• Title/Summary/Keyword: and channel instability

Search Result 114, Processing Time 0.027 seconds

고분자전해질형 연료전지의 유로 채널 모사를 통한 단일 액적의 불안정성 관찰 (Investigation on the Liquid Water Droplet Instability in a Simulated Flow Channel of PEMFC)

  • 김보경;김한상;민경덕
    • 한국자동차공학회논문집
    • /
    • 제16권2호
    • /
    • pp.93-98
    • /
    • 2008
  • To investigate the characteristics of water droplet on the gas diffusion layer from both top-view and side-view of the flow channel, a rig test apparatus was designed and fabricated with prism attached plate. This experimental device is used to simulate the growth of single liquid water droplet and its transport process with various air flow velocity and channel height. The contact angle hysteresis and height of water droplet are measured and analyzed. It is found that droplet tends towards to be instable by decreasing channel height, increasing flow velocity or making GDL more hydrophobic. Also, the simplified force balance model matches with experimental data only in a restricted range of operating conditions and shows discrepancy as the air flow velocity and channel height increases.

The Effect of Light on Amorphous Silicon Thin Film Transistors based on Photo-Sensor Applications

  • Ha, Tae-Jun;Park, Hyun-Sang;Kim, Sun-Jae;Lee, Soo-Yeon;Han, Min-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.953-956
    • /
    • 2009
  • We have investigated the effect of light on amorphous silicon thin film transistors based photo-sensor applications. We have analyzed the instability caused by electrical gate bias stresses under the light illumination and the effect of photo-induced quasi-annealing on the instability. Threshold voltage ($V_{TH}$) under the negative gate bias stress with light illumination was more decreased than that under the negative gate bias stress without light illumination even though $V_{TH}$ caused by the light-induced stress without negative gate bias was shifted positively. These results are because the increase of carrier density in a channel region caused by the light illumination has the enhanced effect on the instability caused by negative gate bias stress. The prolonged light illumination led to the recovery of shifted VTH caused by negative gate bias stress under the light illumination due to the recombination of trapped hole charges.

  • PDF

A Light-induced Threshold Voltage Instability Based on a Negative-U Center in a-IGZO TFTs with Different Oxygen Flow Rates

  • Kim, Jin-Seob;Kim, Yu-Mi;Jeong, Kwang-Seok;Yun, Ho-Jin;Yang, Seung-Dong;Kim, Seong-Hyeon;An, Jin-Un;Ko, Young-Uk;Lee, Ga-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권6호
    • /
    • pp.315-319
    • /
    • 2014
  • In this paper, we investigate visible light stress instability in radio frequency (RF) sputtered a-IGZO thin film transistors (TFTs). The oxygen flow rate differs during deposition to control the concentration of oxygen vacancies, which is confirmed via RT PL. A negative shift is observed in the threshold voltage ($V_{TH}$) under illumination with/without the gate bias, and the amount of shift in $V_{TH}$ is proportional to the concentration of oxygen vacancies. This can be explained to be consistent with the ionization oxygen vacancy model where the instability in $V_{TH}$ under illumination is caused by the increase in the channel conductivity by electrons that are photo-generated from oxygen vacancies, and it is maintained after the illumination is removed due to the negative-U center properties.

개수로에서의 상류-사류 천이영역에 대한 부정류 해석 (Unsteady Flow Analysis through the Subcritical-Supercritical Transition Region)

  • 한건연;박재홍;이종태
    • 물과 미래
    • /
    • 제27권2호
    • /
    • pp.85-96
    • /
    • 1994
  • 자연하천의 부정류에 Preissmann 기법을 적용시 나타나는 수치 불안정성의 원인을 규명하고 불안정성을 극복하기 위한 적절한 대책을 제시하였다. 주된 불안정성의 원인으로는 천이류, 하도단면의 급격한 변화, 부적절한 조도계수, 계산시간 및 거리간격, 급격하게 증가하는 유입수문곡선, 그리고 마른 하상 등이다. 이런 불안정성의 주된 원인은 천이류의 발생과 관계가 있으며 상류-사류가 공존하는 자연 하도에서 천이류를 해석할 수 있는 모형을 제안하였다. 가상하도를 통하여 모의 수치실험을 수행한 결과 전하도구간에 대하여 안정성있게 수렴하고 있었으며, 일관성있는 유량, 수위자료를 얻을 수 있었다. 본 연구의 모형은 앞으로 실제 하천자료를 통해 적용성의 검증이 이루어진다면 천이류로 발생하는 수치계산의 어려움의 해결에 기여할 수 있다고 판단된다.

  • PDF

Y형 마이크로채널에서의 물/기름 2상 유동에 대한 Micro-PIV 측정 (Micro-PIV Measurement of Water/Oil Two Phase Flow in a Y-Junction Microchannel)

  • 윤상열;고춘식;김경천
    • 대한기계학회논문집B
    • /
    • 제28권6호
    • /
    • pp.682-687
    • /
    • 2004
  • Y-junction microchannels are widely used as a flew mixer. Fluids are entered from two branch channels and merged together at a combined channel. In this study, we suggest a simple method to create the fluid digitization using flow instability phenomena. Two immiscible liquids (water/oil) are infused continuously to each Y-junction inlets. Because of the differences in fluid and flow properties at the interface, oil droplet is formed automatically followed by flow instability. In order to clarify the hydrodynamic aspects involved in oil droplet formation, a quantitative flow visualization study has performed. Highly resolved velocity vector fields are obtained by a micro-PIV technique, so that detail flow structures around the droplet are illustrated. In this study, fluorescent particles were mixed with water only for visualization of oil droplet and velocity field measurement in water flow.

VSB-Based Digital On-Channel Repeater with Interference Cancellation System

  • Lee, Jae-Kwon;Suh, Young-Woo;Choi, Jin-Yong;Seo, Jong-Soo
    • ETRI Journal
    • /
    • 제33권5호
    • /
    • pp.670-678
    • /
    • 2011
  • This paper investigates the design and performance of a digital on-channel repeater (DOCR) for use in Advanced Television Systems Committee (ATSC) digital television (DTV) broadcasting. The main drawback of a DOCR is the echo interference caused by coupling between transmitter and receiver antennas, which induces system instability and performance degradation. In order to overcome this problem, an echo canceller based on the adaptive echo channel estimation (ECE) technique has been researched and applied for a DOCR. However, in the case of ATSC, the pilot signal, which is used for carrier synchronization, may cause a DC offset error and reduce the isolation performance of the echo canceller for a DOCR in an ATSC network. Moreover, since the multipath fading effect of a radio channel usually occurs in a real environment, it should be minimized to improve the overall performance of a DOCR. Therefore, due to the limited isolation performance of echo canceller and the multipath fading effect, an interference cancellation system (ICS) is proposed for a DOCR in an ATSC network. The performance of the proposed DOCR with an ICS is evaluated by software simulation and hardware test results.

박막의 두께가 비정질 InGaZnO 무접합 트랜지스터의 소자 불안정성에 미치는 영향 (Effects of thin-film thickness on device instability of amorphous InGaZnO junctionless transistors)

  • 전종석;조성호;최혜지;박종태
    • 한국정보통신학회논문지
    • /
    • 제21권9호
    • /
    • pp.1627-1634
    • /
    • 2017
  • 비정질 InGaZnO 박막 두께가 다른 무접합 트랜지스터를 제작하고 두께에 따른 양과 음의 게이트 스트레스 전압 및 빛을 비춘 상태에서 소자 불안정성을 분석하였다. 채널 박막 두께가 얇을수록 게이트 스트레스 및 빛이 인가된 상태에서 문턱전압 및 드레인 전류 변화가 큰 것을 알 수 있었다. 그 원인을 stretched-exponential 모델과 소자 시뮬레이션을 수행하여 설명하였다. 박막이 얇을수록 캐리어 트랩핑 시간이 짧기 때문에 전자나 홀이 빨리 활성화되는 것과 채널 박막의 뒷부분에서 채널의 수직 전계가 증가하여 전자나 홀을 많이 축적할 수 있는 것으로 설명하였다. IGZO 무접합 트랜지스터 제작에서 채널 박막의 두께를 결정할 때 채널 박막 두께가 얇을수록 소자 불안정성이 큰 것을 고려해야 됨을 알 수 있다.

히트싱크 미세채널 내의 입구유동 영역에서의 단상 열유동 특성에 관한 연구 (Study on Single-Phase Thermal and Hydrodynamic Characteristics in the Entry Region of a Mini-Channel Heat Sink)

  • 장용희;김용찬;이규정
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.1007-1016
    • /
    • 2006
  • Although the advance in electronic technology enables a large number of circuity to be packed in a small volume, it is simultaneously required to remove the high heat load produced by them. In this study, the heat transfer and pressure drop characteristics of a mini-channel heat exchanger, which is designed for liquid cooling of electronic components, are investigated by varying operating conditions. Water and FC-72 were used as working fluids. The mini-channel heat exchanger was made with circular shape channels having din-meters of 2, 3, and 4 mm in regular intervals, and the channel length was 100 mm. The header and inlet guide pathway to provide uniform inflow were attached at the inlet of the test section. Copper block including the heaters was attached at the sidewall of the test section as a heat source, which provided the heat flux from 5 to $15W/cm^2$. The entrance effects enhanced the heat transfer coefficient in the mini-channel significantly. In addition, the single-phase pressure drop in the mini-channel was very similar to that predicted by the laminar flow correlation except that the transition Re decreased due to flow instability in the entrance region.

시간 지연이 있는 양방향 원격조작 제어 기술 동향

  • 서창훈;박성준;류제하
    • 제어로봇시스템학회지
    • /
    • 제17권2호
    • /
    • pp.27-35
    • /
    • 2011
  • This paper presents the state of the art of control strategies for bilateral teleoperation systems under time delays. In the bilateral teleoperation that has force feedback, the time delay in the communication channel is the main source of instability. To cope with this problem. a number of control methods have been proposed. Among many control strategies. key aspects of the recent passivity-based methods are mainly summarized for approaches with wave variables. PO/PC (passivity observer/passivity controller), simple PD, and energy bounds.

채널 내 부착된 입방체 장애물 주위 유동에 관한 LES 난류모델의 영향 평가 (EVALUATION ON TURBULENT MODEL IN LARGE EDDY SIMULATION OF TUHANNEL FLOW AROUND A WALL-MOUNTED CUBE IN A CHANNEL)

  • 박남섭;고상철
    • 한국전산유체공학회지
    • /
    • 제13권3호
    • /
    • pp.28-34
    • /
    • 2008
  • In engineering application of large eddy simulation, there are still questions as follows grid dependency on numerical results, the effect of upwind scheme against a calculation instability, appropriate boundary conditions dealing with turbulence fluctuation and the performance of SGS models. In this study, in order to develop the LES to the engineering application, large eddy simulation was carried out to investigate the effect of upwind scheme, turbulent subgrid model and the grid dependancy of the flow around a wall-mounted cube in a channel at Re=40,000 based on cubic height and bulk mean velocity. The computed velocities, turbulence quantities, separation and reattachment length were evaluated compared with the experimental results of R. Matinuzzi and C. Tropea.