also, foodborne illnesses associated with pathogenic bacteria such as Listeria monocytogenes and Escherichia coli O157:H7 have raised concerns about the adequacy of disinfectants (Kim et at., 2000). Foodborne pathogens in vegetables and kitchen apparatus are not easy to disinfect but also hard to use chemical compounds for disinfection. (omitted)

  • PDF

PVDF 초음파 변환기의 제작과 특성에 관한 연구 (A Study on Fabrication and Characteristics of PVDF Ultrasonic Transducer)

  • 정홍량
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.33-37
    • /
    • 2000
  • The authors fabricated ultrasonic transducer with PVDF[poly(vinylidene fluoride)] piezoelectric polymer film. When impulse waves were applied to the PVDF ultrasonic transducer, the dependence of the response properties on the backing material with copper was investigated through not only theoretical calculations using Mason's equivalent circuit but also experimental measurements. The experimental pulse response properties agree with those of the theoretical calculations and the pulses were shorter than those for a PZT transducer. If such short-pulse properties are used in an medical ultrasonic image diagnosis apparatus, the resolution of the apparatus will be improved. When the insertion loss was calculated theoretically to the PVDF ultrasonic transducer, the frequency characteristics of its showed wideband frequency.

  • PDF

Tension Split Hopkinson bar를 이용한 자동차 성형용 금속 박판의 Johnson-Cook 구성방정식 결정 (Johnson-Cook constitutive relation of sheet metals for an auto-body with a tension split Hopkinson bar apparatus)

  • 강우종;조상순;허훈;정동택
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1997년도 추계학술대회논문집
    • /
    • pp.84-88
    • /
    • 1997
  • The Jonhnson-Cook constitutive relation has been used in dynamic plasticities. The constants of the Jonhson-Cook relation of sheet metals for an autobody is not known yet. In this paper, the material properties of SPCEN, SPCC and SPRC in the high strain rate states have been acquired. A new tension split Hopkinson bar was used in high speed tensile tests of sheet metals. The experimental results acquired from the apparatus are used to determine the constants of Johnson-Cook constitutive relation of sheet metals. This results can be used to analysis of crashworthness.

  • PDF

RP를 이용한 고차압밸브 디스크의 시제품 제작 시스템 확립 (Establishment of Prototyping System for Drag-Valve Disk Using RP)

  • 최민식;박문선;강범수
    • 한국정밀공학회지
    • /
    • 제15권3호
    • /
    • pp.61-67
    • /
    • 1998
  • Rapid prototyping becomes widely used in design and manufacturing of mechanical and aerospace engineering. Here a drag valve disk consisted of complicate configuration has designed by CAD, and prototyped by a stereolithography apparatus (SLA) to confirm the design configuration. Also the prototyped valve disk was used for checking if it could be applied for casting from the view point of accuracy, cost, and time. The rapid-prototyped disk by SLA was compared with a high-speed machined disk by MAKINO V55, and it is found that the prototyping of the disk by SLA appears more economical, more accurate and faster than by machining with MAKINO V55.

  • PDF

치과용 시술기구(Micro Handpiece)재료의 특성평가 및 표면품질에 대한 연구 (Study on Evaluation of Material Property of Micro Handpiece for dentistry and Surface Quality)

  • 손재환;한창우;최상일;김용중;최창진
    • 한국산업융합학회 논문집
    • /
    • 제9권3호
    • /
    • pp.221-228
    • /
    • 2006
  • As Industrialization gets more and more advanced, human technological medical apparatus for dentistry has been developed. Such a medical apparatus have to let precision revolution and torque control facilitate. Consequently, Development of Micro hand-piece with strong durability should be required. Moreover, It's also very important to evaluate performance of such a Micro hand-piece, Evaluation of Mechanical property of Material and ANOVA have been known as useful methods in the field of Quality Evaluation. For Verification of Quality Evaluation, It has been evaluated by One-way layout ANOVA based on the data of Surface Roughness Test. Anyhow, This test has been respectively carried out by 3 kinds of Test and Superior performance has appeared in the Test result.

  • PDF

진동형 분체 최소착화에너지측정장치의 특성

  • 최광석;정재희
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1998년도 추계 학술논문발표회 논문집
    • /
    • pp.179-182
    • /
    • 1998
  • It is widely recognized that conventional means for determining the minimum ignition energy(MIE) of powder are time-consuming and require operational skill. As a variety of new fine powders are being produced day by day in industry, there is an urgent need to a quicker and more economical means to measure MIE. To meet this requirement, we have developed a measurement system which employs a novel method to create an air/dust mixture in a miniature combustion box. In this system, the powder to be tested input into a hopper made of metal mesh, and successively fed downward to form a thin, curtain-like dust/air mixture by vibration. With this new apparatus, three type of powders -Lycopodium, Anthraquinone, and Polyacrylonitrile-were tested and the MIE data were compared with those taken with a conventional apparatus(the Hartmann tube). Two of them agreed satisfactory, but the other, anthraquinone, showed quite different values supposedly due to the agglomeration of the powder particles by static-charge.

  • PDF

피치 1.25mm 급 Wire to Board Connector 에서 조립상태로부터 분리거동에 관한 연구 (The Separation Behaviors from Assemble Conditions for Pitch 1.25mm Level Wire to Board Connector)

  • 허영무;윤길상
    • Design & Manufacturing
    • /
    • 제10권1호
    • /
    • pp.1-6
    • /
    • 2016
  • In this study, the modification structure design of insulation displacement connector developed was considered for simplification of assembly process. The modified connector consisted terminal, wafer and fitting nails. The separation behavior under locking condition for pitch 1.25mm wire to board connector was measured and the apparatus for the test was made. The maximum restraining force was measured about 4.5kgf that was bigger value than the specification limit. And the pulling force of a wire was also indicated about 2.3kgf.

브레이크 라이닝 패드의 마찰 진동 (Friction-Induced Vibration of Brake Lining Pad)

  • 최연선;정성균
    • 한국자동차공학회논문집
    • /
    • 제2권5호
    • /
    • pp.93-100
    • /
    • 1994
  • Friction-induced vibration characteristics of automotive brake lining pad are investigated on the basis of experimental observations from a pin-on-disk type friction-induced vibration experimental apparatus. The measured responses of the experimental apparatus show limit cycles of quasi-harmonics type and beat phenomena due to the velocity dependence of friction force. To deduce the friction coefficient vs. relative velocity Lienard method is adopted with least square fit. It shows Scurve which characterizes a quasi-harmonic vibration. The calculation of amplitudes and friquencies of the limit cycles is done using slowly changing phase and amplitude method. The theoretical and numerical results show fairly good agreements with those of experiments.

  • PDF