A Study on Appearances of Desensitized Phenomenon in Chest Roentgenography

흉부X선사진(胸部X線寫眞)에 나타나는 감감현상(減感現象)에 관(關)한 연구(硏究)

  • Kyong, Kwang-Hyon (Dept. of Radiotechnology, Shin Heung Junior Health College) ;
  • Huh, Joon (Dept. of Radiotechnology, Shin Heung Junior Health College)
  • 경광현 (신흥보건전문대학 방사선과) ;
  • 허준 (신흥보건전문대학 방사선과)
  • Published : 1979.07.18

Abstract

Roentgenographic film has to be handled with greatest care during removal from the packing, loading of the cassettes and loading of the hanger. In the case of prior to or after exposed film is handled with mechanical pressure in darkroom, the most common phenomena are desensitization or sensitization on roentgenographic film. In order to observe these defect occurring on, it, the author studied on change of the densities where the mechanical pressure reached to the roentgenographic film. 1. The optimal minimum and maximum densities in routine chest x-ray film are from 0.25 to 1.47 2. The dependence of the desensitization occurring on film upon the bent degree of film is in the portion to bent degree over $10^{\circ}$ 3. Appearances of the desensitization on film by the curved degree of film is inverse proportion to it's degree below intervals of 3cm. 4. The more unexposed film is bent with nail tip and is pressured with palm, the more desensitization it was appeared upon film size and pressure weight. 5. The most serious area of desensitization produced by many types of mechanical pressure is in the portion of lung apex and outside lung fields. 6. The tendency of desensitization due to mechanical pressure on unexposed film is more serious than sensitization on exposed film in the view of radiologic diagnosis.

Keywords