• Title/Summary/Keyword: air cleaners

Search Result 56, Processing Time 0.028 seconds

Analysis on Particle Cleaning Capacity of Indoor Air Cleaners for Different Flow Rates Considering Energy Consumption (에너지소비를 고려한 실내공기청정기의 풍량별 입자 청정화능력 분석)

  • Han, Bangwoo;Kang, Ji-Su;Kim, Hak-Joon;Kim, Yong-Jin;Won, Hyosig
    • Particle and aerosol research
    • /
    • v.9 no.3
    • /
    • pp.139-147
    • /
    • 2013
  • The performances of indoor air cleaners including particle cleaning capacity and collection efficiency are usually tested at the condition of the maximum air flow rate of the air cleaners. However, the power consumption of the air cleaners is highly dependent on the air flow rate of the individual air cleaners. Therefore, there seems to be an optimized air flow rate for the air cleaning capacity considering power consumption. In this study, clean air delivery rate(or standard useful area as suggested room size) and power consumption have been investigated for different maximum air flow rates of 15 air cleaners and then compared those for different air flow rate modes of the individual 5 air cleaners selected from the 15 cleaners. For the maximum air flow rate conditions of 15 air cleansers, the power consumption per unit area was less related to the maximum air flow rate. However, for the different air flow rate modes of the selected 5 air cleaners, the lower power consumption per unit area was corresponding to the lower air flow rate mode of the individual air cleaners. When considering the operation time to the desired particle concentrations, there was an optimized one in the medium air flow rate modes for the individual air cleaners. Therefore, not only the maximum air flow rate but also lower air flow rates of individual air cleaners should be considered for estimating air cleaning capacity based on energy consumption per unit area.

Comparative Efficiency Evaluation of Air Cleaners for Improving Indoor Air Quality (실내용 공기청정기 유형별 실내환경개선 성능에 대한 비교평가)

  • Na, Kyung-Ho;Son, Jin-Seok;Sung, Kijune;Jang, Young-Kee
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.3
    • /
    • pp.109-115
    • /
    • 2005
  • This study was conducted to evaluate the efficiency of indoor air cleaners and to inform how to select them correctly to the users. The efficiencies of removing suspended bacteria per hour were $64.3{\pm}13.1%$ for filter, wet, and complex type, respectively, which showed the complex type was the most efficient. The removal efficiencies of formaldehyde (HCHO) after two hours operation of air cleaners showed 88.3% and 81.1% for filter and wet type, respectively. The efficiency of complex type, with removal rate of 55.5~58.4%, was decreased after 30 minutes operation. Therefore, it is recommended to perform over 60 minutes when doing air cleaner certification test for HCHO removal efficiency. Generally, air cleaners having low wind volume showed higher efficiency. All tested air cleaners had no potential for removing of volatile organic compounds (VOCs), which is toxic substances, and it is desirable to develop a device which can control these substances. The results also confirmed that there was no ozone production from all tested air cleaners. And it is recommended to ventilate for 20 minutes every four hours to maintain 50% ventilation status.

Noise Characteristics of Air Cleaners and Humidifiers (공기청정기와 가습기의 소음특성)

  • Kim, Yong Hee;Park, Ji Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.1
    • /
    • pp.20-26
    • /
    • 2016
  • This study investigated noise characteristics of air cleaners and humidifiers in terms of frequency domains and measurement directions. Noise levels of 31 air cleaners and 36 humidifiers were measured in an anechoic chamber according to the related group standards. As for air cleaners, 5 receiving points of 1 m off from front, rear, left, right and top surfaces of the product were considered. In case of humidifiers, 4 receiving points without the rear position were considered in the same manner as air cleaners. In each case, A-weighted equivalent continuous sound level was measured three times for 1 min. As a results, most of the measured air cleaners and humidifiers showed the highest noise levels at top directions due to the air ventilating location. In case of air cleaners, averaged noise levels of top and rear positions were 49.9 and 48.2 dB(A), respectively, whereas averaged noise level of other positions was all 45.2 dB(A). In case of humidifiers, averaged noise level of top position was 44.1 dB(A) whereas averaged noise levels of other positions were 38.7 to 39.1 dB(A). In addition, high frequency content of 1 kHz and 3.15 kHz to 4 kHz for air cleaners and middle frequency content of 500 Hz to 1.6 kHz for humidifiers showed significant contribution to determination of overall noise levels with correlation coefficient of 0.9 and above.

Empirical study on evaluation of performance and filter replacement cycle of air cleaners installed in subway station (지하역사 공기청정기 성능평가 및 필터 유지보수 실증 연구)

  • Kwang Chul Noh;Sang Woo Kim;Cheong Ha Hwang
    • Particle and aerosol research
    • /
    • v.20 no.2
    • /
    • pp.69-77
    • /
    • 2024
  • In this study, the performance of air cleaners installed in subway stations was evaluated using field test method and chamber test method in accordance with the standard for air cleaner. Also, the air filter maintenance period was examined by the performance reduction of air cleaners with respect to the air filter usage period. From the field tests, the clean air delivery rate (CADR) of air cleaners with filter in use was about 85% on average compared to the ones with new filter. The main factor of CADR reduction was not the decrease of filter efficiency but the decrease of airflow rate. The chamber test results shows that the CADR of air cleaners decreased with the usage time, but the proper filter replacement can make the CADR keep about 95% of the certified CADR. The expected filter replacement cycle measured by the field test method was calculated to be approximately 3.35 months (100 days). However, the replacement cycle was a large difference between 1.2 and 6.6 months with the different stations. Therefore, the replacement cycle should be individually investigated for each station. The use of air cleaners must be effective in reducing fine dust in subway stations. For more effective air quality management in subway stations, additional researches is necessary to define the appropriate capacity of HVAC system and air cleaner, and related maintenance for each station.

A Study on the Performance for Heavy-duty Diesel Engine with Intake Air Filter (대형디젤기관에서 자동차 흡기 에어필터 장착에 따른 성능에 관한 연구)

  • Rha, Wan-Yong;Oh, Sang-Ki
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.114-117
    • /
    • 2005
  • Air cleaners in all of the automotive engines have been used for decades. In the early 1920's the oil bath type was the popular shape of air cleaners. The air cleaners of the oil wetted bath type were introduced in 1940's. The shape of the dry pleated paper type media was introduced in the 1950's. This trend still continues with new and innovative media being introduced. Engine air cleaners should have effectively removed and reduced harmful contaminants being ingested into engines. This studies show that both, the ingested contaminant size and concentration need to be controlled. This paper com pare and analyze the characteristics over the economics, engine performances and reduction of noises of power-plus air filters with wet paper which were sticked to heavy duty diesel engine.

Analysis of performance test results of CA-certified air cleaners from 2003 to 2015 (2003년부터 2015년까지 CA 인증 공기청정기의 성능 시험 결과 분석)

  • Kim, Hak-Joon;Hong, Kee-Jung;Woo, Chang Gyu;Han, Bangwoo;Kim, Yong-Jin
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.17-23
    • /
    • 2017
  • In this study, the test results obtained from the performance tests for CA (Korea Association of Cleaning Air) certificated air cleaners which had been commercially available in Korea from 2003 to 2015 were analyzed. Among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level, noise level and CADR were correlated with flow rates. Collection and odor removal efficiencies were 20% higher than the limit of the CA certification. The ozone emissions from the air cleaners were negligible because all the air cleaners were equipped with only HEPA filters, not electrostatic precipitation method which produces ozone.

Removal of Serratia marcescens Aerosols Using an Electrostatic Precipitator Air-Cleaner

  • Ko, Gwang-Pyo;Burge, Harriet
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.10
    • /
    • pp.1622-1628
    • /
    • 2007
  • We characterized the efficacy of an electrostatic precipitator (ESP) air-cleaner in reducing the concentration of Serratia marcescens in an enclosed space. We used an experimental room ($4.5{\times}3{\times}2.9\;m$) in which electrostatic air-cleaners were located. Two air-cleaners enhanced the equivalent ventilation rates in the chamber by about 3.3 air changes per hour (ACH) over the 2 ACH provided by the mechanical ventilation system. Natural die-off of the organisms provided an additional equivalent of 3 ACH, so that the total ventilation rate with the ESP air-ccleaners was 8.3 ACH. We also examined whether the ESP air-cleaners altered the deposition of Serratia marcescens aerosols on the experimental room surfaces. We did not find any significant differences in the number of colony forming units recovered from surfaces with and without the air-cleaners. We installed UV lights inside the ESPs and determined if UV light, in addition to electrical fields, increased the efficacy of the ESPs. The presence of UV light inside the ESP reduced S. marcescens aerosols by approximately 2 ACH. Finally, a box model indicates that the efficiency of the air-cleaner increases for both biological and nonbiological particles at ventilation rates of 0.2-1, which are typical for residential settings.

Analysis of CA Certification Performance Test Results and Improvement of CA Test Method for a Better Differentiation of Gas Removal Performances for Room Air Cleaners (공기청정기 CA 규격성능시험 결과 분석 및 가스시험 변별력 향상 방안연구)

  • Kim, Hak-Joon;Han, Bangwoo;Kim, Yong-Jin;Cha, Sung-Il
    • Particle and aerosol research
    • /
    • v.7 no.3
    • /
    • pp.87-97
    • /
    • 2011
  • In this study, we organized the test results obtained from the performance tests for the CA certificated air cleaners which had been commercially available in Korea since 2003, and analyzed the correlation among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level etc. The noise level of 267 air cleaners were increased as concentrated at the 45, 50, 55 dB, which are the required noise level for CA certification according to flow rate, and ozone emissions from the CA air cleaners were significantly lower than the requirement limit, 50 ppb for 24 hour operation. The average particle collection efficiency and odor removal efficiency were 89.3 and 80.8%, approximately 20% higher than the requirement of CA certification, regardless of flow rates. The particle removal performance of an air cleaner was clearly discriminated by its CADR, and the CADR was obtained with a simple calculation: 0.79 x flow rate. The low differentiation of gas removal performance of air cleaners by the current CA gas test method was improved by 3.2, 751.3, 13.4 times for ammonia, acetic acid, respectively, by adopting the CADR concept and the real time measurement method, FTIR, for gas removal performance test.

Field tests of indoor air cleaners for removal of PM2.5 and PM10 in elementary school's classrooms in Seoul, Korea (서울 초등학교 교실의 PM2.5 및 PM10 제거를 위한 학교용 공기청정기 실증)

  • Han, Bangwoo;Hong, Keejung;Shin, Dongho;Kim, Hakjoon;Kim, Yongjin;Kim, Sangbok;Kim, Sangwoo;Hwang, Cheongha;Noh, Kwangchul
    • Particle and aerosol research
    • /
    • v.15 no.2
    • /
    • pp.79-90
    • /
    • 2019
  • It is important to control fine particles in children care centers, elementary schools, elderly care facilities and so on where vulnerable children and the aged stay during most of their time. This study has investigated $PM_{2.5}$ and $PM_{10}$ concentrations in two classrooms equipped with an air cleaner and two air cleaners, respectively and they were compared to those in a classroom without an air cleaner as well as those outdoors. Eight air cleaners which have various clean air delivery rates (CADRs) between 9.9 and $21.3m^3/min$ were tested in classrooms in two elementary schools in Seoul. Average $PM_{2.5}$ and $PM_{10}$ were $7.3{\pm}0.7$ and $45.5{\pm}4.1{\mu}g/m^3$ in classrooms equipped with an air cleaner and $4.2{\pm}0.6$ and $24.6{\pm}2.5{\mu}g/m^3$ in classrooms with two air cleaners, whereas they were $22.1{\pm}2.6$ and $109.1{\pm}9.6{\mu}g/m^3$ in classrooms without an air cleaner and $36.9{\pm}5.1$ and $74.1{\pm}10.6{\mu}g/m^3$ outdoors, respectively. $PM_{2.5}$ in classrooms could be reduced effectively by using an air cleaner or two air cleaners, because $PM_{2.5}$ was mainly infiltrated from outdoors, however $PM_{10}$ could not because $PM_{10}$ was mainly caused indoors by students' activities. Air cleaners were more effective for removal of $PM_{2.5}$ and $PM_{10}$ in classrooms with a high airtightness than those in classrooms with a relatively low one. Average $CO_2$ in classrooms was about 1500 to 2000 ppm for class hours dependent on the student number per a classroom, which was about 1.5 to 2 times higher than the standard, regardless of the use of air cleaner.