• Title/Summary/Keyword: air cavity

Search Result 501, Processing Time 0.026 seconds

Experimental study and numerical simulation on a dash system for noise reduction of a sedan vehicle (시험에 의한 대시시스템의 소음특성 규명 및 시뮬레이션 신뢰성 연구)

  • Yoo, Ji-Woo;Chae, Ki-Sang;Cho, Jin-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.667-671
    • /
    • 2012
  • Low frequency noises (up to about 200 Hz) mainly occur due to particular modes, resulting in booming noises, and in general the solutions may be found based on mode controls where conventional methods such as FEM can be used. However, at higher frequencies between 0.3~ 1 kHz, as the number of modes rapidly increase, radiation characteristics from structures, performances of damping sheets and sound packages may be more crucial rather than particular modes, and consequently the conventional FEM may be less practical in dealing with this kinds of structure-borne problems. In this context, so-called 'mid-frequency simulation model' based on FE-SEA hybrid method is studied and validated. Energy Transmission loss (i.e. air borne noise) is also studied. A dash panel component is chosen for this study, which is an important path that transfers both structure-borne and air borne energies into the cavity. Design modifications including structural modifications, attachment of damping sheets and application of different sound packages are taken into account and the corresponding noise characteristics are experimentally identified. It is found that the dash member behaves as a noise path. The damping sheet or sound packages have similar influences on both sound radiation and transmission loss. The comparison between experiments and simulations shows that this model could be used to predict the tendency of noise improvement.

  • PDF

A STUDY ON THE SHEAR BOND STRENGTH OF THE COMPOSITE RESIN TO GLASS IONOMER CEMENT ACCORDING TO SURFACE TREATMENT METHODS OF GLASS IONOMER CEMENT (글라스 아이오노머 시멘트의 표면처리방법에 따른 복합레진과의 전단결합강도에 관한 연구)

  • No, Bong-Hwan;Hwang, Ho-Keel;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.362-371
    • /
    • 1995
  • The purpose of this study was to evaluate the shear bond strength between composite resin and glass ionomer cement according to surface treatment methods of glass ionomer cement. Sixty round acrylic cylinders were fabricated. And then, a round undercut cavity(8 mm diameter, 2.5mm depth) was prepared in the center of the every acrylic cylinder. After all cavities were restored by using light-cured glass ionomer cement. A total of sixty acrylic cylinders restored with glass ionomer cement were divided into 4 groups according to surface treatment methods of glass ionomer cement. The surface treatment of each group were as follows : control group : no treatment Group 1 : acid etching Group 2 : sandblasting Group 3 : air-podwer abrasive polishing The composite resin was bonded to glass ionomer cement of each specimens. And the shear bond strength was tested with a universal testing machine at a cross-head speed of 1mm/min and 500kg in full scale. The results were as follows : 1. The sandblasting group(group 2) had the highest shear bond strength with $272.50{\pm}24.96\;kg/cm_2$ and the acid etching group(group 1) had the lowest shear bond strength with $192.89{\pm}29.32kg/cm_2$. 2. The no treated group(control group) had higher shear bond strength than acid etching group(group 1) (p<0.05). 3. The sandblasting group(group 2), air-powder abrasive polishing group(group 3) and no treated group(control group) had higher shear bond strength than the acid etching group(group 1) (p<0.05). 4. The sandblasting group(group 2) and air-powder abrasive polishing group(group 3) had higher shear bond strength than the no treatment group(control group), but there was not significant(p>0.05).

  • PDF

Study on the Characteristics of a Dash System Based on Test and Simulation for Vehicle Noise Reduction (승용차량의 소음저감을 위한 시험과 시뮬레이션을 이용한 대시 시스템의 특성 연구)

  • Yoo, Ji Woo;Chae, Ki-Sang;Cho, Jin Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.11
    • /
    • pp.1071-1077
    • /
    • 2012
  • Low frequency noises(up to about 200 Hz) such as booming are mainly caused by particular modes, and in general the solutions may be found based on mode controls where conventional methods such as FEM can be used. However, at higher frequencies between 0.3~1 kHz, as the number of modes rapidly increases, radiation characteristics from structures, performances of damping sheets and sound packages may be more crucial rather than particular modes, and consequently the conventional FEM may be less practical in dealing with this kinds of structure-borne problems. In this context, so-called 'mid-frequency simulation model' based on FE-SEA hybrid method is studied and validated to reduce noise in this frequency region. Energy transmission loss(i.e. air borne noise) is also studied. A dash panel component is chosen for this study, which is an important path that transmits both structure-borne and air borne energies into the cavity. Design modifications including structural modifications, attachment of damping sheets and application of different sound packages are taken into account and the corresponding noise characteristics are experimentally identified. It is found that the dash member behaves as a noise path. The damping sheet and sound packages have similar influences on both sound radiation and transmission loss. The comparison between experiments and simulations shows that this model could be used to predict the tendency of noise improvement.

A Case of Severe Asthma Complicated with Pneumoperitoneum and Pneumomediastinum During AMBU Ventilation (AMBU(Air Mask Bag Unit) 환기로 복강기종과 종격동기흉이 합병된 중증 천식 1예)

  • Cho, Hoon;Choi, Byoung-Moon;Jung, Ho-Kyoung;Park, Ja-Young;Jang, Byoung-II;SunWoo, Mi-Ok;Seo, Chan-Hee;Sung, Han-Dong;Sin, Mi-Jeong;Hwang, Soon-Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.6
    • /
    • pp.585-589
    • /
    • 2001
  • Pneumoperitoneum, Pneumomediastinum, subcutaneous emphysema and a pneumothorax are some of the mechanical complications of bronchial asthma. The incidence of pneumoperitoneum during an attack of acute asthma is rare. The pathogenesis is free gas track from the overdistended alveoli, through the bronchovascular sheaths to the mediastinum. If the high pressure is maintained, air can escape retroperitoneally into the abdomen and burst into the peritoneal cavity. A 43-year-old woman was admitted due to a severe asthma attack. She was required endotracheal intubation and AMBU(air mask bag unit) ventilation. Immediately after these procedures, pneumoperitonewn, pnewnomediastinwn, and subcutaneous emphysema developed. She was treated with mechanical ventilation and medical therapy. The pneumoperitonewn was resolved after 27days. Here, we report this case with the review of the relevant literature.

  • PDF

The Effect of Inferior Turbinectomy on Heat/Humidity Transfer Ability of the Nose (하비갑개수술이 비강의 열/습도 전달 특성에 미친 영향)

  • Chung, Kang-Soo;Chang, Ji-Won;Kim, Sung-Kyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.419-424
    • /
    • 2012
  • In addition to respiration, the nose performs three other major physiological functions-air-conditioning, filtering, and smelling. On the basis of our experience in experimental investigations of nasal airflows in normal and abnormal nasal cavity models, airflows in the normal model and three artificially deformed models, which simulate the results of surgical treatments (inferior turbinectomy), are investigated by PIV and CFD. The left cavities of all three models are normal, and the right cavities are modified as follows: (1) excision of the head of the inferior turbinate, (2) resection of the lower fifth of the inferior turbinate, and (3) resection of almost the entire inferior turbinate. The use of high-resolution CT data and careful surface rendering of three-dimensional computer models with the help of an ENT doctor provide more sophisticated nasal cavity models. Nasal airflows for both normal and deformed cases are also compared.

Mass Death of Predatory Carp, Chanodichthys erythropterus, Induced by Plerocercoid Larvae of Ligula intestinalis (Cestoda: Diphyllobothriidae)

  • Sohn, Woon-Mok;Na, Byoung-Kuk;Jung, Soo Gun;Kim, Koo Hwan
    • Parasites, Hosts and Diseases
    • /
    • v.54 no.3
    • /
    • pp.363-368
    • /
    • 2016
  • We describe here the mass death of predatory carp, Chanodichthys erythropterus, in Korea induced by plerocercoid larvae of Ligula intestinalis as a result of host manipulation. The carcasses of fish with ligulid larvae were first found in the river-edge areas of Chilgok-bo in Nakdong-gang (River), Korea at early February 2016. This ecological phenomena also occurred in the adjacent areas of 3 dams of Nakdong-gang, i.e., Gangjeong-bo, Dalseong-bo, and Hapcheon-Changnyeong-bo. Total 1,173 fish carcasses were collected from the 4 regions. To examine the cause of death, we captured 10 wondering carp in the river-edge areas of Hapcheon-Changnyeong-bo with a landing net. They were 24.0-28.5 cm in length and 147-257 g in weight, and had 2-11 plerocercoid larvae in the abdominal cavity. Their digestive organs were slender and empty, and reproductive organs were not observed at all. The plerocercoid larvae occupied almost all spaces of the abdominal cavity under the air bladders. The proportion of larvae per fish was 14.6-32.1% of body weight. The larvae were ivory-white, 21.5-63.0 cm long, and 6.0-13.8 g in weight. We suggest that the preference for the river-edge in infected fish during winter is a modified behavioral response by host manipulation of the tapeworm larvae. The life cycle of this tapeworm seems to be successfully continued as the infected fish can be easily eaten by avian definitive hosts.

A Study on Noise Reduction of Rotary Compressor (공조용 로터리 압축기의 소음 저감에 관한 연구)

  • Ahn, B.H.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.3 no.3
    • /
    • pp.60-69
    • /
    • 1999
  • The noise and vibration sources of rotary compressor for room air-conditioner are pressure pulsation of compression process, cavity resonance of inner space, structural radiation noise of shell and impact noise of discharge valve. Among them, pressure pulsation is very important noise and vibration source. Because it transferred various kinds of noise and vibration like as mentioned above. In this reason, muffler and resonator are used in order to absorb and remove these noises. But an analytical prediction using acoustic analysis does not coincident with the experimental result. The difference between analysis and actual state is due to the assumption of analysis. This paper covered with new concept of muffler design based on the turbulence kinetic energy of flow by using CFD. From this analysis, it is possible to decide the best position of discharge port of muffler. Therefore $2{\sim}3dB$ noise reduction effect is acquired in rotary compressor of 5000 BTU grade. Also new approach of resonator design is suggested. From this study, the characteristics of resonator and surge hole (a kind of resonator without pipe length) are identified. The former is useful for pure tone noise (narrow frequency band), and the latter is effective for broad frequency band. This paper shows that it is very available to use 3 dimensional analysis of resonator in order to predict more exact tuning frequency. The result is proved by a lot of experiments. From combination of fluid analysis and acoustic analysis, up stream position is effective location of resonator concerning turbulence motion of fluid.

  • PDF

Disposal of CO in CO-Poisoning Dogs (일산화탄소중독견(一酸化炭素中毒犬) 체내(體內)에서의 일산화탄소처리능(一酸化炭素處理能)에 관(關)하여)

  • Ryo, Ung-Yun;Kang, Bann
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.93-99
    • /
    • 1968
  • The Present study attempted to analyze the fate of CO diffused into the circulating blood through the alveoli. Dogs were induced to CO poisoning by rebreathing CO gas mixture contained in Krog's spirometer, by closed circuit method, for 60 minutes. The spirometer was filled initially with 282 ml of CO and 20 liters of air and oxygen, so the composition of gases were arranged as 1.4% in CO and 50% in $O_2$ at the begining of the rebreathing. Oxygen was added corresponding to the utilization of $O_2$ by the animal in proceeding of the experiment. At 60th minutes of CO rebreathing, the concentration of CO in arterial blood and in mixed venous blood were analysed and compared with each other after the CO contents were corrected with the hematocrit measured in the arterial and mixed venous blood. The distribution of CO gas to other tissues was estimated by the analysis of CO diffused into the cystic bile and into the peritoneal gas pocket which was formed by injection of 300 ml air into the peritoneal cavity prior to the CO gas rebreathing. The blood volume was measured by dilution method using $^{51}Chromium$ tagged red cells. CO amount vanished in the animal body was calculated by subtraction of total CO content in blood stream and the CO remained in closed circuit breathing system from the CO amount given to the breathing system at the begining of the experiment. Results obtained are summarized as follows: 1. The content of CO corrected by the hematocrit value was slightly less in mixed venous blood than in arterial blood. The amount of CO diffused into the cystic bile and into the peritoneal cavity was averaged to 0.1% and 0.4% of the CO amount in 100 ml of blood, respectively. 2. For 60 minutes of CO rebreathing, CO-hemoglobin saturation reached about 77% at the 60th minutes, CO amount vanished in the experimental animal averaged 36.1 ml/dog/hr., or 21% of the total CO volume in the blood stream. The average vanishing rate of CO during 60 minutes of CO rebreathing per kg of body weight was 2.71 ml/hr. Production of CO measured in ten dogs under hypoxic condition averaged 0.023 ml/kg/hr. The major part of the CO vanished in the dogs seemed to be oxidized to $CO_2$ by various tissues of the animal. The conclusion might be delivered as such oxidation of CO to $CO_2$ by animal tissues can play a role in part of the process of recovery and protection of animal from CO-poisoning.

  • PDF

Studies on Mycoplasma Infection of Laboratory Mice and Antibiotic Susceptibility against Isolates (실험용(實驗用) 마우스의 Mycoplamsa감염(感染) 실태(實態)와 분리주(分離株)의 항생제(抗生劑) 감수성(感受性)에 관한 연구(硏究))

  • Chung, Yoo-yeal;Cho, Sung-yong;Lee, Hak-cheul
    • Korean Journal of Veterinary Research
    • /
    • v.26 no.2
    • /
    • pp.283-292
    • /
    • 1986
  • Isolation and identification of Mycoplasma were performed to clarify Mycoplasma infection of mice fed by conventional feeding at two ($K_1$, $K_2$) institutes in Korea. The twenty mice to be tested were randomly sampled from each of 10 breeding colonies in respective institute. Identification of the Mycoplasma strains isolated from the nasal cavity, lung and synovia of mice was made according to the morphology of colonies, biological and biochemical properties with special reference to M. pulmonis, M. arthrotodis and M. neurolyticum. In addition, growth inhibition test was performed using hyperimmune rabbit antisera to the strain PG-22 of M. pulmonis, the strain PG-6 of M, arthritidis and the strain PG-28 of M. neurolyticum and also differentiation of isolates from L-form bacteria was dont by Dieses staining and culture method with passage of the isolates on liquid media eliminated antibacterial drug. On the other hand, a total of 13 strains out of the 44 isolated M. pulmonis from mice was investigated for their susceptibility against 16 antibiotics in vitro. The antibiotic sensitivity test was made using $3{\times}10^4$ organisms/0.3ml on each plate(90mm diameter) with antibiotic mono-or tri-disk. The results obtained are summarized as follows: 1. Out of 20 mice from 10 breeding colonies in Kl institute, mycoplasma-like strains from the nasal cavity of 16 mice(80%) and from the lung of 8 mice(40%) were isolated, while out of 20 mice in K2 institute, M-like strains were isolated from the nasal cavity of 14 mice(70%) and from the lung of 6 mice(30%). However, no mycoplasma-like organisms were isolated from the synovia of the 40 mice examined. All the 44 strains isolated were identified as the organisms of M. pulmonis. 2. Out of the 16 antibiotics tested, penicillin, oleandomycin and bacitracin showed no activity against all the 13 M. pulmonis strains. On the contrary, lincomycin, clindamycin, chloramphenicol, tetracycline, minocycline, kanamycin, gentamycin and tobramycin showed high activity with three different antibiotic concentration of tridisk, but amikasin and spiramycin showed intermediate activity. Other antibiotics such as polymyxin B and colistin showed low activity, while erythromycin showed lower activity than others.

  • PDF

EFFECT OF A REWETTING AGENT ON DENTIN ADHESION (재습윤제의 적용이 상아질 접착에 미치는 효과)

  • Cho, Young-Gon;Park, Yil-Yoon;Lee, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.11-22
    • /
    • 2003
  • This study compared the dentin adhesion to composite resin according to air-dry, blot dry, application of rewetting agent on air-dry or blot dry dentin surface by microleakag test and SEM observation. For microleakage test, class V cavity preparations with dentinal margins were prepared on both buccal and lingual surfaces of 40 extracted human molars. For SEM observation, occlusal dentin of 20 extracted human molars were exposed. After etched the dentin, prepared teeth were randomly divided into four groups; D group: air dry for 10-15 sec., B group: blot dry with moist cotton pellet, D-R group: air dry and rewet with Aqua-Prep F for 20 sec., B-R group: blot dry and rewet with Aqua-Prep F for 20 sec. Treated cavities and surfaces were filled or constructed using One-Step adhesives and Aelitefil composite resins. Specimens were stored in distilled water for 24 hours. For microleakage test, the specimens were thermocycled and soaked into 2% methylene blue. The specimens were sectioned longitudinally and evaluated for microleakage under steromicroscope. The data were statistically analysed by Kuskal-Wallis Test, Mann-Whitney and Wilcoxon signed ranked tests. For SEM observation, the specimens were bisectioned mesiodiatally. After decalcified and deproteinized, specimens were observed under SEM. The results of this study were as follows; 1. The microleakges on dentinal margin were the highest in D group compared with B group, D-R group, and B-R group(p<0.05). But there was no significant difference between B group, D-R group and B-R group. 2. D group showed gap and a few resin tags between dentin and composite resin. 3 B group, D-R group, and B-R groups showed close adaptation between dentin and composite resin. It showed that resin rags in B group were numerous and long, in D-R group were few and short, in B-R group were numerous and short or long. 4. Adhesive layer showed in D-R group ($10{\;}\mu\textrm{m}$) and B-R group ($3{\;}\mu\textrm{m}$) In conclusion, use of rewetting agent to dry dentin was efficient to dentin adhesion, also it did not provide reverse effect on blot dry dentin.