• 제목/요약/키워드: aperture size

검색결과 308건 처리시간 0.027초

Dynamics of Nanopore on the Apex of the Pyramid

  • Choi, Seong-Soo;Yamaguchi, Tokuro;Park, Myoung-Jin;Kim, Sung-In;Kim, Kyung-Jin;Kim, Kun-Ho
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.187-187
    • /
    • 2012
  • In this report, the plasmonic nanopores of less than 5 nm diameter were fabricated on the apex of the pyramidal cavity array. The metallic pyramidal pit cavity can also utilized as the plasmonic bioreactor, and the fabricated Au or Al metallic nanopore can provide the controllable translocation speed down using the plasmonic optical force. Initially, the SiO2 nanopore on the pyramidal pit cavity were fabricated using conventional microfabrication techniques. Then, the metallic thin film was sputter-deposited, followed by surface modification of the nanometer thick membrane using FESEM, TEM and EPMA. The huge electron intensity of FESEM with ~microsecond scan speed can provide the rapid solid phase surface transformation. However, the moderate electron beam intensity from the normal TEM without high speed scanning can only provide the liquid phase surface modification. After metal deposition, the 100 nm diameter aperture using FIB beam drilling was obtained in order to obtain the uniform nano-aperture. Then, the nanometer size aperture was reduced down to ~50 nm using electron beam surface modification using high speed scanning FESEM. The followed EPMA electron beam exposure without high speed scanning presents the reduction of the nanosize aperture down to 10 nm. During these processes, the widening or the shrinking of the nanometer pore was observed depending upon the electron beam intensity. Finally, using 200 keV TEM, the diameter of the nanopore was successively down from 10 nm down to 1.5 nm.

  • PDF

다중 컬러필터 조리개 시스템을 위한 적응적 히스토그램 평활화를 이용한 영상 개선 (Image Enhancement Using Adaptive Region-based Histogram Equalization for Multiple Color-Filter Aperture System)

  • 이은성;강원석;김상진;백준기
    • 대한전자공학회논문지SP
    • /
    • 제48권2호
    • /
    • pp.65-73
    • /
    • 2011
  • 본 논문은 다중 컬러 필터 조리개 (multiple color-filter aperture; MCA) 시스템에서 영역 적응적 히스토그램 평활화를 사용하여 저노출 환경에서도 강건한 새로운 디지털 다중초점 (multifocusing) 방법을 소개한다. MCA 시스템은 획득된 영상의 컬러 채널 간에 발생하는 부정합 (misalignment) 정도를 측정하여 카메라의 거리에 따른 장면의 상대적 심도 정보를 추출한다. 추출된 상대적 심도 정보는 관심영역 (regsion-of-interests; ROIs) 분류 (classification), 정합 (registration), 융합 (fusion) 등의 과정을 통하여 다중초점 영상을 생성한다. 그러나 MCA 시스템은 유한한 구경의 조리개로 때문에 저노출 환경에서 성능의 저하를 초래하게 된다. 이러한 문제를 해결하기 위해 공간 적응적 히스토그램 확장을 이용한다. 실험결과에서 볼 수 있듯이, 제안한 기술은 저노출 환경에서도 콘트라스트가 향상된 다중초점 영상을 복원할 수 있음을 보여준다.

희박 어레이 기반의 효율적인 양방향 화소단위 집속 기법의 구현 (Efficient Implementation of Synthetic Aperture Imaging with Virtual Source Element in B-mode Ultrasound System Based on Sparse Array)

  • 김강식;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권6호
    • /
    • pp.419-430
    • /
    • 2002
  • 본 논문에서는 양방향 화소단위 집속 기법을 희박 어레이 기법을 사용하여 효율적으로 구현하는 방법에 대해 제안한다. 제안한 방법은 각 주사선을 구성할 때 합성에 이용되는 부구경 사이의 간격을 멀리함으로써 적은 수의 부구경으로 큰 크기의 합성구경을 형성하여 시스템의 복잡도를 감소시키면서 초음파 영상의 해상도와 프레임율을 향상시키게 된다. 하지만 이때 합성에 사용되는 부구경 사이의 간격 증가로 인해 그레이팅 로브 값은 상승하게 된다. 이러한 그레이팅 로브는 일반적인 합성구경 기법에서는 제거할 수 있다. 하지만 본 논문에서는 일반적인 합성구경 기법과는 달리 양방향 화소단위 집속 기법에서는 부구경 사이의 간격이 클 경우 발생하는 그레이팅 로브를 제거할 수 없음을 이론적으로 해석하였다. 또한 이러한 그레이팅 로브 값을 송신 집속점을 근거리에 위치시키고 합성에 사용되는 부구경간의 간격을 수신부구경의 크기에 비례하여 적절히 선택함으로써 의료용 초음파 영상에 적합한 -40dB 이하로 억제하는 방법과 조건을 제시하였다. 모의 생체와 실제 인체 실험 결과 제안한 방법을 통해 보다 적은 수의 부구경을 이용하여 더욱 빠른 프레임율의 양방향 화소단위 집속 기법의 구현이 가능함을 확인하였다

교육용 합성구경레이더 프로세서(eSAR Processor)의 개발과 공개 (Development and Distribution of an Educational Synthetic Aperture Radar(eSAR) Processor)

  • 이훈열
    • 대한원격탐사학회지
    • /
    • 제21권2호
    • /
    • pp.163-171
    • /
    • 2005
  • 합성구경레이더(Synthetic Aperture Radar) 원시 자료(raw data)를 range-Doppler 알고리듬을 이용하여 처리하는 교육용 공개 프로그램을 개발하였다 이 프로그램은 SAR 시스템에 따라 자료처리에 필요한 변수를 자유롭게 조절함으로써, 특정 SAR 시스템에 치우치지 않고 다양한 자료를 처리할 수 있도록 일반화된 알고리듬을 구현하였다. 저가 사양의 컴퓨터에서도 최소 단위의 영상을 선택적으로 처리할 수 있고 자료 처리 중간 단계별로 영상 출력이 가능하기 때문에, 프로그램 작동 상태와 SAR의 원리를 직접 확인할 수 있도록 하였다. 특히 Doppler 변수를 자료 처리 중간 단계의 영상을 보고 직접 구할 수 있도록 고안하여 교육적 효과를 높였다. 또한 자료 처리 알고리듬과 원시프로그램을 모두 공개함으로써, SAR 시스템 원리를 이해하고 응용하는데 도움을 주고자 한다. 이 논문에서는 프로그램의 원리와 작동 환경을 소개하고, ERS-1 원시 자료를 이용한 자료 처리의 예를 보였다.

A Ka-Band 6-W High Power MMIC Amplifier with High Linearity for VSAT Applications

  • Jeong, Jin-Cheol;Jang, Dong-Pil;Yom, In-Bok
    • ETRI Journal
    • /
    • 제35권3호
    • /
    • pp.546-549
    • /
    • 2013
  • A Ka-band 6-W high power microwave monolithic integrated circuit amplifier for use in a very small aperture terminal system requiring high linearity is designed and fabricated using commercial 0.15-${\mu}m$ GaAs pHEMT technology. This three-stage amplifier, with a chip size of 22.1 $mm^2$ can achieve a saturated output power of 6 W with a 21% power-added efficiency and 15-dB small signal gain over a frequency range of 28.5 GHz to 30.5 GHz. To obtain high linearity, the amplifier employs a class-A bias and demonstrates an output third-order intercept point of greater than 43.5 dBm over the above-mentioned frequency range.

외상성 횡경막 Hernia: 2례 보고 (Traumatic Diaphragmatic Hernia: A Report of Two Cases)

  • 김영태
    • Journal of Chest Surgery
    • /
    • 제6권2호
    • /
    • pp.237-242
    • /
    • 1973
  • Two cases of traumatic diaphragmatic hernia are reported, who were operated on in this department during the last 12 months` period. The first case, a 34 year old male, fell from 6 meters` height while he was working on electric pole. He sustained rib fractures, left 8th, 9th and 10th rib, left diaphragmatic rupture and ileal perforation. In the pleural cavity, there were stomach, omentum, left lobe of liver, transverse colon and ileum, which were reduced into the peritoneal cavity, and the diaphragmatic aperture was closed through anterolateral thoracotomy. After closure of the thoracic incision, median abdominal incision was made and closed the ileal perforation by primary suture. The second case was a 19 year old tyre repairman, who felt abrupt severe abdominal pain during lifting a heavy lyre. A barium study revealed a marked displacement of the stomach into the left pleural cavity. Immediately, thoracotomy was performed and closed the ruptured diaphragm after reduction of the herniated stomach, omentum, transverse colon, spleen and small intestine. The size of the diaphragmatic aperture were measured 17cm. in first case and 12cm. in the other respectively. Both cases discharged after uneventful recovery.

  • PDF

A High Aperture Mobile in the FFS TFT-LCD by the using Fine Patterning Process

  • Yun, Hee-Jung;Lim, Yun-Sik;Choi, Seung-Jin;Bin, Jin-Ho;Park, Jong-Kyun;Park, Min-Hwan;Lee, Yan-Ho;Ihm, Sam-Ho;Lim, Young-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.826-829
    • /
    • 2006
  • In order to increase the transmittance of panel, in process of FFS TFT-LCD, fine patterning process which is adopted to the optimum passivation(PVX) hole was applied fine metal line patterning process and was made with optimum efficiency of liquid crystal by using space/bar size control of pixel electrode. We fabricated 2.03" mobile FFS devices with fine patterning process. Further, this technology will be applied to the basis of other process for higher PPI or higher aperture ratio technology.

  • PDF

Auto-focus Control by Chromatic Filtering in Laser Welding

  • Kim, Cheol-Jung;Baik, Sung-Hoon;Kim, Min-Suk;Chung, Chin-Man;Kim, Kwang-Jung
    • Journal of the Optical Society of Korea
    • /
    • 제4권2호
    • /
    • pp.94-99
    • /
    • 2000
  • Optical monitoring using the chromatic aberration of focusing optics is applied to auto-focus control in laser welding. The spectral transmittance of thermal radiation from a weld pool through an aperture depends on the wavelength of the spectral band and on the distance of the weld pool from the focusing optics. Its dependence has been used to monitor the focus shift in laser welding by measuring the spectral band signals filtered by the aperture. The difference between pulsed and continuous laser welding is analyzed. Furthermore, the dependence of the focus shift monitoring on the weld pool size variation is optimized to monitor the focus shift independently from the laser power change at the weld pool. The performance of the auto-focus control with chromatic filtering is presented for pulsed laser welding.

Development of a 14.1 inch Full Color AMOLED Display with Top Emission Structure

  • Jung, J.H.;Goh, J.C.;Choi, B.R.;Chai, C.C.;Kim, H.;Lee, S.P.;Sung, U.C.;Ko, C.S.;Kim, N.D.;Chung, K.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.793-796
    • /
    • 2005
  • A structure and a design of device were developed to fabricate large-scale active matrix organic light-emitting diode (AMOLED) display with good color purity and high aperture ratio. With these technologies, we developed a full color 14.1 inch WXGA AMOLED display. For the integration of OLED on an active matrix a-Si TFT backplane, an efficient top emission OLED is essential since the TFT circuitry covers a large position of the pixel aperture. These technologies will enable up the OLED applications to larger size displays such as desktop monitors and TVs.

  • PDF

Parameter Selection Procedure of Parabolic Reflector Antenna for the Optimum Synthetic Aperture Radar Performances

  • Yoon, Seong Sik;Lee, Jae Wook;Lee, Taek Kyung;Yi, Dong Woo
    • Journal of electromagnetic engineering and science
    • /
    • 제13권4호
    • /
    • pp.251-258
    • /
    • 2013
  • A procedure for antenna parameter selections is proposed that considers the relationships between synthetic aperture radar performance and the antenna parameters of a parabola-type reflector antenna with a central flat dish. The effects of a central dish designed for weight reduction on the antenna beam pattern are also quantitatively analyzed using commercially available software based on the physical optics algorithm. The results of the theoretical analysis and simulation predict that a larger size of the central dish results in an increase in the sidelobe level, which is the reason for the increase in two important ambiguities, such as range ambiguity ratio (RAR) and azimuth ambiguity ratio (AAR). The dependence of RAR and AAR on Pulse repetition frequency is also analyzed and discussed.