• Title/Summary/Keyword: air-floating

Search Result 176, Processing Time 0.028 seconds

Wafer Motion Control of a Clean Tube System (클린튜브 시스템의 웨이퍼 정지 제어)

  • 신동헌;최철환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.459-462
    • /
    • 2003
  • This paper presents a force model of the clean tube system, which was developed as a means for transferring the air-floated wafers inside the closed tube filled with the super clean air. The recovering force from the holes for floating wafers is modeled as a linear spring and thus the wafer motion is modeled as a mass-spring-damper system. The propelling forces are modeled as linear along with the wafer location. The paper also proposes the control method to emit and stop a wafer at the center of a control unit. It shows the minimum value of the propelling force to leave from the control unit. In order to stop the wafer, it utilizes the exact time when a wafer arrives at the position to activate the propelling force. Experiments with the clean tube system built for 12 inch wafer shows the validity of the proposed model and the algorithm.

  • PDF

Motion analysis of a VLCO for wave power generation (파력발전용 가변수주진동장치의 운동해석)

  • Lee, Seung-Chul;Goo, Ja-Sam
    • Journal of Power System Engineering
    • /
    • v.18 no.3
    • /
    • pp.36-41
    • /
    • 2014
  • The structure of a variable liquid column oscillator(a VLCO) is analogous to that of the tuned liquid column damper used to suppress oscillatory motion in large structures like tall buildings and cargo ships. The VLCO is a system absorbing high kinetic energy of accelerated motions of the multiple floating bodies in the effect of air springs occurred by installation of inner air chambers. Thus, VLCO can improve the efficiency of energy than wave energy converters of the activating object type made in Pelamis Company. In this research, the experiment was performed in two models of same draft. The one is that weights were filled, and the other is that water was filled. The numerical results were estimated by assuming that do not exist internal flow, and the results were compared with the results of experiments.

Studies on the Compressed Air Submersible Fish Cage System ( I ) -Dynamic Characteristic of the Submersible Fish Cage- (압축공기식 부침가두리에 관한 연구 ( I ) - 부침가두리의 동적특성 -)

  • Kim, Jae-Oh;Shin, Hyeong-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.2
    • /
    • pp.117-124
    • /
    • 1996
  • The real size submersible fish cage($L{\times}B{\times}D$, $3{\times}3{\times}6$m)system consists of the compressed air equipment was made in order to control efficiently in case of heavy weather or environmental pollution such as red tide, and then carried out experiment on the submersible functions and safety for that cage at Koje inland sea in 14th June, 1995. The authors could confirm that the submersible cage was very stabilized it's submersible functions and safety when the cage was floating and sinking at sea.

  • PDF

Structural Aspects of the Reduced Free-floating Hydrophyte, Spirodela polyrhiza (부유부엽성 개구리밥 식물체의 구조분화 연구)

  • Kim, Kyoung-Ae;Kim, In-Sun
    • Applied Microscopy
    • /
    • v.30 no.2
    • /
    • pp.233-240
    • /
    • 2000
  • Aspects of structural differentiation of the free -floating hydrophyte, Spirodela polyrhira, has been investigated. The hydrophyte exhibited highly reduced structures having only fronds, connective stalks, and roots as a mature plant. The fronds were major photosynthetic and vegetatively reproducing organ during the growth. Daughter fronds which developed early in the mother frond were also chlorenchymatous, but they remained within foliage sheaths of the mother frond before separation from connecting stalks. Although the stalks and roots originated from the same meristematic region of the frond, they exhibited the distinct polarity showing former lateral growth and latter axial growth. Air chambers were formed only in the fronds and roots. Cellular components were scattered throughout the diffuse cytoplasm in most of the actively growing stalk cells. Root cells protected by the root cap demonstrated relatively complex organization, showing dense cytoplasm with Golgi, rER, mitochondria, and chloroplasts in the cortical cells. Cells in the root cap were highly vacuolated within the peripheral cytoplasm. Such reduction and differentiation of the plant body in Spirodela polyrhiza most effectively contributes to the better adaptation of smaller plants to superficial aquatic environments, while also enabling the rapid growth.

  • PDF

Microstructure of the (Nd/Y)-Ba-Cu-O superconductors by floating zone melt growth process (부유대역용융성장법을 이용한 (Nd/Y)-Ba-Cu-O계 초전도체의 미세구조)

  • 김소정
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.2
    • /
    • pp.83-87
    • /
    • 2003
  • $(Nd/Y)_{1.8}Ba_{}2.4Cu_{3.4}O_{7-x}$high $T_c$ superconductor was directionally grown by floating Bone melt growth process with a large temperature gradient in air. Cylindrical green rods of (Nd/Y)1.8 oxides were fabricated by cold isostatic pressing (CIP) method using rubber mold. Microstructures were observed by SEM and TEM and superconducting properties were measured by a SQUID magnetometer. Nonsuperconducting $(Nd/Y)_2BaCuO_5$ inclusions were uniformly distributed within the superconducting $(Nd/Y)Ba_2Cu_3O_x$ matrix. The directionally melt-textured (Nd/Y) 1.8 superconductor showed an onset Tc $\geq$ 90 K and a sharp superconducting transition.

Design of gas suspension absorber to improve desulfurization efficiency

  • Hwang, Woohyeon;Lee, Kyung-Ok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.2
    • /
    • pp.189-195
    • /
    • 2020
  • In this study, the inlet duct and guide vane of the gas floating absorption tower were redesigned to improve the desulfurization efficiency so that the exhaust gas can be uniformly introduced into the absorption tower. In order to reduce the sulfur oxide pollutants among the main sources of air pollutants in industrial boilers, the existing equipment is redesigned and solved. For this purpose, change the exhaust gas, the slurry and recycling the adsorbent to improve the removal efficiency of SOx component in the exhaust gas inside the gas floating absorption tower so as to uniformly contact. And the initial design value and CFD value for the pressure loss from the boiler outlet to the gas floating absorption tower outlet are verified. Also, the velocity distribution of the exhaust gas, the concentration distribution of the recycled adsorbent, the liquid slurry behavior, and the pressure loss were compared. The results confirmed that the desulfurization efficiency was improved because the pressure loss from the boiler outlet to the absorption tower outlet was reduced and the deflection of the exhaust gas was minimized.

Reduction of the Offensive Odor from Confectionery Wastewater Plant (제과공장의 폐수처리장에서 발생하는 악취 저감)

  • 김영식;손병현;조상원;정종현
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.62-69
    • /
    • 1998
  • It has been studied that the measurement of odor component emission at confectionery manufacture. The objects of this study were to investigate reduction of offensive odor. The survey effects of odorous materials are presented as follows. The countermeasure of operating process is to minimize sludge sediment in each unit facility. Especially, in summer, we have to clean the sludge frequently, because anaerobic decomposing is likely to occur easily. The sludge or scum from sedimentation tank pond, and floating tank should be treated quickly. We should avoid overloading operation. In the case of overloading, dissolved oxygen should be increased, the quality of wastewater input should be decreased. When dried cakes from condense tank or floating tank are left in treatment plant, we should cover, to prevent diffusion of smell with masking materials. The seasonal condition of operating should be fixed and the kind of coagulants should be changed because the wastewater in each season have different loading rates and organic materials. Odorous materials are very sensitive to the seasonal temperature variation. Especially, when the amount of rainfall is small and the high temperature of maintenance in long periods, air diffusion rate is large, so odorous materials can make great effect on surroundings comparision with other periods. To reduce odorous gas, as short term method, we had better take ceramic addition method. Especially, in summer we should take ceramic addition method. Also, as long term method, the size of wastewater treatment facility is the most important in the normal operating of wastewater treatment facility. But wastewater treatment facilities in this factory are too old, treatment process is old fashion, and the size is too small. So, large wastewater quantity to treat in summer. As results, the expansion of wastewater treatment facility and the process of improvement are required. Restriction level of odor was exceed. As it is overloaded in summer, the basis cause of odor is that the size of wastewater treatment facility is small. The prediction of air quality equilibrium density variation show that the odorous materials from working place are Amine materials whose smell strength is about 2.5(a little strong degree). We can suppose that in summer is sensitive to temperature variation, smell strength is larger as to reduce the origin of odor. We must expand wastewater treatment facility and improve the process A.S.A.P.

  • PDF

Microbial Contamination of Seasoned and Dried Squid Dosidicus gigas during Processing (조미오징어(Dosidicus gigas)의 가공 공정 중 미생물 오염도 및 오염원에 관한 연구)

  • Choi, Kyoo-Duck;Park, Uk-Yeon;Shin, Il-Shik
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.45 no.5
    • /
    • pp.445-453
    • /
    • 2012
  • This study examined microbial contamination during seasoned and dried squid Dosidicus gigas processing, including the apparatus, machines, and employee's gloves at each step in processing at two companies. The numbers of bacteria floating in air in each processing area were also examined. The numbers of Staphylococcus aureus (3.6-6.0 log CFU/g) and Escherichia coli (1.3-1.4 log MPN/100 g) in domestic and imported daruma (a semi-processed product of seasoned and dried squid) at companies A and B exceeded the regulatory limits of the Food Sanitary Law of Korea (S. aureus, ${\leq}2.0$ log CFU/g; E. coli, negative). S. aureus in both daruma was reduced to below the detection limit or 3.6 log CFU/g after the roasting step, but increased again to 3.3 and 5.5 log CFU/g after the mechanical tearing step at companies A and B, respectively. E. coli showed similar tendencies at both companies. The surfaces of the apparatus, machines, and employee's gloves that contacted daruma were also contaminated with S. aureus (1.0-5.5 log CFU/$m^2$) and E. coli (negative-to 3.5 log MPN/$m^2$). The numbers of bacteria floating in air were high (1.7-5.1 log CFU/$m^3$) at both companies. These results suggest that sanitation standard operating procedures (SSOP) must be developed to control of microbial cintamination in seasoned and dried squid.

Fabrication of porous titanium oxide-manganese oxide ceramics with enhanced anti-static and mechanical properties (우수한 대전방지 및 기계적 성질을 가지는 다공성 산화티탄-산화망간 세라믹스 제조)

  • Yu, Dongsu;Hwang, Kwang-Taek;Kim, Jong-Young;Jung, Jong-Yeol;Baik, Seung-Woo;Shim, Wooyoung
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.28 no.6
    • /
    • pp.263-270
    • /
    • 2018
  • Recently, porous ceramic materials with anti-static performance are urgently needed for semiconductor and OLED/LCD display manufacturing industry. In this work, we fabricated porous titanium manganese oxide ceramics having the surface resistivity of $10^8-10^{10}$ ohm and enhanced mechanical strength by partial sintering method using nanosized titanium oxide. By addition of nano-sized titanium oxide in the matrix, neck formation between grains was strengthened, which remarkably increased flexural strength up to 170 MPa (@porosity: 15 %), 110 MPa (@porosity: 31 %), compared to 80 MPa (@porosity: 26 %) for pristine titanium manganese oxide ceramics. We evaluated the performances of our ceramics as air-floating module for OLED flexible display manufacturing devices.

Evaluation of the Location Efficiency of Fine Dust Shelters Considering Vulnerable Population in Seoul (취약계층을 고려한 미세먼지 쉼터 입지 효율성 평가)

  • Lim, Jae Kwon;Lee, Hye Kyung
    • Journal of KIBIM
    • /
    • v.12 no.4
    • /
    • pp.104-115
    • /
    • 2022
  • Fine Dust in Korea has been classified as a social disaster since 2019 due to continuous increase in concentration of Particulate Matter 10(PM 10) and PM 2.5. The fine dust issue has negative physical and mental impacts, especially on vulnerable population including children and the elderly. Seoul metropolitan government have installed fine dust shelters since 2019. However, there is a lack of research that evaluates spatiotemporal distribution of these facilities. Therefore, the first aim of this study is to find the relationship between PM levels and dust scattering construction sites, or air pollutant emission sites through in depth spatial analyses. The second purpose is to analyze the spatial distribution of PM shelters in Seoul, and to evaluate the location efficiency of them. Kernel density, krigging, and network analyses were conducted, and floating population was considered instead of census data for this research. The reults of network analysis based on the road system showed that Yangcheon-gu, Songpa-gu, Seongbuk-gu, and Dobong-gu were found to need additional fine dust shelters. Also, the results from analyzing the floating population that includes children and the elderly showed that Songpa-gu, Seodaemun-gu, Gangdong-gu, Seocho-gu, and Dongdaemun-gu need more placements of find dust shelters. The results of this study are expected to provide implications for urban planners to enhance find dust shelter placement in urban areas, and vulnerable population issues would be considered in many ways.