• Title/Summary/Keyword: angular dependence

Search Result 122, Processing Time 0.023 seconds

Dynamic Analysis of Spindle Supported by Multiple Bearings of Different Types (복합베어링으로 지지된 스핀들의 동적 해석)

  • Tong, Van-Canh;Bae, Gyu-Hyun;Hong, Seong-Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.2
    • /
    • pp.117-125
    • /
    • 2015
  • This paper presents a dynamic modeling method for the indeterminate spindle-bearing system supported by multiple bearings of different types. A spindle-bearing system supported by ball and cylindrical roller bearings is considered. The de Mul's bearing model is extended for calculating ball and cylindrical roller bearing stiffness matrices with inclusion of centrifugal force and gyroscopic moment. The dependence between spindle shaft reaction forces and bearing stiffness is effectively resolved using an iterative approach. The spindle rotor dynamics is established with the Timoshenko beam theory based finite elements. The spindle reaction forces, bearings stiffness and spindle natural frequencies are obtained with taking into account spindle radial load, ball bearing axial preload and rotational speed effects. The developed method is verified by comparing the simulation results with those from a commercial program.

Flux Pinning in $MgB_2$ Film with Columnar Grains (기둥형 결정립 구조를 지닌 $MgB_2$ 박막에서 자속고정 현상)

  • Kim, D.H.;Kim, H.Y.;Hwang, T.J.;Lee, S.H.;Seong, W.K.;Kang, W.N.
    • Progress in Superconductivity
    • /
    • v.9 no.2
    • /
    • pp.173-176
    • /
    • 2008
  • [ $MgB_2$ ] films grown by hybrid physical chemical vapor deposition under appropriate growth conditions commonly exhibit columnar grain structure. The grain boundaries between adjacent columnar grains have been reported to be good flux pinning centers. In this work, we measured the angular dependence of critical current density ($J_c$) and observed the enhanced flux pinning when an external magnetic field was aligned parallel to the columnar direction. This $J_c$ was almost comparable to the $J_c$ for intrinsic pinning case up to 1 T at low temperatures, indicating that grain boundary pinning is very effective. At high fields, however, $J_c$ decreased rapidly resulting from the fact that the density of flux pinning centers provided by grain boundaries was outnumbered by the flux density.

  • PDF

Magnetoresistance changes of sputtered NiFe thin films with deposition temperatures (NiFe 박막의 증착온도에 따른 MR 특성)

  • 이원재;백성관;민복기;송재성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.355-358
    • /
    • 2000
  • Magnetoresistance changes of NiFe thin films were investigated as a function of deposition temperature. DC magnetron sputtering was employed to fabricate Ta/NiFe(t)/Ta thin films on Si(001) substrates with in-situ field or with no-field. The thickness(t) of NiFe films was a range of 4 to 15nm. Substrate temperature was a range of 30 to 400$^{\circ}C$. MR measurement was carried out as a function of angle $\theta$, between external field and current direction. MR ratio increased with increasing substrate temperature, also, max. MR ratio was observed in samples deposited at 300$^{\circ}C$. With increasing upto 400$^{\circ}C$, MR ratio was rapidly decreased in the case of thinner NiFe films. In non-field deposited NiFe films, both angle $\theta$=0, 90。, there was no significant change in MR curves. However, MR curves of in-situ field deposited NiFe films were different in both angles $\theta$=0 and 90。

  • PDF

Proton and Deuteron Spin-Lattice Relaxation in Gaseous HD (HD 기체에서의 수소 및 중수소 원자핵 스핀-격자 완화시간에 관한 핵자기공명 연구)

  • ;R. E. Norberg
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.1
    • /
    • pp.52-55
    • /
    • 1994
  • The proton and deuteron spin-lattice relaxation times, $T_{1}(H)$ and $T_{1}(D)$, have been measured in HD between 30 K and 313 K in the pressure of 0.67 - 1.92 atm. The nuclear magnetic resonance frequencies are respectively 358.012 MHz for a proton and 58.958 MHz for a deuteron. From the measurements of $T_{1}(H)$ and $T_{1}(D)$ the ratio of the correlation times ${\tau}_{1}\;and\;{\tau}_{2}$ that are associated with the molecular angular momentum operators was obtained. The nuclear spin-lattice relaxation time at J = 1 state has been observed to have a temperature dependence being proportional to $T^{0.25}$.

  • PDF

CORE-JET BLENDING EFFECTS IN ACTIVE GALACTIC NUCLEI UNDER THE KOREAN VLBI NETWORK VIEW AT 43 GHZ

  • Algaba, Juan-Carlos;Hodgson, Jeffrey;Kang, Sin-Cheol;Kim, Dae-Won;Kim, Jae-Young;Lee, Jee Won;Lee, Sang-Sung;Trippe, Sascha
    • Journal of The Korean Astronomical Society
    • /
    • v.52 no.2
    • /
    • pp.31-40
    • /
    • 2019
  • A long standing problem in the study of Active Galactic Nuclei (AGNs) is that the observed VLBI core is in fact a blending of the actual AGN core (classically defined by the ${\tau}=1$ surface) and the upstream regions of the jet or optically thin flows. This blending may cause some biases in the observables of the core, such as its flux density, size or brightness temperature, which may lead to misleading interpretation of the derived quantities and physics. We study the effects of such blending under the view of the Korean VLBI Network (KVN) for a sample of AGNs at 43 GHz by comparing their observed properties with observations obtained using the Very Large Baseline Array (VLBA). Our results suggest that the observed core sizes are a factor ~ 11 larger than these of VLBA, which is similar to the factor expected by considering the different resolutions of the two facilities. We suggest the use of this factor to consider blending effects in KVN measurements. Other parameters, such as flux density or brightness temperature, seem to possess a more complicated dependence.

Measurement uncertainty analysis of radiophotoluminescent glass dosimeter reader system based on GD-352M for estimation of protection quantity

  • Kim, Jae Seok;Park, Byeong Ryong;Yoo, Jaeryong;Ha, Wi-Ho;Jang, Seongjae;Jang, Won Il;Cho, Gyu Seok;Kim, Hyun;Chang, Insu;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.479-485
    • /
    • 2022
  • At the Korea Institute of Radiological and Medical Sciences, physical human phantoms were developed to evaluate various radiation protection quantities, based on the mesh-type reference computational phantoms of the International Commission on Radiological Protection. The physical human phantoms were fabricated such that a radiophotoluminescent glass dosimeter (RPLGD) with a Tin filter, namely GD-352M, could be inserted into them. A Tin filter is used to eliminate the overestimated signals in low-energy photons below 100 keV. The measurement uncertainty of the RPLGD reader system based on GD-352M should be analyzed for obtaining reliable protection quantities before using it for practical applications. Generally, the measurement uncertainty of RPLGD systems without Tin filters is analyzed for quality assurance of radiotherapy units using a high-energy photon beam. However, in this study, the measurement uncertainty of GD-352M was analyzed for evaluating the protection quantities. The measurement uncertainty factors in the RPLGD include the reference irradiation, regression curve, reproducibility, uniformity, energy dependence, and angular dependence, as described by the International Organization for Standardization (ISO). These factors were calculated using the Guide to the Expression of Uncertainty in Measurement method, applying ISO/ASTM standards 51261(2013), 51707(2015), and SS-ISO 22127(2019). The measurement uncertainties of the RPLGD reader system with a coverage factor of k = 2 were calculated to be 9.26% from 0.005 to 1 Gy and 8.16% from 1 to 10 Gy. A blind test was conducted to validate the RPLGD reader system, which demonstrated that the readout doses included blind doses of 0.1, 1, 2, and 5 Gy. Overall, the En values were considered satisfactory.

Exchange Bias Study by FMR Measurment (강자성 공명에 의한 Exchange Bias 연구)

  • Yoo, Yong-Goo;Park, Nam-Seok;Min, Seong-Gi;Yu, Seong-Cho
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.5
    • /
    • pp.265-269
    • /
    • 2005
  • Exchange bias effect of a various layered thin films were studied by FMR measurment. In plane angular dependence of a resonance field distribution which measured by FMR was analysed as a combined effect of an unidirectional anisotropy and an uniaxial anisotropy. Exchange biased NiFe/IrMn, IrMn/NiFe/IrMn, and NiFe/IrMn/CoFe thin films showed larger unidirectional anisotropy field and uniaxial anisotropy field with compared to that of an unbiased NiFe single thin film. In case of NiFe/Cu/IrMn, the film with thick Cu layer exhibited a similar trend to the unbiased NiFe thin film. NiFe/IrMn/CoFe thin film showed two resonance field distribution due to different ferromagnetic layers. In additon to the resonance field, the line width was also analysed with related to exchange bias effect.

ESR Study on Paramagnetic Defects of the $gamma$-irradiated Ammonium Sulfate Single Crystal (${\gamma}$-선에 조사된 황산 암모늄 단결정의 상자성 결함에 관한 전자스핀공명 연구)

  • Yo Chul Hyun;Kim Eun Ok
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.80-87
    • /
    • 1985
  • Radiation damage in a single crystal of ammonium sulfate caused by ${\gamma}$-irradiation at room temperature has given rise to several paramagnetic centers. Electron spin resonance (ESR) spectra of crystal are obtained with the X-band EPR spectrometer at room temperature. An intense and isotropic peak of Gaussian shape at g = 2.0036 is assigned to $SO_3^-$, which shows power saturation effects. Angular dependence of spectra is studied for the rotations about three mutually perpendicular axes a, b and c. The g-values are obtained from the relative distances between isotropic peak of $SO_3^-$ and anisotropic peak of the species. Principal $g^-$values and direction cosines were calculated by diagonalizing the 3${\times}$3 matrix whose elements are the $g^-$values for each species. From the analysis of characteristic principal $g^-$values and direction cosines for ammonium sulfate single crystal, anisotropic peaks corresponding to $SO_4^-,\;SO_2^-$ and defect structure corresponding to electron excess type are identified.

  • PDF

A Study on Properties of Conductive Pattern by the Rheology Characteristics of Ag Pastes for Gravure Printing (그라비어 인쇄용 Ag Paste의 레오로지 특성에 따른 전도성 패턴의 물성 연구)

  • Lee, Dong-Wook;Cho, Mi-Jeong;Lee, Mi-Young;Nam, Su-Yong;Lee, Taik-Min
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.26 no.1
    • /
    • pp.39-50
    • /
    • 2008
  • We have manufactured Ag pastes for gravure printing by adding different solvent contents. Then the gravure printability and properties of conductive patterns gravure-printed by the different rheology characteristics of pastes were investigated. The dispersity of pastes was increased and the viscosity and shear rate dependence of viscosity for pastes were decreased by increasing the solvent content. Also storage modulus G', loss modulus G" and angular frequency value when G" starts to be bigger than G' of pastes were increased by decreasing the solvent content. These mean a flow drop of paste. As a result of gravure printing using two plates which have different line counts(175line and 350line), conductive patterns printed using 175line were spreaded more but Ag packing, thickness and conductivity of the conductive patterns were better than those printed using 350line. And the spread values of conductive patterns were increased with solvent contents but the best properties for Ag packing, surface roughness and conductivity of the conductive pattern were obtained by paste (3) which has 550cps of viscosity at $100s^{-1}$ and tan ${\delta}$ > 1 at 10rad/s. As a result of gravure printing using 350 line plate and paste (3), the conductive pattern has $1.2{\mu}m$ of film thickness and $1.9{\times}10^{-5}{\Omega}{\cdot}cm$ of conductivity.

  • PDF

Development of Electronic Personal Dosimeter with Hybrid Preamplifier using Semiconductor Detector (반도체 검출기를 이용한 Hybrid 전치증폭기형 전자식 개인선량계 개발)

  • Lee, B.J.;Kim, B.H.;Chang, S.Y.;Kim, J.S.;Rho, S.R.
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.51-57
    • /
    • 2002
  • An electronic personal dosimeter(EPD) with hybrid type preamplifier adopting a semiconductor detector as a radiation detector has been developed, manufactured and test-evaluated. The radiation detection characteristics of this EPD has been performance-tested by using a reference photon radiation field. After several test-irradiations to a $^{137}Cs$ gamma radiation source the radiation detection sensitivity of this EPD appeared to be $3.8\;cps/Gy{\cdot}h^{-1}$. The linearity of radiation response was kept within 8% of the dose equivalent ranges of $10{\mu}Sv{\sim}4Sv$ and the angular dependence was under less than 4% in angles of ${\pm}60^{\circ}$. It was confirmed that the energy response range was in $60{\sim}1,250keV$ given in the ISO standard. This EPD satisfied the international criteria for the EPD in the mechanical and the environmental performance test for 9 test categories according to IEC 61526.