Characteristics of Alpha Particle Track on Cellulose Nitrate Film (Cellulose Nitrate의 알파입자비적특성(粒子飛跡特性))

  • Do, Jin-Yeol;Jun, Jae-Shik;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.61-66
    • /
    • 1984
  • A study on the characteristics of ${\alpha}$-particle track on cellulose nitrate film was carried out with a particular emphasis on the dependence of track diameter upon chemical etching condition. The track diameters etched in KOH solution appeared to be, on average, three times larger than those etched in NaOH under the same etching condition. The relationship between the track diameters and both etching time and the energy of incident ${\alpha}$-particles was also investigated. It is shown that the particle fluence rate is fairly independent of etching time as far as the condition of irradiation remains unchanged.

  • PDF

PRELIMINARY STUDY ON THE ALPHA TRACK ANALYSIS OF SPHERICAL URANIUM METAL PARTICLES

  • Pyo Hyung-Yeol;Kim Jong-Yun;Lee Myung-Ho;Park Yong-Jun;Jee Kwang-Yong;Kim Won-Ho
    • Nuclear Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.353-358
    • /
    • 2006
  • Alpha track analysis for the determination of the trace amount of alpha emitting nuclides in a very small particle was performed as an efficient and powerful technique during safeguard inspection. Metal particles with well-defined spherical shape, size and isotopic compositions as a reference material were used to correlate the number of tracks or track diameter with an isotopic composition eventually to identify the uranium enrichment in the environmental swipe samples. Slopes in the number of tracks versus the exposure time curve provide a simple insight into the uranium enrichment of an unknown particle. Low enriched uranium metal particles result in slopes still steeper than the depleted or natural uranium metal particles. In addition, a linear relationship between track diameter and particle size Is thought to be a useful first stage analytical tool as an efficient and convenient inspection guide. The significance of the simple linear model was also judged using the usual statistical tests.

Study on the Enhancement of Reproducibility for Track Technology Using a Multi-dot Plate (다중시료 점적판을 이용한 트랙기입법의 재현성 증대 연구)

  • Park, Y.J.;Pyo, H.Y.;Song, B.C.;Jee, K.Y.
    • Analytical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.434-437
    • /
    • 2004
  • Alpha track technology can provide useful isotopic information of boron in the primary coolant water. In the quantitative analysis using the alpha track analysis, the shape or area of sample on the solid track detector becomes very important, especially for the analysis of liquid samples. In this research, a multi-dot plate has been developed for this purpose. The multi-dot plate provides fixed standard shape of the sample solution that stays inside of the printed circle, and consequently increases the reproducibility of the boron analysis.

Growth and Decay of Alpha Tracks in a Large Scale Cloud Chamber after Injection of Radon

  • Wada, Shinichi;Kobayashi, Tsuneo;Katayama, Yoshiro;Iwami, Toshiaki;Kato, Tsuguhisa;Cameron, John R.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.275-278
    • /
    • 2002
  • The recognition of the natural background radiation is important not only for radiological education but also for the promotion of people's scientific view about radiation. We made a "room" on the web showing natural background radiation as part of a VRM (Virtual Radiation Museum). The "room" shows the video images of the tracks of charged particles from natural background radiation, alpha and beta ray track from known sources using a Large Scale Diffusion Cloud Chamber. The purpose of this study is to make clear the origin of a kind of track (named A-track) which is thick and easy to recognize with the length less than several cm in the cloud chamber, and to make numerical explanation of its counting rate. The study was carried out using a Large Scale Diffusion Cloud Chamber (Phywe, Germany) installed in the Niigata Science Museum. The Model RNC (Pylon Electronics, Canada) was used as Rn-222 source. Ra-226 activity in RNC was 111.6 Bq calibrated with NIST protocol. Rn-222 gas was injected into the cloud chamber. Continuous video recording with use of Digital Handycam (SONY, Japan) was carried out for 360 min. after injection of Rn-222 gas. The number of alpha-ray track (alpha track) in the video images was analyzed. The growth and decay curve of the total activity of Rn-222 and its alpha emitting progeny were calculated and compared with the count of the alpha tracks. As a result the alpha tracks formed by Rn-222 injection resemble A-Tracks. The relationship between A-track in the cloud chamber and atmospheric Rn is discussed.

  • PDF

Determination of Boron Isotopic Ratio by Using an Alpha Track Technique

  • Park, Yong-Joon;Pyo, Hyung-Yeal;Song, Kyu-Seok;Song, Byoung-Chul;Jee, Kwang-Yong;Kim, Won-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.10
    • /
    • pp.1609-1612
    • /
    • 2006
  • The determination of the boron isotopic ratio in solutions was achieved by means of a solid state track detector by using an alpha track. The neutron flux was optimized by using a Cd-foil to find the optimum conditions for counting the number of alpha tracks on the selected solid detector caused by the (n, $\alpha$) nuclear reaction of boron. The home-made multi-dot detector plate was utilized in this study to increase the reproducibility of the measurement by uniformly drying the boron solution within the marked circle area on the detector plate. The experimental results of this study verified that the $^{11}B/^{10}B $ isotopic ratio can be measured by observing the number of alpha tracks for different concentrated standard solutions with various isotopic compositions. This technique was applied to the determination of $^{10}B$ enrichment factor in a biological sample for a boron neutron capture therapy.

An Automotive Radar Target Tracking System Design using ${\alpha}{\beta}$ Filter and NNPDA Algorithm (${\alpha}{\beta}$ 필터 및 NNPDA 알고리즘을 이용한 차량용 레이더 표적 추적 시스템 설계)

  • Bae, JunHyung;Hyun, EuGin;Lee, Jong-Hun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.6 no.1
    • /
    • pp.16-24
    • /
    • 2011
  • Automotive Radar Systems are currently under development for various applications to increase accuracy and reliability. The target tracking is most important in single or multiple target environments for accuracy. The tracking algorithm provides smoothed and predicted data for target position and velocity(Doppler). To this end, the fixed gain filter(${\alpha}{\beta}$ filter, ${\alpha}{\beta}{\gamma}$ filter) and dynamic filter(Kalman filter, Singer-Kalman filter, etc) are commonly used. Gating is used to decide whether an observation is assigned to an existing track or new track. Gating algorithms are normally based on computing a statistical error distance between an observation and prediction. The data association takes the observation-to-track pairings that satisfied gating and determines which observation-to-track assignment will actually be made. For data association, NNPDA(Nearest Neighbor Probabilistic Data Association) algorithm is proposed. In this paper, we designed a target tracking system developed for an Automotive Radar System. We show the experimental results of the 77GHz FMCW radar sensor on the roads. Four tracking algorithms(${\alpha}{\beta}$ filter, ${\alpha}{\beta}{\gamma}$ filter, 2nd order Kalman filter, Singer-Kalman filter) have been compared and analyzed to evaluate the performance in test scenario.

Detection of Alpha Tracks of Boron by Nuclear Reaction with Neutron (중성자 핵반응에 의한 보론의 알파트랙 검출)

  • Sohn, Se Chul;Pyo, Hyung Yeal;Park, Yong Jun;Jee, Kwang Yong;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.8-15
    • /
    • 2004
  • The detection efficiencies of the several solid track detectors were investigated for the determination of boron content in aqueous solution by using the alpha muti-Radioisotope(RI) source. Polycarbonate (Lexan and CR-39) and cellulose nitrate (CN-85 and LR-115) were selected as materials for alpha track detection of boron. Alpha muti-RI source, uranium metal particles and boron standard solution were used for alpha emission. In this study, four solid track detectors(CN-85, LR-115, Lexan and CR-39) were characterized under various etching conditions as well as neutron irradiation conditions. As a result, the CN-85 was turned out to be best to provide good efficiency among the four detectors. The selected solid track detector was utilized for the determination of trace amount of boron in aqueous sample and its results were discussed in the text.

A Study for Assessment of Track Accuracy of Phased Array Radar Associated with α-β Filter (α-β 필터를 사용한 위상배열 레이더의 실표적 추적 정확도 평가 알고리듬 연구)

  • Shin, Sang-Jin;Kim, Wan-Gyu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.9
    • /
    • pp.828-836
    • /
    • 2015
  • In this paper, the assessment technique for track accuracy in the phased array radar is proposed. It is assumed that ${\alpha}-{\beta}$ tracking filter to track the target is established in the phased array radar. In order to assess the track accuracy strictly, we should use the real target position data acquired from the special instrument, ACMI(Air Combat Maneuvering Instrument) pod or DGPS(Differential Global Positioning System). However, this method leads to increase the experiment cost and test time. We derive the relationship between the residuals of tracking filter and the standard deviations of range and angle tracking errors which are assigned as track assessment index. The theory of sample variance is introduced in this assessment because track accuracy has to be calculated with many residual samples.

Theoretical Calculation on Alpha Track Density by Using an Electrostatic Ion Spectrometer (정전기분광분석방법에 의한 알파입자비적밀도의 이론적 계산연구)

  • Yoon, Suk-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.25-35
    • /
    • 1993
  • To develop a technique of theoretical alpha track density calculation for comparison with measured track density, an electrostatic ion spectrometer was specially designed and fabricated. The mobility spectrum of first radon daughter(Po-218) in the range of $0.07{\sim}5.0cm^2/V\;s$ from the radon chamber was measured using-the electrostatic ion spectrometer. Measurement was taken in a radon chamber operated using dry particle free air passed through silica gel, activated charcoal and molecular sieve filters. The mobility of a new-born Po-218 ion measured by the electrostatic ion spectrometer was determined to be $1.92cm^2/V\;s$. A comparison of the theoretical and measured alpha track densities was completed and uncertainties concerning the shape of the spectrum were analyzed. It was found that the discrepancies in track densities are primarily Que to the neglect of wall loss of ions in the theoretical track density calculation.

  • PDF