• 제목/요약/키워드: antigen test kit

검색결과 59건 처리시간 0.025초

전립선특이항원검사 Kit에 의한 정액의 신속 검출법 (Forensic Evaluation of Prostate-Specific-Antigen (PSA) Rapid Test Kit for Identification of Human Semen)

  • 임채원;이종훈;김형락
    • 대한임상검사과학회지
    • /
    • 제41권2호
    • /
    • pp.76-82
    • /
    • 2009
  • It would be one of the most important tests that determination of semen in crime scene as a matter of significant evidences. Recently, it has been developed for the identification of semen in forensic specimens which was used simply, easily and reproductively. In this study, Prostate-Specific-Antigen (PSA) Rapid Test kit was evaluated for the forensic identification of semen and compared with one step semen inspection forensic rapid test kit. The sensitivity and specificity of the rapid PSA kit were examined in addition to the stability of PSA. The positive band of rapid PSA kit shown even with 1,000,000-fold diluted semen, which was at least 100 timed higher than qualitative one step semen inspection forensic rapid test kit. PSA was detected in urine from normal male adult, however, it was not detected in urine from young boys and female body fluids. It was shown that PSA was very stable to resist boiling for 20 minutes and the effect of bacteria. In crime scene investigation, rapid PSA kit is expected to help to identify semen easily in the evidences.

  • PDF

Latex 응집반응을 이용한 동물의 톡소플라즈마병 진단용 kit 개발에 관한 연구 (Development of diagnostic kit(Test-MT) for the microplate latex agglutination test of toxoplasmosis in animal)

  • 서명득;주후돈;데이빗 마-스
    • 대한수의학회지
    • /
    • 제35권3호
    • /
    • pp.583-593
    • /
    • 1995
  • The present study was conducted to develop a toxoplasma latex agglutination test antigen(Test-MT) and evaluate the toxoplasma latex agglutination(LA) test using a newly-made "Test-MT kit" by comparing with the Toxo-MT kit(Eiken chemical co, Tokyo). Also, the specifity and sensitivity test were made by comparing with IFA test and IgG-ELISA. Tachyzoite suspensions of Toxoplasma gondii(RH strain) were ultracentrifuged for 30min at $60,000{\times}g(4^{\circ}C)$ and the supernatant was used as a water-lysate antigen. Polystyrene latex particles of $1.0{\mu}m$ in diameter(Polyscience co) were used for the preparation of sensitized latex-antigen supension(Test-MT). The frequency distribution of LA titers in Test-MT showed two peaks at <1:32 and 1:128. The borderline titer for positive test in Test-MT was determined to be 1:64. But the frequency distribution of LA tites in Toxo-MT showed two peaks at <1:16 and 1:64. The positive borderline was determined to be 1:32. Agreement of reactions between Test-MT and Toxo-MT kit by LA test was shown 92.5% in bovine sera and 97.0% in swine sera, respectively. From the results obtained here it was determined that the sensitized latex-antigen, Test-MT kit, for the microtiter agglutination test prepared as same as by the procedure described in the previous paper(Suh and Lee, 1993) was useful as a highly specific, sensitive and stable immunotiteration reagent for serodiagnosis of toxoplasma infection in animal sera.

  • PDF

Clinical evaluation of a rapid diagnostic test kit for detection of canine coronavirus

  • Yoon, Seung-Jae;Seo, Kyoung-Won;Song, Kun-Ho
    • 대한수의학회지
    • /
    • 제58권1호
    • /
    • pp.27-31
    • /
    • 2018
  • Canine coronavirus is a single-stranded RNA virus that causes enteritis in dogs of any age. Coronaviral enteritis is seldom definitively diagnosed, since it is usually much less severe than many other types of enteritis and is self-limiting. Conventional diagnostics for the canine coronaviral enteritis such as polymerase chain reaction (PCR), virus isolation, and electron microscopic examination are inappropriate for small animal clinics due to the complicated experimental processes involved. Therefore, a commercially available lateral flow test kit based on chromatographic immunoassay techniques was tested to evaluate its performance as a first-line diagnostic test kit that could be used in clinics. The coronavirus antigen test kit detected canine coronavirus-infected dogs with 93.1% sensitivity and 97.5% specificity. The detection limit of the test kit was between $1.97{\times}10^4/mL$ and $9.85{\times}10^3/mL$ for samples with a 2-fold serial dilution from $1.25{\times}10^6\;TCID_{50}$ ($TCID_{50}$, 50% tissue culture infectious dose). Additionally, the test kit had no cross-reactivity with canine parvovirus, distemper virus, or Escherichia coli. Overall, the commercially available test kit showed good diagnostic performance in a clinical setting, with results similar to those from PCR, confirming their potential for convenient and accurate use in small animal clinics.

진돗개에서 개적혈구항원(dog erythrocyte antigen) 1 혈액형 조사 (Prevalence of dog erythrocyte antigen (DEA) 1 among Jindo dogs)

  • 이정치
    • 한국동물위생학회지
    • /
    • 제41권4호
    • /
    • pp.271-276
    • /
    • 2018
  • This study was conducted to investigate the prevalence of dog erythrocyte antigen (DEA) 1 with DEA 1.1 and DEA 1.2 on 122 Jindo dogs (29 males, 93 females) from 2014 to 2015 using a monoclonal antibody card kit (blood typing card kit, Korea Animal Blood Bank Inc., South Korea). Among the tested dogs, 14.8% (18/122) were positive for the DEA 1.1 antigen and 85.2% (104/122) were positive for the DEA 1.2 antigen. The prevalence of positive types for the DEA 1.2 antigen was significantly higher than the DEA 1.1 antigen (P<0.01). The prevalence of positive types for the DEA 1.1 antigen was higher in white-haired Jindo dogs than yellow-haired dogs (P<0.05). However, there was no gender difference in the prevalence of the DEA 1.1 antigen (P=0.665). The incidence of sensitization after the first transfusion without blood group test was 12.6% and the incidence of acute hemolytic transfusion reaction after the second transfusion in the same immunized dogs was 1.6%. Therefore, the blood group test for the DEA 1 antigen should be performed for Jindo dogs to ensure safe and effective transfusion therapy and further studies remain to be conducted for other DEAs among Jindo dogs.

Comparison of the non-invasive diagnostic methods, stool antigen test and PCR assay, for Helicobacter felis detection in dogs

  • Hong, Sunhwa;Lee, Hak-Yong;Kim, Tae-Wan;Kim, Okjin
    • 한국동물위생학회지
    • /
    • 제38권1호
    • /
    • pp.37-42
    • /
    • 2015
  • The aim of the present study was to compare the non-invasive methods for the diagnosis of H. felis with HpSA kit-based detection method and H. felis-specific PCR assay with dog's stool samples without sacrifice. Male Beagle dogs (n=6) were infected with H. felis ATCC 49179 ($1.0{\times}10^9CFU/dog$) by intra-gastric inoculation two times at 3-day intervals, and the stool specimens of dogs were collected 1, 3, 5, 7, 14, 21 days after infection to submit to HpSA test and H. felis-specific PCR. As the results, the sensitivity of the HpSA and the PCR analysis was 50.0%, 83.3% respectively. Although HpSA test is less sensitive, it could be used for rapid, cheap and easy screening assay for H. felis infection in dog and cats. We suggest that the H. pylori stool antigen kit, HpSA, is useful and effective for monitoring H. felis infection. If HpSA test would be made with H. felis antibodies in the future, its sensitivity could be increased. Also, PCR assay could be successfully used to detect the H. felis in stools. Applying the H. pylori stool antigen kit and PCR assay may be the recommended non-invasive strategy to identify H. felis in dog and cats.

Evaluation of Rapid Immunochromatographic Assay Kit for HBsAg-Screening Using Whole Blood

  • Shin, Hyeong-Soon;Heo, Tae-Ryeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제5권5호
    • /
    • pp.362-365
    • /
    • 2000
  • A rapid immunochromatographic assay kit using whole blood to screen hepatitis B surface antigen was developed and evaluated by using sera from 240 patients. The reference diagnosis was based on the results obtained with GENEDIA Anti-HBs Rapid kit which is very similar to the above kit except for the use of serum. The test demonstrated a good correlation with the reference immunochromatographic assay kit, that is, the sensitivity and the specificity of the kit was 100%, respectively. The rapid test kit using whole blood should be more convenient and useful for the diagnosis of hepatitis B virus because the kit does not need machines and time to prepare serum. In addition, this kit is safe from inadvertent infection during sample treatment because the blood is sterilized with hydrogen peroxide, eliminates the procedure required to prepare serum and reduces the possibility of exposure to infectious agents.

  • PDF

Hepatitis B Surface Antigen을 신속히 검출하기 위한 Immunochromatographic Assay kit의 성능 평가 (The Evaluation of Immunochromatographic Assay kit for Rapid Detection of Hepatitis B Surface Antigen)

  • 신형순;김영봉;신정우;김창규;이왕식;김한겸;신광순
    • 대한바이러스학회지
    • /
    • 제27권2호
    • /
    • pp.137-141
    • /
    • 1997
  • We evaluated Immunochromatographic assay kit to screen HBsAg in human serum. When the reference HBsAg was applyed to ICA, HA and EIA kits, the limit of detection for HBsAg were found out to be 4, 2 and 0.25 ng/ml respectively. But ICA kit required 5 minutes to read the result whereas HA and EIA kit more than one hour. The sensitivity was 97% (29 of 30 samples) and the specificity 100% (45 samples) compared with conventional EIA. The ICA kit needs no instrument or machine to perform the test contrary to the conventional methods. Therefore, this rapid and sensitive ICA kit can be used for HBsAg-screening, especially in the emergency room and in the scene of the accident.

  • PDF

영상 인식 기반 신속 인플루엔자 자동 판독 기법 개발 (Development of Automated Rapid Influenza Diagnostic Test Method Based on Image Recognition)

  • 이지은;주윤하;이정찬
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권3호
    • /
    • pp.97-104
    • /
    • 2019
  • To examine different types of influenza diagnostic test kits automatically, automated rapid influenza diagnostic test method based on image recognition is proposed in this paper. First, the proposed methods classify a variety of the rapid influenza diagnostic test kit based on support vector machine that analyzes the kits' feature point. Then, to improve the accuracy of test, the proposed methods match the histogram of both the target image of influenza kit and the input image of influenza kit for minimizing the effect of environment factors, such as lighting and exposure variations. And, to minimize the effect from composition of the hand-helds devices, the proposed methods extract the feature point and match point-by-point between target image of influenza kit and input image of influenza kit. Experimental results of 124 experimental group show that the proposed methods significantly have effectiveness, which shows 90% accuracy in moderate antigen, for the preliminary examination of influenza, and provides the opportunity for taking action against influenza.

인천 지역 사육견의 심장사상충 감염률 및 병리조직학적 연구 (Studies on infection rate and histopathological findings of canine heartworms in Inchon city)

  • 이성모;황현순;김종훈
    • 한국동물위생학회지
    • /
    • 제22권1호
    • /
    • pp.25-35
    • /
    • 1999
  • The prevalence of canine heartworm(Dirofilaria immitis) infection in 150 mixed-breed dogs(male : 54, female : 96) from February to December 1997 was investigated by using antigen test kit(ICT $GOLD^{TM}$ HW, Synbiotics, USA) based on immunochromatographic assay in Inchon city. Also, gross and histopathological findings of an antigen positive dog were carried out. The results were summarized as follows ; 1. Four dogs were positive from 150 tested dogs(2.7%). They were all more than 2 years old and infection rates in male and outdoor dogs was higher than those in female and indoor, respectively. Species of infected dogs were Pug(2) , German Sheperd(1) and Great-dane (1). 2. Regional infection rates were closely related with housing system in the city. 3. Pathological findings of antigen-positive dog was excessive enlargement, congestion and hemorrhage of lung and D immitis in heart and histologically hemosiderin, hypertrophy of pulmonary alveoli wall and irregular hypertrophy of pulmonary artery inner wall. Microfilaria was observed in pulmonary artery and arteriole, ventricle and splenic artery.

  • PDF

신속 FOB(분변 잠혈) 검사 키트를 이용한 혈흔 검출 및 인혈 검사 (Identification of human blood using Rapid FOB (Fecal Occult Blood) Test Kit)

  • 임시근;박기원;최상규
    • 분석과학
    • /
    • 제17권3호
    • /
    • pp.211-216
    • /
    • 2004
  • 본 연구는 분변 잠혈 검출 키트 (one-step FOB(Fecal Occult Blood) kit)가 법생물학적으로 매우 중요한 혈흔 검출 및 사람 혈흔 판정에 적용 가능한지 알아보고자 하였다. 먼저 FOB 키트의 민감도를 결정하고 기존의 혈흔 검사법인 LMG 검사와 비교한 결과 1,000,000배 희석된 혈액까지도 검출 되었는데 이는 LMG 검사에 비해 약100배 정도 예민한 것이었다. 다른 동물 혈액에 대한 교차 반응 여부를 실험한 결과 FOB 키트는 사람의 혈액과만 반응하여 높은 특이성을 보여주었다. 또한 혈액의 보관 온도 및 경과 시간의 영향, 고온 처리의 영향을 알아보았으며, LMG 및 Luminol 시약의 영향에 대해서도 실험하였다. 사람 혈액 특이 항원은 매우 높은 안정성을 보여주었으며, 전통적인 혈흔 검사 시약인 LMG 및 Luminol에 대해서도 영향을 받지 않았다. 따라서 FOB 키트는 LMG 검사 및 Luminol 검사와 병행하여 사용하면 보다 신속하고 정확하게 사람 혈흔 여부를 판정할 수 있어 법과학 실험실에서는 물론 사건 현장에서의 혈흔 검사에 크게 기여할 수 있을 것으로 사료된다.