• 제목/요약/키워드: advanced wastewater treatment process

검색결과 237건 처리시간 0.029초

Pulse UV 장치를 이용한 원유비축시설 발생폐수의 난분해성 유기오염물질 제거 (Removal of Non-biodegradable Organic Contaminants in Wastewater from crude oil reserve base Using Pulse UV System)

  • 손진식;박순호;정의택
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.861-867
    • /
    • 2011
  • Wastewater from crude oil reserve base usually contains large amount of non-biodegradable contaminants. The conventional wastewater treatment progress can hardly meet the regulation of wastewater effluent quality. This study investigated the removal of non-biodegradable organic contaminants in wastewater from crude oil reserve base using a pulse UV treatment. The modified process incorporating pulse UV process was set up to treat the wastewater from crude oil reserve base. The treatment process is composed with coagulation and flocculation, micro-bubble flotation, sand filter, pulse UV system, and GAC filter. The results show CODMn was effectively removed by the process with pulse UV system and it can meet the wastewater effluent regulation. The single effect of pulse UV process in CODMn removal was not significant(9~15% based on sand filtered effluent), however with the subsequent activated carbon filter the removal ratio CODMn was increased up to 28% compared to the process without pulse UV syetem.

파일럿 플랜트 규모에서 일체형 침전부상공정 (SeDAF)의 설계인자 및 운전특성에 대한 실증적 평가 (Empirical evaluation for design parameters and operating characteristics of the integrated sedimentation and dissolved air flotation (SeDAF) process at the pilot-scale plant)

  • 장여주;정진홍;임현만;김원재
    • 상하수도학회지
    • /
    • 제35권1호
    • /
    • pp.1-14
    • /
    • 2021
  • Eutrophication and algal blooms can lead to increase of taste and odor compounds and health problems by cyanobacterial toxins. To cope with these eco-social issues, Ministry of Environment in Korea has been reinforcing the effluent standards of wastewater treatment facilities. As a result, various advanced phosphorus removal processes have been adopted in each wastewater treatment plant nation-widely. However, a lot of existing advanced wastewater treatment processes have been facing the problems of expensive cost in operation and excessive sludge production caused by high dosage of coagulant. In this study, the sedimentation and dissolved air flotation (SeDAF) process integrated with sedimentation and flotation has been developed for enhanced phosphorus removal in wastewater treatment facilities. Design and operating parameters of the SeDAF process with the capacity of 100 ㎥/d were determined, and a demonstration plant has been installed and operated at I wastewater treatment facility (located in Gyeonggi-do) for the verification of field applicability. Several empirical evaluations for the SeDAF process were performed at demonstration-plant scale, and the results showed clearly that T-P and turbidity values of treated water were to satisfy the highest effluent standards below 0.2 mg/L and 2.0 NTU stably for all of operation cases.

Bacillus subtilis를 이용한 폐수처리 효과연구: 오존의 영향을 중심으로 (Study of wastewater-treatment's efficiency using Bacillus subtilis: with an effect of ozonation)

  • 박영규
    • 환경위생공학
    • /
    • 제17권4호
    • /
    • pp.29-38
    • /
    • 2002
  • Advanced oxidation of wastewater was studied with a purpose to remove TOC and color by the ozone-assisted Fenton reaction. The optimal conditions were determined by hydrogen peroxide and ozone concentrations. Experimental results indicate that the ozone treatment after Fentons process was found to provide very efficient removal efficiency in the process, avoiding the exclusive ozone treatment. The combined process of ozone in the Fenton oxidation respectively was increased removal efficiences of 10.7% in comparison with exclusive Fenton oxidation. Also, the treatments of ozone after Fenton's oxidation respectively had increased the removal efficiences of 16.%. As a result, the treatment of ozone after Fentons oxidation had the best removal efficiency of approximately 96%. Removal efficiency of color was significantly increased as mush as 26% by the advanced Fenton's oxidation in comparison with exclusive Fenton's oxidation. The removal efficiencies in the biological treatment using Bacillus subtilis after Fenton's oxidation and after Fenton's and ozone's oxidation were increased by 14% and 19% respectively. Although these combined Bacillus subtilis-assisted Fenton's oxidation was determined to be effective method to treat the dyeing wastewater in an economic point of view, the choice of wastewater treatment can be varied depending on water quality.

고도처리공정이 관로 내 잔류염소 감소 및 THM 생성에 미치는 영향 (Effect of Advanced Treatment Process for Residual Chlorine Decay and THM Formation in Water Distribution System)

  • 이두진;김영일;김성수;이경혁;박현아
    • 대한환경공학회지
    • /
    • 제29권4호
    • /
    • pp.419-424
    • /
    • 2007
  • 깨끗하고 안전한 수돗물에 대한 소비자들의 욕구가 커짐에 따라 막, 오존, 활성탄 등 다양한 고도처리공정이 정수장에 도입되고 있다. 본 연구에서는 고도처리공정의 도입으로 인한 관로 내 잔류염소 감소 및 THM 생성특성에 대하여 살펴보았다. 오존, 활성탄, 오존/GAC 공정별 DOC 제거특성과 bottle test를 이용한 잔류염소 감소 및 THM 생성특성을 평가하였다. 모든 처리공정에서 DOC 제거율보다 $UV_{254}$ 유발물질의 제거율이 우수한 것으로 나타났다. 특히, 오존공정에 의한 DOC 제거율은 기존 모래여과수 대비 약 4%에 불과하였으나, $UV_{254}$는 약 17%로 DOC 제거율보다 훨씬 더 큰 차이를 보였는데, 이는 오존에 의해 소수성 유기물이 친수성 유기물로 변환되었기 때문이다. 오존/GAC 공정이 유기물 제거에 가장 효과적이었으며, 모래여과, 오존, GAC, 그리고 오존/GAC공정을 거친 처리수의 잔류염소 감소계수는 각각 0.0230, 0.0307, 0.0117 그리고 0.0098 $hr^{-1}$ 나타났으며, 190시간 반응 이후 모래여과수는 THM이 81.8 ${\mu}g/L$ 생성된 반면, 오존, GAC, 그리고 오존/GAC의 처리수는 모래여과수에 비해 각각 6.0, 26.2, 30.3% 적게 생성되었다. 결론적으로 고도처리공정에 의해 관로 내 잔류염소의 지속성이 증대되었으며, THM 생성 또한 감소하는 것으로 나타났다.

Membrane Filter를 이용한 수산물 가공폐수처리에 대한 연구 (Research of Sea Food Wastewater Treatment using Membrane Filter)

  • 한동준
    • 환경위생공학
    • /
    • 제22권4호
    • /
    • pp.119-130
    • /
    • 2007
  • Sea food wastewater including high concentration of organics and nutrients is hard to treat stably by established traditional activated sludge process. This research is aimed to obey more and more of strengthened the law and to secure stable effluents by using advanced treatment process applied membrane filter in aeration tank for treatment of wastewater from marine products. It must maintain pH of influent over 6.0 to keep up stably biological sludge of advanced treatment process. At 38hr of HRT, removal rates of TBOD and TCOD were 99.9% and 99.4% respectively and TSS also removed with high efficiency. Most organics in the effluent was constituted with soluble type materials, it caused that membrane filter installed aeration tank should remove minute suspended particles. The reactor was operated well to get stable treatment results for operation period, in spite of high loading of organics like that $0.67{\sim}1.67\;kgTBOD/m^3/day$ of organics loading and $0.10{\sim}0.21\;kgBOD_5/kgMLSS/day$ of F/M ratio. At $36{\sim}48hr$ of HRT, removal rates of T-N and T-P were $89.7{\sim}90.7%\;and\;91.5{\sim}96.0%$ respectively. It means this treatment process also work to remove nutrients of high concentration. Upon investigation of advanced treatment's operation factors, optimum SRT was about 30days and average SNR that showed tendency to increase according to increase water temperature was calculated 0.014 gN/g MLVSS/d. SDNR was risen in conformity to increase F/M ratio of Non-aeration tank and investigated as $0.038{\sim}0.051\;gN/gMLVSS/d$.

충청남도 마을하수처리시설의 최적 설치방안 (Alternatives for Optimum Installation of Rural Sewage Treatment Facilities in Chungchongnam-do Province)

  • 이상진;정종관;임봉수;허재영
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.462-472
    • /
    • 2005
  • This study was carried out to suggest the plans for installation of rural sewage treatment facilities through the analysis of these facilities installed in Chungchongnam-do Province. About 5% of all installation was carried out by the department of wastewater and related environment problems and the other case was carried out by the department of construction or residence. In wastewater caused by 250 and 300 persons, facilities capacity do not exceed about $50m^3/d$, caused by 2,500 and 3,000 persons, $500m^3/d$. Advanced sewage treatment process were first needed in the discharge area where affected the water environment greatly. However, in carrying out the water quality pollutant of the total amount management system in the other areas, they should be driven only over the scale of pollutant quota object facilities standard. Rural sewage must be included in the special accounts according to the regulations of local government, and sewage treatment cost should be collected to manage. Installation type uses integrating joint treatment method in case the distance among villages is short or one treatment facility independently.

가죽, 모피 가공 및 제조업 폐수처리시설의 경제성 평가 (Economical Assessment of Wastewater Treatment Facilities in Leather Tanning and Finishing Industry)

  • 김재훈;양형재;권오상;이성종
    • 한국물환경학회지
    • /
    • 제23권1호
    • /
    • pp.131-137
    • /
    • 2007
  • Industrial wastewater management guideline and evaluation model of Best Available Technologies for the leather tanning and finishing industry was developed as an economical evaluation model using evaluation of BAT including economical evaluation combined with cost analysis model and cost annualization model in considering of economical factors and non-water environmental factors. It was verified that approximately 10% will be increased annually to modify conventional treatment process ($3,700m^3/d$) of J leather wastewater treatment plant to advanced process of K leather wastewater treatment plant.

고도 하수처리장의 전과정평가에 따른 환경성 및 경제성 평가 (Evaluation of Environmental and Economic Impacts of Advanced Wastewater Treatment Plants with Life Cycle Assessment)

  • 표세희;김민정;이승철;유창규
    • Korean Chemical Engineering Research
    • /
    • 제52권4호
    • /
    • pp.503-515
    • /
    • 2014
  • 최근 하수처리장의 질소 및 인 방류수 수질기준이 강화되고 슬러지의 해양투기가 금지됨에 따라 기존 표준활성슬러지공법의 고도처리공법으로의 증설 및 새로운 하수슬러지 처리공법에 대한 환경성, 경제성 평가의 필요성이 증가하고 있다. 이러한 고도처리 및 슬러지 처리공법은 운영 단계뿐만 아니라 건설, 폐기를 포함한 전과정에 걸쳐 환경 전반에 영향을 미치며 경제적 비용을 소모하므로, 본 연구에서는 건설에서부터 폐기까지의 전과정을 고려하여 고도처리공정 및 슬러지 처리 공법의 환경성, 경제성을 평가하고자 한다. 고도처리공법으로 Anaerobic/Anoxic/Oxic ($A_2O$), Bamard Denitrification Phosphate (Bardenpho), Virginia Initiative Plant (VIP), Modified University of Cape Town (MUCT) 공법을, 슬러지 처리공법으로는 매립, 소각, 퇴비화를 선정하였다. 각 공법에 따른 환경성, 경제성 평가를 위하여 International organization for standardization (ISO)에서 제시하는 가이드라인을 따라 전과정평가를 수행하였으며, 전생애비용을 산정 비교하였다. 각 고도처리 공법에 대한 평가 결과, 환경영향 측면에서는 운영 단계에서의 생물학적 처리로 인한 온실가스 배출이, 경제성 측면에서는 운영 단계에서의 전력소모가 가장 많은 영향을 미치는 것으로 나타났다. 또한 가장 친환경적인 하수처리 및 슬러지 처리공법은 $A_2O$ 공법과 퇴비화로 환경에 가장 큰 영향을 미치는 CAS 공법과 매립에 비해 환경영향을 52% 줄일 수 있는 것으로 나타났다. 경제적인 측면에서는 가장 많은 비용을 소요하는 CAS 공법과 매립 적용 시에 비해 MUCT 공법과 퇴비화가 전생애비용을 62% 절약할 수 있음을 알 수 있었다. 본 연구를 통해 고도처리 공법으로의 증설 및 슬러지 처리에 대한 전과정을 고려하여 친환경적이며 경제적인 공법을 선정하기 위해 전과정평가를 수행하고 전생애비용을 산출하여 각 공법을 비교 및 평가하였으며, 전과정평가의 환경성 및 경제성에 중요한 영향인자를 분석하였다. 따라서 본 연구의 방법론을 통하여 환경부하 및 경비 절감을 고려한 고도처리공법의 개보수 공정 및 슬러지 공정 선택이 가능할 것으로 예상된다.

생물막 담체를 이용한 실험실 규모 $A_{2}O$공법의 시스템 변형에 따른 고도처리 성능 평가에 관한 연구 (The Study on Evaluating Performances of Lab Sacle-Advanced $A_{2}O$ with Changing System Using Biofilm Process)

  • 김민식;강구영
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.209-218
    • /
    • 2012
  • Recently, as reinforced water quality standards for wastewater has been announced, more efficient and more powerful wastewater treatment processes are required rather than the existing activated sludge process. In order to meet this demands, we evaluate Task 1-4 about lab scale $A_{2}O$ process using biofilm media. Task 1, 2, and 3 use 'Module A' which has 4 partitions (Anoxic/Anerobic/Oxic/Oxic). Task 4 uses 'Module B' which has 2 partitions including a denitrification reactor with an Inclined plug flow reactor (IPFR) and a nitrification reactor with biofilm media. The denitrification reactor of Module B is designed to be upward flow using IPFR. The result of evaluating at each Task has shown that attached growth system has better capacity of removal efficiency for organic matter and nitrogen with the exception of phosphorus. Task 4 which has the most outstanding removal efficiency has 90.5% of $BOD_{5}$ removal efficiency, 97.8% of ${NH_4}^{+}-N$ removal efficiency, 65% of T-N removal efficiency and 92% of T-P removal efficiency with additional chemical phosphorus removal system operated at HRT 9hr, Qi:Qir 1:2, and BOD/T-N ratio 2.7.

고급산화공정을 이용한 아세트아미노펜 분해 성능 비교 (Comparison of Acetaminophen Degradation Performance using Advanced Oxidation Process)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제31권4호
    • /
    • pp.319-328
    • /
    • 2022
  • This study investigated the treatment of acetaminophen in municipal wastewater by conventional ozonation, ozone-based advanced oxidation, ozone/UV, and the electro-peroxone process. The ozone/UV process and electro-peroxone process of electric power consumption increased 1.25 and 2.04 times, respectively, compared to the ozone process. The pseudo-steady OH radical concentration was the greatest in the electro-peroxone process and lowest in the ozone process. The specific energy consumption for TOC decomposition of the ozone/UV process and electro-peroxone process were 22.8% and 15.5% of the ozone process, respectively. Results suggest that it is advantageous in terms of degradation performance and energy consumption to use a combination of processes in municipal wastewater treatment, rather than an ozone process alone. In combination with the ozone process, the electrolysis process was found to be more advantageous than the UV process.