• Title/Summary/Keyword: air cavity

Search Result 501, Processing Time 0.03 seconds

Antibacterial Activity of $NANOVER^{TM}$ Against Oral Malodor Generating Microorganisms 1. The Effect of Nanosilver on Growth of Oral Malodor Generating Microorganisms (구취유발세균에 대한 $NANOVER^{TM}$의 항균효과 검사 1. Nanosilver가 구취 세균의 증식에 미치는 영향)

  • Jung, Young-Hee;Mo, Hye-Won;Jeong, Ji-Suk;Choi, Kyung-Ho;Choi, Jae-Kap;Hur, Yun-Kyung;Lee, Sang-Heun
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.1
    • /
    • pp.39-48
    • /
    • 2009
  • Recently there is much interest in the antibacterial activity of nano-sized silver particle (nanosilver) since silver is known to be safe and effective as disinfectant for a long time. Oral malodor is considered to originate in the oral cavity primarily as a result of production of malodorous compounds by oral bacteria. Major compounds responsible for oral malodor are volatile sulfur compounds, which is thought to be generated by the G(-) anaerobic bacteria found normally in the oral cavity, especially on the dorsum of the tongue. The purposes of this study were to investigate the effect of nanosilver on growth of oral malodor generating microorganisms, including Fusobacterium nucleatum, Prevotella melaninogenica, Klebsiella pneumonia, and to determine the optimal culture condition of them. The results were as follows: 1. The optimal culture condition for P. melaninogenica was vacuum culture using desiccator after evacuation of air by vacuum pump in chopped beef meat media. 2. The growth of K. pneumonia was temporarily inhibited by nanosilver (5 ppm and 10 ppm). 3. The morphological alteration and cell damage caused by nanosilver were observed in K. pneumonia.

A case of prolapse of the laryngeal ventricle (후두실 탈출증 1례)

  • 권우영;손학선;백문찬;김종애;조진규
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.7.1-7
    • /
    • 1977
  • According to Bryce and Cranston, prolapse of the laryngeal ventricle is a protrusion of the ventricular mucosa into the laryngeal cavity from inflammatory hyperplasia or edema. This 53 year old female patient was admitted to our hospital March 11, 1977 with the chief complaints of dyspnea and hoarseness. On admission, evaluation of the larynx revealed smooth surfaced round pink-reddish mass protruding bilaterally beneath the false cord. The airway was almost completely obstructed by the tumor mass, but neither ulceration nor infiltration was seen, also no lymphnode was palpable in the neck. Tracheotomy was performed for the relief of dyspnea and biopsy was done endoscopically. Histologic study showed chronic inflammation. On April 2, 1977 laryngofissure was performed under general anesthesia. Laryngeal examination revealed smooth surfaced, plate like, pinkreddish mass protruding bilaterally from both laryngeal ventricles into the laryngeal cavity and extending the whole length of the ventricle antero-posteriorly and touching each other. Biopsy was taken of the mass and the result was non-specific inflammatory hyperplasia of the larynx. Postoperatively, the air way is completely clear of obstruction but mild hoarseness still remains. No recurrent mass is visible in the larynx. In view of the symptoms, operative findings and histological findings, this case is diagnosed as "Prolapse of the laryngeal ventricle". The prolapse of the laryngeal ventricle is a very rare lesion and is reported with review of the literature.

  • PDF

THE EFFECT OF LOW-VISCOSITY RESIN SYSTEMS OM MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATIONS (Low-viscosity Resin Sysem이 복합레진 수복물의 변연누출에 미치는 영향)

  • Yang, Jeong-Suk;Kim, Mun-Hyoun;Her, Sun;Kim, Jae-Gon;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.2
    • /
    • pp.460-474
    • /
    • 1997
  • The purpose of this study was to evaluate and compare the effectiveness of various low-viscosity resin systems used as rebonding agents to prevent microleakage at the margins of class I composite resin restorations. Seventy sound human premolars were selected for experiment. Class I cavities were prepared and each cavity was conditioned with a 37% phosphoric acid for 15 sec, rinsed with water for 15 sec, and dried with compressed air. Bonding agent(Scotchbond Multipurpose, 3M Co.) was applied and a hybrid composite resin (Z-100, 3M Co.) was placed using an incremental technic. The excess cured composite resin was carefully removed with Sof-Lex discs(3M Co.) to expose the original margins of the cavity. The following seven groups were established : group 1 was not rebonded and used as control group ; group 2 was rebonded with a Scotchbond Multipurpose(3M Co.) and finished ; group 3 was rebonded with a Fortify(BISCO) and finished ; group 4 was rebonded with a Concise white sealant(3M Co.) and finished ; group 5 was rebonded with a Concise white sealant(3M Co.) and not finished ; group 6 was rebonded with a P&F sealant(BISCO) and finished; group 7 was rebonded with a P&F sealant(BISCO) and not finished. The specimens were then subjected to 500 thermocycles between 5 & 65 with a 10 see dwell time and immersed in 2% methylene blue dye solution for 24 hours and sectioned with low-speed diamond cutter into two part under water condition. The extent of microleakage at rebonded margins was evaluated microscopically and scored for dye penetration according to the following scale : 0=no dye penetration ; 1=dye penetration to half-way along axial wall between enamel surface and DEJ ; 2=dye penetration beyond halfway along axial wall between enamel surface and DEJ ; 3=dye penetration to the full depth of DEJ or beyond DEJ. Selected samples were prepared for SEM observation to determine the depth of penetration of the rebonding agent into the marginal interface. The obtained results were as follows: 1. In the group 2 and 3, which is rebonded with a Scotchbond Multipupose and Fortify, dye penetration score were decreased significantly than that of group 1 (P<0.05), but group 4 and 6 were not statistically different from group 1(P>0.05). 2. There were significant differences between group 4, 6 and group 5, 7 when compared by dye penetration score (P<0.05). 3. In the SEM observation, Scotchbond Multipurpose and Fortify were penetrated within $30-40{\mu}m$ depth of the outermost surface. However, both sealants were failed to penetrate into the debonded interface.

  • PDF

REAL-TIME MEASUREMENT OF DENTINAL TUBULAR FLUID FLOW DURING AND AFTER AMALGAM AND COMPOSITE RESTORATIONS (아말감과 복합레진의 수복 과정과 수복 후 발생하는 상아세관액 흐름의 실시간 측정)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lim, Bum-Sun;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.467-476
    • /
    • 2009
  • The aim of this study was to measure the dentinal tubular fluid flow (DFF) during and after amalgam and composite restorations. A newly designed fluid flow measurement instrument was made. A third molar cut at 3 mm apical from the CEJ was connected to the flow measuring device under a hydrostatic pressure of 15 $cmH_2O$. Class I cavity was prepared and restored with either amalgam (Copalite varnish and Bestaloy) or composite (Z-250 with ScotchBond MultiPurpose: MP, Single Bond 2: SB, Clearfil SE Bond: CE and Easy Bond: EB as bonding systems). The DFF was measured from the intact tooth state through restoration procedures to 30 minutes after restoration, and re-measured at 3 and 7days after restoration. Inward fluid flow (IF) during cavity preparation was followed by outward flow (OF) after preparation, In amalgam restoration, the OF changed to IF during amalgam filling and slight OF followed after finishing. In composite restoration, application CE and EB showed a continuous OF and air-dry increased rapidly the OF until light-curing, whereas in MP and SB, rinse and dry caused IF and OF, respectively. Application of hydrophobic bonding resin in MP and CE caused a decrease in flow rate or even slight IF. Light-curing of adhesive and composite showed an abrupt IF. There was no statistically significant difference in the reduction of DFF among the materials at 30 min. 3 and 7 days after restoration (p > 0.05).

A experimental Feasibility of Magnetic Resonance Based Monitoring Method for Underground Environment (지하 환경 감시를 위한 자기공명 기반 모니터링 방법의 타당성 연구)

  • Ryu, Dong-Woo;Lee, Ki-Song;Kim, Eun-Hee;Yum, Byung-Woo
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.596-608
    • /
    • 2018
  • As urban infrastructure is aging, the possibility of accidents due to the failures or breakdowns of infrastructure increases. Especially, aging underground infrastructures like sewer pipes, waterworks, and subway have a potential to cause an urban ground sink. Urban ground sink is defined just as a local and erratic collapse occurred by underground cavity due to soil erosion or soil loss, which is separated from a sinkhole in soluble bedrock such as limestone. The conventional measurements such as differential settlement gauge, inclinometer or earth pressure gauge have a shortcoming just to provide point measurements with short coverage. Therefore, these methods are not adequate for monitoring of an erratic subsidence caused by underground cavity due to soil erosion or soil loss which occurring at unspecified time and location. Therefore, an alternative technology is required to detect a change of underground physical condition in real time. In this study, the feasibility of a novel magnetic resonance based monitoring method is investigated through laboratory tests, where the changes of path loss (S21) were measured under various testing conditions: media including air, water, and soil, resonant frequency, impedance, and distances between transmitter (TX) and receiver (RX). Theoretically, the transfer characteristic of magnetic field is known to be independent of the density of the medium. However, the results of the test showed the meaningful differences in the path loss (S21) under the different conditions of medium. And it is found that the reflection coefficient showed the more distinct differences over the testing conditions than the path loss. In particular, input reflection coefficient (S11) is more distinguishable than output reflection coefficient (S22).

A Case of Massive Pulmonary Gangrene Complicated by Klebsiella Pneumonia (클렙시엘라 폐렴의 합병증으로 발생한 광범위 폐괴저)

  • Ha, Jun-Wook;Eom, Kwang-Seok;Jang, Seung Hun;Bahn, Joon-Woo;Kim, Dong-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.4
    • /
    • pp.381-385
    • /
    • 2004
  • Pulmonary gangrene is a rare and severe complication of bacterial pneumonia, where a pulmonary segment or lobe is sloughed due to parenchymal devitalization of the parenchyma, with secondary anaerobic infection and necrosis caused by pulmonary vascular thrombosis. Prior to the antibiotic era, massive pulmonary gangrene was potentially fatal. Herein, a case of pulmonary gangrene in a 67-year-old man is reported. He complained of fever, chills, dyspnea and purulent sputum of 5 days duration. The plain chest radiograph showed well-marginated right upper lobe consolidation, with bulging minor fissure, suggestive of a Klebsiella infection. A contrast CT scan demonstrated consolidation of the right upper lobe, with a central necrotizing portion. Klebsiella species was confirmed from both sputum and blood cultures. After appropriate antibiotics, the chest X-ray and CT scan 3 weeks later showed a large cavity with an air-fluid level, sloughing-off and extrusion of necrotic lung tissue, suggestive of pulmonary gangrene. Seven months later, the right gangrenous lung showed severe volume loss on a chest radiograph. The management of pulmonary gangrene has been somewhat controversial. Herein, it was managed without surgical drainage or resection. If the antibiotic therapy had failed, then a surgical approach would have been considered.

Clinical Experience of Spontaneous Hemopneumothorax (자연성 혈기흉의 임상적 경험)

  • Moon, Hyeon-Jong;Hwang, Seong-Wook
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.669-674
    • /
    • 2010
  • Background: Spontaneous hemopneumothorax is characterized by the accumulation of air and more than 400 mL of blood in pleural cavity without any apparent cause. It is a rare disease and can cause life-threatening situation. We analyzed clinical reviews of two medical centers to aid in optimal management. Material and Method: Retrospective review between March 2003 and August 2010 with 18 spontaneous hemopneumothorax patients was made. Result: These 18 patients were comprised of 15 male and 3 female with average 24.6 years (range 15~46 years). Almost patients (16) underwent a closed thoracostomy initially and 15 patients received video-assisted thoracic surgery (VATS). Mean postoperative chest tube removal was 2.9 days and one complication was post-removal pneumothorax. During the follow-up periods there were no other complications and recurrence. Conclusion: Proper initial diagnosis and management of spontaneous hemopneumothorax prevent significant hypovolemic shock. Video-assisted thoracic surgery should be considered an early surgical management in spontaneous hemopneumothorax. However conservative manage without bleb excision may be effective in selected patients.

Analysis of Microbial Contamination in Poultry Slaughtering Operations for the Application of HACCP (HACCP 적용을 위한 도계처리 공정내 미생물 오염의 분석)

  • 홍종해;권혁무;고주언
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.1
    • /
    • pp.45-50
    • /
    • 1996
  • The application of HACCP system, which was adopted by Codex Alimentarius Committee for the safe meat and poultry production, is one of the urgent task for competing in the world trade markets. But there have been no useful analytical studies to identify the causes of contamination in the poultry meat processing plants in Korea. This study was conducted to investigate the potential hazards during the operations by the microbiological examination for the poultry meat processing plant (20,000 birds capacity a day) located in Kangwon province. In spite of air contamination of work places, it may not directly affect the surface contamination of poultry meats. But the risk of Campylobacter jejuni/coli contamination was high. The number of total count was decreased about ten times, but remarkable changes of microbial contamination could not be recognized in each procedure during the operations. The washing water was already contaminated as much as $10^{3-6}CFU/ml$ in SPC before the operations. It means that to keep water tanks hygienic is a primary step to prevent the occurrences of microbial contamination. The overflow and recirculation of water in scalding, washing, and chilling was aslo an important factor for a hygienic control. Based on this study, the followings could be regarded as an important factors for hygenic control in the poultry slaughtering plants on a small scale. The temperature of water used for scalding should be constantly maintained on a required temperature, and the overflow rate of 1~1.5 liter per bird. The carcass surface and the body cavity should be washed thoroughly and the cross-contamination due to facilities, workers, and tools should be prevented. The chilling water sholud be maintained under 5$\circ$C of temperature with ice and overflow, and residual chlorine level of 50 ppm.

  • PDF

MARS Code Applicability Assessments for the HTGR RCCS (고온가스로 원자로공동냉각계통(RCCS)에 대한 MARS Code 적용성 평가)

  • Kang Doo-Hyuk;Kim Hyung-Seok;Chung Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.232-240
    • /
    • 2005
  • In this study, the IAEA Benchmark problems far HTR-10 and HTTR RCCS were assessed in order to assess the applicability of MARS code, a thermal-hydraulic safety analysis code developed for water reactors. The calculated results were compared with those or THERMIX, THANPACST2 code, and available experimental data. The calculated results showed generally good agreements with those obtained by the THERMIX code and THANPACST2 code. Deviations were analyzed to be originated from the simplification of complicated geometry and from the modeling capability of heat transfer characteristics in the HTGR components such as water cooler and air tooler. Especially, it was found that the radiation heat transfer in the reactor cavity played an important role in the after heat removal in the RCCS. Thus, it is concluded that MARS code can be successfully applied to the calculation of the RCCS cooling capability of the HTGR in this study.

DECOMPRESSION TREATMENT FOR ODONTOGENIC CYST IN MANDIBLE USING SPECIFIC DECOMPRESSION APPLIANCE : CASE REPORT (특별히 고안된 감압술 장치를 이용한 하악의 치성 낭종의 치료: 증례보고)

  • Kim, Kyoung-Soo;Kim, Jin-Cheol;Oh, Hae-Soo;Choi, Bin;Kil, Yong-Kab;Hong, Yong-Jae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.2
    • /
    • pp.182-186
    • /
    • 2007
  • A cyst is a pathologic lesion characterized by a cavity filled with fluid, celluar products, air, or a combination of these. Dentigerous cysts were formed around the crown of unerupted teeth. The reduced enamel epithelium persists around the crown after it has formed. Proliferation of the epithelium in a fluid-filled sac may be induced by osmotic pressure. In the first decade the most frequent location is the premolar site. In each subsequent decade the largest number of cysts are in the mandibular third molar site, with the second most frequent site being the maxillary canine. The treatment of odontogenic cyst can be mostly classified into three types of cyst enucleation, marsupialization and decompression. We should consider age of patient, anatomic structure, location and size for choosing a treatment method. Advantage of cyst enucleation is fast healing, but a injury of a surrounding structure is highly. Marsupialization is conservative treatment that can reduce the damage of a adjacent structure, but it is only limited at superficial lesion. Decompression also is conservative treatment, but it has the difficulty of the oral hygiene and the troublesome of the lavage. We present the possibility that reduces the defect of decompression and cures the lesion efficiently. We report a male patient with the dentigerous cyst developed at left mandibular third molar in this study. We used the decompression for a treatment and created special appliance to treat the lesion efficiently. We report a case of the cyst treatment that is association with efficiency of decompression appliance.