• 제목/요약/키워드: apex area

검색결과 194건 처리시간 0.025초

열연화시킨 근관충전방법에 따른 근단폐쇄성에 관한 연구 (A COMPARISON OF THE APICAL SEALING ABILITY OF OBTURATION TECHNIQUES BY THERMALLY SOFTENED GUTTA PERCHA)

  • 백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.607-617
    • /
    • 1998
  • The purpose of this study was to evaluate the apical sealing ability of lateral condensation method, vertical condensation method, and MicroSeal obturation system. Sixty-four extracted anterior teeth were instrumented to #40 using Profile. Three groups of 20 teeth were obturated by lateral condensation technique, vertical condensation technique, and and MicroSeal obturation system. Control group were not obturated. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were ground horizontally at 1,5mm(level 1), 2.5mm(level 2), and 3.5mm(level 3) from the anatomic apex and examined with a stereomicroscope at X40 magnification. The photographs were taken a at X40 magnification of the filling in each level and scanned. The leakage area, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was evaluated by calculating the ratio of thearea of the resin to the total area of the canal and was analyzed statistically. The results were as followed: 1. Vertical condensation group had significantly higher percentage of the area which was obturated by gutta percha than other two technique at each level. 2. At the level 1, there was the greatest leakage in the lateral condensation group, but there was no statistically significant(P>0.05) 3. At the level 2, there was the least leakage in the MicroSeal group, and the most leakage in the lateral condensation group. There was statistically significant difference between the MicroSeal group and the lateral condensation group(P<0.05). 4. At the level 3, there was least leakage in the vertical condensation group, and the most leakage in the lateral condensation group. There was statistically significant difference between the vertical condensation group and the lateral condensation group(P<0.05).

  • PDF

측방가압충전시 Nickel-Titanium spreader의 사용유무가 근관충전효과에 마치는 영향 (INFLUENCE OF NICKEL-TITANIUM SPREADER ON THE SEALING ABILITY IN LATERAL CONDENSATION TECHNIQUE)

  • 민경산;홍찬의;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.381-389
    • /
    • 2000
  • Lateral condensation with gutta-percha and sealer has been shown to provide an excellent apical seal; however, the lateral condensation technique has demonstrated less favorable apical leakage results in curved canals when compared with straight canals. Placement of endodontic spreaders to within 1 to 2mm of the root canal working length has been advocated for optimum gutta-percha obturation. Due to their stiffness, stainless-steel(SS) spreaders will often fail to achieve this position in curved canals. Newly marketed nickel-titanium(NT) spreaders may offer an advantage in this regard due to the increased flexibility of these instruments. The purpose of this study was to evaluate the effect of NT finger spreader on the sealing ability in lateral condensation technique, compared with conventional SS finger spreader. Twenty four standardized resin models simulating curved canals(30 degree) were randomly placed into 2 groups and instrumented to a #30 master apical file size with Ni-Ti Profile .04 taper series using step down technique. Each groups was obturated with standardized gutta-percha cone by standard lateral condensation technique using SS finger spreader, NT finger spreader. And then, each model was sectioned horizontally with microtome at 1, 2, 3, 4, 5mm levels from the apex. At each of 5 levels, ratio of the area of gutta-percha was obtained by calculating the area of gutta-percha to the total area of the canal. The data collected were then analyzed statistically using a t test for independent samples. The results as follows ; 1. The total mean ratio of area of gutta-percha was 89.20${\pm}$7.00(%) for SS spreader group. 92.20${\pm}$5.17(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). 2. At 3mm level, the mean ratio of area of gutta-percha was 88.32${\pm}$5.41(%) for SS spreader group, 95.25${\pm}$2.60(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). At 1,2,4mm levels, NT spreader group showed greater mean ratio of area of gutta-percha than SS spreader group, too. But there was no statistically significant difference. 3. At 5mm level, the mean ratio of area of gutta-percha was 91.83${\pm}$3.42(%) for SS spreader group, 87.91${\pm}$3.68(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). This study concluded that the NT spreader demonstrated somewhat favorable apical sealing effect than SS spreader in prepared curved canals. The clinical use of NT spreaders may enhance our ability to create better apical seals in curved canals, but further studies in this area will help clarify some of the remaining areas with which practitioners are concerned, such as compaction forces exerted by NT spreaders.

  • PDF

골내 임플랜트의 종류에 따른 광탄성 응력 분석 (PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY DIFFERENT TYPE ENDOSSEOUS IMPLANTS)

  • 정재헌;장두익
    • 대한치과보철학회지
    • /
    • 제31권4호
    • /
    • pp.661-678
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of endosseous implants. This investigation evaluated the stress patterns in rectangular photoelastic models produced by four different types of dental implants such as $Br\ddot{a}nemark$, screw type of Steri-Oss, blade type of Steri-Oss, IMZ with IMC and resin tooth using the techniques of quasi-three dimensional photoelasticity. All prostheses were casted in the same nonprecious alloy and were cemented or screwed on their respective implants and abutments. 20 kg of vertical load was applied on the central fossa of casted crown and 16 kg of inclined had was applied on the top third of distal surface of casted crown respectively. The results were as follows : 1. Under the vertical load, screw implants of Steri-Oss and $Br\ddot{a}nemark$ showed increasing stress condition between and around the screw threads along the implant lateral surface and cylindrical implant of IMZ showed the less stress condition along the lateral surface with concentration of stress mostly near the root apex. 2. Under the vertical load, the stress of Steri-Oss blade was distributed uniformly at the alveolar bone under the broad blade. 3. Under the inclined load, the stress concentration of Steri-Oss screw and $Br\ddot{a}nemark$ was developed highly around the mesiocervical bone area on the contralateral side to force application. The stress of $Br\ddot{a}nemark$ with flexible gold glod was more concentrated in the cervical bone area than that of Steri-Oss with stiff screw. 4. Under the inclined load, the stress of Steri-Oss blade broadly was distributed around the mesioceivical bone area and the lower and mesial bone area of the blade. 5. Under the Inclined load, IMZ implant showed the gap between c개wn and fixture due ta deformation of the IMC and IMZ was lower in stress concentration developed around the mesiocervical bone area than $Br\ddot{a}nemark$ and Steri-Oss screw. 6. Under the inclined load, the stress magnitude induced in the mesiocervical bone area of implants was in order of $Br\ddot{a}nemark$, Steri-Oss strew, IMZ and Stsri-Oss blade. 7. Tilting forces as compared to axial forces exerted greater magnitude of stress in the cervical bone area of the implant. 8. In respect of stress distribution, Steri-Oss blade was superior than any other implants and in respect of the stability by horizontal lone, IMB and $Br\ddot{a}nemark$ was inferior than any other implants.

  • PDF

3종류의 구치부 Uprighting Spring의 초기응력분포에 관한 광탄성학적 연구 (A PHOTOELASTIC STUDY ON THE INITIAL STRESS DISTRIBUTION BY 3 TYPES OF MOLAR UPRIGHITNG SPRING)

  • 전윤식
    • 대한치과교정학회지
    • /
    • 제24권3호
    • /
    • pp.709-719
    • /
    • 1994
  • The aim of this investigation was to identify which suing is more suitable for uprighting of the 30 degree inclined lower second molar in different situations. Between four different molar uprighting springs which were A, B, C type and T-loop spring, the author tested T-loop suing as a control material and the other springs were experimental group. Each spring was fabricated from .017' $\times$ .025' TMA wire and preactivated with 40 degree tip-back bend. Stabilizing unit included from the lower right central incisor to the lower right second premolar which were made by acrylic resin. The photoelastic overview of the lower right quadrant showed that stress concentrations were observed in its photoelastic model. The obtained results were as follows. 1. Higher concentration of compression can be seen clearly at the distal curvature than the mesial of the lower second molar when A type uprighting spring was applied, which can be used as a space regainer. 2. Higher level compression was presented at the mesial root apex area than the distal of the lower second molar in B type uprighting spring, which can be used as a space closer. 3. Areas of higher compression and tension were observed about the mesial and distal root of the lower second moalr than A and B type in C type uprighting spring, which can be used as a partial space regainer.

  • PDF

PIV를 이용한 분지관모델내 3차원 맥동유동의 가시화 (Three-Dimensional Flow Visualization of Pulsatile Flow in a Branching Model using the PIV System)

  • 성순경;조민태;노형운;서상호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.748-753
    • /
    • 2001
  • The objective of the present study is to visualize the pulsatile flow fields by using three-dimensional computer simulation and the PIV system. A closed flow loop system was built for the steady and unsteady experiments. The Harvard pulsatile pump was used to generate the pulsatile pressure and velocity waveforms. Conifer powder as the tracing particles was added to water to visualize the flow field. Two consecutive particle images were captured by a CCO camera for the image processing at several cross section. The range validation and the area interpolation methods were used to obtain the final velocity vectors with high accuracy. The finite volume predictions were used to analyze three-dimensional flow patterns in the bifurcation model. The results of the PIV experiment and the computer simulation are in good agreement and the results show the recirculation zones and formation of the paired secondary flow distal to the apex of the bifurcated model. The results also show that the branch flow is pushed strongly to the inner wall due to the inertial force effect and helical motions are generated as the flow proceeds toward the outer wall.

  • PDF

흉부X선사진(胸部X線寫眞)에 나타나는 감감현상(減感現象)에 관(關)한 연구(硏究) (A Study on Appearances of Desensitized Phenomenon in Chest Roentgenography)

  • 경광현;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제2권1호
    • /
    • pp.23-29
    • /
    • 1979
  • Roentgenographic film has to be handled with greatest care during removal from the packing, loading of the cassettes and loading of the hanger. In the case of prior to or after exposed film is handled with mechanical pressure in darkroom, the most common phenomena are desensitization or sensitization on roentgenographic film. In order to observe these defect occurring on, it, the author studied on change of the densities where the mechanical pressure reached to the roentgenographic film. 1. The optimal minimum and maximum densities in routine chest x-ray film are from 0.25 to 1.47 2. The dependence of the desensitization occurring on film upon the bent degree of film is in the portion to bent degree over $10^{\circ}$ 3. Appearances of the desensitization on film by the curved degree of film is inverse proportion to it's degree below intervals of 3cm. 4. The more unexposed film is bent with nail tip and is pressured with palm, the more desensitization it was appeared upon film size and pressure weight. 5. The most serious area of desensitization produced by many types of mechanical pressure is in the portion of lung apex and outside lung fields. 6. The tendency of desensitization due to mechanical pressure on unexposed film is more serious than sensitization on exposed film in the view of radiologic diagnosis.

  • PDF

A Study on Asymmetric Lifting Capacity Due to Spine Deformity

  • Oh, Hyunsoo;Chang, Seong Rok
    • International Journal of Safety
    • /
    • 제11권1호
    • /
    • pp.22-25
    • /
    • 2012
  • Scoliosis can be biomechanically described as a three dimensional deformity of the spine, with deviations from the physiologic curves in the sagittal and frontal planes, usually combined with intervertebral rotation. Various factors are suspected such as genetic defects, uneven growth of the vertebrae, hormonal effects, abnormal muscular activity, postural problems, or a mix of some of these elements, but its initial cause is known in only 15-20% cases. The screening test for diagnosing scoliosis is called the Adams Forward Bend Test. During the experiment, the subjects were asked to bend over, with arms dangling, until a curve could be observed. The Scoliometer was placed on the back of the subjects and used to measure the difference between the left and right apex of the curve in the thoracic, thoracolumbar and lumbar area. Then, the subjects were asked to perform Maximum Voluntary Contractions (MVCs) using the digital back muscle dynamometer in three different postures: (1) 0o (sagittally symmetric); (2) 30o from the mid-sagittal plane (clockwise); and (3) 30o from the mid-sagittal plane (counterclockwise). In addition to the experimental data, subject-dependent variables including Body Mass Index (BMI), percentage of body fat and muscle mass of left/right arms and legs were employed to reveal the cause of difference among three MVC conditions. All those variables were tested using statistical methods.

다색 망점 인쇄물의 색측정에서 농도 측정 방법과 자극치 직독 방법의 비교에 관한 연구 (A comparative Study on the Colorimeter and Densitometer Analysis in Color Measurement for Reproduced Colors Variable Dot Area Rates)

  • 구철회
    • 한국인쇄학회지
    • /
    • 제2권1호
    • /
    • pp.45-64
    • /
    • 1984
  • 다색 망점 인쇄물에서 색을 측정하는데는 여러가지 방벙이 있는데, 본 논문에서는 농도 측정법과 자극치 직독법으로, 본문 Ink 화학주식회사에서 나온 SPACE Color New Apex-G Color Chart를 사용하여 두 방법의 측정 결과를 비교, 검토하였다. Process Ink 인 Y, M, C, RI 을 10, 20, 30...90, 100% 의 망점 면적 비교로 변화시켜 측정한 결과 다음과 같은 결론을 얻었다. 1. Y Ink는 가장 이상적인 Ink로 575 nm부근의 주파장을 가졌다. 2. M Ink는 다른 성분을 제일 많이 함유하고 있었다. 3. 원색 분해할 때에 B1 판의 필요성이 확인되었다. 4. 색의 혼합 결과는 M+Y 의 혼합 때 가장 결과가 좋았다.

  • PDF

음극이 자동 정렬된 화산형 초미세 실리콘 전계방출 소자 제작 (Fabrication of Self -aligned volcano Shape Silicon Field Emitter)

  • 고태영;이상조;정복현;조형석;이승협;전동렬
    • 한국진공학회지
    • /
    • 제5권2호
    • /
    • pp.113-118
    • /
    • 1996
  • Aligning a cathode tip at the center of a gate hole is important in gated filed emission devices. We have fabricated a silicon field emitter using a following process so that a cathode and a gate hole are automatically aligned . After forming silicon tips on a silicon wafer, the wafer was covered with the $SiO_2$, gate metal, and photoresistive(PR) films. Because of the viscosity of the PR films, a spot where cathode tips were located protruded above the surface. By ashing the surface of the PR film, the gate metal above the tip apex was exposed when other area was still covered with the PR film. The exposed gate metal and subsequenlty the $SiO_2$ layer were selectively etched. The result produced a field emitter in which the gate film was in volcano shape and the cathode tip was located at the center of the gate hole. Computer simulation showed that the volcano shape and the cathode tip was located at the center of the gat hole. Computer simulation showed that the volcano shape emitter higher current and the electron beam which was focused better than the emitter for which the gate film was flat.

  • PDF

미세입자의 트라이볼로지적 응용을 위한 마찰특성 고찰 (Study on the Frictional Characteristics of Micro-particles for Tribological Application)

  • 성인하;한흥구;공호성
    • Tribology and Lubricants
    • /
    • 제25권2호
    • /
    • pp.81-85
    • /
    • 2009
  • Interests in micro/nano-particles have been greatly increasing due to their wide applications in various fields such as environmental and medical sciences as well as engineering. In order to obtain a fundamental understanding of the tribological characteristics at particle-surface contact interface, frictional behaviors according to load/pressure and materials were obtained by using atomic force microscope(AFM) cantilevers with different stiffnesses and tips. Lateral contact stiffnesses were observed in various tip-surface contact situations. Experimental results show that stick-slip friction behavior occurs even when the colloidal probes with a particle of a few micrometers in diameter, which have a relatively large contact area and lack a well-shaped apex, were used. This indicates that atomic stick-slip friction may be a more common phenomenon than it is currently thought to be. Also, experimental results were investigated by considering the competition between the stiffness of the interatomic potential across the interface and the elastic stiffnesses of the contacting materials and the force sensor itself.