• 제목/요약/키워드: anion exchanger

검색결과 53건 처리시간 0.027초

A Case of Idiopathic Renal Hypouricemia with SLC22A12 Gene Mutation Showing General Weakness and Incidental Renal Stone

  • Joung, Jin Woon;Song, Young Wha;Kim, Jong Dae;Cheon, Eun Jung
    • Childhood Kidney Diseases
    • /
    • 제25권1호
    • /
    • pp.44-48
    • /
    • 2021
  • Idiopathic renal hypouricemia (iRHUC) is a rare hereditary disease caused by a defect in urate handling of renal tubules. Type 1 renal hypouricemia (RHUC1) is diagnosed with confirmation of a mutation in SLC22A12 gene which encodes a renal urate-anion exchanger (URAT1). The majority of iRHUC patients are asymptomatic, especially during childhood, and thus many cases go undiagnosed or they are diagnosed late in older age with complications of hematuria, renal stones, or acute kidney injury (AKI). We report a case of a 7-year-old boy with subtle symptoms such as general weakness and dizziness and revealed hypouricemia and incidental nephrolithiasis. Homozygous mutations were detected in the SLC22A12 (c.774G>A) by molecular analysis. The present case suggests that fractional excretion of uric acid (FEUA) screening could be better followed by the coincidental discovery of hypouricemia, to prevent conflicting complications of iRHUC, even with normal urine uric acid to creatinine ratio (UUA/UCr), and sequential genetic analysis if needed.

비드형 이온교환체의 합성 및 담배 주류연 중 카보닐 화합물의 선택 흡착 특성 (Synthesis of Bead Type lon Exchangers and Selective Adsorption Properties of Carbonyl Compounds in Cigarette Mainstream Smoke)

  • 이존태;박진원;이문수;황건중;황택성
    • 폴리머
    • /
    • 제29권1호
    • /
    • pp.74-80
    • /
    • 2005
  • 담배 주류연 중 카보닐 화합물의 감소를 위한 필터 물질로 비드 형상의 양이온 및 음이온교환체를 glycidylmethacrylate(GMA)와 d9ivinylbenzene(DVB)의 현탁중합에 의해 중합체를 합성한 후 설폰화 반응 및 아민화 반응에 의해 합성하였다. 합성한 이온교환체의 구조는 FT-IR/ATR을 이용하여 확인하였으며 SEM을 이용하여 주류연 흡착에 따른 이온교환체의 표면을 관찰하였다. 또한 이온교환용량, 관능화율 및 담배 주류연 중 카보닐 화합물의 흡착 특성을 확인하였다. 관능화율과 이온교환용량은 공단량체 중 DVB의 함량이 5 wt%에서 최대를 나타내었다. 이온교환체에 의한 담배 주류연 중 카보닐 흡착량은 카보닐기 내의 전자 편재화에 의한 음이온교환반응이 더 용이하여 음이온교환체에서 더 높게 나타났으며, 수분 존재 시 더 많은 흡착량을 나타내었다. 또한 짧은 접촉 시간에서도 높은 흡착량을 가지고 있어 궐련 필터의 적용 가능성을 확인할 수 있었다.

Enantioseparation of Neutral Compounds on a Quinine Carbamate-Immobilized Zirconia in Reversed-Phase Capillary Electrochromatography

  • Lee, Mun-Rak;Gwon, Ju-Rim;Park, Jung-Hag
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권1호
    • /
    • pp.82-86
    • /
    • 2010
  • Quinine (QN) is a weak anion-exchange type chiral selector and QN-based silica stationary phases have been widely used for enantioseparation of acidic chiral analytes in HPLC and recently in CEC. In this work we report enantioseparation of non-acidic chiral analytes on a quinine carbamate-immobilized zirconia (QNZ) in reversed-phase (RP) CEC. Influences of pH, composition of the buffer, acetonitrile content and the applied voltage on enantioseparation were examined. Enantiomers of the analytes investigated are well separated in acetonitrile/phosphate buffer mobile phases. Separation data on QNZ were compared to those on QN-bonded silica (QNS). Retention was longer but better enantioselectivity and resolution were obtained on QNZ than QNS.

중금속의 분리 및 검출을 위한 분석화학적 연구 (제 1 보). 새로운 분리방법의 개발 (New Analytical Method for Separation and Identification of Heavy Metals (I))

  • 김연두;배준현;신영국
    • 대한화학회지
    • /
    • 제31권3호
    • /
    • pp.231-235
    • /
    • 1987
  • 니켈중 미량의 코발트를 분리하는데 액상음이온교환수지인 Amberlite LA-2를 이용하였다. 10M 염소이온 (4M HCl + 6M LiCl) 용액중에서 코발트는 ${CoCl_3}^-$를 형성하여 Amberlite LA-2 1ml에 2.175meq 추출되었다. 그러나 같은 조건의 염소이온용액에서 니켈은 착음이온을 형성하지 않으므로 전연 추출되지 않았다. 수지층에 추출된 코발트는 0.4M 질산용액에 의해 정량적으로 용리되었다. 코발트 50mg과 니켈 500mg을 녹인 합성시료용액중에 본 분리 방법을 적용시킨 결과 99.6%의 코발트를 분리회수 하였다.

  • PDF

Sorption of Thiocyanate Silver Complexes and Determination of Silver by Diffuse Reflectance Spectroscopy

  • Kononova, O.N.;Goryaeva, N.G.;Vorontsova, T.V.;Bulavskaya, T.A.;Kachin, S.V.;Kholmogorov, A.G.
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권11호
    • /
    • pp.1832-1838
    • /
    • 2006
  • The present paper is focused on sorption concentration of silver (I) on some complex-forming ion exchangers in the initial thiocyanate form and subsequent determination of Ag(I) in the phase of anion exchanger AN-25 by diffuse reflectance spectroscopy. The sorption and kinetic characteristics of the sorbents were investigated. The apparent stability constants of thiocyanate silver complexes in the ion exchanger phase were calculated. The sorption-spectroscopic method is proposed for Ag(I) determination in aqueous solutions. The calibration curve is linear in the concentration range of 10-200 mg/L (sample volume is 10.0 mL) and the detection limit is 2 $\mu$g/mL. The presence of $Na^+,\;K^+,\;Mg^{2+}$ (macrocomponents) as well as of Ni (II), Co (II), Cu (II) do not hinder the determination of silver (I).

가수분해에 의한 AN-co-(MMA(IA) 다관능성 섬유이온교환체의 합성 및 미랑 전이금속 흡착특성 (Synthesis of Multifunctional AN-co-(MMA/IA) Fibrous ion-exchanger by Hydrolysis and Adsorption Properties for Trace Transition Elements)

  • 황택성;이선아;황계순
    • 폴리머
    • /
    • 제25권6호
    • /
    • pp.765-773
    • /
    • 2001
  • 본 연구에서는 수중의 $Co^{2+}$, $Ni^{2+}$ , $Cr_2O_7\;^{2-}$등의 유해이온을 선택적으로 흡착 제거시키기 위하여 단량체의 몰비를 달리하여 AN-co-(MMA/IA)를 합성하고, 습식방사에 의해 제조한 PAN 섬유를 산가수분해하여 PAN계 다관능성 이온교환섬유를 합성하였다. 또한 합성한 이온교환섬유의 구조, 관능화도, 이온교환용량, 분포계수. 기계적 물성 등을 시험하였다. 이온교환체의 음이온교환 용량은 IA의 mole 함량이 증가함에 따라 4.5~4.2 meq/g으로 감소하고, 양이온교환용량은 1.8-2.2 meq/g으로 증가하는 경향을 보였다. 인장감도는 공중합체 내에 IA의 함량이 0.008 mol%까지 증가하여 216 $kg/cm^2$로 최대값을 나타냈고, AN-co-(MMA/IA) 이온교환체의 분포계수 측정 결과 Co(II)와 Ni(II)는 pH 5-6영역에서 최대를 보였고, Cr(III)는 pH 3-4에서 최대값을 나타냈다. 또한 다성분 계상에서의 연속식 흡착 실험에서 Cr(III > Co(II) > Ni(II)의 순으로 선택능을 나타냈다.

  • PDF

수수종자의 펩타이드 분석을 위한 SELDI-TOF MS 최적화 연구 (Optimization of SELDI-TOF MS for Peptide Profiling of Sorghum Seed)

  • 박세준;박준영;이용호;황수민;김아람;고지연;김태완
    • 한국작물학회지
    • /
    • 제58권1호
    • /
    • pp.50-56
    • /
    • 2013
  • SELDI-TOF MS를 활용한 저분자 펩타이드 분석을 위해서는 분석시료에 대한 최적화 분석조건을 확립하는 것이 필수적으로 선행되어야 한다. 본 연구는 수수 종자 내 존재하는 10 kDa 이하의 저분자 펩타이드를 프로파일링하기 위하여 활용된 SELDI-TOF MS의 최적화 분석조건을 확립하는데 있다. 분석조건은 (1) 프로테인 칩: CM10(weak cation exchanger), Q10(strong anion exchanger), (2) 바인딩 버퍼의 희석배수: 1/2, 1/5, 1/10, 1/20, 1/50, 1/100, 1/200, (3) Q10의 바인딩 버퍼 강도: 10 mM, 100 mM, (4) 단백질 추출버퍼: sodium borate, sodium borate + acetone, phenol, TCA 버퍼로 하였다. 1. 바인딩 버퍼의 희석배수는 CM10과 Q10 모두 1/20과 1/50이 최적화로 나타났다. 2. Q10의 바인딩 버퍼 강도는 농도가 약한 10 mM에서 더 많은 피크가 검출되었다. 3. SELDI-TOF MS 분석에 적합한 수수 종자단백질 추출 버퍼로는 2~10 kDa 범위에서는 sodium borate 버퍼와 10~20 kDa 범위에서는 phenol 버퍼로 분석되었다.

아민화 GMA-DVB 공중합체의 합성과 질소 성분에 대한 흡착 특성 (Synthesis of Aminated GMA-DVB Copolymer and Their Adsorption Properties for Nitrate)

  • 황택성;이선아;이면주
    • 폴리머
    • /
    • 제25권3호
    • /
    • pp.311-317
    • /
    • 2001
  • 본 연구에서는 반응성이 큰 친수성 단량체인 glycidylmethacrylate (GMA)를 이용하여 현탁중합법으로 bead type의 GMA-DVB 공중합체를 제조하고, 이들 공중합체를 trimethyl-ammonium chloride로 아민화하여 trimethylammonium기를 갖는 거대망상형 음이온 교환수지를 합성하였다. 여기서 지하수에 공존하는 음이온 중 $NO_3^-$ 제거에 가장 방해가 되는 $SO_4^{2-}$ 이 입체적으로 크다는 것에 착안하여 가교제인 divinylbenzene (DVB)의 양을 변화시켜 가교도에 따른 음이온에 대한 선택능을 확인하였고, 각각의 수지에 대한 물성과 $NO_3^-$ 에 대한 흡착능을 고찰하였다. 또한 FT-IR을 통하여 공중합체의 합성여부를 확인하였고, 또한 아민화 수율, 이온교환 용량 및 팽윤율을 평가하여 가교도에 따른 영향을 조사하였다. 여기서 DVB의 함량이 4wt%일 때 아민화 수율은 384.3%, 이온교환용량은 3.25 meq/g, 팽윤율은 77.1%로 가장 최적으로 나타났다.

  • PDF

복합 음이온교환 수지를 이용한 NOx 제거 특성 (Removal Properties of NOx by Hybrid Anion Exchanger)

  • 송상헌;이형근;박보령;황의환;이범재;황택성
    • 공업화학
    • /
    • 제17권6호
    • /
    • pp.653-657
    • /
    • 2006
  • 본 연구는 이온교환 수지와 섬유를 복합한 이온교환체를 이용하여 $NO_{2}$의 흡착특성을 고찰하였다. 수지량의 변화에 따른 $NO_{2}$의 흡착은 흡착시간이 경과함에 따라 증가하였다. 초기농도 변화에 따른 $NO_{2}$ 흡착은 초기 농도가 증가함에 따라 흡착량이 증가하였으며 900 ppm의 경우 20 min 내외에 약 40% 흡착되었다. 한편 유속변화에 따른 $NO_{2}$의 흡착은 유속이 증가함에 20~40 L/min까지 흡착량은 감소하였고, 유속이 10 L/min에서 최대 45% 흡착되었으며, 함수율 변화에 따른 $NO_{2}$ 흡착량은 10 min 전후에서 약 15%로 매우 낮게 나타났다.

담관 결찰 쥐의 간세포와 담관세포의 anion exchanger와 CFTR 발현 (Expression of Anion Exchanger and CFTR in the Hepatocyte and Cholangiocytes in Bile Duct-Ligated Rat)

  • 이재동;왕준호;기승석;최원혁;박재승;조원규;박정준;김홍수
    • 생명과학회지
    • /
    • 제21권12호
    • /
    • pp.1772-1777
    • /
    • 2011
  • 본 연구는 흰쥐의 담관 세포와 간세포에서 CFTR과 $AE1{\cdot}AE2{\cdot}AE3$ 유전자들의 발현 유무를 조사하고 흰쥐에서 담관 결찰 후 AE2 유전자의 발현의 변화를 관찰하고자 하였다. 200-250 g의 Sprague Dawley 계 흰쥐 24마리의 총담관을 결찰한 후 4 주 동안 1 주일에 6마리씩 희생하여 간세포와 담관 세포를 분리하였다. 6마리는 대조군으로 사용하여 간세포와 담관 세포에서 CFTR 유전자와 $AE1{\cdot}AE2$와 AE3 유전자 발현을 조사하고 담관 결찰 후 1 2 3 4주 간격으로 AE2 유전자 발현을 조사하였다. $AE1{\cdot}AE2$ 와 AE3는 간세포와 담관 세포에서 발현되었고 CFTR은 담관 세포에서만 발현되었다. 담관 결찰 담관세포군에서 AE2 유전자의 발현은 대조군인 정상 담관세포군에 비해서 낮았다. 결찰 담관세포군에서 AE2 유전자의 발현은 결찰 기간에 따라 차이가 없었다. 담관 결찰 간세포군에서 AE2 유전자의 발현은 대조군인 정상 간세포군에 비해서 경계적 유의성을 보이며 증가하는 경향이 있었다. 결찰 간세포군에서 AE2 유전자의 발현은 결찰 기간에 따라 차이는 없었다. 따라서 $CFTR{\cdot}AE1{\cdot}AE2$ 그리고AE3 는 간세포와 담관 세포에서 중탄산염이온과 수액을 매개하는 주된 이온 전달체라는 사실을 고려할 때 담도 담즙정체 간질환에서CFTR과 AE2 발현의 변화는 병리학적 기전에 중요한 역할을 할 수 있으리라고 생각된다.