• Title/Summary/Keyword: and plasma display panel

Search Result 632, Processing Time 0.078 seconds

23' LCD TV by using ALT plasma beam alignment technology

  • Lee, C.Y.;Tang, H.C.;Chen, C.W.;Shih, Y.J.;Liu, C.H.;Lin, C.H.;Yang, K.H.;Lin, S.H.;Chang, H.C.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.776-779
    • /
    • 2006
  • The alignment of liquid crystal (LC) is one of the key issues of liquid crystal display (LCD) technologies. In this study, we aligned polyimide (as the LC alignment layer) by ALT plasma beam and to realize the stability and characteristics of this technology. The characteristics such as anchoring energy, pre-tilt angle, voltage holding ratio(VHR) and residual direct current(Rdc) were discussed. Besides, we applied it to the in plane switch (IPS) mode 23" WXGA real panel, the performance parameters and electrical properties were measured and compared with those of rubbing alignment. From the result, we demonstrated a successful LC alignment treatment process in real panel by ALT plasma beam.

  • PDF

Study on Noise Reduction of Plasma Display Panel (플라즈마 디스플레이의 소음 저감 연구)

  • Park, Dae-Kyong;Kweon, Hae-Sub;Jang, Dong-Seob
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.693-698
    • /
    • 2002
  • For the evaluation of the plasma display panel (PDP)'s noise, vibration and sound characteristics of fanless PDP are measured and investigated. PDP is a type of two-electrode vacuum tube which operates on the same principle as a household fluorescent light. An inert gas such as argon or neon is injected between two glass plates on which transparent electrodes have been formed, and the glass is illuminated by generating discharge. For this discharge, both high voltage and currents are needed and cause an acoustic noise. We investigated the noise characteristics connected with both a electromagnetic elements from SMPS to panel through X, Y and logic board, and a mechanical elements form panel to case through transfer path which related with vibration and heat. To reduce the noise of PDP, a discharge pulse memory design related with both higher brightness and lower power consumption is important and mechanical characteristics connected with dissipation process of both heat and vibration generated by panel discharge must be investigated.

  • PDF

Influence of wall charge configurations prior to addressing discharge on dynamic margin in AC Plasma Display Panel

  • Jung, Y.;Choi, J.H.;Jung, K.B.;Kim, S.B.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.764-767
    • /
    • 2003
  • We have experimentally investigated the influence of wall charge configurations prior to addressing discharge on dynamic margin in AC plasma display panel. In this experiment, we have analyzed the quantity and polarity of wall charge accumulated on the front and rear dielectrics just prior to the addressing discharge under the conventional driving sequence.

  • PDF

Thermal Properties of Phosphate Glass with Additives for Barrier-Ribs in Plasma Display Panel

  • Lee, Chung-Yong;Kim, Dong-Sun;You, Young-Jin;Lee, Sang-Ho;Hwang, Seong-Jin;Kim, Hyung-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.823-826
    • /
    • 2008
  • Phosphate glass added the various alkali additives is one of the substitutive materials for the barrier-ribs in plasma display panel. The results of differential thermal analysis and coefficient of thermal expansion show that the alkali oxides affect the thermal properties of phosphate glass.

  • PDF

AC Plasma Display Panel with Irregular Micro-scale Holes in the Front Dielectric Layer

  • Cho, Kwan-Hyun;Ahn, Sung-Il;Kim, Woo-Hyun;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.711-712
    • /
    • 2009
  • The fabrication of micro-scale irregular holes by using PMMA (Poly Methyl Methacrylate) beads in the front dielectric layer was proposed to improve luminous efficacy of an ac plasma display panel. Through the firing process of front dielectric layer, bowl shaped holes with a depth of $2.5{\mu}m$, a top diameter of $8-12{\mu}m$, and a bottom diameter of $4-7{\mu}m$ were fabricated. The proposed ac plasma display panel with the irregular micro-scale holes improved the luminous efficacy by 18 % due to the decrease in the minimum sustain voltage.

  • PDF

A Study of Optical Properties of Assembled Plasma Display Panel with 3-D Optical Code

  • Park, Hyun-Myung;Kang, Jungwon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.1
    • /
    • pp.67-71
    • /
    • 2012
  • The optical properties of PDP, such as the transmittance and reflectance, were analyzed with 3D optical code. Three different ITO-less structures in the front panel are examined. In the assembled panel study, the test 1 structure shows 16.6% and 10.2% higher reflectance than the structures of tests 2 and 3, respectively. In order to check the validation of the simulation result, three 7.5-inch test panels having the same geometry and property are fabricated as simulation models. The calculated reflective properties are compared to the measured data from real panels. The relative difference extracted from the simulation and measurement methods is less than 4.9% and are well matched.

A Study on the 0-Dimensional Simulation of He+Ne+Xe Gas and the Discharge Characteristics in Plasma Display Panel (플라즈마 디스플레이 패널용 He+Ne+Xe 혼합가스에서 소량 Xe 함유에 대한 영 차원 수치해석과 방전특성연구)

  • Jeong, Hae-Yeong;Choe, Hun-Yeong;Kim, Geun-Su;Kim, Seong-Ik;Song, Bong-Sik;Park, Heon-Geon;Lee, Seok-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.9
    • /
    • pp.436-442
    • /
    • 2002
  • Recently color AC PDP(plasma display panel) technology is rapidly improved. However, the luminous efficiency improvement is a key issue for making plasma display into a large-area flat display. In this paper, we suggest a new concentration of Xe in He-Ne-Xe gas mixture in order to achieve a high luminous efficiency of color AC PDPs. We calculated the densities of 25 species as a function of the time zero dimensional simulation using CVODE solver and we compared the results of zero dimensional simulation with a measurement of photo wave brightness and luminous efficiency, in order to find the optimum mixing condition of He-Ne-Xe gas in color plasma display panel. We obtained a high discharge speed under Xe mixing ratio of 1% by simulation and confirmed that through measuring photo wave.

The effect of the cell size on the discharge characteristics of a plasma display panel

  • Moon, Cheol-Hee
    • Journal of Information Display
    • /
    • v.12 no.1
    • /
    • pp.29-35
    • /
    • 2011
  • In this study, plasma display panels with three different cell volumes were prepared by changing the spaces between the vertical barrier ribs into two and three times the reference structure. The discharge gap and area of the segmented ITO electrode were the same for the three cases, and Ne.20%Xe gas was used. The luminance and luminance efficiency were measured using applied voltage variations. The time evolution and intensity distribution of the infrared, which are related to the vacuum ultraviolet, were observed via intensified, charged, coupled device, and the visible-light intensity profiles were observed using PR-900 to analyze the discharge phenomena in the discharge cell.

Discharge Characteristics of a Plasma Display using Vertical Auxiliary Electrodes

  • Moon, Cheol-Hee
    • Journal of Information Display
    • /
    • v.9 no.1
    • /
    • pp.20-25
    • /
    • 2008
  • In a conventional plasma display, the bus electrode was located on the ITO electrode at the outer part of each cell. We propose a new electrode configuration using vertical auxiliary electrodes which play a role of electrically connecting ITO and bus electrodes with the aim of enhancing discharge and luminous characteristics of the PDP (Plasma Display Panel). In this paper, luminance and luminous efficiency of the 3 in.-diagonal test panel are measured with various number of vertical auxiliary electrodes such as 2, 50 and 150. The change in the luminous characteristics is explained in connection with the discharge characteristics of the PDP cells such as current peak, IR emission peak and ICCD picture image.

A Sub-field Rearrangement Driving Method for Reducing Dynamic False Contour in Plasma Display Panels

  • Lee, Seung-Yong;Choi, Byong-Deok
    • Journal of Information Display
    • /
    • v.7 no.1
    • /
    • pp.30-34
    • /
    • 2006
  • A sub-field rearrangement driving method has been proposed to reduce a DFC (Dynamic False Contour) phenomenon in plasma display panels. The proposed driving method expresses 256 gray levels with 16 sub-fields, while conventional one uses only 8 sub-fields. Notwithstanding the increase in the number of sub-fields, the display time is similar to the conventional 8 sub-fields driving method by appropriate choosing selective writing and selective erasing for sub-fields.