• Title/Summary/Keyword: analytical precision

Search Result 818, Processing Time 0.026 seconds

Exposure Assessment of Heavy Metals Migrated from Glassware on the Korean Market (국내 유통 식품용 유리제의 중금속 노출 평가)

  • Kim, Eunbee;Hwang, Joung Boon;Lee, Jung Eun;Choi, Jae Chun;Park, Se-Jong;Lee, Jong Kwon
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.1
    • /
    • pp.15-21
    • /
    • 2022
  • The purpose of our study was to investigate the migration level of lead (Pb), cadmium (Cd), and barium (Ba) from glassware into a food simulant and to evaluate the exposure of each element. The test articles were glassware, including tableware, pots, and other containers. Pb, Cd, and Ba were analysed by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). The analytical performance of the method was validated in terms of its linearity, limit of detection (LOD), limit of quantification (LOQ), recovery, precision, and uncertainty. The monitoring was performed for 110 samples such as glass cups, containers, pots, and bottles. a food simulant. Migration test was conducted at 25? for 24 hours in a dark place using 4% acetic acid as a food simulant. Based on the data; exposure assessment was carried out to compare the estimated daily intake (EDI) to the human safety criteria. The risk levels of Pb and Ba determined in this study were approximately 1.9% and 0.3% of the provisional tolerable weekly intake (PTWI) and tolerable daily intake (TDI) value, respectively, thereby indicating a low exposure to the population.

Analytical Method of Multi-Preservatives in Cosmetics using High Performance Liquid Chromatography (HPLC 를 이용한 화장품 중 살균보존제 다성분 동시분석법 연구)

  • Min-Jeong, Lee;Seong-Soo, Kim;Yun-Jeong, Lee;Byeong-Chul, Lee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.4
    • /
    • pp.321-330
    • /
    • 2022
  • This study attempted to establish an optimal multi-compound simultaneous analysis method that can secure reliable results for 15 - preservatives, 2 - sun screens and 1 - antioxidants of cosmetics using HPLC-PDA. Since the potential of hydrogen (pH) in the mobile phase affects the acid dissociation constant (pKa) of the preservatives, and the peak retention time shift and area change were observed. The peak separation condition was established by adjusting the pH to 0.1% H3PO4 addition (mL) when preparing the mobile phase. As a results of method validation, the linearity correlation coefficient (R2) of above 0.999 were obtained, and accuracy 87.9 ~ 101.1%, 0.1 ~ 7.6% precision for two types of cosmetics (cream and shampoo). It was found that the limit of detection (LOD) was 0.1 ~ 0.2 mg/kg and the limit of quantitation (LOQ) was 2.0 ~ 4.0 mg/kg. In addition, it was possible to simultaneously separate p-anisic acid, a natural compound that was difficult to separate in HPLC due to the small difference from methylparaben, a synthetic preservatives. Through this study, it will be effectively used to secure quality control and safety for compound that need restrictions on use cosmetics.

Study Analysis of Isocycloseram and Its Metabolites in Agricultural Food Commodities

  • Ji Young Kim;Hyochin Kim;Su Jung Lee;Suji Lim;Gui Hyun Jang;Guiim Moon;Jung Mi Lee
    • Korean Journal of Environmental Agriculture
    • /
    • v.42 no.1
    • /
    • pp.71-81
    • /
    • 2023
  • An accurate and easy-to-use analytical method for determining isocycloseram and its metabolites (SYN549431 and SYN548569) residue is necessary in various food matrixes. Additionally, this method should satisfy domestic and international guidelines (Ministry of Food and Drug Safety and Codex Alimentarius Commission CAC/GL 40). Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) was used to determine the isocycloseram and its metabolites residue in foods. To determine the residue and its metabolites, a sample was extracted with 20 mL of 0.1% formic acid in acetonitrile, 4 g magnesium sulfate anhydrous and 1 g sodium chloride and centrifuged (4,700 G, 10 min, 4℃). To remove the interferences and moisture, d-SPE cartridge was performed before LC-MS/MS analysis with C18 column. To verify the method, a total of five agricultural commodities (hulled rice, potato, soybean, mandarin, and red pepper) were used as a representative group. The matrix-matched calibration curves were confirmed with coefficients of determination (R2) ≥ 0.99 at a calibration range of 0.001-0.05 mg/kg. The limits of detection and quantification were 0.003 and 0.01 mg/kg, respectively. Mean average recoveries were 71.5-109.8% and precision was less than 10% for all five samples. In addition, inter-laboratory validation testing revealed that average recovery was 75.4-107.0% and the coefficient of variation (CV) was below 19.4%. The method is suitable for MFDS, CODEX, and EU guideline for residue analysis. Thus, this method can be useful for determining the residue in various food matrixes in routine analysis.

Determination of Domoic Acid in Seafood Matrices using HPLC-UV with Solid Phase Extraction Cleanup (고체상 추출 전처리 및 HPLC-UV를 이용한 수산물 중 domoic acid의 분석)

  • Si Eun Kim;Sang Yoo Lee;Ji Eun Park;Hyunjin Jung;Hyang Sook Chun
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.297-304
    • /
    • 2023
  • Domoic acid (DA), a neurotoxin produced naturally by diatoms, is responsible for incidents of amnesic shellfish poisoning. In this study, a modified analytical method was established to determine domoic acid in seafood using solid phase extraction cleanup and optimizing the amount of sample and extraction solvent to reduce interference effects. The modified method using high-performance liquid chromatography with ultraviolet detection was validated using three seafood matrices (mussel, red snow crab, and anchovy) at three concentrations (1, 2, and 4 mg/kg) and compared to the Food Code method. Compared to the Food Code method, the modified method showed better performance in terms of linearity (R2>0.999), detection limit (0.02-0.03 mg/kg), quantification limit (0.05-0.09 mg/kg), intra-/inter-day accuracy (86.2-100.4%), and intra-/inter-day precision (0.2-4.0%). Furthermore, the method was successfully applied for the analysis of 87 seafood samples marketed in Korea, and DA was detected at a low concentration of 140 ㎍/kg in one anchovy sample. These results suggest that the modified method can be used for routine determination of DA in seafood.

Optimization of Analytical Methods for Octacosanol in Related Health-functional Foods with GC-MS (GC-MS를 이용한 건강기능식품 중 옥타코사놀 분석법 개발 연구)

  • Lee, Jin Hee;Oh, Mi Hyune;Lee, Kyung Jin;Kim, Yang Sun;Keum, Eun Hee;Park, Ji Eun;Cho, Mee Hyun;Seong, Min Hye;Kim, Sang A;Kim, Mee hye
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.4
    • /
    • pp.266-271
    • /
    • 2018
  • The Ministry of Food and Drug Safety (MFDS) is amending its test methods for health-functional foods (dietary food supplements) to establish regulatory standards and specifications in Korea. In this regard, we continue our research on developing analytical methods for the items. Octacosanol is the major component of polycosanol and is a high-molecular-mass primary fatty alcohol, obtained from sugar cane wax. Previous researchers have shown that octacosanol can lower cholesterol and has antiaggregatory properties, cytoprotective uses, and ergogenic properties for human health. Recently, octacosanol products have been actively introduced into the domestic market because of their functional biological activity. We have developed a sensitive and selective test method for octacosanol that the TMS derivatives by means of gas-chromatographic-tandem mass spectrometry (GC-MS). The trimethylsilyl ether derivative of the target analyte showed excellent chromatographic properties. The procedure was validated in the range of $12.5{\sim}200{\mu}g/L$. Standard calibration curves presented linearity with the correlation coefficient ($r^2$) > 0.999, and the limits of detection (LOD) and limits of quantitation (LOQ) were $4.5{\mu}g/L$ and $13.8{\mu}g/L$, respectively. The high recoveries (92.5 to 108.8%) and precision (1.8 to 2.4%) obtained are in accordance with the established validation criteria. Our research can provide scientific evidence to amend the octacosanol test method for the Health-Functional Food Code.

Development and Validation of Analytical Method for Pectolinarin and Pectolinarigenin in Fermented Cirsium setidens Nakai by Bioconversion (생물전환에 의한 발효 고려엉겅퀴 Pectolinarin 및 Pectolinarigenin의 분석법 개발 및 검증)

  • Oh, Ji-Won;Lee, Jin-Ha;Cho, Myoung-Lae;Shin, Gi-Hae;Kim, Jae-Min;Choi, Sun-Il;Jung, Tae-Dong;Kim, Young-Hyun;Lee, Sang-Jong;Lee, Bong Jin;Park, Seon Ju;Lee, Ok-Hwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.10
    • /
    • pp.1504-1509
    • /
    • 2015
  • The aim of this study was to investigate a validation method for determination of pectolinarin and pectolinarigenin in fermented Cirsium setidens Nakai. For validation, the specificity, linearity, precision, accuracy, detection limits, and quantification limits of pectolinarin and pectolinarigenin were measured by HPLC. The results show that the detection limits of pectolinarin and pectolinarigenin were $4.25{\mu}g/mL$ and $2.46{\mu}g/mL$, respectively. The recovery rates of pectolinarin and pectolinarigenin were high in the ranges of 99.7~104.0% and 99.7~102.4%, respectively. Inter-day and intra-day precisions of pectolinarin and pectolinarigenin in fermented Cirsium setidens Nakai were 0.9%, 0.5% and 0.5%, 0.2%, respectively. Therefore, application of pectolinarin and pectolinarigenin was validated by an analytical method as a marker compound in Cirsium setidens Nakai.

Residue analysis of penicillines in livestock and marine products (국내 유통 축·수산물 중 페니실린계 동물용의약품에 대한 잔류실태조사)

  • Song, Ji-Young;Hu, Soo-Jung;Joo, Hyun-Jin;Kim, Mi-Ok;Hwang, Joung-Boon;Han, Yoon-Jung;Kwon, Yu-Jihn;Kang, Shin-Jung;Cho, Dae-Hyun
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.257-264
    • /
    • 2012
  • Penicillins belong to the ${\beta}$-lactam class of antibiotics, and are frequently used in human and veterinary medicine. Despite the positive effects of these drugs, improper use of penicillins poses a potential health risk to consumers. This study has been undertaken to determinate multi-residues of penicillins, including amoxicillin, ampicillin, oxacillin, bezylpenicillin, cloxacillin, dicloxacillin, and nafcillin, using liquid chromatographic tandem mass spectrometer (LC-MS/MS). The developed method was validated for specificity, precision, recovery, and linearity in livestock and marine products. The analytes were extracted with 80% acetonitrile and clean-up by a single reversed-phase solid-phase extraction step. Six penicillins presented recoveries higher than 76% with the exception of Amoxicillin. Relative standard deviations (RSDs) were not more than 10%. The method was applied to 225 real samples. Benzylpenicillin was detected in 12 livestock products and 7 marine products. Amoxicillin, ampicillin, cloxacilllin, dicloxacillin, nafcillin and oxacillin were not detected. The detected levels were 0.001~0.009 mg/kg in livestock products excluding eggs and milk. In marine products, the detected levels were under 0.03 mg/kg. They were under the MRL levels. As monitoring results, it is identified to be safe but it is considered that safety management of antibiotics should continue by monitoring.

Simultaneous Determination of Water Soluble Vitamins B Group in Health Functional Foods etc. by HPLC (건강기능식품 등 중 수용성 비타민 B군의 HPLC를 이용한 동시분석법)

  • Kim, Seon Hee;Kim, Jae-Hyun;Lee, Hwa Jung;Oh, Jae Myoung;Lee, Sung Hye;Bahn, Kyeong Nyeo;Seo, Il Won;Lee, Young Joo;Lee, Jin Hee;Kang, Tae Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.143-149
    • /
    • 2015
  • This study was conducted to simultaneous analysis methods for water soluble vitamins B group (vitamin $B_1$, vitamin $B_2$, nicotinic acid, nicotinamide, vitamin $B_6$) which is used as health functional foods etc. Analytical methods of water-soluble vitamins B group by HPLC were established through instrumental analytical conditions, and the examination of data such as domestic and foreign reliable methods, and papers of journal. HPLC method analyzing water soluble vitamins B group was established using Capcell Pak C18 UG 120 column in 270 nm through test of columns. The validation has been performed on the method to determine linearity, accuracy, limits of quantification (LOQ) and repeatability for water soluble vitamins B group. An excellent linearity ($r^2=0.999$) was observed for vitamin $B_1$, vitamin $B_2$, nicotinic acid, nicotinamide, vitamin $B_6$ in the concentration range ($0.1{\sim}2{\mu}g/mL$). Observed recovery of vitamin $B_1$ was found to be between 100 and 103%, vitamin $B^2$ was found to be between 104 and 112%, nicotinic acid was found to be between 82 and 85%, nicotinamide was found to be between 121 and 124% and vitamin $B_6$ was found to be between 95 and 104%. LOQ of vitamin $B_1$ was found to be $0.04{\mu}g/mL$, vitamin $B_2$ was found to be $0.05{\mu}g/mL$, nicotinic acid was found to be $0.15{\mu}g/mL$, nicotinamide was found to be $0.08{\mu}g/mL$ and vitamin $B_6$ was found to be $0.63{\mu}g/mL$. Repeatability precision for vitamin $B_1$ was found to be 0.4%, vitamin $B_2$ was found to be 0.4%, nicotinic acid was found to be 0.5%, nicotinamide was found to be 0.7% and vitamin $B_6$ was found to be 0.4% relative standard deviation (RSD). Also, verify the accuracy of the simultaneous analysis methods, we monitored the labeled contents of the health functional foods and children's preferred foods.

Monitoring of Aflatoxins in Medicinal Herbs (유통 생약재의 아플라톡신 모니터링)

  • Kim, Yong-Hoon;Kang, Han-Saem;Oh, Sun-Woo;Lee, Hwa-Jung;Kim, Mi-Gyeong;Chung, So-Young;Choi, Seon-Hee;Bang, Su-Jin;Han, Kyung-Jin;Lee, Ji-Won;Kim, Young-Seon;Kim, Hee-Yun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.1
    • /
    • pp.27-32
    • /
    • 2010
  • This study was conducted to monitor aflatoxins in various medicinal herbs, providing available data for the safety of those products. To monitor aflatoxins in medicinal herbs, a total of 400 samples of 40 different herbs were collected in commercial retailers in Seoul, Daejeon, Gwangju, Daegu, and Busan from March to August, 2008. The samples that passed the sensory evaluation were tested for aflatoxins. Aflatoxins in samples were analyzed by HPLC-florescence coupled with photochemical enhancement. Samples were extracted with 70% methanol and then diluted to the appropriate concentration. A refining process was performed using an immunoaffinity column. The analytical method used in this study was validated. The $R^2$ value for aflatoxin $B_1$ was 0.99946, and the detection range was from 0.25 to 10.0 ng/mL. The accuracy of the analysis was ranged from 83.2% to 101.8%. The relative standard deviation (RSD) in the aflatoxin $B_1$ analysis was 3.4%, demonstrating the precision of this method. In addition, the detection limit and quantitative analysis limit of aflatoxin $B_1$ was $0.53\;{\mu}g/kg$ and $1.76\;{\mu}g/kg$, respectively. These results indicated that the analytical method used in this study was appropriate. The results of HPLC showed that 1% (4 samples) of the samples may contain aflatoxins. The concentration of quantified aflatoxin was $2.3\;{\mu}g/kg$ for both Quisqualis fructus and Remotiflori radix samples. The other samples were below the limit of quantification. Moreover, the concentration of aflatoxin $B_1$ which is made by specific fungi were below the level of regulation. Only 20% of aflatoxin $B_1$ were transferred to hot water. Therefore, the levels of aflatoxins in medicinal herbs were considered to be safe especially considering the aflatoxin transfer ratio.

A Study of Reportable Range Setting through Concentrated Control Sample (약물검사에서 관리시료의 농축을 이용한 보고 가능 범위의 설정에 대한 연구)

  • Chang, Sang Wu;Kim, Nam Yong;Choi, Ho Sung;Park, Yong Won;Yun, Keun Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.1
    • /
    • pp.13-18
    • /
    • 2004
  • This study was designed to establish working range for reoportable range in own laboratory in order to cover the upper and lower limits of the range in test method. We experimented ten times during 10 days for setting of reportable range with between run for method evaluation. It is generally assumed that the analytical method produces a linear response and that the test results between those upper and lower limits are then reportable. CLIA recommends that laboratories verify the reportable range of all moderate and high complexity tests. The Clinical Laboratory Improvement Amendments(CLIA) and Laboratory Accreditation Program of the Korean Society for Laboratory Medicine states reportable range is only required for "modified" moderately complex tests. Linearity requirements have been eliminated from the CLIA regulations and from others accreditation agencies, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. It is important to assess the useful reportable range of a laboratory method, i.e., the lowest and highest test results that are reliable and can be reported. Manufacturers make claims for the reportable range of their methods by stating the upper and lower limits of the range. Instrument manufacturers state an operating range and a reportable range. The commercial linearity material can be used to verify this range, if it adequately covers the stated linear interval. CLIA requirements for quality control, must demonstrate that, prior to reporting patient test results, it can obtain the performance specifications for accuracy, precision, and reportable range of patient test results, comparable to those established by the manufacturer. If applicable, the laboratory must also verify the reportable range of patient test results. The reportable range of patient test results is the range of test result values over which the laboratory can establish or verify the accuracy of the instrument, kit or test system measurement response. We need to define the usable reportable range of the method so that the experiments can be properly planned and valid data can be collected. The reportable range is usually defined as the range where the analytical response of the method is linear with respect to the concentration of the analyte being measured. In conclusion, experimental results on reportable range using concentrated control sample and zero calibrators covering from highest to lowest range were salicylate $8.8{\mu}g/dL$, phenytoin $0.67{\mu}g/dL$, phenobarbital $1.53{\mu}g/dL$, primidone $0.16{\mu}g/dL$, theophylline $0.2{\mu}g/dL$, vancomycine $1.3{\mu}g/dL$, valproic acid $3.2{\mu}g/dL$, digitoxin 0.17ng/dL, carbamazepine $0.36{\mu}g/dL$ and acetaminophen $0.7{\mu}g/dL$ at minimum level and salicylate $969.9{\mu}g/dL$, phenytoin $38.1{\mu}g/dL$, phenobarbital $60.4{\mu}g/dL$, primidone $24.57{\mu}g/dL$, theophylline $39.2{\mu}g/dL$, vancomycine $83.65{\mu}g/dL$, valproic acid $147.96{\mu}g/dL$, digitoxin 5.04ng/dL, carbamazepine $19.76{\mu}g/dL$, acetaminophen $300.92{\mu}g/dL$ at maximum level.

  • PDF