• 제목/요약/키워드: air conditioning

검색결과 8,504건 처리시간 0.029초

데시칸트 공조시장 및 전망 (Desiccant Air Conditioning System market and Prospect)

  • 박승태;정광섭;김영일;박종일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.230-235
    • /
    • 2009
  • The Desiccant air conditioning system has been designed as the industrial dehumidifier under the leadership of developed countries, considering CFC problems in 1990, indoor air quality(IAQ) and outdoor air intake rates. This could make the technical differences between them and us. Nowadays, domestic technology has been developed in some parts but there still remain many challenges to be managed. In this study, these tasks would be handled according to the desiccant air conditioning system market and prospects.

  • PDF

외기 전용 공조기의 동특성 시뮬레이션 (Dynamic Simulation of a Dedicated Outdoor Air-conditioning System)

  • 김정민;김영일;정광섭;박승태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.322-327
    • /
    • 2007
  • Dedicated outdoor air-conditioning(DOA) system that utilizes pre-cooling and desiccant dehumidification can be superior to conventional cooling and reheating system with respect to energy consumption and indoor thermal comfort. In this work, simulation has been conducted to study various factors that affect the performance of DOA. Dynamic simulation shows the transient variation of temperature and humidity as the on/off control logic is imposed. Exit humidity of process air and flow rate are varied to study the effect on exit temperature of process air, dehumidification quantity, required regeneration temperature and exit humidity of regeneration air. For an outdoor air condition of $28.5^{\circ}C$ temperature, 16 g/kg humidity ratio and 2000 cmh flow rate, the dehumidification efficiency is increased by 4.6% as the flow rate is doubled.

  • PDF

지역별 프리쿨링 시스템의 에너지 절감 분석 (Analysis of Energy Reduction of Free Cooling System with Regions of South Korea)

  • 윤정인;손창효;최광환;백승문;허정호;김영민
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.82-88
    • /
    • 2014
  • Using low outdoor temperature, free cooling system is used in a data center or industrial air-conditioning for energy saving. Because use of IT equipment has increased in some office building recently, there is a growing trend towards using free cooing system. Free cooling system performance is influenced by outdoor temperature. Therefore the performance is different with regions. In this study, performance characteristic of free cooling system is analysed and energy reduction is compared with some regions. Selected regions are 4 cities; including Ulsan analyzed in preceding research, Seoul, ChunCheon and Daejeon. The Aspentech software HYSYS 8.0v was used to conduct the analysis of free cooling system based on temperature per hour of 4 cities in 2013, respectively. The main result is following as. Free cooing system in this study has energy saving effect when outdoor temperature below $7^{\circ}C$. Becuase temperature of Chuncheon is relatively low, using free cooling system can conserve most air-conditioning energy. Energy reduction amount of Seoul is 11%, Chuncheon is 17.5%, Deajeon is 15%, Ulsan is 14%. In case of large scale of air-conditioning, it is reasonable to use free cooling system although the system is used in Seoul.

환기시스템 설치 강의실에서 시스템에어컨과 팬코일유닛의 열쾌적성 및 환기성능 평가 (Evaluation of Thermal Comfort and Ventilation Performance in the Lecture Room with Ventilation System and Two Different Air-conditioning Systems: System Air-conditioner or Fan Coil Unit)

  • 한창우;노광철;오명도
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.1079-1087
    • /
    • 2005
  • In this paper, thermal comfort and ventilation performance characteristics in the lecture room with the ventilation system and two different air-conditioning systems, system air-conditioner or fan coil unit, were evaluated by experimental and numerical methods. We compared the measured data with the computational results of the predicted mean vote and carbon dioxide concentration. Additionally the ventilation effectiveness was calculated numerically. From a viewpoint of the uniformity of PMVs in the lecture room, the thermal distribution performance of the system air-conditioner was more effective than the fan coil unit. Carbon dioxide concentration and ventilation effectiveness were barely affected by the type of the air-conditioning system.

자동차 에어컨 쾌적제어 알고리즘 개발을 위한 운전자 온열감성 평가 : 제 2보-운전자의 생리반응 (Comfort Control Algorithm Development of Car Air Conditioner using Thermal Comfort Evaluation of The Driver : Part II-Physiological Response of Driver)

  • 김민수;김동규;박종일;금종수
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.217-223
    • /
    • 2016
  • In this study, we investigated the operating method of a driver for an air conditioning system according to the temperature difference between the indoor and outdoor environments of a car parked outside during the summer. Researchers of this study suggest the comfort mode of a car air conditioner to improve the thermal comfort of the driver, thereby maintaining longer comfort. This study separately, analyzed temperatures on a cloudy day and sunny day. The results showed the car indoor heat environment and physiological results (EEG, ECG) of the subject. It showed a difference of the car indoor heat environment by weather with the difference also appearing in the physiological response of the subject. In conclusion, in this paper, on the basis of the physiological response of a subject, a comfortable algorithm of automobile air conditioner is being suggested.

슬래브축열의 최적제어방책에 관한 연구 -평가함수의 선택이 결과에 미치는 영향- (A Study on the Optimal Control Strategy of Air-Conditioning System with Slab Thermal Storage - Results Influenced by the Choice of a Criterion Function -)

  • 정재훈;신영기
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.896-905
    • /
    • 2006
  • An optimal control of an air-conditioning system with slab thermal storage is investigated by making use of the Maximum Principle. An optimal heat input to a plenum chamber and an air-conditioned room is determined by minimizing a criterion function which is given as integral sum of two terms. The first term is the square of the deviation in the room air temperature from the set-point value, and the second is the absolute value of the heat input. The result indicates that it tries to keep a room air temperature in set-point value by heating as much as possible at the time of a setup of a room air temperature or just before that, in order to avoid a heat loss arising at the time of the non-air conditioning. The result is compared with that of the case when the square of the heat input is used as a criterion.

빙축열을 이용한 저온공조시스템 운전 특성 연구 (Study on operation characteristics of the cold air distribution systems with an ice storage tank)

  • 염한길;박병규;고득용
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.301-312
    • /
    • 1999
  • Experiments were carried out to evaluate performance of the cold air distribution systems with an ice storage tank in test room. Cold air distribution systems provide primary air for comfort conditioning or process cooling at coil discharge temperatures$4^{\circ}C$ to$11^{\circ}C$. The application of a cold air distribution system allows for the downsizing of air distribution equipment and central plant equipment when ice storage tank is used. The benefit of a cold air distribution system include a decrease in the floor-to-floor height, increase floor space, reduced building capital costs, reduced energy use and demand. The use of cold air distribution can result in the most cost effective system and is currently being implemented world wise as the new standard in air conditioning systems. In this study, the cold air distribution system is compared with the general ice storage system. Under the same cooling load conditions, experimental results show that the supply air volume of cold air distribution system decrease 38%, and decrease 45% flow rate of brine for the general ice storage system.

  • PDF