• Title/Summary/Keyword: anion exchanger

Search Result 53, Processing Time 0.028 seconds

A Case of Idiopathic Renal Hypouricemia with SLC22A12 Gene Mutation Showing General Weakness and Incidental Renal Stone

  • Joung, Jin Woon;Song, Young Wha;Kim, Jong Dae;Cheon, Eun Jung
    • Childhood Kidney Diseases
    • /
    • v.25 no.1
    • /
    • pp.44-48
    • /
    • 2021
  • Idiopathic renal hypouricemia (iRHUC) is a rare hereditary disease caused by a defect in urate handling of renal tubules. Type 1 renal hypouricemia (RHUC1) is diagnosed with confirmation of a mutation in SLC22A12 gene which encodes a renal urate-anion exchanger (URAT1). The majority of iRHUC patients are asymptomatic, especially during childhood, and thus many cases go undiagnosed or they are diagnosed late in older age with complications of hematuria, renal stones, or acute kidney injury (AKI). We report a case of a 7-year-old boy with subtle symptoms such as general weakness and dizziness and revealed hypouricemia and incidental nephrolithiasis. Homozygous mutations were detected in the SLC22A12 (c.774G>A) by molecular analysis. The present case suggests that fractional excretion of uric acid (FEUA) screening could be better followed by the coincidental discovery of hypouricemia, to prevent conflicting complications of iRHUC, even with normal urine uric acid to creatinine ratio (UUA/UCr), and sequential genetic analysis if needed.

Synthesis of Bead Type lon Exchangers and Selective Adsorption Properties of Carbonyl Compounds in Cigarette Mainstream Smoke (비드형 이온교환체의 합성 및 담배 주류연 중 카보닐 화합물의 선택 흡착 특성)

  • Lee, John-Tae;Park, Jin-Won;Rhee, Moon-Soo;Hwang, Keon-Joong;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.29 no.1
    • /
    • pp.74-80
    • /
    • 2005
  • To use the filter materials for reduction of carbonyl compounds in cigarette mainstream smoke, the bead type cation and anion exchangers were synthesized by the suspension polymerization of GMA and DVB followed by the subsequent functionalization with sodium sulfite and diethylamine, respectively. FT-IR/ATR was used to characterize functionalized copolymer formation by sulfonation and amination, and the morphology change of ion exchangers according to the adsorption of cigarette mainstream smoke were observed by SEM. Ion exchange capacity, functionalization yield and adsorption properties of carbonyl compounds in cigarette mainstream smoke were investigated. The highest functionalization yields and ion exchange capacity were obtained at 5 wt% DVB content in co-monomer. The adsorption amount of carbonyl compounds in cigarette mainstream smoke of anion exchanger was higher than that of cation exchanger because of its electron delocalization in carbonyl group. The adsorption efficiency was increased in the presence of moisture. This results indicated that the anion exchanger was applicable for cigarette filter material because of its large ion exchange capacity and rapid ion exchange reaction.

Enantioseparation of Neutral Compounds on a Quinine Carbamate-Immobilized Zirconia in Reversed-Phase Capillary Electrochromatography

  • Lee, Mun-Rak;Gwon, Ju-Rim;Park, Jung-Hag
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.1
    • /
    • pp.82-86
    • /
    • 2010
  • Quinine (QN) is a weak anion-exchange type chiral selector and QN-based silica stationary phases have been widely used for enantioseparation of acidic chiral analytes in HPLC and recently in CEC. In this work we report enantioseparation of non-acidic chiral analytes on a quinine carbamate-immobilized zirconia (QNZ) in reversed-phase (RP) CEC. Influences of pH, composition of the buffer, acetonitrile content and the applied voltage on enantioseparation were examined. Enantiomers of the analytes investigated are well separated in acetonitrile/phosphate buffer mobile phases. Separation data on QNZ were compared to those on QN-bonded silica (QNS). Retention was longer but better enantioselectivity and resolution were obtained on QNZ than QNS.

New Analytical Method for Separation and Identification of Heavy Metals (I) (중금속의 분리 및 검출을 위한 분석화학적 연구 (제 1 보). 새로운 분리방법의 개발)

  • Kim, Youn-Doo;Bae, Jun-Heon;Shin, Young-Kook
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.3
    • /
    • pp.231-235
    • /
    • 1987
  • In 10M chloride (4M HCl + 6M LiCl) solution, cobalt, but not nickel, formed complex anion (${CoCl_3}^-$), and this anion was extracted by a liquid anion exchanger with Amberlite LA-2. The ion exchange capacity was 2.175meq of cobalt complex per unit ml of Amberlite LA-2. Upon eluting the resin with 0.4M nitric acid, the cobalt complex was stripped and transfered into eluate quantitatively. By using this separation method in the chloride solution dissolved with 50mg of cobalt (II) and 500mg of nikel(II), recovery of cobalt were 99.6 percent.

  • PDF

Sorption of Thiocyanate Silver Complexes and Determination of Silver by Diffuse Reflectance Spectroscopy

  • Kononova, O.N.;Goryaeva, N.G.;Vorontsova, T.V.;Bulavskaya, T.A.;Kachin, S.V.;Kholmogorov, A.G.
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.11
    • /
    • pp.1832-1838
    • /
    • 2006
  • The present paper is focused on sorption concentration of silver (I) on some complex-forming ion exchangers in the initial thiocyanate form and subsequent determination of Ag(I) in the phase of anion exchanger AN-25 by diffuse reflectance spectroscopy. The sorption and kinetic characteristics of the sorbents were investigated. The apparent stability constants of thiocyanate silver complexes in the ion exchanger phase were calculated. The sorption-spectroscopic method is proposed for Ag(I) determination in aqueous solutions. The calibration curve is linear in the concentration range of 10-200 mg/L (sample volume is 10.0 mL) and the detection limit is 2 $\mu$g/mL. The presence of $Na^+,\;K^+,\;Mg^{2+}$ (macrocomponents) as well as of Ni (II), Co (II), Cu (II) do not hinder the determination of silver (I).

Synthesis of Multifunctional AN-co-(MMA/IA) Fibrous ion-exchanger by Hydrolysis and Adsorption Properties for Trace Transition Elements (가수분해에 의한 AN-co-(MMA(IA) 다관능성 섬유이온교환체의 합성 및 미랑 전이금속 흡착특성)

  • 황택성;이선아;황계순
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.765-773
    • /
    • 2001
  • In In order to remove harmful trace elements such as $Co^{2+}$, $Ni^{2+}$ , $Cr_2O_7\;^{2-}$ from water, we synthesized AN-co-(MMA/IA) according to various mole ratio of monomers and spun by wet-spinning. And multi-functional PAN ion exchangers were prepared by hydrolysis. We observed structure, degree of functionalization, ion exchange capacity, distribution coefficient and mechanical properties for ion exchanger. Anion exchange capacity decreased in 4.5 ~ 4.2 meq/g with increasing of IA content and cation exchange capacity increased in 1.8 ~ 2.2 meq/g. Tensile strength of the ion exchanger increased up to 0.008 mol% IA content and appeared maximum value by 216$kg/cm^2$Distribution coefficient for AN-co-(MMA/IA) ion exchanger appeared maximum value for Co(II), Ni(II) in pH 5-6 range and for Cr(III) in pH 3-4 range. And the adsorption capacity was in the order of Cr(III) > Co(II) > Ni(II) for multicomponent in continuous process.

  • PDF

Optimization of SELDI-TOF MS for Peptide Profiling of Sorghum Seed (수수종자의 펩타이드 분석을 위한 SELDI-TOF MS 최적화 연구)

  • Park, Sei Joon;Park, June Young;Lee, Yong Ho;Hwang, Su Min;Kim, A Ram;Ko, Jee-Yeon;Kim, Tae Wan
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.58 no.1
    • /
    • pp.50-56
    • /
    • 2013
  • For accurate analysis of low molecular peptides using SELDI-TOF MS (surface enhanced laser desorption/ionization time of flight mass spectrometry), the optimized analytical conditions should be established for a specific biological sample. This study was conducted to optimize SELDI-TOF MS analytical conditions for profiling low molecular peptide below 10 kDa presented in sorghum seeds. Analytical conditions were as follows; (1) protein chips: CM10 (weak cation exchanger) and Q10 (strong anion exchanger), (2) dilution factors of binding buffer: 1/2, 1/5, 1/10, 1/20, 1/50, 1/100, and 1/200, (3) the stringency of Q10 binding buffer: 10 mM and 100 mM, and (4) protein extraction buffers: sodium borate, sodium borate + acetone, phenol, and TCA buffers. Optimum dilution factors were selected as 1/20 and 1/50 in both protein chips, CM10 and Q10. Low stringency of Q10 binding buffer (10mM) detected more peptide peaks than high stringency (100 mM). Selected protein extraction buffers of sorghum seed for SELDI-TOF MS analysis was the sodium borate buffer in the range of 2~10 kDa, while the phenol buffer was more suitable in the range of 10~20 kDa.

Synthesis of Aminated GMA-DVB Copolymer and Their Adsorption Properties for Nitrate (아민화 GMA-DVB 공중합체의 합성과 질소 성분에 대한 흡착 특성)

  • 황택성;이선아;이면주
    • Polymer(Korea)
    • /
    • v.25 no.3
    • /
    • pp.311-317
    • /
    • 2001
  • In this study, we synthesized bead-type GMA-DVB copolymer using glycidylmethacrylate (GMA) with high reactivity and hydrophilicity. Macrorecticular anion exchanger containing the trimethylammonium group were then prepared by amination with trimethylammonium chloride. We observed that the size of $NO_3^-$ is smaller than that of $SO_4^{2-}$ which disturb $NO_3^-$ removal in most of coexistent anions in ground water. Thus we investigated selective affinity for $NO_3^-$ and properties of individual ion exchangers with various DVB content. For each resins, we confirmed formation of copolymer by FT-IR spectrometer and investigated ion exchange capacity, swelling ratio, the amination yield and the effect with degree of crosslinking on adsorbability for nitrate. When amount of DVB is 4 wt%, amination yield, ion exchange capacity and swelling ratio was 384.3%, 3.25 meq/g and 77.1%, respectively. In these result, it can found that synthetic optimal condition is 4 wt% DVB content for monomer.

  • PDF

Removal Properties of NOx by Hybrid Anion Exchanger (복합 음이온교환 수지를 이용한 NOx 제거 특성)

  • Song, Sang-Hun;Lee, Hyung-Keun;Park, Bo-Ryeung;Hwang, Eui-Hwan;Lee, Bum-Jae;Hwang, Taek-Sung
    • Applied Chemistry for Engineering
    • /
    • v.17 no.6
    • /
    • pp.653-657
    • /
    • 2006
  • The adsorption properties for $NO_{2}$ by hybrid ion exchange fiber with resins were investigated. The adsorption of $NO_{2}$ was increased with increasing of adsorption time and the initial concentration. At the initial $NO_{2}$ concentration of 900 ppm, approximately 40% of initial $NO_{2}$ was adsorbed around 20 min. And the adsorption of $NO_{2}$ was decreased with increasing of flow rate from 20 to 40 L/min. The maximum adsorbed amount of initial $NO_{2}$ was 45% at the flow rate of 10 L/min. The amount of adsorption was increased with increasing the water content.

Expression of Anion Exchanger and CFTR in the Hepatocyte and Cholangiocytes in Bile Duct-Ligated Rat (담관 결찰 쥐의 간세포와 담관세포의 anion exchanger와 CFTR 발현)

  • Lee, Jae-Dong;Wang, Joon-Ho;Ki, Seung-Seog;Choe, Won-Hyeok;Park, Jae-Seung;Cho, Won-Kyoo;Park, Jung-Jun;Kim, Hong-Su
    • Journal of Life Science
    • /
    • v.21 no.12
    • /
    • pp.1772-1777
    • /
    • 2011
  • Cystic fibrosis transmembrane conductance regulator (CFTR) gene and sodium-independent $Cl^-/HCO_3^-$ anion exchanger (AE) genes are expressed in a wide variety of mammalian tissues including cholangiocytes. They play an important role in the regulation of intracellular pH (pHi) as well as in transepithelial acid/base transport necessary for biliary bicarbonate secretion. The aim of this study was to examine the expression level of CFTR gene and AE genes (AE1, AE2 and AE3) in the cholangiocytes and the hepatocytes, and also measure AE2 gene expression level after bile duct ligation (BDL). As we previously described, isolated hepatocytes and cholangiocytes from the liver of normal and BDL rats were prepared and gene expression levels were measured by using RT-PCR. We found that AE1, AE2, and AE3 genes were expressed in both hepatocytes and cholangiocytes, but CFTR was only in cholangiocytes. AE2 gene expression level was higher in the BDL hepatocytes than normal hepatocytes, which was significantly different between two groups. AE2 gene expression level was lower in the BDL cholangiocytes than normal cholangiocytes. However, AE2 gene expression level in both hepatocytes and cholangiocytes were not changed with a longer duration of BDL. These results suggest that CFTR and AE2 may play an important role in the pathogenetic mechanism of biliary cholestatic liver disease.