• Title/Summary/Keyword: annual decrease

Search Result 510, Processing Time 0.027 seconds

The Change of Heating and Cooling Load according to the Thermal Insulation Performance of Window for an Apartment House (창호의 단열성능에 따른 공동주택 냉난방 부하량 변화)

  • Song, Su-Bin;Kim, Young-Tag;Yoon, Seong-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.853-856
    • /
    • 2008
  • Windows have an great effect on annual building load because windows are the weakest parts of building envelope thermally. To reduce the consumption of building energy, the thermal performance of window has to be improved in first place. Therefore this research aims to make a quantitative analysis of the heating and cooling load according to the window thermal performance using the heat load simulation program. As a result of the simulation, annual heat load is down 38% according to the decrease of U-value of window, 1.00 W/$m^2K$. and annual heat load is up 10% according to the decrease of shading coefficient, 0.20. The annual load of the window with Low-E glass is 15% lower than the window with pair glass.

  • PDF

Annual Change of Peak Expiratory Flow Rate in Asthma and COPD (천식환자 및 만성 폐쇄성 폐질환환자군에서 연간 최대 호기유속의 변화량)

  • Hong, Sung-Chul;Lee, Cho-I;Han, Jang-Soo;Kim, Won-Dong;Lee, Kye-Young;Kim, Sun-Jong;Kim, Hee-Joung;Ha, Kyoung-Won;Chon, Gyu-Rak;Yoo, Kwang-Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.1
    • /
    • pp.24-29
    • /
    • 2012
  • Background: Measurement of peak expiratory flow rate (PEFR) in a follow-up examination for a chronic airway disease is useful because it has the advantages of being a simple measurement and can be repeated during examination. The aim of this study was to examine the annual decrease of PEFR in asthma and chronic obstructive pulmonary disease (COPD) patients and to confirm the factors which influence this decrease. Methods: From May, 2003 to September, 2010, the annual decrease of PEFR was obtained from asthma and COPD patients attending an outpatient pulmonary clinic. PEFR was measured using a Mini-Wright peak flow meter (Clement Clarke International Ltd. UK), and we conducted an analysis of factors that influence the change of PEFR and its average values. Results: The results showed an annual decrease of $1.70{\pm}12.86$ L/min the asthmatic patients and an annual decrease of $10.3{\pm}7.32$ L/min in the COPD patients. Age and $FEV_1$ were the predictive factors influencing change in asthma, and $FEV_1$ and smoking were the predictive factors influencing change in COPD. Conclusion: We confirmed the annual decreasing PEFR in patients with chronic airway disease and identified factors that work in conjunction with $FEV_1$ to influence the change.

Cause Analysis of the Rising Temperature in Mixed City of Urban and Rural Area - Case of Miryang City, Kyongsangnamdo - (도농복합도시 온도상승 영향요인 분석 - 경남 밀야시를 대상으로 -)

  • Hong, Suk-Hwan
    • Korean Journal of Environment and Ecology
    • /
    • v.27 no.6
    • /
    • pp.757-764
    • /
    • 2013
  • This study was conducted to determine factors causing urban temperature rises in a mixed urban and rural city in Korea. The study site was Miryang City. For this study, temperature changes over a 36 year period from 1974 to 2010, as well as changes made in the urban environment of the city were examined. Changes in the urban environment included data pertaining to both urban development and changing land use, as well as the changing lifestyle patterns of the populace. The study showed that a rise in the average annual temperature and the average annual mean-maximum temperature were statistically significant and the greatest determining factor for the temperature rise was a corresponding decrease in arable land. The study also showed that the decrease in cultivated land was directly and significantly related to an expansion of regional urbanization. There is a direct relationship between the decrease in cultivated land and an increase in the annual-mean-maximum temperature compared with annual-mean temperature. This increase can be explained as arable land works as an "island" of cooler temperatures in the hottest times of the day. A decrease of $1km^2$ of arable land is expected to cause an increase of $0.08^{\circ}C$ of annual-maximum-mean temperature and $0.06^{\circ}C$ of annual-mean temperature.

Estimation of Annual Minimal Probable Precipitation Under Climate Change in Major Cities (기후변화에 따른 주요 도시의 연간 최소 확률강우량 추정)

  • Park, Kyoohong;Yu, Soonyu;Byambadorj, Elbegjargal
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.1
    • /
    • pp.51-58
    • /
    • 2016
  • On account of the increase in water demand and climate change, droughts are in great concern for water resources planning and management. In this study, rainfall characteristics with stationary and non-stationary perspectives were analyzed using Weibull distribution model with 40-year records of annual minimum rainfall depth collected in major cities of Korea. As a result, the non-stationary minimum probable rainfall was expected to decrease, compared with the stationary probable rainfall. The reliability of ${\xi}_1$, a variable reflecting the decrease of the minimum rainfall depth due to climate change, in Wonju, Daegu, and Busan was over 90%, indicating the probability that the minimal rainfall depths in those city decrease is high.

Influence of non-Gaussian characteristics of wind load on fatigue damage of wind turbine

  • Zhu, Ying;Shuang, Miao
    • Wind and Structures
    • /
    • v.31 no.3
    • /
    • pp.217-227
    • /
    • 2020
  • Based on translation models, both Gaussian and non-Gaussian wind fields are generated using spectral representation method for investigating the influence of non-Gaussian characteristics and directivity effect of wind load on fatigue damage of wind turbine. Using the blade aerodynamic model and multi-body dynamics, dynamic responses are calculated. Using linear damage accumulation theory and linear crack propagation theory, crack initiation life and crack propagation life are discussed with consideration of the joint probability density distribution of the wind direction and mean wind speed in detail. The result shows that non-Gaussian characteristics of wind load have less influence on fatigue life of wind turbine in the area with smaller annual mean wind speeds. Whereas, the influence becomes significant with the increase of the annual mean wind speed. When the annual mean wind speeds are 7 m/s and 9 m/s at hub height of 90 m, the crack initiation lives under softening non-Gaussian wind decrease by 10% compared with Gaussian wind fields or at higher hub height. The study indicates that the consideration of the influence of softening non-Gaussian characteristics of wind inflows can significantly decrease the fatigue life, and, if neglected, it can result in non-conservative fatigue life estimates for the areas with higher annual mean wind speeds.

Projection of the Future Wave Climate Changes Over the Western North Pacific (기후변화에 따른 북서태평양에서의 미래 파랑 전망)

  • Park, Jong Suk;Kang, KiRyong;Kang, Hyun-Suk;Kim, Young-Hwa
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.5
    • /
    • pp.267-275
    • /
    • 2013
  • This study projected the future ocean wave climate changes based on global climate change scenario using the coupled climate model HadGEM2-AO according to the emission scenarios and using regional wave model. Annual mean significant wave height (SWH) is linked closely to annual mean wind speed during the forthcoming 21st Century. Because annual mean speed decreased in the western North Pacific, annual mean SWH is projected to decrease in the future. The annual mean SWH decreases for the last 30 years of the 21st century relative to the period 1971-2000 are 2~7% for RCP4.5 and 4~11% for RCP8.5, respectively. Also, extreme SWH and wind speed are projected to decrease in the future. In terms of seasonal mean, winter extreme SWH shows similar trend with annual extreme SWH; however, that of summer shows large increasing tendency compared with current climate in the western North Pacific. Therefore, typhoon intensity in the future might be more severe in the future climate.

Comparison of Growth and Allometric Change of Stand and Dominant Trees in Pinus koraiensis Plantation over 34 Years

  • Seo, Yeongwan;Lee, Daesung;Chhorn, Vireak;Choi, Jungkee
    • Journal of Forest and Environmental Science
    • /
    • v.34 no.3
    • /
    • pp.235-241
    • /
    • 2018
  • This study was conducted to find out the growth pattern of Pinus koraiensis plantation over 34 years, focusing on DBH, height, basal area and allometric change. Total increment (TI), mean annual increment (MAI) and correlation coefficient were calculated and compared with stand and dominants. Total increment and mean annual increment of both DBH and height of dominants were bigger than those of stand. The difference was apparently shown bigger in DBH than height. Unlike DBH and height the total increment and mean annual increment of basal area per hectare of dominants were distinctively smaller than those of stand. Furthermore MAI of dominant was increasing until age 42, while MAI of stand increased at early ages and then gradually decreased after culmination like MAIs of DBH and height. MAIs of basal area of dead trees at each measurement tended to increase until early age (18 years in this study), while it reached a peak and gradually decrease after that (21 years in this study). Correlation coefficient between DBH and height tended to decrease as both dominant and stand age and the difference between dominant and stand was not clearly shown over the measurement period. Correlation coefficients between DBH and crown width tended to decrease as the trees age and correlation coefficients of dominant were clearly shown smaller than that of stand. Correlation coefficients of height and crown width also was found to be similar to correlation coefficients between DBH and crown. Meanwhile correlation coefficient of height and crown width dropped more radically than coefficient of DBH and crown width as the trees age.

Effect of Korean Red Ginseng intake on the survival duration of human immunodeficiency virus type 1 patients

  • Cho, Young-Keol;Kim, Jung-Eun
    • Journal of Ginseng Research
    • /
    • v.41 no.2
    • /
    • pp.222-226
    • /
    • 2017
  • Background: Long-term ginseng intake can increase longevity in healthy individuals. Here, we examined if long-term treatment with Panax ginseng Meyer (Korean Red Ginseng, KRG) can also enhance survival duration (SD) in patients with human immunodeficiency virus type 1 (HIV-1) infection. Methods: We retrospectively analyzed 252 HIV-1 patients diagnosed from 1986 to 2013 prior to the initiation of antiretroviral therapy. Overall, 162 patients were treated with KRG ($3,947{\pm}4,943g$) for $86{\pm}63$ mo. The effects of KRG on SD were analyzed according to the KRG intake level and the length of the follow-up period. Results: There were significant correlations between the total amount of KRG and SD in the KRG intake group (r = 0.64, p < 0.0001) as well as between total amount of KRG and mean annual decrease in $CD4^+$ T-cell count in all 252 patients (r = -0.17, p < 0.01). The annual decrease in $CD4^+$ T-cell count (change in $cells/{\mu}L$) was significantly slower in KRG-treated patients than in patients receiving no KRG ($48{\pm}40$ vs. $106{\pm}162$; p < 0.001). The SD (in months) was also significantly longer in the KRG group than in the no-KRG group ($101{\pm}64$ vs. $59{\pm}40$, p < 0.01). Conclusion: KRG prolongs survival in HIV-1 patients, possibly by slowing the decrease in $CD4^+$ T-cell count.

Epidemiologic Trends in Human Hepatitis A Virus Infection Stratified by Age between 2010 and 2018 in Cheonan, Korea

  • Jeon, Jae-Sik;Kim, Jae Kyung
    • Microbiology and Biotechnology Letters
    • /
    • v.48 no.4
    • /
    • pp.564-568
    • /
    • 2020
  • Although studies on Hepatitis A virus (HAV) were crucial in the establishment of the HAV infection prevention programs, no systematic investigation into HAV has been conducted since 1999. We retrospectively analyzed the data between January 2010 to December 2018 from all the patients who underwent HAV antibody tests at the Dankook University Hospital Health Care Center. Data were collected from 56,204 individuals. Overall, 34,834 (62.0%) individuals from this cohort were positive for HAV antibodies and the annual rate of anti-HAV antibody positivity was highest in 2010 (68.5%) and lowest in 2013 (54.8%). The average decline in the antibody positivity rate was 0.62% per year, showing a statistically significant difference (p < 0.001). In the over 40s age group, anti-HAV antibody positivity rates decreased from 89% in 2010 to 64% in 2018 (p < 0.001), with an annual decrease of 3.1%. In the over 30s age group, it decreased from 48.2% in 2010 to 34.7% in 2018 (p < 0.001), with an annual decrease of 1.82%. This study shows that the antibody positivity rate is decreasing across age groups but given that HAV infection poses more significant risks in older patients it is important to expand the evaluations of the current and future antibody positivity rates for HAV in various age groups.

Energy Performance Analysis of Solar Hot Water Heating System used in an Office Building Using the Dynamic Simulation (시뮬레이션을 이용한 사무소건물 적용 태양열 급탕시스템의 에너지성능 분석)

  • Ko, Myeong-Jin;Choi, Doo-Sung;Kim, Yong-Shik
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.281-285
    • /
    • 2009
  • This paper is to simulate a solar hot water heating system used in a medium-scale office building using the dynamic simulation. This study is focused chiefly on the annual variation of energy performance, the solar fraction with respect to the difference of hot water load temperature. For this purpose the simple model of a solar hot water heating system has been considered with TRNSYS program and the simulations were performed with the weather data in Seoul, Korea. The share ratio of solar hot water system of the summer season appeared higher than the winter season because that the decrease of the domestic hot water load was far despite the relative decrease of the solar radiation. As the temperature was lower from $60^{\circ}C$ to $50^{\circ}C$, the solar fraction increases 8.1 percent due to 20-percent decrease of annual hot water load.

  • PDF