Abstract
The detection efficiencies of the several solid track detectors were investigated for the determination of boron content in aqueous solution by using the alpha muti-Radioisotope(RI) source. Polycarbonate (Lexan and CR-39) and cellulose nitrate (CN-85 and LR-115) were selected as materials for alpha track detection of boron. Alpha muti-RI source, uranium metal particles and boron standard solution were used for alpha emission. In this study, four solid track detectors(CN-85, LR-115, Lexan and CR-39) were characterized under various etching conditions as well as neutron irradiation conditions. As a result, the CN-85 was turned out to be best to provide good efficiency among the four detectors. The selected solid track detector was utilized for the determination of trace amount of boron in aqueous sample and its results were discussed in the text.
수용액 시료에 포함된 미량의 보론 함량을 분석하는데 적합한 고체트랙 검출기를 선정하기 위하여 알파복합선원 등을 이용하여 검출능력을 비교 검토하였다. 보론의 알파트랙 검출에는 polycarbonate 재질(Lexan 및 CR-39)과 cellulose nitrate 재질(CN-85 및 LR-115))의 고체트랙 검출기를 사용하였다. 알파입자 방출물질로는 복합알파선원, 금속 우라늄 입자 및 보론 표준용액을 사용하였다. 본 연구에서는 에칭조건 및 중성자 조사조건 등에 따른 검출기의 특성을 비교하였으며, 실험 결과 보론 정량에는 CN-85 검출기가 가장 적합한 것을 알 수 있었다. 또한, 선정된 검출기를 이용하여 수용액 매질에 포함된 미량의 보론을 알파트랙 기입방법으로 측정한 실험결과에 대해 검토하였다.