• Title/Summary/Keyword: angular measure

Search Result 229, Processing Time 0.022 seconds

Dynamics of a Micro Three-axis Ring Gyroscope Considering Electrode Effects (전극 효과를 고려한 마이크로 3축 링 자이로스코프의 동역학)

  • 김창부;강태민
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.1
    • /
    • pp.64-72
    • /
    • 2004
  • In this paper. we analyse and present electro-mechanical dynamic characteristics of a micro-machined vibrating silicon ring gyroscope which can measure angular velocities about three orthogonal axes. The ring gyroscope has a ring connected to the gyroscope main body by support-ligaments which are arranged with cyclic symmetry. The natural modes of its vibration can be distinguished into the in-plane motion and the out-of-plane motion which are coupled by the gyro-effect due to the rotation of the gyroscope main body. The motions of the ring are electro-statically derived. sensed and balanced by electrodes. The equations of motion are formulated. The measuring method of angular velocities by force-to-rebalance is presented. The dynamic characteristics of a ring gyroscope are calculated and compared.

Dynamics of a Micro Three-Axis Ring Gyroscope (마이크로 3축 링 자이로스코프의 동역학)

  • Choi, Sang-Hyun;Kim, Chang-Boo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.37-43
    • /
    • 2002
  • In this paper, we analyse and present mechanical dynamic characteristics of a micro-machined vibrating silicon ring gyroscope which can measure angular velocities about three orthogonal axes. The ring gyroscope has a ring connected to the gyroscope main body by support-ligaments which are arranged with cyclic symmetry. The natural modes of its vibration can be distinguished into the in-plane motion and the out-of-plane motion which are coupled by the gyro-effect due to the rotation of the gyroscope main body. The equations of motion, the response to angular velocities, and the relationships between the natural modes of vibration are derived and compared with the previous studies for the design of a micro three-axis ring gyroscope.

  • PDF

Dynamics of a Micro Three-Axis Ring Gyroscope Considering Electrode Effects (전극 효과를 고려한 마이크로 3축 링 자이로스코프의 동역학)

  • 강태민;김창부
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.970-976
    • /
    • 2003
  • In this paper, we analyse and present electro-mechanical dynamic characteristics of a micro-machined vibrating silicon ring gyroscope which can measure angular velocities about three orthogonal axes. The ring gyroscope has a ring connected to the gyroscope main body by support-ligaments which are arranged with cyclic symmetry. The natural modes of its vibration can be distinguished into the in-plane motion and the out-of-plane motion which are coupled by the gyro-effect due to the notation of the gyroscope main body. The motions of the ring are electro-statically derived, sensed and balanced by electrodes. The equations of motion are formulated. The scheme of angular velocities sensing by force-to-rebalance method is presented. The dynamic characteristics of a ring gyroscope are calculated and compared.

  • PDF

Temperature Characteristics of High Speed Angular Contact Ball Bearing (고속 앵귤러 컨택트 볼 베어링의 온도특성)

  • Hyeon, Jun-Su;Park, Tae-Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.96-101
    • /
    • 2001
  • This paper shows the temperature characteristics of a high speed angular contact ball gearing which is 7004C type with ISO P2 tolerance class. A built-in motor type high speed spindle which adopts an oil-air lubrication system was used to measure the temperature rise up to 60,000rpm. The gearing temperature was measured using thermocouples that were attached to the outside surfaces of the outer rings. The result showed that the continuous test method which was suggested in this paper is more effective than on and off method and the lubrication oil supply rate should be reduced in high speed rolling bearings as long as the seizure does not occur. And the result were confirmed that the bearings packed with ceramic balls are superior to those with steel balls in temperature characteristics.

  • PDF

Dynamics of a Micro Three-axis Ring Gyroscope (마이크로 3축 링 자이로스코프의 동역학)

  • Kim, Chang-Boo;Choi, Sang-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1001-1009
    • /
    • 2002
  • In this paper, we analyse and present mechanical dynamic characteristics of a micro-machined vibrating silicon ring gyroscope which can measure angular velocities about three orthogonal axes. The ring gyroscope has a ring connected to the gyroscope main body by support-ligaments which are arranged with cyclic symmetry. The natural modes of its vibration can be distinguished into the in-plane motion and the out-of-plane motion which are coupled by the gyro-effect due to the rotation of the gyroscope main body. The equations of motion, the response to angular velocities, and the relationships between the natural modes of vibration are derived and compared with the previous studies for the design of a micro three-axis ring gyroscope.

An Analysis on the Reduction of Measurement Time Using Interpolation Algorithm in Near-field RCS Measurements for Aircraft Shape (항공기 형상에 대한 근전계 RCS 측정에서 내삽 알고리즘을 이용한 측정시간 단축에 대한 분석)

  • Park, Homin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.339-346
    • /
    • 2022
  • The importance of stealth technology is increasing in modern warfare, and Radar Cross Section(RCS) is widely used as an indicator of stealth technology. It is useful to measure RCS using an image-based near-field to far-field transformation algorithm in short-range monostatic conditions. However, the near-field measurement system requires a longer measurement time compared to other methods. In this work, it is proposed to reduce the measured data using an interpolation method in azimuth angular domain. The calculated far-field RCS values according to the sampling rate is shown, and the performance of the algorithm applied with interpolation in the angular domain is presented. It is shown that measurement samples can be reduced several times by using the redundancy in the angular domain while producing results similar to the conventional method.

The Isokinetic Strength Evaluation of Trunk Flexors and Extensors by Contranction Type (체간 굴곡근과 신전근의 수축 형태에 따른 등속성 근력평가)

  • Kim Yang-Hee;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.10 no.2
    • /
    • pp.57-69
    • /
    • 1998
  • The role of eccentric muscle activities in functional everyday activities and sport is important and equally significant to concentric conditions. Eccentric and concentric exercise and evaluation are, therefore, very important. The purposes of this study were to measure eccentric md concentric peak torgue, percentage of peak torque, average power and percentage of average power of trunk flexors and extensors by using the Cybex NORM isokinetic dynamometer, and to standardize the value obtained. Thirty four young volunteers were tested, 17 females and 17 males, who had no history of back pain or abnormality. Each subjects were tested on three repetitions for isokinetic concentric and eccentric contraction at 5 velocities. The results were as follows; 1) Peak torque percent body weight of eccentric contraction were significantly greater than concentric contraction at each angular velocity and in trunk flexors and extensors(p<0.01). 2) Peak torque percent body weight of concentric contraction were significantly decreased as the angular velocity increased both male and female(p<0.01). 3) Peak torque percent body weight of eccentric contraction were not significantly changed as the angular velocity increased both male and female(p<0.05), 4) Peak torque percent body weight of male were significantly greater than female at each angular velocity and in concentric and eccentric contraction of trunk flexors and extensors(p<0.01)

  • PDF

Development and physiological assessments of multimedia avian esophageal catheter system

  • Nakada, Kaoru;Hata, Jun-ichi
    • Journal of Multimedia Information System
    • /
    • v.5 no.2
    • /
    • pp.121-130
    • /
    • 2018
  • We developed multimedia esophageal catheters for use with birds to measure and record ECG and angular velocity while anesthesized, at rest, and in flight. These catheters enable estimates of blood pressure based on readings given by an angular velocity sensor and by RR intervals of ECG affected by EMG. In our experiments, the catheters had the following characteristics: 1. Esophageal catheters offer a topological advantage with 8-dB SNR improvement due to elimination of electromyography (EMG). 2. We observed a very strong correlation between blood pressure and the angular velocity of esophageal catheter axial rotation. 3. The impulse conduction pathway (Purkinje fibers) of the cardiac ventricle has a direction opposite to that of the mammalian pathway. 4. Sympathetic nerves predominate in flight, and RR interval variations are strongly suppressed. The electrophysiological data obtained by this study provided especially the state of the avian autonomic nervous system activity, so we can suspect individual's health condition. If the change of the RR interval was small, we can perform an isolation or screening from the group that prevent the pandemics of avian influenza. This catheter shall be useful to analysis an avian autonomic system, to perform a screening, and to make a positive policy against the massive infected avian influenza.

Shape Description and Retrieval Using Included-Angular Ternary Pattern

  • Xu, Guoqing;Xiao, Ke;Li, Chen
    • Journal of Information Processing Systems
    • /
    • v.15 no.4
    • /
    • pp.737-747
    • /
    • 2019
  • Shape description is an important and fundamental issue in content-based image retrieval (CBIR), and a number of shape description methods have been reported in the literature. For shape description, both global information and local contour variations play important roles. In this paper a new included-angular ternary pattern (IATP) based shape descriptor is proposed for shape image retrieval. For each point on the shape contour, IATP is derived from its neighbor points, and IATP has good properties for shape description. IATP is intrinsically invariant to rotation, translation and scaling. To enhance the description capability, multiscale IATP histogram is presented to describe both local and global information of shape. Then multiscale IATP histogram is combined with included-angular histogram for efficient shape retrieval. In the matching stage, cosine distance is used to measure shape features' similarity. Image retrieval experiments are conducted on the standard MPEG-7 shape database and Swedish leaf database. And the shape image retrieval performance of the proposed method is compared with other shape descriptors using the standard evaluation method. The experimental results of shape retrieval indicate that the proposed method reaches higher precision at the same recall value compared with other description method.

Effects of Osteotomy Angle on Tibial Angulation and Torsion During CORA-Based Leveling Osteotomy in Toy Breed Dogs: A Computer Modeling-Based Study

  • Jeong, Youngeun;Jeong, Jaemin;Cho, Cheongwoon;Jeong, SeongMok;Lee, Hae Beom
    • Journal of Veterinary Clinics
    • /
    • v.37 no.4
    • /
    • pp.175-179
    • /
    • 2020
  • The objective of this study was to determine the effect of osteotomy angle and tibial proximal segment rotation angle on angular and torsional tibial deformities and to assess the trends of these deformities during the rotation of the tibial proximal segment in a center of rotation of angulation (CORA)-based leveling osteotomy (CBLO) by performing computer modeling of the tibia. Four tibias of toy breed dogs with no history of lameness were used in this study. Osteotomies were performed in the proximal tibias at angles of 0°, 10°, 20°, -10°, and -20°, perpendicular to either the proximodistal or craniocaudal tibial axes. The mechanical medial proximal tibial angle (mMPTA) and transcondylar (TC) and distal cranial tibial (CnT) axes were used to measure angular and torsional deformities, respectively. All tibias showed an increase in angular and rotational deformities with an increase in the tibial plateau rotation angle. The tibia with osteotomies performed in the proximodistal and craniocaudal directions showed the highest magnitude of torsional and angular deformities, respectively. The results of this study revealed a tendency of occurrence of angular and torsional deformities with osteotomy performed along the proximodistal and craniocaudal directions in the CBLO.