• 제목/요약/키워드: aerosols

검색결과 587건 처리시간 0.027초

A Chemical Analysis of Airborne Particulates at the near Coast Site, Ul-jin Geun Gyungbook

  • Lee, Dong Sub;Park, Jin Sik
    • 한국환경과학회지
    • /
    • 제24권5호
    • /
    • pp.615-622
    • /
    • 2015
  • East Asia is characterized by anthropogenic emissions resulting from the large population and fast economic growth of this region. Since the prevailing wind is westerly and northwesterly, emissions from Ul-jin can be expected to contribute to acidic deposition increase in downwind direction. Aerosols collected at the near coast site, Uljin geun, gyungbook and were analyzed for $NH_4{^+}$, $Mg^{2+}$, $Na^+$, $Ca^{2+}$, $Cl^-$, $SO_4{^{2-}}$, and $NO_3{^-}$ from Aug. 2012 to Feb. 2013. The seasonal averaged aerosol concentration showed the highest potassium and calcium ion in winter and the highest ammonium ion due to a meadow and high solar intensity in summer. Sodium and chloride ion showed the same ratio all seasons and sulfate and nitrate species showed the maximum value in winter Chemical components of aerosols collected at the near coast site, Uljin geun, gyungbook were lower by 16 to 73% than those collected at other similar environment site such as kanghwa, yangyang. Comparing air quality data at the near coast site, Uljin geun, gyungbook, There was found that Uljin coast site is less influenced by the sea salts(potassium, magnesium, calcium) and nss-$SO_4{^{2-}}$ percentage is 3~13% higher than similar condition site.

The Occupational Exposure Limit for Fluid Aerosol Generated in Metalworking Operations: Limitations and Recommendations

  • Park, Dong-Uk
    • Safety and Health at Work
    • /
    • 제3권1호
    • /
    • pp.1-10
    • /
    • 2012
  • The aim of this review was to assess current knowledge related to the occupational exposure limit (OEL) for fluid aerosols including either mineral or chemical oil that are generated in metalworking operations, and to discuss whether their OEL can be appropriately used to prevent several health risks that may vary among metalworking fluid (MWF) types. The OEL (time-weighted average; 5 mg/$m^3$, short-term exposure limit ; 15 mg/$m^3$) has been applied to MWF aerosols without consideration of different fluid aerosol-size fractions. The OEL, is also based on the assumption that there are no significant differences in risk among fluid types, which may be contentious. Particularly, the health risks from exposure to water-soluble fluids may not have been sufficiently considered. Although adoption of The National Institute for Occupational Safety and Health's recommended exposure limit for MWF aerosol (0.5 mg/$m^3$ ) would be an effective step towards minimizing and evaluating the upper respiratory irritation that may be caused by neat or diluted MWF, this would fail to address the hazards (e.g., asthma and hypersensitivity pneumonitis) caused by microbial contaminants generated only by the use of water-soluble fluids. The absence of an OEL for the water-soluble fluids used in approximately 80-90 % of all applicants may result in limitations of the protection from health risks caused by exposure to those fluids.

충주시 초미세먼지 (PM2.5)의 배출원 기여도 추정에 관한 연구 (Source Apportionment of Fine Particulate Matter (PM2.5) in the Chungju City)

  • 강병욱;이학성
    • 한국대기환경학회지
    • /
    • 제31권5호
    • /
    • pp.437-448
    • /
    • 2015
  • The purpose of this study is to present the source contribution of the fine particles ($PM_{2.5}$) in Chungju area using the CMB (chemical mass balance) method throughout the four seasons in Korea. The Chungju's annual average level of $PM_{2.5}$ was $48.2{\mu}g/m^3$, which exceeded two times higher than standard air quality. Among these particles, the soluble ionic compounds represent 54.2% of fine particle mass. Additionally, the OC concentration in Chungju stayed similar to other domestic cities, while the EC concentration decreased significantly compared to other domestic/international cities. The concentration of sulfur represented the highest composition (8%) among the fine particle compounds. According to the CMB results, the general trend of the $PM_{2.5}$ mass contributors was the following: secondary aerosols (50.5%: ammonium sulfate 26.5% and ammonium nitrate 24.0%) > gasoline vehicle (18.3%) > biomass burning (11.0%) > industrial boiler (6.0%) > diesel vehicles (4.4%). The contribution of the secondary aerosols was the main cause than others. This impact is assumed to be emitted from air pollutants of urban cities or neighbor countries such as China.

HPLC-FLD를 이용한 겨울철 PM2.5 중 아미노산 성분 분석 (Determination of Amino Acids on Wintertime PM2.5 using HPLC-FLD)

  • 박다정;조인환;배민석
    • 한국대기환경학회지
    • /
    • 제31권5호
    • /
    • pp.482-492
    • /
    • 2015
  • Ground-based measurements were conducted from January 6 to 12 of 2015 for understanding characteristics of nitrogen containing carbonaceous aerosols as 16 amino acids at the Mokpo National University, Korea. The detailed amino acid components such as Cystine ($(SCH_2CH(NH_2)CO_2H)_2$) and Methionine ($C_5H_{11}NO_2S$) and their sources were analyzed by High-Performance Liquid Chromatography with Fluorescence Detection (HPLC-FLD) for behavior of secondary products in particulate matter. In addition, organic carbon (OC) and elemental carbon (EC) based on the carbonaceous thermal distribution (CTD), which provides detailed carbon signature characteristics relative to analytical temperature, and water soluble organic carbon (WSOC) by total organic carbon (TOC) analyzer were used to understand the carbon compound behaviors. The backward trajectories were discussed for originations of carbonaceous aerosols as well. Different airmasses were classified with the amino acids and OC thermal signatures. The results can provide to understand the aging process influenced by the long-range transport from East Sea area.

전기가열 튜브로를 이용한 나노/서브마이크론 입자의 발생 (Generation of Nano/Submicron Particles Using an Electrically Heated Tube Furnace)

  • 지준호;배양일;황정호;배귀남
    • 대한기계학회논문집B
    • /
    • 제27권12호
    • /
    • pp.1734-1743
    • /
    • 2003
  • Aerosol generator using an electrically heated tube furnace is a stable apparatus to supply nanometer sized aerosols by using the evaporation and condensation processes. Using this method, we can generate highly concentrated polydisperse aerosols with relatively narrow size distribution. In this work, characteristics of particle size distribution, generated from a tube furnace, were experimentally investigated. We evaluated effects of several operation parameters on particle generation: temperature in the tube furnace, air flow rates through the tube, size of boat containing solid sodium chloride(NaCl). As the temperature increased, the geometric mean diameter increased and the total number concentration also increased. Dilution with air affected the size distribution of the particles due to coagulation. A smaller sized boat, which has small surface area to contact with air, brings smaller particles of narrow size distribution in comparison of that of a larger boat. Finally, we changed the electrical mobility diameter of aggregate sodium chloride particles by varying relative humidity of dilution air, and obtained non-aggregate sodium chloride particles, which are easy to generate exact monodisperse particles.

치과 병원의 COVID-19 예방:문헌 검토에 따른 대응 전략 (Prevention of COVID-19 in Dental Hospitals: Literature Review and Countermeasures)

  • 이정원;김여진;정하늘;이용무
    • 대한치과의사협회지
    • /
    • 제58권10호
    • /
    • pp.615-626
    • /
    • 2020
  • The outbreak of COVID-19, caused by SARS-CoV-2 infection, has spread worldwide and resulted in a pandemic for health systems. The disease is transmitted via respiration as droplets or aerosol. Due to the nature of dental treatment, aerosols, including body fluid, blood, and saliva, are frequently produced in dental hospitals. The present study investigated the potential risk of nosocomial infection of COVID-19 in dental hospitals to provide recommendations in clinical situations. The Seoul National University Dental Hospital in Korea established a countermeasure to cope with the clinical situation based on The Guidelines of Korean Centers for Disease Control & Prevention (KCDC) for dental practitioners and the available literature. Notably, numerous considerations for patient reservation and schedule management are required for space separation in the hospital, including infection control. Experiences in dental hospitals in Korea would be referable for other dental hospitals facing this infectious respiratory disease.

  • PDF

On-line Measurement of the Surface Area Concentration of Aerosols in Yokohama, Japan, using the Diffusion Charging Method

  • Hatoya, Kazuki;Okuda, Tomoaki;Funato, Koji;Inoue, Kozo
    • Asian Journal of Atmospheric Environment
    • /
    • 제10권1호
    • /
    • pp.1-12
    • /
    • 2016
  • Numerous researchers have proposed that surface area is a more appropriate indicator than mass for evaluating pulmonary inflammatory responses caused by exposure to fine and ultrafine particles. In this study, measurements of surface area concentrations of aerosols were conducted in Yokohama, Japan, using the diffusion charging method. $PM_{2.5}$ mass concentration and black carbon concentration in $PM_{2.5}$ were also measured. The 24-hour continuous measurement campaigns were conducted 39 times from March to November, 2014. The surface area concentration was more closely correlated with the black carbon concentration than with the $PM_{2.5}$ mass concentration. It is considered that the abundance of black carbon particles significantly affects the surface area concentration of $PM_{2.5}$. The strength of the correlation between the surface area and black carbon concentrations varied considerably among the measurement campaigns. A relatively weaker afternoon correlation was observed compared with the other time zones (morning, evening, and night). We consider that these phenomena are due to the transportation/formation of the particles other than black carbon that affects surface area concentration and/or the variation of the surface condition of the black carbon particles.