• 제목/요약/키워드: airtight performance

검색결과 30건 처리시간 0.027초

박스형 이중외피와 커튼월 창호의 난방기 열적성능 비교 (A Study on thermal performance of box type double skin facade and curtain wall in heating period)

  • 박창영;최창호;이건호;윤용상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.909-914
    • /
    • 2006
  • The purpose of this study is to analyze the thermal of DFS(double Facade System) and curtain wall in the heating period. The physical difference between curtain wall and double facade on thermal performance has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. This study divide on 'ventilated, airtight' and 'heated or unheated' conditions from the CASE 1, 2, 3, 4. The results showed thermal performance of double facade system which has been better than curtain wall. The heating energy of DFS reduced $8%{\sim}10%$ of energy consumption. comparable to SFS in experemted results. In view of the researching results so far achieved, the research came to a conclusion, that the curtain wall can save the energy in the heating period than a curtain wall.

  • PDF

건축물 외부 중공벽의 시공방안에 관한 연구 - 외부 점토벽돌의 사용을 중심으로 - (A study on the technical details of masonry veneer and cavity walls - Focused on the out wyth of clay bricks -)

  • 양순갑
    • 한국주거학회논문집
    • /
    • 제8권3호
    • /
    • pp.219-230
    • /
    • 1997
  • Lack of technical standards, specification and inadequate execution in masonry wall construction in Korea lead to produce serious flaw problems such as crack, efflorescene, and upset etc.. The purpose of this paper is to present the practical details for Masonry cavity wall construction to prevent rain penetration and to accommodate differential movement between the inner and outer wythes of cavity walls. Considering rain penetration and differential movement of both wythes of cavity walls, provision of an adequate air space, an airtight back-up wall, clean cavity with weepholes and vents, properly positioned flashing, tie and shelf angle etc. depend on the cavity wall types will help ensure good performance. The present details included noncorrosive hot dip galvanized steel or stainless steel for metal components, plastic and ultra violet resistant polypropylene Copolymer for other components was taken into account the construction method and several types of cavity walls in Korea

  • PDF

무시멘트 경량패널 심재의 혼입재료 종류에 따른 유동 및 밀도, 흡수율 특성 (Strength and Density Properties according to mixing materials types of Non-cement light weight Panel core)

  • 경인수;김태현;이동훈;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.28-29
    • /
    • 2017
  • Recently, the tendency of the insulation of buildings to be important is making the buildings airtight. However, in order to get closer to the technology, it is necessary to improve the performance of walls and panels of buildings, but it is a problem due to the increase of the unit price. We will review the basic data on the density and table flow characteristics of high thermal insulation materials.

  • PDF

고기밀 고단열 주택의 기밀성능에 관한 실험적 연구 (Experimental Study on Airtightness Performance of the House with High Levels of Insulation and Airtight Construction)

  • 신우철;윤종호;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.61-67
    • /
    • 2005
  • The purpose of this study is to evaluate the air tightness of Zero Energy Solar House(ZeSH) and to propose the construction improvement of junctions and penetrations where air infiltration was identified. Air leakage rate were measured by means of blower door test in accordance with ASTM E779-87. The results showed that ZeSH has an excellent airtightness with ACH50/20 (air change per hour at a pressure difference of 50 Pa between inside outside) of 0.34hr-1 and leakage class E by normalized leakage area of ASHRAE.

공동주택의 기밀성능 평가 및 에너지 절감효과 분석 (An Evaluation of Airtightness Performance and Analysis of Energy Savings Potential in Apartment Housing)

  • 이승복
    • 태양에너지
    • /
    • 제15권3호
    • /
    • pp.119-125
    • /
    • 1995
  • 지금까지 우리는 건물분야에서의 합리적인 에너지 사용을 위하여 건물외피의 단열성능을 향상시킴으로써 열손실을 줄이려는 데에 주력하여 왔으며, 침기로 인한 열손실을 줄이려는 노력은 상대적으로 미흡하였다. 그러나, 침기로 인한 난방에너지의 소비가 상당량에 이르는 것으로 조사됨으로써 재실형태에 따라 최소환기기준을 만족시키면서 침기에 의한 불필요한 에너지의 손실을 줄이려는 노력이 매우 유효한 것으로 평가되고 있다. 실제로 침기에 의한 불필요한 에너지의 낭비가 얼마나 되는가를 평가하기 위해서는, 건물에서의 침기율을 정확하게 측정할 수 있는 방법이 전제되어야 한다. 본 연구에서는 감압/가압법의 일종인 Blower Door System을 사용하여 공동주택에서의 기밀성능을 측정, 평가함은 물론 측정결과를 토대로 합리적인 수준까지 기밀화할 경우 난방에너지의 절약가능성에 대하여 추정하였다.

  • PDF

공동주택 강제 환기 시스템의 건물에너지 측면에서의 장기적 운영 방안에 관한 연구 (A Study on the Long-term Operating plan of Ventilation System of Apartment House in terms of Energy Performance)

  • 김승철;윤종호;백남춘;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.115-123
    • /
    • 2011
  • Because buildings recently built have been highly insulated and highly airtight, it is impossible to emit toxic substances from interior finishing materials only by natural ventilation. Therefore, they cause indoor air pollution and it may threaten the user"s health such as atopic dermatitis, bronchial asthma and (allergic) rhinitis. Domestically, users spend indoors 80 percent of their time of a day. With the increased interest in indoor air quality, the introduction of forced ventilation system for new-built apartment buildings has been legislated. However, toxic substances from indoor are mostly below there commended standard approximately 23 months later. Thus, this study has assumed the status of the apartment buildings 23 months later through a simulation, regarded $CO_2$ as an exclusive indoor air pollution source. In the process of effectively eliminating the $CO_2$, this study has also been conducted on an operating plan that can provide superior performance from the energy side.

  • PDF

건물 구조 특성에 따른 기밀성능 및 난방 에너지 요구량 분석 - 신축 공동주택 중심으로 - (An Analysis of the Airtightness Performance and Heating Energy Demand According to Building Structural Characteristics -Focused on Newly Apartment Houses-)

  • 이수인;김정국;김서훈;김종훈;정학근;장철용
    • KIEAE Journal
    • /
    • 제15권2호
    • /
    • pp.109-115
    • /
    • 2015
  • Purpose: The importance of building airtightness is increased as the demand and expectation of building energy efficiency is growing. Previous research only focused on airtightness of building openings only to improve building airtightness. However, the analysis of difference of airtightness performance according to the characteristic of building structure has not been performed. Therefore, this study analyzed the difference of airtightness performance according to building structural characteristics in a number of ways. Method: Airtightness that are classified as rigid-frame type or wall type are measured and analyzed the difference of airtightness performance between rigid frame type apartments and wall type apartments. This study calculated the heating energy demand and quantitatively analysis using ISO 13790. Futhermore, this study compared research trend of domestic airtightness performance with airtightness standards of the developed countries based on the field measurement. Result: Airtight performance of wall type is better than rigid frame type in terms of energy saving. The difference of heating energy demand between wall type and rigid frame type was $8.14kWh/m^2yr$.

열해석을 이용한 가스 실린더 캐비닛의 내화성능 최적설계 (Optimum Design on Fire Resistance of Gas Cylinder Cabinets using Thermal Analysis)

  • 남민서;김지유;김의수
    • 한국가스학회지
    • /
    • 제26권1호
    • /
    • pp.34-40
    • /
    • 2022
  • 특정 고압가스 등을 사용하기 위해 배관과 안전장치 등이 일체로 구성된 가스 실린더 캐비닛은 화재 발생 시 고온의 열로 인한 급격한 압력상승으로 실린더 폭발 및 파편 비산 등의 위험성을 가지고 있다. 이러한 위험성은 용기 내부에 충전된 가스의 유출을 초래하여 중독, 질식 등의 2차 피해를 발생시킬 가능성이 크므로 내부 용기로 인한 피해를 줄이기 위해서는 가스 실린더 캐비닛의 내화성능 확보가 매우 중요하다. 국외의 경우 가스 실린더 캐비닛이 화염에 노출되는 상황에서 일정 시간동안 내부의 실린더를 보호할 수 있도록 미국 NFPA code, 유럽 EN-14470-2 등에서 가스 실린더 캐비닛 내화시험 기준을 규정하고 있다. 하지만 국내의 경우 내압성능과 기밀성능 기준만 명시되어 있고, 그 대상은 배관계로 한정되어 있으며 국외보다 가스 실린더 캐비닛의 내화성능을 위한 연구 및 규정이 미흡한 실정이다. 이에 본 연구에서는 국내 가스 실린더 캐비닛의 내화성능 기준 확립을 위해 유한요소해석 프로그램인 ANSYS를 이용하여 열해석을 수행함으로써 화재 발생 시 구조, 재질 측면에서의 최적 조건을 도출하고자 한다.

천장형 시스템 에어컨의 토출방향 변화에 따른 실내 열쾌적성 평가 (Evaluation of Indoor Thermal Comfort for Ceiling Type System Air-Conditioner with Various Discharge Angles)

  • 이진형;김유재;최원석;박성관;윤백;김윤제
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1180-1185
    • /
    • 2006
  • Modern people spend most of time at indoor space, such as office or classroom. Especially, occupants are exposed to the airtight indoor air quality (IAQ) for a long time, At present, many studies on the air-conditioning systems are more focused on the individual thermal comfort than the thermal efficiency due to increase of the concern of health. There are several factors which are influenced thermal comfort, such as temperature, humidity, convection and air movement, etc. Also, the individual factor, such as age, gender, Physical constitution and habit, should be considered. The 4-way cassette type air conditioner is known to bring out better performance about thermal comfort than the traditional one. This study is performed on the higher ceiling environment than the common buildings or classrooms. Also, this study analyzed on the Indoor thermal comfort by diffusing direction of 4-way cassette air conditioner with various discharge angles, $45^{\circ},\;50^{\circ},\;55^{\circ}$ and $60^{\circ}$. Using a commercial code, FLUENT, three-dimensional transient air thermal flow fields are calculated with appropriate wall boundary conditions and standard $k-{\epsilon}$ turbulence model. Results of velocity and temperature distributions are graphically depicted with various discharge angles.

  • PDF

시험공간에 대한 냉방부하 실증실험 및 계산 (Verification Experiment and Calculation of Cooling Load for a Test Space)

  • 유호선;현석균;김용식;홍희기
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.641-651
    • /
    • 2003
  • In order to assess the reliability of a building energy simulation program (TRNSYS) from the standpoint of user, a set of verification experiment and calculation of cooling load for a test space is carried out. This work is a complement of the previous study that dealt with heating load for the same space. The test space is kept airtight to eliminate the source of uncertainties in modeling. A window-mounted, on/off controlled air-conditioner is used for cooling, whose performance has been established a priori. The calculation encompasses two models for evaluating cooling load in TRNSYS: energy rate control and temperature level control. Comparison of the total cooling loads obtained from different sets of experimental data enables to validate the measurements. The experimental result shows that the latent load is fairly large even in the absence of apparent air change in the space, which needs to be clarified. Each of hourly and daily accumulated sensible loads is compared between the experiment and two calculation models. Despite an inconsistency associated with solar irradiation, both of the models agree favorably with the experiment within a tolerance, illustrating their capability of properly predicting space thermal loads.