• Title/Summary/Keyword: airborne dust

Search Result 137, Processing Time 0.031 seconds

Particulate-Matter Related Respiratory Diseases

  • Kyung, Sun Young;Jeong, Sung Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.83 no.2
    • /
    • pp.116-121
    • /
    • 2020
  • Particulate matter (PM) is suspended dust that has a diameter of <10 ㎛ and can be inhaled by humans and deposited in the lungs, particularly the alveoli. Recent studies have shown that PM has an adverse effect on respiratory diseases. The aim of this article is to review respiratory diseases associated with PM. According to existing studies, PM is associated with chronic obstructive pulmonary disease, bronchial asthma, and several other respiratory diseases and increases the mortality rates of these diseases. Moreover, increased exposure in the high concentration of atmospheric PM is associated with the development of lung cancer. The most simple and common way to protect an individual from airborne PM is to wear a face mask that filters out PM. In areas of high concentration PM, it is recommended to wear a face mask to minimize the exposure to PM. However, the use of N95 or KF94 masks can interfere with respiration in patients with chronic respiratory diseases who exhibit low pulmonary function, leading to an increased risk of respiratory failure. Conclusionally, reduction of the total amount of PM is considered to be important factor and strengthening the national warning notification system to vulnerable patients and proper early management of exacerbated patients will be needed in the future.

Performance assessment of HEPA filter to reduce internal dose against radioactive aerosol in nuclear decommissioning

  • Hee Kwon Ku;Min-Ho Lee;Hyunjin Boo;Geun-Dong Song;Deokhee Lee;Kaphyun Yoo;Byung Gi Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1830-1837
    • /
    • 2023
  • The thermal cutting of contaminated or activated metals during decommissioning nuclear power plants inevitably results in the release of radioactive aerosol. Since radioactive aerosols are pernicious particles that contribute to the internal dose of workers, air conditioning units with a HEPA filter are used to remove radioactive aerosols. However, a HEPA filter cannot be used permanently. This study evaluates the efficiency and lifetime of filters in actual metal cutting condition using a plasma arc cutter and a high-resolution aerosol detector. The number concentration and size distribution of aerosols from 6 nm to 10 ㎛ were measured on both the upstream and downstream sides of the filter. The total aerosol removal efficiency of HEPA filter satisfies the standard of removing at least 99.97% of 0.3 ㎛ airborne particles, even if the pressure drop increases due to dust feeding load. The pressure drop and particle size removal efficiency at 0.3 ㎛ of the HEPA filter were found to increase with repeated cutting experiments. By contrast, the efficiency of used HEPA filter reduced in removing nano-sized aerosols by up to 79.26%. Altogether, these results can be used to determine the performance guidance and replacement frequency of HEPA filters used in nuclear power plants.

The distribution characteristics of airborne lead in the major monitoring locations in Korea (국내 주요지역의 대기 중 납성분에 대한 분포특성 조사)

  • Kim, K.H.;Jung, S.Y.
    • Journal of Environmental Policy
    • /
    • v.4 no.2
    • /
    • pp.83-101
    • /
    • 2005
  • Because of its strong potential for health hazards, the concentration levels of airborne lead (Pb) have been circumscribed by environmental laws in many countries. In this study, we made a comparative study on the environmental behavior of Pb for the acquisition of its distribution characteristics using data sets collected from major cities in Korea for a period of 6 years (1998 through 2003). According to this study, Pb concentration decreased slowly in most industrialized cities of Koreathroughout the whole study. period. In contrast, such temporal signals were not evident in data sets collected from residential, commercial, and grassland areas. Although seasonal patterns generally exhibited the occurrences of high Pb concentration during the spring, results appear to reflect the influence of Asian Dust (AD) in the springtime. The results of our study clearly indicate that Pb distribution is strongly influencedby source types in relation to their land use patterns. Comparison of our Pb data sets with that of other countries indicates that Pb concentration levels obtained from relatively cleaner districts of Korea are still significantly higher than other countries. The results of this analysis generally indicate that Pb concentrations in most areas are affected by the type and strength of man-made activities. Considering that most areas are affected by a variety of pollutants, continuous efforts are needed to control Pb concentrations in the atmosphere.

  • PDF

A Study on Estimating Air Pullution in the Port of Incheon (인천항의 대기오염물질 배출량 산정 연구)

  • Lee, Jeong-Uk;Lee, Hyang-Suk
    • Journal of Korea Port Economic Association
    • /
    • v.37 no.1
    • /
    • pp.143-157
    • /
    • 2021
  • International organizations such as the World Health Organization, the Organization for Economic Development and Cooperation, and major developed countries recognize the seriousness of air pollution. International organizations such as the International Maritime Organization have also implemented various regulations to reduce air pollution from ships. In line with this international trend, the government has also enacted a special law on improving air quality in port areas, and is making efforts to reduce air pollution caused by ports. The purpose of the Special Act is to implement comprehensive policies to improve air quality in port areas. This study sought to identify the emissions of each source of air pollutants originating from the port and prepare basic data on setting the policy priorities. To this end, the analysis was conducted in six categories: ships, vehicles, loading and unloading equipment, railways, unloading/wild ash dust, road ash dust, and the methodology presented by the European Environment Agency(EEA) and the United States Environmental Protection Agency(EPA). The pollutants subject to analysis were analyzed for carbon monoxide(CO), nitrogen oxides (NOX), sulfur oxides(SOX), total airborne materials(TSP), particulate matter(PM10, PM2.5), and ammonia(NH3). The analysis showed a total of 7,122 tons of emissions. By substance, NOX accounted for the largest portion of 5,084 tons, followed by CO (984 tons), SOX (530 tons), and TSP (335 tons). By source of emissions, ships accounted for the largest portion with 4,107 tons, followed by vehicles with 2,622 tons, showing high emissions. This proved to be the main cause of port air pollution, with 57.6% and 36.8% of total emissions, respectively, suggesting the need for countermeasures against these sources.

Seasonal and Locational Concentrations of Particulate Air Pollutants in Indoor Air of Public Facilities in Taegu Area (대구지역 공중위생법 규제대상시설의 실내공기중 입자상 오염물질의 계절별 및 지점별 농도분포 특성)

  • 백성옥;송희봉
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.3
    • /
    • pp.163-176
    • /
    • 1998
  • In this study, airborne particle samples were obtained to determine the concentrations of particulate air pollutants in indoor and outdoor air of public facilities in Taegu area. Total of 12 public facilities, regulated by the Public Sanitary Law, were selected as sampling sites, which include three underground arcades, one railway and two bus terminals, three general hospitals, and three department stores. In each place, sampling was carried out seasonally during the period of October 1994 to July 1995, and four samples per each site per season were collected both indoors and outdoors simultaneously. After determination of suspended particulate matter (SPM) mass concentrations, the particle samples were divided into two parts for subsequent chemical analysis: one for the analysis of trace elements and the other for water soluble ions. Seasonal levels of SPM appeared to be the highest in spring and the lowest in summer both indoors and outdoors, while locational variations of highest in statioyterminals, and lowest in department stores . SPM concentrations indoors and outdoors did not show any significant differences each other in most places . However, there were significant correlations between indoor and outdoor levels of SPM and other chemical species . These results indicates that indoor SPM levels are likely to be significantly affected by outdoor sources in many places. The most significant source of SPM was estimated to be the resuspension of soil/road dust both indoors and outdoors . The concentrations of toxic heavy metals (Pb, Cd, Cr, Cu) in underground arcades appeared to be very much lower than the established air quality guidelines for underground environments. In addition, it is likely that micro-environmental parameters such as temperature, humidity, and air velocity, play a less significant role than outdoor air quality as a factor affecting the levels of particulate pollutants in indoor environments of public facilities in Taegu area.

  • PDF

Sensitization rates of airborne pollen and mold in children

  • Park, So-Hyun;Lim, Dae-Hyun;Son, Byong-Kwan;Kim, Jeong-Hee;Song, Young-Eun;Oh, In-Bo;Kim, Yang-Ho;Lee, Keun-Hwa;Kim, Su-Young;Hong, Sung-Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.9
    • /
    • pp.322-329
    • /
    • 2012
  • Purpose: Aeroallergens are important causative factors of allergic diseases. Previous studies on aeroallergen sensitization rates investigated patients groups that had visited pediatric allergy clinics. In contrast, we investigated sensitization rates in a general population group of elementary school to teenage students in Incheon, Jeju, and Ulsan. Methods: After obtaining parental consent, skin-prick tests were performed on 5,094 students between March and June 2010. Elementary school students were tested for 18 common aeroallergens, whereas middle and high school students were tested for 25 allergens. The 25 allergens included Dermatophagoides pteronyssinus, Dermatophagoides farinae, pollen (birch, alder, oak, Japanese cedar, pine, willow, elm, maple, Bermuda grass, timothy grass, rye grass, orchard grass, meadow grass, vernal grass, mugwort, Japanese hop, fat hen, ragweed, and plantain), and mold (Penicillatum, Aspergillus, Cladosporium, and Alternaria). Results: The sensitization rates in descending order were 25.79% (D. pteronyssinus ), 18.66% (D. farinae ), 6.20% (mugwort), and 4.07% (willow) in Incheon; 33.35% (D. pteronyssinus ), 24.78% (D. farinae), 15.36% (Japanese cedar), and 7.33% (Alternaria) in Jeju; and 32.79% (D. pteronyssinus), 30.27% (D. farinae), 10.13% (alder), and 8.68% (birch) in Ulsan. The dust mite allergen showed the highest sensitization rate among the 3 regions. The sensitization rate of tree pollen was the highest in Ulsan, whereas that of Alternaria was the highest in Jeju. The ragweed sensitization rates were 0.99% in Incheon, 1.07% in Jeju, and 0.81% in Ulsan. Conclusion: The differences in sensitization rates were because of different regional environmental conditions and distinct surrounding biological species. Hence, subsequent nationwide studies are required.

Evaluation on the Expected Purification Efficiency of Air Ion and Analysis on the Generated Amount of Negative Air Ions by Plants for the Purification of Particulate Matter in Air (지표대기 미세먼지 정화를 위한 식물체 음이온 발생량 분석 및 음이온의 미세먼지 기대정화지수 평가)

  • Oh, Deuk-Kyun;Ju, Jin-Hee
    • Journal of Environmental Science International
    • /
    • v.29 no.6
    • /
    • pp.623-631
    • /
    • 2020
  • This study analyzes the effect of negative air ions on the concentration of airborne particulate matter and evaluates the expected purification efficiency of open spaces for particulate matter by investigating the amount of negative air ions generated by plants. This study establishes a negative air ion generation treatment environment, plant environment, and control environment to measure the purification efficiency of particulate matter under the conditions of each, analyzing the expected purification efficiency by designing a particulate matter purification model. Results show that the amount of generated negative air ion according to environment was negative air ion generation treatment environment > plant environment > control environment; this order also applies to the particulate matter purification efficiency. Moreover, it took 65 min for the negative ion generation treatment environment, 90 min for the plant environment, and 240 min for the control environment to reach the standard expected purification efficiency of particulate matter concentration of 960 mg/㎥ for PM10. For PM2.5, with the designated maximum concentration of 700 mg/㎥, it took 60 min for the negative ion generation treatment environment, 80 min for the plant environment, and more than 240 min for the control environment. Based on these results, the expected purification efficiency compared to the control environment was quadrupled in the negative ion generation treatment environment and tripled in the plant environment on average.

Exposure Assessment of PM10 in Expressway Toll Booths (고속도로 톨게이트 부스 내 공기 중 PM10의 노출평가)

  • Nam, Mi Ran;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.2
    • /
    • pp.151-157
    • /
    • 2018
  • Objectives: This study was conducted in order to evaluate $PM_{10}$ concentrations at eight highway tollgate booths from July to September 2017. Methods: A total of 16 samples were collected from eight toll booths. Each $PM_{10}$ sample was collected using a 37 mm PTFE filter attached to a Personal Environment Monitor. Results: The geometric mean concentrations of $PM_{10}$ in the toll booths was $83.51{\mu}g/m^3$. The mean $PM_{10}$ concentrations measured on freight roadways were much higher than those of measured on general roadways($102.46{\mu}g/m^3$ and $68.05{\mu}g/m^3$, respectively). $PM_{10}$ was revealed to be higher in the morning($105.59{\mu}g/m^3$) than at dawn or in the afternoon($71.26{\mu}g/m^3$ and $61.22{\mu}g/m^3$, respectively). The mean $PM_{10}$ concentration in toll booths ventilated through an air conditioner was higher than that for those using a window or no ventilation. The rate of exceeding the Ministry of Environment Maintenance Limit($200{\mu}g/m^3$) was 6.25%, and the rate of exceeding the Ministry of Labor Recommended Limit($150{\mu}g/m^3$) was 12.5%. Conclusions: In order to protect the health of toll booth workers exposed to airborne dust, it is necessary to check the exposure level from indoor air quality on a regular basis and to manage it appropriately according to the results.

Assessment of Occupational Health Risks for Maintenance Work in Fabrication Facilities: Brief Review and Recommendations

  • Dong-Uk Park;Kyung Ehi Zoh;Eun Kyo Jeong;Dong-Hee Koh;Kyong-Hui Lee;Naroo Lee;Kwonchul Ha
    • Safety and Health at Work
    • /
    • v.15 no.1
    • /
    • pp.87-95
    • /
    • 2024
  • Background: This study focuses on assessing occupational risk for the health hazards encountered during maintenance works (MW) in semiconductor fabrication (FAB) facilities. Objectives: The objectives of this study include: 1) identifying the primary health hazards during MW in semiconductor FAB facilities; 2) reviewing the methods used in evaluating the likelihood and severity of health hazards through occupational health risk assessment (OHRA); and 3) suggesting variables for the categorization of likelihood of exposures to health hazards and the severity of health effects associated with MW in FAB facilities. Methods: A literature review was undertaken on OHRA methodology and health hazards resulting from MW in FAB facilities. Based on this review, approaches for categorizing the exposure to health hazards and the severity of health effects related to MW were recommended. Results: Maintenance workers in FAB facilities face exposure to hazards such as debris, machinery entanglement, and airborne particles laden with various chemical components. The level of engineering and administrative control measures is suggested to assess the likelihood of simultaneous chemical and dust exposure. Qualitative key factors for mixed exposure estimation during MW include the presence of safe operational protocols, the use of air-jet machines, the presence and effectiveness of local exhaust ventilation system, chamber post-purge and cooling, and proper respirator use. Using the risk (R) and hazard (H) codes of the Globally Harmonized System alongside carcinogenic, mutagenic, or reprotoxic classifications aid in categorizing health effect severity for OHRA. Conclusion: Further research is needed to apply our proposed variables in OHRA for MW in FAB facilities and subsequently validate the findings.

Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(I) - Effect zone of environmental pneumoconiosis and fugitive dust - (대구 안심연료단지 환경오염물질 노출 평가(I) - 환경성 진폐증 및 비산먼지 영향권역 -)

  • Jung, Jong-Hyeon;Oh, In-Bo;Phee, Young-Gyu;Nam, Mi-Ran;Hwang, Mi-Kyoung;Bang, Jin-Hee;Jeon, Soo-Bin;Lee, Sang-sup;Yu, Seung-do;KimS, Byung-Seok;Yoo, Seok-Ju;Lee, Kwan;Lim, Hyun-Sul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.366-379
    • /
    • 2015
  • Objectives: The objective of this study is to assess airborne particulate matter(PM) pollution and its effect on health of residents living near Ansim Briquette Fuel Complex in Daegu metropolitan region. Methods: The California Puff(CALPUFF) dispersion model, version 5.8, which can estimate the dispersion direction and range of airborn $PM_{10}$ was used to determine the possible areas affected by $PM_{10}$ pollutants emitted from Ansim briquette fuel complex. The CALPUFF modeling with 200 m grid-cell resolution was performed based on $PM_{10}$ emissions estimated from the amount of coal consumption in the fuel complex for four months in 2012. The Weather Research and Forecasting(WRF) fields were processed using CALMET to produce CALPUFF-ready meteorological inputs. Also, the distance from Ansim Briquette Fuel Complex to the residence of each environmental pneumoconiosis patient was analyzed. In addition, the affecting region of the pollutants emitted from briquette factories in Ansim Briquette Fuel Complex was determined. Results: CALPUFF modeling results showed that the highest concentrations of $PM_{10}$ were found near around the fuel complex. The modeled $PM_{10}$ distributions were characterized by significant decreases in concentration with distance from the complex. Seasonally, the highest concentration of $45{\mu}g/m^3$ was calculated in October which was mostly due to the distinct variation of amount of emission. Additional modeling with the maximum $PM_{10}$ emission of about 88 tons per year in 1986 showed that the highest concentration in October was nearly increased by 8 times than the concentration modeled with emission of 2010. As a result of medical examination and interviews for the residents in Ansim Briquette Fuel Complex and its surroundings, 8 environmental pneumoconiosis patients were found. These patients do not have occupational exposure and history. These patients have lived 0.3~1.1 km area in Ansim Briquette Fuel Complex and its surroundings. Conclusions: Airborne particles emitted from Ansim Briquette Fuel Complex can contribute to significant increase in $PM_{10}$ concentration in residential areas near around the complex. Especially, the residents near fuel complex may exposed to the pollutants emitted from the factories in Ansim Briquette Fuel Complex.