주택 주방후드의 소음특성에 관한 연구 (A Study on the Noise Characteristics of House Range Hoods)

  • 김진기;손장열;조창근;신일섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.355-358
    • /
    • 2005
  • This study aims at comparing the noise characteristics of conventional and functional hood. Measurement and analysis was carried out in anechoic room and actual environment. In case of anechoic room, intensity and sound pressure level were measured. In case of actual environment sound pressure level under different apartment size and distances. Sound pressure level of actual environment was higher than that of anechoic room. It is concluded that noise characteristics were different from each other in case of anechoic room and actual environment.

  • PDF

대우건설기술연구소 음향실험동의 성능 평가 (Evaluation on Acoustic Performance of the DICT's Acoustic Loboratory)

  • 정갑철;이주원;윤창연;박칠림
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.735-740
    • /
    • 1998
  • Acoustic performance of DICT's acoustic laboratory was evaluated. As a result, background noise and inverse squre law of an anechoic room were satisfied with ISO 3745 standard value. Also, reverberation time and standard deviation of sound pressure level distribution in reverberation rooms were within maximum error limit that was ruled on ISO 3741.

  • PDF

무향팬테스터를 이용한 냉장고용 팬 성능/소음 측정 (Measuring performance and SPL of refrigerator fan using anechoic fan tester)

  • 정정교;이준화;주재만;강정훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.253-256
    • /
    • 2004
  • Acoustical noise at low frequency range (below 500Hz) of refrigerator result from fans which are inside of the refrigerator. In generally to evaluate and apply to refrigerator it is recommended that acoustical noise and fluidic performance of the fan were measured simultaneously. To do that twin-room type anechoic wind tunnel was needed. But constructing twin room type anechoic wind tunnel was very expensive and estimation of small refrigerator fan performance was not easy. So in this paper we composed anechoic fan tester. A successful noise and performance measurement was performed using the anechoic fan tester. Existing 22 kinds of refrigerator fan were investigated and mapped into one database. Refrigerator duct pressure resistance were measured and reflected into the fan database to find out appropriate fan. Through the application of fan database, the refrigerator became less noise compared to current one and these data shows what is the best way to reduce fan noise.

  • PDF

소리의 지향성 측정을 위한 전기음향실험기기의 자동화 (Automation of electrical acoustic experimental apparatus for the directivity measurement of sound)

  • 장순석;고재하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.574-576
    • /
    • 2004
  • The directivity of the sound pressure increases the sensitivity of the incoming sound from specific directions. The directivity measurement of the sound pressure is usually done in an anechoic room using a sloping motor. In this paper a replaceable anechoic chamber was designed for the acoustic directivity pattern measurement. Electrical equipments were interfaced with a PC for experiment automatic control. Some comparative results are shown in the result.

  • PDF

소리의 방향성 측정을 위한 실험기기의 자동제어 (Automatic control of experimental apparatus for sound's directivity measurement direction acoustic wave)

  • 장순석;고재하;이제형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.591-594
    • /
    • 2004
  • The directivity of the sound pressure increases the sensitivity of the incoming sound from specific directions. The directivity measurement of the sound pressure is usually done in an anechoic room using a steping motor. In this paper a replaceable anechoic chamber was designed for the acoustic directivity pattern measurement. Electrical equipments were interfaced with a PC for experiment automatic control. Some comparative results are shown in the result.

  • PDF

실험실에서의 발코니창호 차음성능 평가 (The estimation of Sound insulation performance by the balcony windows in the reverberant room and anechoic room)

  • 김태희;신일섭;조창근;오진균;김남욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.956-959
    • /
    • 2007
  • The extension of a road system result from construction of the builling near the noise source as the roads, railroads. Many people who have a living space near the road are damaged by the noise generated the road system. Therefore, the damage will be reduced by the appropriate measure like putting some distance between receiver and source. The windows are weak among the building materials. But mainly we uses the windows as building exterior materials. So the sound insulation of the balcony windows was measured and compared.

  • PDF

주거 공간내 냉장고 소음의 정상상태 평가 (Evaluation of indoor refrigerator noise in steady-state condition)

  • 이충화;정정호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.790-795
    • /
    • 2004
  • The characteristics of refrigerator noise recorded in anechoic chamber was investigated in condition of a the real living room and a kitchen. To predict the noise propagation in an apartment unit, room acoustic simulation software was used. It was found that the noise level in the real living room was $4\sim8dB$ higher than in the anechoic chamber. When a noise barrier and absorption materials were used on the rear wall and floor, the noise level reduced up to $3\sim4dB$. In addition, when the subjective evaluation of auralized refrigerator noise was undertaken using headphone, it was revealed that 21dB (A) is the allowable sound pressure level of 95% satisfaction.

  • PDF

Design and Analysis of Experimental Anechoic Chamber for Localization

  • Kim, Keon-Wook
    • 한국음향학회지
    • /
    • 제31권4호
    • /
    • pp.225-234
    • /
    • 2012
  • The anechoic chamber is essential tool to measure the various acoustic parameters with high precision. The chamber provides the climate controlled indoor environments but requires the dedicated room at a great cost in order to isolate and absorb sound field. Provided the purpose of the chamber is specific to the experiments of sound localization, the performance requirements excluding free field can be alleviated for cost effective solution. This paper designs low cost and profile anechoic chamber based on acoustic pyramids and evaluates the performance specified by the Annex of ISO 3745. Data analysis is employed to measure the free and hemi-free field performance over five straight paths for working areas and four paths for non-working areas. The identical two measurement campaigns were conducted for free and hemi-free field chamber which is easily interchangeable by simple labor in this chamber design. In the working area with conventional speaker, the results of these analyses demonstrate that lab-designed anechoic chamber is in conformance with ISO 3745 for 250 Hz - 16 kHz one-third octave band at free field chamber and for 1 kHz - 16 kHz one-third octave band at hemi-free field chamber.

대시 패널의 투과손실 측정 및 예측 (The Measurement and Prediction of Transmission loss through Dash Panel)

  • 김정수;강연준
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 추계학술발표대회논문집 제23권 2호
    • /
    • pp.191-194
    • /
    • 2004
  • This study Is an measurement and prediction of transmission loss through dash panel with multi-path in a vehicle. Measurement results of transmission loss are decided by sound power measured using the sound intensity method under locating a sound source in the anechoic room and reverberant room, respectively. Prediction one is decided by multi-path analysis of dash panel composed by a various part of materials and complicated shape. Finally, two results show a great agreement between measured and predicted transmission loss.

  • PDF

무향실에 있어서의 음압레벨과 거리정위와의 관계 (Relation between sound pressure level and auditory distance perception in anechoic room)

  • 김해영
    • 한국산학기술학회논문지
    • /
    • 제10권6호
    • /
    • pp.1201-1206
    • /
    • 2009
  • 음상의 거리정위에 있어서 중요한 물리적 요인으로는 알려진 음압레벨, 반사음, 양 귀간 차, 음원의 종류, 머리전달함수(HRTF) 등의 여러 요인들이 중요한 판단 자료로 이용되어진다고 알려져 있다. 본 논문에서는 거리판단에 사용되어지는 물리적 요인 중 음압레벨의 크기가 거리정위에 미치는 영향을 알아보기 위해 반사음이 존재하지 않은 무향실에서 음원의 출력 음압레벨을 일정한 경우와 귀 입력 음압레벨을 일정하게 한 경우에 대하여 청취실험을 통해 거리판단에 있어서 음압레벨의 영향에 대하여 고찰했다. 그 결과. 음원출력 음압레벨을 일정하게 한 경우와 귀 입력 음압레벨을 일정하게 한 청취실험에 있어서 제시한 음원거리보다 지각한 음상거리를 가깝게 정위하는 경향이 있다는 것이 관찰되었다. 또, 귀 입력 음압레벨이 일정한 경우에는 약 2m 정도까지의 거리에서는 실제 제시한 음원거리의 증가에 따라 지각한 음상의 거리가 음원거리에 대응하여 증가하지만, 그 이상의 거리에서는 음원거리의 증가에 따라 지각한 음상거리가 증가가 거의 없음을 알 수 있었다. 반면 음원출력 음압레벨이 일정한 경우에는 지각한 음상거리가 귀 입력 음압레벨이 일정한 경우보다 보다 더 먼 3m 정도의 거리까지 증가하고 있음을 알 수 있었다. 이와 같은 청취실험 결과로부터 반사음이 존재하지 않은 조건에서의 음상의 거리정위에는 음압레벨이 거리판단의 중요한 요소로 작용하고 있음이 확인되었다.