• Title/Summary/Keyword: and Average gap

Search Result 641, Processing Time 0.025 seconds

Evaluation of the Usefulness for Air Gap Technique in Digital Magnification Mammography (디지털 유방확대촬영술에서 Air gap technique의 유용성 평가)

  • Kim, Mi-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.101-107
    • /
    • 2014
  • The purpose of this study was investigated optimal exposure condition in digital magnification mammography to decrease radiation dose and increase image quality of the examinee. Auto mode, the average glandular dose is higher than the manual mode. Average glandular dose and image quality were many differences on between grid and air gap technique in auto mode. However, Average glandular dose and signal-to-noise ratio were not different on between grid and air gap technique in manual mode. The signal-to-noise ratio was increased when using the air-gap technique in both mode. According to result, air gap technique may reduce average glandular dose and increase signal-to-noise ratio in digital magnification mammography.

Characterization of Band Gaps of Silicon Quantum Dots Synthesized by Etching Silicon Nanopowder with Aqueous Hydrofluoric Acid and Nitric Acid

  • Le, Thu-Huong;Jeong, Hyun-Dam
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.1523-1528
    • /
    • 2014
  • Silicon quantum dots (Si QDs) were synthesized by etching silicon nanopowder with aqueous hydrofluoric acid (HF) and nitric acid ($HNO_3$). Then, the hydride-terminated Si QDs (H-Si QDs) were functionalized by 1- octadecene (ODE). By only controlling the etching time, the maximum luminescence peak of octadecylterminated Si QDs (ODE-Si QDs) was tuned from 404 nm to 507 nm. The average optical gap was increased from 2.60 eV (ODE-Si QDs-5 min) for 5 min of etching to 3.20 eV (ODE-Si QDs-15 min) for 15 min of etching, and to 3.40 eV (ODE-Si QDs-30 min) for 30 min of etching. The electron affinities (EA), ionization potentials (IP), and quasi-particle gap (${\varepsilon}^{qp}_{gap}$) of the Si QDs were determined by cyclic voltammetry (CV). The quasi-particle gaps obtained from the CV were in good agreement with the average optical gap values from UV-vis absorption. In the case of the ODE-Si QDs-30 min sample, the difference between the quasi-particle gap and the average optical gap gives the electron-hole Coulombic interaction energy. The additional electronic levels of the ODE-Si QDs-30 min and ODE-Si QDs-15 min samples determined by the CV results are interpreted to have originated from the Si=O bond terminating Si QD.

THE EFFECT OF ADHESIVE CURING TIMING ON THE DIRECTION OF POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN (상아질 접착제의 중합 시간 조절에 따른 복합레진의 중합 수축 방향의 변화)

  • 배지현;오명환;김창근;손호현;엄정문;조병훈;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.316-325
    • /
    • 2001
  • The purpose of this study was to evaluate the effect of adhesive curing timing on the direction of polymerization shrinkage of light-curing composite resin. In this study, the curing times of adhesive and composite resin were measured by differential scanning calorimeter(DSC). 28 extracted human molars were embedded in clear resin and box-type cavities were prepared. Based on DSC data, the experimental teeth were divided into 4 groups. Group 1: no bond; Group 2: late curing; Group 3: Intermediate curing; Group 4: Early curing. After treating with adhesive, the buccal cavities were filled with Z-100 hybrid composite resin and the lingual ones were filled with AEliteflo flowable composite resin. The depressions at the surface were measured by surface profilometer, then the specimens were embedded in clear resin and sectioned. Impressions were obtained and used to get epoxy resin replicas. The epoxy replicas were gold-coated and observed under SEM. Average Maximum Gap(AMG), Gap Proportion(GP), Average Marginal Index(AMI) were used to compare the shrinkage gap of each group. The results were statistically analyzed using the Kruskal-Wallis One Way ANOVA, Student-Newman-Keuls method. The results of this study were as follows. 1. Average Maximum Gap, Gap Proportion, Average Marginal Index and depression at the surface or Z-100 hybride composite resin were smaller than those of AEliteflo flowable composite resin(P<0.05). 2. When the bonding between composite resin and tooth structure was strong, the shrinkage gap was small, and depression at the surface was deep(P<0.05). 3. In the well-bonded group, light-curing composite resin shrank toward bonded cavity wall, not toward light source. The result suggested that the direction of polymerization shrinkage was affected by the quality of bonding in the dentin-resin interface. The strong was the bonding between composite resin and tooth structure, the smaller was the gap and the deeper was the depression at the surface. Then the flow to compensate the polymerization shrinkage proceeded from surface to bonded cavity wall.

  • PDF

An Empirical Study on the Wage Gap by Industries (산업별로 본 성별 임금격차에 관한 연구)

  • Shin, Kyung-Soo
    • Management & Information Systems Review
    • /
    • v.20
    • /
    • pp.61-83
    • /
    • 2007
  • This study estimates gender wage gap by the Korean industries. The empirical findings are as follows: 1. The sex segregation by industries has not improved. 2. The average wage in $\ulcorner$electricity, transportation, warehousing, financial institutions$\lrcorner$ is relatively higher than others. On the contrary, the average wage in $\ulcorner$mining and manufacturing$\lrcorner$ and $\ulcorner$wholesale and retail, food, loading$\lrcorner$ is relatively lower than others. 3. The gender wage gap in $\ulcorner$electricity, transportation, warehousing, financial institutions$\lrcorner$ is relatively lower than others. On the contrary, the gender wage gap in $\ulcorner$mining and manufacturing$\lrcorner$ is relatively higher than others. The gender wage gap has declined annually. The gender wage gap in industries with lower wage level is higher. The decline of gender wage gap cannot be interpreted as a relaxation of sexual discrimination.

  • PDF

Evaluation of Reductive Effect of Exposure Dose by Using Air Gap Apron in Nuclear Medicine Related Work Environment (핵의학과 내 작업 환경에서 공기층 납치마의 피폭선량 감소 효과 평가)

  • Lee, Wang-Hui;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.12
    • /
    • pp.845-853
    • /
    • 2014
  • In this study, we measured the dose reaching the OSLD dosimeter by using the regular lead apron, and air gap apron through 3 experiments, and researched the reductive effect of air gap apron on exposure dose based on the 140 keV gamma ray radiating from $^{99m}technetium$, which is the most commonly used in nuclear medicine. As a result, when the gap between the dosimeter and 0.2mm lead plate is 0 Cm, the average value of 10 dosimeters was 0.515 mSv, and when the gap between the dosimeter and lead plate is 20 Cm, the average value of 10 dosimeters was 0.138 mSv, which shows reductive effect of dose as much as 0.388 mSv. When the gap between the dosimeter and 0.5mm lead plate is 0 Cm, the average value of 10 dosimeters was 0.296 mSv, and when the gap between the dosimeter and lead plate is 20 Cm, the average value of 10 dosimeters was 0.075 mSv, which shows reductive effect of dose as much as 0.221 mSv. As we check the cumulative dosage for 3 days, the lead apron without air layer shows average 0.239 mSv, and the air gap apron shows 0.176 mSv, which is actually reduced by 0.062 mSv. As we check the cumulative dosage for a month, the lead apron without air layer shows 0.59 mSv, and the air gap apron shows 0.54 mSv, which is reduced by 0.05 mSv.

Research for Lateral Penumbra and Dose Distribution When Air Gap Changing in Proton Therapy Case (양성자치료시 Air Gap 변화에 따른 Lateral Penumbra와 선량분포 변화에 대한 비교 및 연구)

  • Kim, Jae-Won;Sim, Jin-Seob;Jang, Yo-Jong;Kang, Dong-Yun;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.47-51
    • /
    • 2010
  • Purpose: In the treatment of high-energy protons Air gap (the distance between the patient and the exit Beam) Lateral Penumbra of the changes to the increase in the radiation fields can form unnecessary and Increase the maximum dose at the site of treatment and reduced the minimum dose homogeneity of dose distributions can decline. Air gap due to this change in dose distribution compared to investigate studied. Materials and Methods: Received proton therapy at our institution Lung, Liver patients were selected and the size of six other Air gap in Field A and Field B 2, 4, 6, 8, 10 cm Proton external beam planning system by setting up a treatment plan established. Air gap according to the Lateral Penumbra area and DVH (Dose Volume Histogram) to compare the maximum dose and minimum dose of PCTV areas were compared. In addition, the dose homogeneity within PCTV Homogeneity index to know the value and compared. Results: Air gap (2, 4, 6, 8, 10 cm) at each change in field size were analyzed according to the Lateral Penumbra region Field A Change in the Air gap 2~10 cm by 1.36~1.75 cm, the average continuously increased about 28.7% and Field B Change in the Air gap 2~10 cm by 1.36~1.75 cm, the average continuously increased about 31.6%. The result of DVH analysis for relative dose of the maximum dose According to Air gap 2~10 cm is the mean average of 110.3% from 108.1% to a sustained increased by approximately 2.03% and The average relative dose of minimum dose is the mean average of 93.9% percent to 90.8 percent from the continuous decrease of about 3.31 percent. The result of Homogeneity index value to the according to Air gap 2~10 cm is the 2-fold increase from 1.09 to 2.6. Conclusion: In proton therapy case, we can see the increasing of lateral penumbra area when airgap getting increase. And increasing of Dmax and decreasing Dmin in the field are making increase homogeneity index, So we can realize there are not so good homogeneity in the PCTV. Therefore we should try to minimize air gap in proton therapy case.

  • PDF

Counter-Current Air-Water Flow in Narrow Rectangular Channels With Offset Strip Fins

  • Kim, Byong-Joo;Sohn, Byung-Hu;Koo, Kee-Kahb
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.429-439
    • /
    • 2003
  • Counter-current two-phase flows of air- water in narrow rectangular channels with offset strip fins have been experimentally investigated in a 760 mm long and 100 mm wide test section with 3.0 and 5.0 mm gap widths. The two-phase flow regime, channel-average void fractions and two-phase pressure gradients were studied. Flow regime transition occurred at lower superficial velocities of air than in the channels without fins. In the bubbly and slug flow regimes, elongated bubbles rose along the subchannel formed by fins without lateral movement. The critical void fraction for the bubbly-to-slug transition was about 0.14 for the 3 mm gap channel and 0.2 for the 5 mm gap channel. respectively. Channel-average void fractions in the channels with fins were almost the same as those in the channels without fins. Void fractions increased as the gap width increased, especially at high superficial velocity of air. The presence of fins enhanced the two-phase distribution parameter significantly in the slug flow, where the effect of gap width was almost negligible. Superficial velocity of air dominated the two-phase pressure gradients. Liquid superficial velocity and channel gap width has only a minor effect on the pressure gradients.

Comparison of Customer Satisfaction by Type of Foodservices in a Contract Foodservice Company (위탁급식업체의 급식유형별 고객만족도 비교)

  • An, Jeong-Ha;Moon, Hye-Kyung
    • Journal of the Korean Dietetic Association
    • /
    • v.14 no.2
    • /
    • pp.114-126
    • /
    • 2008
  • The purpose of this study was to gauge customers' satisfaction with the hospital, university, factory, and office foodservices from a contracted provider. Importance-performance analysis (IPA) evaluations were conducted. Questionnaires were returned from 1,808 customers in 46 foodservice locations. The average total scores of the importance and performance of seventeen quality characteristics were 4.14 and 3.23, respectively, on 5-point scales. The average total score of gap (gap = performance - importance) was -0.92. Analysis of significant difference according to the type of foodservices revealed that, hospital foodservices had more items with significant high scores than those of other groups in the average total scores concerning importance (p<0.01) and performance (p<0.01). The average total scores of gap showed no significant difference. Significant differences were evident in the food and personal service dimensions, and the scores of hospital foodservices trended significantly higher than those of other groups. Importance-performance analysis (IPA) analyses for hospital foodservice implicate 'variety of menu', 'cleanness of dishes', and 'taste of food' as items requiring prompt attention and improvement.

  • PDF

Risk Assessment of Groundwater Used for Washing GAP-certified Agricultural Crops after Harvest (GAP 농산물의 수확 후 처리에 사용되는 지하수의 위해성평가)

  • Kim, Hwang-Yong;Paik, Min-Kyoung;Kim, Areumnuri;Lee, Dong Gyu;Jeong, Mihye;Kim, Won-Il;Oh, Jin-A;Kim, Se-Ri;Hong, Su-Myeong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.6
    • /
    • pp.551-556
    • /
    • 2019
  • Recently, due to the fact that the mineral content in the wash water of the GAP-certified melon exceeds the GAP wash water standards, there are cases where the certification cannot be maintained. Therefore, agricultural industry demand requesting relaxation of the inorganic elements standard for water quality has been increasing, taking into account the consumption characteristics of Korean melon, which is eaten after removing the peel. This study was conducted to evaluate the human risks of four inorganic materials (fluorine, arsenic, iron and manganese) based on the water quality data of 142 samples of groundwater that was used for washing GAP-certified Korean melon in Seongju area from 2017 to 2019. As a result, the HQ of four minerals in Koreans who consumed groundwater used for washing GAP-certified Korean melons in the Seongju area was below 0.10 on average. In particular, in the case of iron and manganese which are esthetic influence substances, the average HQ was 0.00. The overexposure group showed 0.01, which was lower than the HQ (average 0.01, overexposure group 0.03) of the group that consumed Korean melon. Based on all the results, even if the groundwater of the Seongju area is used to wash GAP-certified Korean melon, the impact from these four inorganic materials, including iron and manganese, for Korean population consuming Korean melon will be minimal.

Analysis of Control Performance in Gap Size of MR Damper (MR Damper의 Gap Size에 따른 제어성능 분석)

  • Heo, Gwang Hee;Jeon, Seung Gon;Seo, Sang Gu;Kim, Dae Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.41-50
    • /
    • 2021
  • In this study, the flow path width (Gap Size), which is the flow path of fluid, was selected differently among various factors that determine the Ccontrol Force of MR damper, and the change of Control Force was confirmed accordingly. For this purpose, two MR dampers with a Gap Size of 1.0mm and 1.5mm were fabricated, respectively, and dynamic load experiments were conducted according to changes in applied current and vibration conditions The experimental results showed that the minimum Control Force was 3.2 times higher than 1.5mm in the case of 1.0mm Gap Size, and the maximum Control Force was 2.3 times higher than 1.5mm in the case of 1.0mm Gap Size. In addition, the increased width of the Control Force according to applied current was 34N for Gap Size 1.0mm, and 12.7N for Gap Size 1.5mm. As the gap Size increased, the overall Control Force and the increase in the Control Force by the applied current decreased. Next, the dynamic range, which is a performance evaluation index of the semi-active Control device, was 2.3 on average under 1.0mm condition and 2.8 on average under 1.5mm condition, confirming the possibility of utilization as a semi-active Control device.