• 제목/요약/키워드: air conditioning

검색결과 8,502건 처리시간 0.029초

Orthodontic bracket bonding to glazed full-contour zirconia

  • Kwak, Ji-Young;Jung, Hyo-Kyung;Choi, Il-Kyung;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • 제41권2호
    • /
    • pp.106-113
    • /
    • 2016
  • Objectives: This study evaluated the effects of different surface conditioning methods on the bond strength of orthodontic brackets to glazed full-zirconia surfaces. Materials and Methods: Glazed zirconia (except for the control, Zirkonzahn Prettau) disc surfaces were pre-treated: PO (control), polishing; BR, bur roughening; PP, cleaning with a prophy cup and pumice; HF, hydrofluoric acid etching; AA, air abrasion with aluminum oxide; CJ, CoJet-Sand. The surfaces were examined using profilometry, scanning electron microscopy, and electron dispersive spectroscopy. A zirconia primer (Z-Prime Plus, Z) or a silane primer (Monobond-S, S) was then applied to the surfaces, yielding 7 groups (PO-Z, BR-Z, PP-S, HF-S, AA-S, AA-Z, and CJ-S). Metal bracket-bonded specimens were stored in water for 24 hr at $37^{\circ}C$, and thermocycled for 1,000 cycles. Their bond strengths were measured using the wire loop method (n = 10). Results: Except for BR, the surface pre-treatments failed to expose the zirconia substructure. A significant difference in bond strengths was found between AA-Z ($4.60{\pm}1.08MPa$) and all other groups ($13.38{\pm}2.57-15.78{\pm}2.39MPa$, p < 0.05). For AA-Z, most of the adhesive remained on the bracket. Conclusions: For bracket bonding to glazed zirconia, a simple application of silane to the cleaned surface is recommended. A zirconia primer should be used only when the zirconia substructure is definitely exposed.

액-가스 열교환기를 적용한 천연가스 액화공정 성능 특성 (Performance Characteristics of Natural Gas Liquefaction Process using Liquid-gas Heat Exchanger)

  • 윤정인;유선일;오승택;이호생;이상규;최건형
    • 한국가스학회지
    • /
    • 제13권6호
    • /
    • pp.44-48
    • /
    • 2009
  • 본 연구에서는 천연가스 액화 플랜트 산업에서의 핵심 기술인 액화공정 개발을 위해 두 가지 2단 압축 방식의 액화 사이클의 성능을 시뮬레이션 하였다. Process1은 케스케이드 액화공정을 기초로 하여 프로판, 에틸렌, 메탄 사이클 모두 인터쿨러가 적용된 것이다. Process 2는 위의 공정에 메탄과 에틸렌 사이클 사이에 액-가스 열교환기를 적용하였고, Process 3은 위의 공정에 에틸렌과 프로판 사이클 사이에 액-가스 열교환기를 추가로 적용하였으며, 인터쿨러를 적용한 케스케이드 공정과 성능을 비교하였다. Process 2의 COP는 Process 1보다 14.0%정도 높게 나타났고, LNG 단위 생산량 당 소비 동력은 11.5% 정도 낮게 나타났다.

  • PDF

해양플랜트 HVAC 시스템용 플레이트·쉘 타입 증발기에 관한 연구 (A Study on Plate & Shell type Evaporator in HVAC System for Offshore Plant)

  • 박재홍
    • 한국가스학회지
    • /
    • 제24권1호
    • /
    • pp.33-40
    • /
    • 2020
  • 해양플랜트용 HVAC(Heating Ventilation and Air-Conditioning) 시스템의 컨덴싱 유닛(condensing unit)의 경우, DX(Direct Expansion) 코일보다는 온도 안정성이 뛰어난 칠러 시스템(chiller system)을 주로 사용하고 있다. 칠러시스템의 구성품 중 대형 냉매압축기와 전자식 팽창밸브 등은 대부분 수입되고 있다. 이에 칠러 시스템의 크기는 국내에서 제작되는 열교환기(증발기, 응축기)에 의해 좌우된다. 현재 갈수록 심화되고 있는 사용공간의 제한으로 인해 선주사 및 조선소에서는 장비 크기를 컴팩트하게 해줄 것을 메이커에 지속적으로 요구하고 있다. 이에 본 논문에서는 해양플랜트에서 만액식(flooded) 칠러 시스템의 증발기로 주로 사용되고 있는 쉘-튜브형 열교환기를 컴팩트한 플레이트-쉘 열교환기로 대체하기 위한 주요개발과정을 소개하고, 이와 함께 개발된 플레이트-쉘 열교환기를 실제 증발기로 적용한 만액식 칠러 시스템을 제작하여 그 성능을 실험적으로 평가하였으며 그 결과를 제공하고자 한다.

종합병원 진단검사의학과 검사실의 시설 설비 현황 조사 - 550 병상 이상 종합병원을 중심으로 (A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on more than 550 bed sized hospitals)

  • 김영애;송상훈
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제26권1호
    • /
    • pp.73-84
    • /
    • 2020
  • Purpose: Though Korean healthcare services have been upgraded, infection and fire had been broken out in general hospitals. And higher concerns about quality assessment made it to clinical laboratory design guideline studies. So, this study investigates the facilities, equipment and personnel of laboratory medicine focusing on more than five hundred fifty bed hospital, and contributes to make guidelines for safety and efficiency in lab. Methods: Questionnaires to supervisor technologist and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 16 answers have been analysed statistically by MS Excel program. Results: Most of the sample tests such as hematology, clinical chemistry, immunology, transfusion, urinalysis, microbiology and molecular diagnosis are performed by more than 80% in large sized general hospital laboratory. In the test methods, automatic analyzers are used up to 80%, total laboratory automation up to 43% in clinical chemistry and immunology, and manual tests in all sorts of the test. There are placed in single lab or two and three labs above the ground, which are all in semi-open lab. There is some correlation with the number of specimens and the number of lab people depending on the number of hospital beds. Laboratory environment shows that work distance is good, but evacuation path width, visibility, separation of staff area from automatic analyzer, and equipment installations are needed to have more spaces and gears. Most of the infection controls are equipped with mechanical ventilation, air-conditioning, washbasin and wastewater separation, BSC installation and negative pressure lab room. Implications: Although the laboratory space area is calculated considering the number of hospital beds, type of tests and number of staff, hospital's expertise and the samples numbers per year should be taken into account in the planning of the hospital.

공동체 활동을 기반으로 한 스마트빌리지 기술개발 수요분석 (Demand Analysis of Technology Development for Smart Village based on Community Activities)

  • 박소연;조혜진;정남수
    • 농촌계획
    • /
    • 제26권2호
    • /
    • pp.117-126
    • /
    • 2020
  • In this study, demands of smart technology development were analyzed for rural village communities. Questionnaire items were derived by grasping the current status of information and communication technology. 49 villages in 8 regions were selected and surveys and statistical analysis were conducted. The main results of the study are as follows. First, 92% of community leaders use smartphones, search for information (38%), communicate with the Internet (36%) using smartphones, use KakaoTalk (31%), and Facebook (24%). Second, in the rural and urban exchange activities, promote support information service (51%) and promote method suggestion service (48.5%) showed that the demand for services in promote field was high. It is linked to the creation of economic opportunities. Third, in the income and production activities, demand for distribution services technology (39.3%) was high in the field of production and distribution, and cold chains that help maintain freshness until food, such as meat, fish, and vegetables are delivered to consumers when agricultural products are distributed. The constant temperature control system needs to be actively introduced. Fourth, autonomy activities showed the highest demand for air conditioning and control systems (34.2%) of community building, and the lowest demand for electronic voting (9.4%) and videoconferencing (9.4%) services. Lastly, in the general activity area of the community, the demand for technology of emergency services (37.1%) and health self-diagnosis service (35.4%), which are technologies in the welfare sector, ranked first and second respectively.

고력볼트 시공환경에 따른 토크계수와 체결축력에 관한 실험적 연구 (Experimental Study on the Torque Coefficient and Clamping Force of High Strength Bolts Subjected to Environmental Parameters)

  • 이현주;나환선;김강석;김진호;김진만
    • 한국강구조학회 논문집
    • /
    • 제20권1호
    • /
    • pp.43-53
    • /
    • 2008
  • 현재 국내에서 현장 체결공법으로 채용하고 있는 토크관리법은 토크계수를 근거로 해서 간접적으로 도입축력을 제어하는 방법이기 때문에 현장에서의 토크계수 관리가 상당히 중요하다. 따라서 본 연구에서는 현장 시공시 볼트보관방법 및 현장관리에서 일반적으로 발생할 수 있는 주요 환경 요인 중 수분 침투, 녹 발생, 외기노출, 와셔의 오용 등 다양한 실험변수로 계획하여 토크계수의 변화에 따른 도입축력의 차이를 확인하기 위하여 실험을 수행했다. 실험에 사용된 볼트는 육각 고력볼트, TS 고력볼트, 아연피막처리 육각 고력볼트, ASTM A490 고력볼트로서 4종류로 구분하여 수행되었고, 각 볼트별로 시공환경에 따른 체결특성을 비교 분석하였다.

화학축냉용 무기염들의 수화반응 및 열 및 물질전달 향상방안 (Study of Hydration Reaction Characteristics of Inorganic Salts for Chemical Cold Storage and Method of Enhancement of Heat and Mass Transfer)

  • 김상욱;한종훈;황용준;이건홍
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 춘계 학술발표회 논문집
    • /
    • pp.185-191
    • /
    • 1999
  • An air-conditioning system based on the chemical heat storage principle was considered. $H_2O$ was chosen as the reaction gas and the working fluid as well. Na$_2$S, CaCl$_2$, MnCl$_2$, BaCl$_2$, MgCl$_2$, Fe$_2$(SO$_4$)$_3$ and MnSO$_4$ were tested as the solid reactants by using Cahn pressure balance. Na$_2$S was superior to other salts in respect of high capability of absorption of water gas, 5 moles of $H_2O$ per unit mole of Na$_2$S, and adequate temperature of adsorption, $65^{\circ}C$ at 7torr, and of desorption, 13$0^{\circ}C$ at 76torr. Clausius-Clapeyron diagram of Na$_2$S was obtained via adsorption experiments at several vapor pressures of water gas. To enhance heat and mass transfer characteristics, usually below 1W/m K, of the reactor bed of general adsorption systems, expanded graphite block was adapted as the support of Na$_2$S salt. Expanded graphite blocks had thermal conductivity values of 20~80W/mK with respect to 100~400kg/㎥ of block bulk density. Permeability values of expanded graphite blocks were 10$^{-13}$ ~ 10$^{-14}$ $m^2$ with respect to 100~300kg/㎥ of block bulk density showing highly decreasing values of permeability, below 10$^{-l4}$$m^2$, in the range of above 150kg/㎥ of block bulk density.y.

  • PDF

흡입관 열교환기를 이용한 탄화수소계 냉매용 냉동사이클의 성능 분석 (Performance Analysis of Refrigeration Cycle of Hydrocarbon Refrigerant using Suction-Line Heat Exchanger)

  • 구학근
    • 한국산학기술학회논문지
    • /
    • 제10권9호
    • /
    • pp.2195-2201
    • /
    • 2009
  • 본 논문은 R290, R600a, R1270과 같은 탄화수소계 냉매를 사용하는 냉동사이클의 효율에 대한 흡입관 열교환기의 영향을 고려하였다. 이러한 흡입관 열교환기는 냉동시스템의 성능을 향상시킬 수도 있지만, 성능을 저하시킬 수도 있다. 본 논문에서는 흡입관 열교환기를 가진 냉동사이클의 성능 특성을 파악하기 위해서 정상상태의 수학적 모델을 사용하였다. 그리고 탄화수소계 냉매유량, 흡입관 열교환기의 내관 직경, 길이, 유용도 등과 같은 운전조건의 영향을 분석하였다. 연구결과는 흡입관 열교환기의 내관 직경, 길이, 유용도, 탄화수소계 냉매의 질량유량은 냉동사이클의 상대냉동능력지수, 냉동능력, 압축일량에 영향을 미치는 것을 알 수 있었다. 따라서 이러한 영향을 상세히 파악하여, 흡입관 열교환기를 설치한 탄화수소계 냉매용 증기압축식 냉동사이클을 설계할 필요가 있다.

전동식 Scroll Compressor의 Scroll 열변형 해석 (Coupled Thermal-Stress Analysis of Scrolls in Automotive Scroll Compressor)

  • 이형욱;김정배;이근안;이종섭;이영선
    • 융복합기술연구소 논문집
    • /
    • 제2권1호
    • /
    • pp.38-42
    • /
    • 2012
  • A scroll compressor used in the air conditioning in automobile consists of the fixed scroll and the orbiting scroll. Temperature gradient in the scroll compressor during the operation induces the thermal expansion of two scrolls. Therefore, the gap between scrolls in the initial stage is regarded as an important variable in structural design of the scroll compressor. The coupled thermal-stress analysis was carried out for the scrolls of a scroll compressor. The temperatures of major points of two scrolls in the steady states were referred by the literature of C. Lin. The sequentially coupled thermal-stress analysis is utilized to the heat transfer analysis and the thermal expansion analysis. In the thermal expansion analysis, the contact analysis was considered between the fixed and the orbiting scrolls in order to obtain the penetration distance and the contact pressure between two scrolls. The range of deformation was from 44 to $76{\mu}m$ according to the height of the scroll. The maximum penetration distance of $60{\mu}m$ occurred at the top surface of the fixed scroll in the center of the scroll parts.

  • PDF

Urban Forest Monitoring in Korea since 1991: Case Study on Daegu Metropolitan City

  • Kwon, Jino;Cho, HyunJe;Choi, MyoungSnb;Park, Chan-Ryul;Sung, Joo-Han;Cho, Jae-Hyoung;Kim, Sunhee;Park, Jonggyun;Oh, Jeong-Hak
    • 한국산림과학회지
    • /
    • 제95권5호
    • /
    • pp.591-594
    • /
    • 2006
  • To have better urban forests in future we are focusing on two major issues like other countries. How we could have more urban forest-quantitative approach-against the expanding of urbanization, and how we could produce better urban forest-qualitative approach-to give a chance in contact with better nature for urban people. Prime surveys on urban forests have been carried out in 6 major cities since 1991, and the city of Daegu which is located on the east southern area of Korea have been case studied for qualitative approaches during last 3 years. Major species of the remnant forests were Pinus densiflora, Pinus rigida, Pinus thunbergii and Robinia pseudoacacia. Approximately 20% of the surveyed forests were lost their structure as forests caused by illegal farming, facilities and as the bare ground by excessive visitors. Generally speaking the condition of forests for biotope was very poor in overall. From two years data of monitoring of birds, we found that wooded parkways and woodland squares had more species than street tree areas. Nests were found mainly on the branch of Zelkova serrata, Pinus densiflora and Quercus myrsinaefolia. The size of urban forests mainly determined the species richness of birds. According to the oxygen output and carbon input by photosynthesis measurement, the capability was in order of Platanus occidentalis, Zelkova serrata and Ginko biloba. Air conditioning effects of trees through transpiration measurement was found and the quality of forests also related to the reducing of urban heat-island.