• 제목/요약/키워드: all-in-one

검색결과 24,974건 처리시간 0.046초

레디믹스트 숏크리트의 현장 시공프로세스 분석 및 경제성 평가 (A Study of Field Construction Process Analysis and Economic evaluation of Ready-mixed Shotcrete)

  • 김동민;마상준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1322-1327
    • /
    • 2010
  • Ready-mixed shotcrete mixed with high quality materials and can be controled shotcrete quality is producted in plants and transported to construction fields, so do not need a field batch plant. In this study, the field construction system that can be applied Ready-mixed Shotcrete to construction fields was proposed, and the all-in-one silo that was the key component of the field construction system was design. It was performed to evaluate the constructability that the field construction process analysis in case of applying a field batch plant and the all-in-one silo, the cost analysis of the material production and transport in a road tunnel was also performed to evaluate the economic feasibility of Ready-mixed shotcret.

  • PDF

All-One Polynomial에 의해 정의된 유한체 $GF(2^m) $ 상의 새로운 Low-Complexity Bit-Parallel 정규기저 곱셈기 (A New Low-complexity Bit-parallel Normal Basis Multiplier for$GF(2^m) $ Fields Defined by All-one Polynomials)

  • 장용희;권용진
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제31권1_2호
    • /
    • pp.51-58
    • /
    • 2004
  • 대부분의 공개키 기반 암호시스템은 유한체 $GF(2^m)$ 상의 산술 연산들을 기반으로 구축된다. 이들 연산 중 덧셈을 제외한 다른 연산들은 곱셈 연산을 반복하여 계산되므로, 곱셈 연산의 효율적인 구현은 공개키 기반 암호시스템에서 매우 중요하다. 본 논문에서는 All-One Polynomial에 의해 정의된 $GF(2^m)$ 상의 효율적인 Bit-Parallel 정규기저 곱셈기를 제안한다. 게이트 및 시간적인 면에서 본 곱셈기의 복잡도(complexity)는 이전에 제안된 같은 종류의 곱셈기 보다 낮거나 동일하다. 또한, 본 논문의 곱셈기는 아키텍처가 규칙적(regular)이어서 VLSI 구현에 적합하다.

다초점 촬영과 초점후처리 기능을 가진 스마트폰 카메라 앱의 성능평가 (Performance Evaluation of Smartphone Camera App with Multi-Focus Shooting and Focus Post-processing Functions)

  • 박채원;김경미;유송연;김유진;황기태;정인환;이재문
    • 한국인터넷방송통신학회논문지
    • /
    • 제24권2호
    • /
    • pp.35-40
    • /
    • 2024
  • 본 논문은 이전 연구에서 구현된 OnePIC 앱의 실행 성능과 저장 성능을 분석하여 OnePIC 앱의 실용성을 검증한다. OnePIC 앱은 다양한 초점을 가진 사진들을 촬영한 후, 원하는 초점의 사진을 얻을 수 있는 카메라 앱이다. 본 논문은 성능평가를 위해 거리별 다초점 촬영 시간과 객체별 다초점 촬영 시간을 세부적으로 분석하였다. 성능평가는 실제 스마트폰에서 실측하는 방식으로 진행되었다. 거리별 다초점 촬영 시간은 5장에 0.84초, 객체 감지 시간은 객체 개수와 관계없이 0.19초, 객체별 다초점 촬영 시간은 5장에 4.84초 정도로 측정되었다. 다초점 사진을 한 장에 저장한 All-in-JPEG 파일 크기와 각각 JPEG 파일로 저장한 경우를 비교한 결과, All-in-JPEG 파일 크기가 미묘하게 줄어 저장공간의 큰 이득은 없었다. 그렇지만 All-in-JPEG은 다초점 촬영된 사진들의 관리 면에서 매우 용이하다. 결론적으로 본 논문의 성능평가 결과, OnePIC 앱은 촬영 시간과 사진의 저장 크기 및 관리 면에서 실용적인 것으로 판단된다.

맹종죽의 죽령별 조직 현미경적 관찰 (Microscopic Observation of Moso bamboo(Phyllostachys pubescens Mazel) with Various Ages)

  • 윤승락
    • 펄프종이기술
    • /
    • 제42권2호
    • /
    • pp.27-34
    • /
    • 2010
  • To obtain the basic information for the use of bamboo, the anatomical characteristics of moso bamboo shoots, and 20-day-old, 60-day-old, one-year-old, and two-year-old moso bamboo were observed by using polarizing microscope. The cross section showed that the bamboo shoots consists of the early stage of cell formation, atactostele, parenchyma, and bundle sheath was formed in 20-day-old moso bamboo, and all cells completely formed in 60-day-old moso bamboo. The tissues in one-year-old moso bamboo appeared to be completely matured. On the tangential surface, no atactostele was observed in the bamboo shoot, but metaxylem, parenchyma, and bundle sheath were found. atactostele and parenchyma appeared to be formed between 20 and 60 days. All tissues and cells were totally formed and the cell wall of parenchyma were completely matured after one year. The metaxylem in bamboo shoots was observed to have pits, which means that it could be the tissues first formed of all bamboo cells.

The effect of multiple application on microtensile bond strength of all-in-one dentin adhesive systems

  • Son, Sung-ae;Hur, Bock
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.567-567
    • /
    • 2003
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength using confocal laser scanning microscope and microtensile bond strength test. The dentin surface of human molars, sectioned to remove the enamel from the occlusal surface were prepared. In group I, Scotchbond Multipurpose(SM, 3M ESPE) was applied by manufature's recommended. In group II, after the all-in-one adhesive, Adper Prompt L-Pop was applied for 15s, and light cured for 10s, the second coat was re-applied and light-cured.(omitted)

  • PDF

연합판막질환의 판치환수술 (Double Valve Replacement: report of 5 cases)

  • 노중기
    • Journal of Chest Surgery
    • /
    • 제12권4호
    • /
    • pp.355-360
    • /
    • 1979
  • Mitral and aortic valve replacement with tricuspid annuloplasty was undertaken in 5 patients out of 38 valvular surgery between the period from Jan. 1977 to May 1979 in the Dept. of Thoracic and Cardiovascular Surgery in Korea University Hospital. All were male patients with age ranging from 18 to 42 years, and preoperative evaluation revealed one case in Class IV, and four cases in Class III according to the classification of NYHA. Preoperative diagnosis was confirmed by routine cardiac study including retrograde aorto- and left ventriculography, and there were two cases with MSi+ASi+Ti, two cases with MSi+Ai+Ti, and one case with Mi+Ai+Ti. Double valve replacement was performed under the hypothermic cardiopulmonary bypass with total pump time of 247 min. in average ranging from 206 min. to 268 min. During aortic valve replacement, left coronary perfusion was done in the first two cases, and cardiac arrest with cardioplegic solution proposed by Bretschneider was applied in the remained three cases. Starr-Edwards, Bjork-Shiley prosthetic valves and Carpentier-Edwards tissue valve were replaced in the aortic area, and Carpentier-Edwards and Angell-Shiley tissue valves were replaced in the mitral area with each individual combination [three prosthetic and two tissue valves in the aortic, and five tissue valves in the mitral area respectively]. Postoperative recovery was uneventful in all cases except one case with hemopericardium, which was managed with pericardiectomy on the postoperative 10th day in good result. Follow-up after double valve replacement of the all five cases for the period from 6 months to 33 months revealed satisfactory adaptation in social activity and occupation with cardiac function of Class I according to the classification of NYHA In all five cases.

  • PDF

외상으로 인한 재발성 단방향 견관절 후방 아탈구의 관절경을 이용한 후방낭 이동술 (Arthroscopic Posterior Capsular Shaft for Traumatic Recurrent Unidirectional Posterior Subluxation of the Shoulder)

  • 김승호;하권익;유재철;이용석;이희동
    • Clinics in Shoulder and Elbow
    • /
    • 제6권1호
    • /
    • pp.55-66
    • /
    • 2003
  • Background: The purpose of this study was to evaluated results of arthroscopic treatment of the traumatic recurrent unidirectional posterior subluxation. Materials and Methods: We treated twenty-seven patients who had traumatic recurrent unidirectional posterior subluxation of the shoulder by arthroscopic labral repair and posterior capsular shift and prospectively evaluated for a mean of thirty-nine months (range,24 to 85 months). Patients who had posteroinferior instability, multidirectional instability, atraumatic onset, or revision cases were excluded. There were twenty-five male and two female patients with the mean age of twenty-one years (range, 14 to 33 years). All patients were involved in sports activity. All had a significant traumatic event prior to the onset of the instability. Stability, motion, three objective measurement (UCLA, ASES, and Rowe scores) and two subjective measurements (pain and function visual analogue scale) were evaluated. Results: The most common finding in magnetic resonance image-arthrogram was separation of the posteroinferior labrum without displacement in 9 patients, In arthroscopic examination, all patients had one or more lesions in the posterior inferior labrum and capsule. The most common finding was incomplete stripping of the posterior inferior labrum (18 patients). The posteroinferior capsule subjectively appeared to be stretched in twenty-two patients. At follow-up, all patients had improved shoulder function and scores(p < 0.01). All patients had stable shoulder by subjectivel and objectivel measurements, except one patient who had recurrent subluxation. All but one patient with postoperative recurrence were able to return to their prior sports activity with little or no limitation. Twenty-four patients were graded as having more than 90% of shoulder function. Their were twenty-one excellent, five good, and one fair UCLA. scores. Pain sore improved from 4.5 to 0.2 point(p : 0.0001). Mean loss internal rotation was one vertebral level. None had operative complications. Conclusion: In conclusion, treatment outcomes of the traumatic unidirectional recurrent posterior subluxation are consistently reliable with respect to the stability, pain relief, and functional restoration by the arthroscopic posterior capsular shift procedure.

Clinical Features in 9 Dogs with Immune-Mediated Polyarthritis

  • Lim, Seula;Song, Kun-Ho;Seo, Kyoung-Won
    • 한국임상수의학회지
    • /
    • 제34권6호
    • /
    • pp.434-436
    • /
    • 2017
  • Nine dogs with history of lameness and anorexia were presented. On physical examination, all dogs had gait abnormality and six dogs had high body temperature. Their clinical signs were mostly episodic, and only non-specific symptoms were occasionally observed. Arthrocentesis was performed in all dogs, and immune-mediated polyarthritis (IMPA) was diagnosed. Definitive rheumatoid arthritis (RA) and systemic lupus erythematous (SLE) were diagnosed in one dogs, one each. Prednisolone (PDS) was chosen as the first-line therapy for all dogs, except for the one with RA. Most cases responded to PDS but some cases including those of SLE and RA were refractory to PDS. IMPA can be challenging to diagnose due to its vague symptom and is commonly implicated in 'fever of unknown origin'. Therefore, clinicians should consider IMPA as a differential diagnosis when the patient has fever with systemic, non-specific signs, such as anorexia and depression, but does not respond to antibiotics.

항공정비복 착용실태에 관한 연구 (A Study on the Actual Wearing Conditions of Working Uniform for the Aircraft Mechanic)

  • 임현주;최혜선;이경미;김수아
    • 한국의류학회지
    • /
    • 제30권9_10호
    • /
    • pp.1344-1353
    • /
    • 2006
  • The purpose of this research is to investigate the actual wearing conditions of working uniform and identify problems for the aircraft mechanic. For this study, questionnaire surveys were conducted dividing according to styles of clothing; one-piece and two-piece styles. Subjects were 343 men working in flight line. Questionnaire of 159 two-piece styles and 184 one-piece ones were used in analysis. The results of the study are as follows; The result about wearing each type of working uniform showed that the two-piece one is always as the air force uniform, whereas the one-piece one is worn only a few times. They felt inconvenience during all operations except in the sitting position, crawling position, and positions in which they were using tools. Accordingly, the result of the functionality reported dissatisfaction on all question items. Therefore, uniform of two-piece style achieved better results on all questions related to motional flexibility and functionality. Questions on changes to finishing methods showed that each airline employed different methods for both two-pieced and one-pieced uniforms. The answers about the unstitched or worn-out parts of the two-piece garments showed that pants were unstitched on the inner seam of the trouser leg and hip regions, but the upper one was not. In case of the one-pieced uniform, the parts of wearing out is the seam of hip and the unstitched parts are knee region and hem line of pants. Questions concerning their satisfaction with the material of uniforms indicated a high rate of dissatisfaction, particularly in its ventilation and absorbency. Questions concerning the preferred design of working uniform indicated a preference for two-piece uniform rather than one-piece ones.