• Title/Summary/Keyword: angled

Search Result 298, Processing Time 0.023 seconds

Curved Screen Display Immersion Simulation System for Landscape Evaluation (경관평가를 위한 곡면스크린 방식의 몰입형 시뮬레이션 시스템)

  • Chang, Jong-Hyun;Kim, Choong-Sik;Lee, In-Sung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.61-68
    • /
    • 2009
  • The objective of this study was to examine the possibility of utilizing the immersion stereoscopic image with a curved-screen-display as a tool for evaluating the landscape. The curved-screen-display ensures the continuity of the image and can be simultaneously evaluated by many people. Fifty-meter-wide Gangnamdaero Boulevard in Seoul was selected for this study, and the simulation was done using computer graphics. With the computer simulation, a questionnaire on landscape preferences was conducted according to different visual environments (immersion, non-immersion) and different projection types(stereoscopic or plane image). In the results of this study, the landscape preference was largely dependent on the immersion environment. Using the immersion-type simulation, the observer can easily evaluate the preference with higher judgment power. The stereoscope or plane projection type does not have any significant result in terms of its judgment power. This result implies that it is very important to strengthen the sense of immersion by expanding the screen into an angled view in which the observer can become immersed while making and projecting the simulation to evaluate the landscape. As a landscape evaluation tool for examining the efficiency and usefulness of immersion simulation, this study has limitations in that it controls many factors in street landscape that adversely affect judgment. Accordingly, a detailed comparison and verification of the stereoscopic image in various environments, including street width and building height ratio, must be conducted.

A Study on the Cloth Design for Elderly Women to Mask Their Dorsal Curvature (노년기여성의 배면만곡도 감소효과를 위한 의복디자인 연구)

  • Kim Tae-Kyung;Lee Kyoung-Hi;Park Jung-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.14 no.3 s.35
    • /
    • pp.183-195
    • /
    • 1990
  • The author has studied the effect of clothes design to mask the dorsal curvature that is one of the commonest changes in elderly women. Body measurements including the body type and the status of dorsal curvature were perfor-med on 153 women of over 60 years of age, and then a body form to fit to the mean measure-ments was made to evaluate the effects of various designs to it. With 31 pattern designs modified by changing in their slash lines and gathers using darts, the diminishing effect of the rounded back were evaluated by means of sensory test. The results of this study can be summarized as follows: I . Results from the body measurements 1) The mean body type in elderly women was that of obesity. 2) With the advancement of age, the angle to indicate the degree of dorsal curvature as well as the angle to indicate the posture are increased. II . Concerning to the clothes design to diminish the shape of dorsal curvature 1) Among the designs by the position of darts, the basic pattern (Fig. 5-1-(1)) showed the best effect to mask the shape of dorsal curvature. 2) Out of the applied designs of princess lines, that in which the slash line is pointing toward the shoulder point (Fig. 5-2-(1)) seemed to be most effective. 3) What has angled princess line (Fig. 5-3-(1)) had the most diminishing effect among the waist darts and armhole princess lines. 4) Among the V-shaped designs, the slashed at the shoulder point (Fig. 5-4-(1)) had the best effect to lessen the shape of the dorsal cuuature. 5) Wider angle yoke had better effect to the narrow angle one among the designs with straight yoke, and that with downward direction (Fig. 5-5-(1)) showed the best effect. 6) Between straight wide angle yoke and curved yoke, that of curved one with downward direction (Fig. 5-6-(1)) had better effect as far as the masking effect of dorsal curvature is concerned. 7) Gathers around the neck showed better effect to those around the shoulder, and the more amount of gathers (Fig. 5-7-(1)), there was better effect. 8) The design with midline gathers at the level of horizontal slash line of armhole (Fig. 5-8-(1)) showed better effect to that with seperated gathers. 9) In case of design with gathers at the horizontal line of armhole, it showed the better effect with less amount of gathers in midline ones, but with more amount in the side ones. 10) Considering all 7 different designs with better effect in covering the shape of dorsal curvature, it was evident that the design with gathers was far better than the design with application of slash lines.

  • PDF

The Evaluation of Usefulness of the Manufactured DTAB (Double Tilt Angle Board) System (Double Tilt Angle Board (DTAB)의 자체 제작에 관한 유용성 평가)

  • Lee, Joung-Jin;Jang, In-Gi;Kim, Wan-Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.43-51
    • /
    • 2006
  • Purpose: To resolution of A hospital-handmade modification double tilt angle immobilization system (DTAB immobilization system) and to report the clinical results of it. Material and Methods: It was developed in conjunction with the breast board for patients unable to achieve and maintain the desired uncomfortable respiration and position of set-up needed in the treatment of RT (This custom design provides an alternative to accomplishing this desired head angle needed to relax position treatment area, realizing that the lenses totally protected eye-ball out) By using the angled breast board and SBDD(small bowel device), reproducibility of set-up and patient comfort were addressed throughout the simulation, computed tomography planning and treatment process. Results: Usually patients the error range-within 5 mm. When use of Aqua patients error range-within 3 mm. Conclusion: It was constructed in tandem with a unique custom-built double tilt angle board (DTAB). It was designed to eliminate clinical set-up problems with head immobilization and instability during treatment, thus providing for a more comfortable head rest for the patient.

  • PDF

Reconstruction of the Orbital Floor Fracture using the Antral Balloon Catheter with Radiopaque Dye (안저골절 정복술 후 풍선 달린 카테터와 방사선조영제의 이용)

  • Choi, Hwan-Jun;Lee, Han-Jung;Yang, Hyung-Eun;Lee, Young-Man
    • Archives of Plastic Surgery
    • /
    • v.37 no.1
    • /
    • pp.99-103
    • /
    • 2010
  • Purpose: Blow-out fractures are reduced through transcutaneous or transconjunctival incisions. But the field of orbital surgery is difficult due to lack of visualization of fracture site, blind dissection of orbital floor, susceptibility of injury of orbital structures. In these situations, the former technique of using an antral balloon catheter has advantages over other methods for reconstruction because of its rapidity, simplicity, and inexpensiveness. Furthermore, the antral balloon catheter allows not only elevation of the orbital bone fragment but also expansion of the maxillary sinus in cases where there is a fracture of its walls. But postoperative follow-up method using computed tomography is expensive. Hence, we report a simple and inexpensive follow-up method using radiopaque dye inflation. Methods: We performed endoscopic transantral approach in 5 cases of blow-out fracture under general anesthesia. To accomplish this technique, a rigid 4 mm, 0 or 30 degree angled endoscopy was inserted into the maxillary sinus. Inflation of the catheter started gradually, with 10 to 15 mL of saline mixed radiopaque dye (saline: dye, 5 : 1) by syringe and while observing the elevation of the fracture site with endoscope until a proper contour was reached. For the maintain of the position of fractured site, 12 French urinary balloon foley catheter were used in fracture site for 7 - 10 days. Results: Postoperative assessment was performed by means of clinical and simple radiographic examination to secure the catheter under the inferior orbital wall and in the maxillary sinus. No specific complications occurred related to this procedure. Results of the surgery and follow-up in all cases were satisfactory. Conclusion: It may be a better alternative to the conventional follow-up method, with less cost and effectiveness of the catheter patency. The advantages of using the urinary balloon foley catheter with the radiopaque dye include the following : it is safe, efficacy, simple, and especially low cost. On drawback of this method is the discomfort to the patient caused by the catheter during the treatment.

Introduction of Hindfoot Coronal Alignment View (후족부 관상면 배열 영상에 대한 고안)

  • Moon, Il-Bong;Jeon, Ju-Seob;Yoon, Kang-Cheol;Choi, Nam-Kil;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.225-228
    • /
    • 2006
  • Purpose: Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hindfoot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hindfoot coronal alignment view. Material : 1) Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. 2) Both feet stood on a radiolucent platform with equal weight on both feet. 3) Both feet are located foot axis longitudinal perpendicular to the platform. 4) Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. 5) The x-ray beam is angled down approximately $15^{\circ} to $20^{\circ} Result : 1) This image described tibial axis and medial, lateral tuberosity of calcaneus. 2) Calcaneus do not rotated. 3) The view is showed by talotibial joint space. Conclusion: Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hindfoot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hindfoot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hindfoot and varus, valgus deformity of calcaneus.

  • PDF

Effect of Drift Pin Arrangement for Strength Property of Glulam Connections (드리프트 핀의 배열 형태가 집성재 접합부의 회전 거동 및 강도 성능에 미치는 영향)

  • Lee, In-Chan;Park, Chun-Young;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.10-21
    • /
    • 2007
  • It is necessary to study about moment performance of glulam-dowel connections which had been applied rotation. To analyze and predict the moment performance, angled to grain load was replaced with parallel to grain load and perpendicular to grain load. The dowel bending strength and dowel bearing strength were tested. And tensile strength test for connections of two different end distances was performed. Specimens of rotation test were composed with different drift pin numbers and drift pin arrangement. Connection deformation was occurred by plastic behavior of drift pin after yield when tensile load applied at connection. And the absorbing drift pin deflection by end distance continued the connection deformation. When rotation applied at connection that 2 drift pins were arranged parallel to grain (b2h), it showed similar performance with tensile perpendicular to grain. And connection that 2 drift pins were arranged perpendicular to grain (b2v) showed similar performance with tensile parallel to grain. Connection capacity that 4 drift pins were arranged rectangular (b4) showed 1.7 times as strong as connection that 2 drift pins were arranged parallel to grain (b2h). These results agreed predicted values and it is available that rotation replaced with tensile load.

Characteristics of Pearlescent Pigment using in Make-up Cosmetics (색조화장에 사용되는 진주광택 안료의 특성)

  • Kwak, Han-Ah;Choi, Eun-Young;Chang, Byung-Soo
    • Applied Microscopy
    • /
    • v.39 no.1
    • /
    • pp.41-48
    • /
    • 2009
  • We investigated the morphological characteristics of the pearlescent pigment by using scanning electron microscope, energy dispersive X-ray spectrometry and thermal analyzer. The result is that the shape of pigment is platy polygonal form through observing the pearlescent pigment by the scanning electron microscope. The size of pigment is various and not formed in standardized size or shape. The pigment flakes were measured about from $30{\mu}m$ to $300{\mu}m$. The tip of the piece of pigment is pointed shape or angled. The result of observing them by the scanning electron microscope in magnifying high power is that the edge and the lateral face of them is an round form and the measurement of thickness is about $9{\mu}m$. As well using the high magnification scanning electron microscope, the surface of the pigment flake observed like rugged as coating with the $TiO_2$ element, the diameter of the coating particle is around 60 nm, then the coating particle consists of granular substance. Analysis of the configuration elements of pearlescent pigment using by the energy dispersive X-ray spectrometry is that O, Si, C, Na, Ca, Ti, Zn detected in the surface of pigment and its lateral face identifies similar components. In thermal analysis, there are no contained quantity differences between them in beginning from $100^{\circ}C$ to $800^{\circ}C$ showing thermal analysis, 1.1% out of contained quantity reduced at $115^{\circ}C$, 1.7% dropped at $416^{\circ}C$, and 1.9% decreased at $797^{\circ}C$.

The Effect of Tomographic Angles on the Osteophytic Lesion Detectability of the Mandibular Condyle (단층촬영 각도의 변화가 하악과두의 골 증식성 병소의 인식에 미치는 영향)

  • Han Sang-Sun;Kim Kee-Deog
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.309-325
    • /
    • 1999
  • Purpose: To find out the effects that different tomographic angles have on the osteophytic lesion detectability of condyle head by comparison the individualized lateral tomographic image with the various tomographic angled images using SCANORA/sup (R)/. Materials & Methods: This study is performed to simulate osteophytic lesions by a series of dentin chips placed at six locations on condyle head. The control angle is 15° and from this angle. tomographic angle were varied with -10°, +10°, +20°. All the images with each sized dentin chip were scored by three dental radiologists with the use of confidence levels for presence or absence of the lesion, each examiner viewed one of the images twice. A rating scale from 0 to 2 (0, lesion definitely not present; 1. uncertain if lesion is present; 2, lesion definitely present). Responses were assessed by Tukey' s multiple comparison method and kappa value. Results: 1. The lesion size of 0.3 mm could not be detected in all the tomographic angles. As the size of the lesion increased the average value of lesion detectability also increased. 2. In the lesion sizes of 0.7 mm there was statistically significant difference between the 15° control angle and the altered tomographic angles (p<0.05). In 1.0 mm lesion there was no significant difference in the ±10° altered angles (p >0.05). but there was significant difference in the altered angle (p<0.05). In the lesion sizes of 0.3 mm and 2.0 mm there was no significant difference between the 15° control angle and all the altered angles (p >0.05). 3. In the anteromedial. anterosuperior, anterolateral area there was no significant difference between the 15° control angle and the ±10° altered angle (p >0.05), but in the comparison with the +20° altered angle there was significant difference (p<0.05). Conclusion: When imaging the lateral tomography of the temporomandibular joint used by SCANORA/sup (R)/, it can be considered that in the osteophytic lesion size of 2 mm and above, the tomographic angle difference within +20° to the horizontal angle of the condyle. has little effect on the lesion detectability. And in the lesion size of 1 mm, the altered angle within ±10° also has little effect on the lesion detectability.

  • PDF

Evaluation of Scatter Reduction Effect of the Aft-Multiple-Slit (AMS) System Using MC Simulation (MC 시뮬레이션을 이용한 Aft-Multiple-Silt 시스템의 산란선 제거 효과 평가)

  • Chang, Jin-A;Suh, Tae-Suk;Jang, Doh-Yun;Jang, Hong-Seok;Kim, Si-Yong
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.224-230
    • /
    • 2010
  • Purpose: We designed the aft-multiple-slit (AMS) system to reduce scatter in cone-beam computed tomography (CBCT). As a preliminary study, we performed a Monte Carlo N-Particle Transport Code (MCNP) simulation to verify the effectiveness of this system. Materials and Methods: The MCNPX code was used to build the AMS geometry. An AMS is an equi-angled arc to consider beam divergence. The scatter-reduced projection images were compared with the primary images only and the primary plus scatter radiation images with and without AMS to evaluate the effectiveness of scatter reduction. To obtain the full 2 dimensional (2D) projection image, the whole AMS system was moved to obtain closed septa of the AMS after the first image acquisition. Results: The primary radiation with and without AMS is identical to all the slit widths, but the profiles of the primary plus scattered radiation varied according to the slit widths in the 2D projection image. The average scatter reduction factors were 29%, 15%, 9%, and 8% when the slit widths were 5 mm, 10 mm, 15 mm, and 20 mm, respectively. Conclusion: We have evaluated the scatter reduction effect of the AMS in CBCT imaging using the Monte Carlo (MC) simulations. A preliminary study based on the MCNP simulations showed a mount of scatter reduction with the proposed system.

Right Thoracotomy for Reoperation of Mitral Valve (우측 개흉을 통한 승모판 재수술)

  • 조창욱;구본일
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1342-1346
    • /
    • 1996
  • A right thoracotomy was used for the reoperation or mitral valve of 15 patients who had previously undergone a cardiac operation through a median sternotomy. In our experience. this approach provided dn excellent exposure of the nlitral valve and easy cannulations of both cavie with minimal dissection, ilvoiding any damage of cardiac and major vessels during re-sternotomy Arterial cannulation was performed in the ascending aorta in 13 patients And in the femoral artery in 2 patients. In earlier cases, venous cannulation was done in the SVC And IVC through the right atrium and snared. In later cases, this could be done without snaginly of both cavae or by placing a silgle light-angled catheter into the right atrium. Crystalloid cardioplegic solution was infused for myocardial protection. Hypothermia was controlled at 20\ulcorner$25^{\circ}C$. For defibrillation, internal paddles were used In one patient while sterilized external paddles were used in 10 patients. In the remaining four patients. however. the heart beat spontaneously The respirator could be weaned within 48 hours alter the operation and no pulmonary complication was observed. One out of the 15 patients expired due to sudden attack of ventricular tarchycardid developed ten days after the operation, but the rest of the patients were discharged with good condition.

  • PDF