A study on the location of microphones in measurement considering the frequency characteristics of elevator noise in households (세대 내 승강기 소음 주파수특성을 고려한 측정 시 마이크로폰 위치에 관한 연구)

  • Min-Woo Kang;Yang-Ki Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.124-132
    • /
    • 2023
  • When the building becomes high, the number of households increases and they are adjacent to the elevator. So, frequency of use of elevators will increase. Elevator noise is bound to increase in the future. However, there are currently no legal standards for elevator noise or measurement and evaluation methods that can clearly measure elevator noise in Korea. Although some methods for measuring elevator noise are presented in KS F ISO 16032, this standard is not a standard established for elevator noise. It is a standard that integrates the overall measurement method of building equipment and equipment, and the position of the microphone is selected by the experimenter during measurement. Elevator noise is characterized by a low sound pressure level as the noise in the mid-low frequency band is important. However, even today, complaints from residents about elevator noise are increasing. In this study, the position of the microphone that can most sensitively pick up the elevator noise when measuring the elevator noise was studied. According to the distance from the wall and the height from the floor, a total of 9 microphone positions were measured and analyzed. As a result of the experiment, it was confirmed that the elevator noise has a very high influence in the 63 Hz band. The measured value at the center point was identified as a factor that lowered the overall elevator noise level value.

A Study of Empirical Analysis on Drencher Facilities through Delphi and IPA Analysis (델파이분석과 IPA분석을 통한 드렌처설비의 실증적 분석 연구)

  • Soo Un O;Sung-Hoon Choa
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.177-191
    • /
    • 2024
  • Purpose: In this study, the Drenzer facility, which is a facility installed to prevent the spread of fire caused by fire in adjacent buildings in the fire prevention zone, was analyzed legally and technically. We confirmed the uncertainty of the Building Act and the Fire Protection Act, and suggested the revision of the necessary standards. Method: Although the Drenzer facility is a building facility, it is actually applied in the field of firefighting, so the Delphi analysis was conducted on a panel composed of architectural experts and firefighting experts in the first, second, and third rounds to find the issuses and important facility component elements. Finally, the IPA(Importance-Performance Analysis) analysis was conducted to identify the importance of the elements that need to be revised. Result: Delphi analysis was carried out for experts on various components of Drenzer equipment in the first, second, and third rounds, and it was found that the survey items of the head, detector, and other facilities of the Drenzer equipment are valid items to identify problems. The IPA analysis indicated that the revision of the standards for Drencher head was necessary as a priority. Conclusion: In this study, it was possible to confirm the opinions of experts through Delphi analysis on the legal and technical problems of Drencher facilities, and it was confirmed that among the components of the Drencher facility, the revision of the head-related regulations is required as a priority.

A Study on the Structure Style of Street Green Spaces on Port Island, Kobe, Japan (일본 고베시(神戶市) 포트아일랜드 가로녹지 구조 유형 연구)

  • Kwak, Jeong-In;Han, Bong-Ho;Noh, Tai-Hwan;Kwak, Nam-Hyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.4
    • /
    • pp.62-74
    • /
    • 2015
  • This study was carried out to provide examples of planting methods for the construction of street green spaces with abundant greenery by analyzing road type, surrounding land use and planting structures in street green spaces on Port Island, Kobe, Japan. Port Island_(total area: 826ha) is a marine cultural city located in Japan's first artificial island with facilities of urban function and port facilities. The study site was designated at 11 plots of $55{\sim}285m^2$ on Port Island, and topography structure styles were divided into four types with mounding style, slope style, slope and flat style, flat style according to the adjacent roads width. The area adjacent to the middle roads with high levels of noise and pollution set up the mounding style, slope style, slope and flat style of multi-layer structures using topographic properties. The area adjacent to small roads focused on a green strip with shrubs on a flat style. Surrounding land-uses include a public institution, housing complex, and a commercial building. The planting concept was a buffer and landspace function in case of the middle road_(lane 4) while the small road_(lane 2) was a landspace function. Planting species were diverse with Liquidambe formosana, Cinnamomum camphora, Sapium sebiferum, Cedrela sinensis, Laeocarpus sylvestris var. ellipticus, Ginkgo biloba, Prunus serrulata var. spontanea, Zelkova serrata, Quercus glauca, Juniperus chinensis, Magnolia kobus, Rhododendron spp., Camellia japonica, Abelia mosanensis, etc. Planting density was 0.02~0.08(0.04) individual/$m^2$ at the canopy layer, 0.02~0.08(0.04) individual/$m^2$ at the understory layer. Ratio of green coverage was 40.0~173.7(93.0)% at the canopy layer, 2.1~79.8(34.9)% at the understory layer and 17.9~64.2(32.9)% at the shrub layer. $Gr{\ddot{u}}volumenzahl$ was $1.43{\sim}6.67(4.13)m^3/m^2$ at the canopy layer, $0.02{\sim}2.01(0.85)m^3/m^2$ at the understory layer and $0.14{\sim}0.58(0.26)m^3/m^2$ at the shrub layer. The ratio of green coverage of street green space on Port Island was higher than that of Seoul, and particularly, the ratio of green coverage and $gr{\ddot{u}}volumenzahl$ at the shrub layer differed, compared to the main street green space in Korea. The result of this study may be applicable to other coastal reclaimed cities in terms of setting methods for street greenery considering the topography structure, planting structure and planting function.

Changes in Construction and Characteristics during the Period of Foundation and Change of the Garden Pond Site in Guhwang-dong, Gyeongju (경주 구황동 원지(九黃洞 園池) 유적 창건 및 변화 시기의 조영과 성격 변화)

  • KIM, Hyungsuk
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.3
    • /
    • pp.102-118
    • /
    • 2022
  • Gyeongju, the capital of Silla, is the very essence of the culture and technology of the thousand-year-reign of Silla. However, few studies have been conducted on the landscape sites of the capital of Silla other than Donggung Palace and Wolji Pond, due to the lack of related data. Therefore, this study examined the construction characteristics and nature of the garden pond in Guhwang-dong, whose complete appearance was identified through excavation following Donggung Palace and Wolji Pond. Since the excavation of the garden pond in Guhwang-dong, Gyeongju, there have been disagreements in academia as to whether it is a palace pond or a temple pond of Bunhwangsa Temple. Considering the unique characteristic of the garden pond that it is divided into two periods, it was interpreted that it would have functioned as a ritual facility related to Ryong (oriental dragon) belief in the 6th to 7th centuries, the first period, and as a garden pond with enhanced landscaping functions in the 8th to 9th centuries, the second period. In addition, it is highly probable that it was the site of Cheongyeongung Palace (青淵宮) and Jochujeong Pavilion (造秋亭) mentioned in the literature records. The "ㄹ"- shaped waterway, a characteristic facility of the first period, was found; however, considering its width and depth, it is insufficient to conclude that it was a simple drainage facility. Rather, it is more likely that it functioned as a passageway for the conceptual entry of Ryong during Ryong rituals. Furthermore, some have suggested that it may have been a ceremony-related Yusang-goksu (流觴曲水) facility. These facilities related to Ryong rituals were reorganized in the second period. Specifically, the nature of the garden pond was changed centered on the landscaping function in connection with the addition of a curved revetment, garden stone, and pavilion buildings, and the dismantlement of the "ㄹ"-shaped waterway and hexagonal building. As for nature, it can be regarded as a royal facility in terms of decorative elements including the ritual function of the first period and the gwimyeonwa (ghost face tiles) of the second period. Judging from the fact that the upper part of the embankment adjacent to the west side of the site was removed, it is very apparent that the main building was located on the upper part of the embankment. There would not have been a large-scale building site because it served the functions of ritual and recreation, rather than being the residence of the king.

An Automated OpenGIS-based Tool Development for Flood Inundation Mapping and its Applications in Jeju Hancheon (OpenGIS 기반 홍수범람지도 작성 자동화 툴 개발 및 제주 한천 적용 연구)

  • Kim, Kyungdong;Kim, Taeeun;Kim, Dongsu;Yang, Sungkee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.691-702
    • /
    • 2019
  • Flood inundation map has various important roles in terms of municipal planning, timely dam operation, economic levee design, and building flood forecasting systems. Considering that the riparian areas adjacent to national rivers with high potential flood vulnerability conventionally imposed special cares to justify applications of recently available two- or three-dimensional flood inundation numerical models on top of digital elevation models of dense spatial resolution such as LiDAR irrespective of their high costs. On the contrary, local streams usually could not have benefits from recent technological advances, instead they inevitably have relied upon time-consuming manual drawings or have accepted DEMs with poor resolutions or inaccurate 1D numerical models for producing inundation maps due mainly to limited budgets and suitable techniques. In order to efficiently and cost-effectively provide a series of flood inundation maps dedicatedly for the local streams, this study proposed an OpenGIS-based flood mapping tool named Open Flood Mapper (OFM). The spatial accuracy of flood inundation map derived from the OFM was validated throughout comparison with an inundation trace map acquired after typhoon Nari in Hancheon basin located in Jeju Island. Also, a series of inundation maps from the OFM were comprehensively investigated to track the burst of flood in the extreme flood events.

Performance Analysis of Photovoltaic Power Generator by Usage Battery Charge (축전지 사용 유무에 따른 태양광발전기의 성능 분석)

  • Yun, Sung Wook;Choi, Man Kwon;Kim, Hyeon Tae;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.220-227
    • /
    • 2013
  • This study examined the electric power quantity derived from solar radiation after installing a photovoltaic power generation system on the rooftop of building adjacent to a greenhouse with a view to reducing the operating expenses of the greenhouse by securing electric energy required to run it. Results of the study can be summed up as follows: The maximum, mean, and minimum solar radiation on the horizontal plane was $26.1MJ{\cdot}m^{-2}$, $14,0MJ{\cdot}m^{-2}$, and $0.6MJ{\cdot}m^{-2}$, respectively and individual the daily electric energy generated was about 6.1 kWh, 3.7 kWh, and 0.01 kWh. The cumulative total amounts of solar radiation and electric energy was about $4,378.2MJ{\cdot}m^{-2}$ and 1,163.2 kWh, respectively. Maximum, mean and minimum cumulative electric energy consumed through each load respectively was 4.5 kWh, 2.4 kWh, and 0.0 kWh and the cumulative electric energy were 739.2 kWh, which accounted for about 63.5% of generated power. In case of the mean amount of power consumption of the system used for this study, the small capacity of heater and the short operating hours meant there was enough power; while big capacity of heater led to a shortage, and if the array surface temperature increased relatively, the energy became proportionate to solar radiation and generated power does not increase. The correlation coefficient between the two factors was 0.851, which indicates a high correlation coefficient.

Experimental study on the tunnel behavior induced by the excavation and the structure construction above existing tunnel (기존터널 상부지반 굴착 후 구조물 설치에 따른 터널거동에 관한 실험적 연구)

  • Cha, Seok-Kyu;Lee, Sangduk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.3
    • /
    • pp.640-655
    • /
    • 2018
  • Recently, the construction of the urban area has been rapidly increasing, and the excavation work of the ground has been frequently performed at the upper part of the existing underground structures. Especially, when the structure is constructed after the excavation of the ground, the loading and unloading process in the ground under the excavation basement can affect the existing underground structures. Therefore, in order to maintain the stability of the existing underground structure due to the excavation of the ground, it is necessary to accurately grasp the influence of the excavation and the structure load in the adjoining part. In this study, the effect of the excavation of the ground and the new structure load on the existing tunnel was experimentally implemented and the influence of the adjacent construction on the existing tunnel was investigated. For this purpose a large testing model with 1/5 scale of the actual size was manufactured. The influence of ground excavation, width of the load due to new structure, and distance between centers of tunnel and of excavation on the existing tunnel was investigated. In this study, it was confirmed that the influence on the existing tunnel gets larger, as the excavation depth get deeper. At the same distance, it was confirmed that the tunnel displacement increased up to three times according to the increase of the building load width. That is, the load width influences the existing tunnel larger than the excavation depth. As the impact of the distance between centers of tunnel and of excavation, it was confirmed that tunnel crown displacement decreased by 48%. The result showed that a tunnel is located in the range of 1D (D: tunnel diameter) from the center of excavation, the effect of excavation is the largest.

A Study on the Planning of In-Between Space Considering the Site Planning Characteristics of Elementary Schools -Focused on Newly-Built Elementary Schools in Sejong City- (초등학교 배치특성을 고려한 사이공간 계획방향에 관한 연구 -세종시 신설초등학교를 중심으로-)

  • Song, Byung-Ha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.105-116
    • /
    • 2018
  • This study started by examining 24 newly-built elementary schools in Sejong City with regard to their present conditions of in-between space. After categorizing the space according to its spatial composition, 5 schools were selected and analyzed in relation to the current status and frequency of use of their in-between space. Among the (other schools, the analysis gave the following results: 1) There was much higher usage of the in-between space for rest/play than for learning, which suggested that more rest/play area and apparatus should be provided. 2) Piloti areas were preferred, and a greater number of activities took place in these places than in the adjoining open areas. 3) When the in-between space was combined with a passage (as in the case of E2 and E3), a separation must be provided in order not to interfere with the rest/play activities. 4) In planning the in-between space, priority should be given to activities over landscape purposes. 5) Diverse and easy access to the space must be planned, particularly as the main entrance is not directly connected to the space. Entry at the end of an adjacent building could be a possible solution.

Estimation of Appropriate Infiltration Rate and the Effects of the Flowerbed Type Infiltration System (화단형 침투시설의 단위설계침투량 산정 및 효과분석)

  • Han, Young-Hae;Lee, Tae-Goo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.140-147
    • /
    • 2012
  • This study developed a flowerbed type infiltration system that could control the amount of runoff discharge under a certain level estimated its proper design infiltration rate, and analyzed the effects of its implementation. Analyzing the performance of infiltration system is the one of the essential processes that should be under review to predict its effects after implementation when a rainwater infiltration system is included in a district-based plan. To estimate the unit design infiltration rate of this system, the runoff decrease effect was analyzed by varying the unit infiltration rate of the system applied to the parking lot adjacent to the Korea Institute of Construction Technology laboratory building by using a water balance analysis program. After varying the unit design infiltration to $0.1{\sim}3m^3/m^2.day$ to analyze the variation in the rate of runoff, 80% of the runoff was infiltrated at $1.0m^3/m^2.day$, and the unit infiltration design rate at the time was 0.0416(m3/m2.hr). It was also found that the unit design infiltration rate obtained from a field infiltration test of the developed system was about $0.045m^3/hr$. Based on this study, it was possible that infiltration rate is estimated to consider the economic scale and environmental effect. It is significant to apply the spatial plan of rainwater infiltration system as green infrastructure.

A Study on the Change of Tensile Force of Friction Type Anchor under Shear Deformation of Ground (지반의 전단변형에 따른 마찰형 앵커의 긴장력 변화에 대한 연구)

  • You, Min-Ku;Kwon, O-Il;Lee, Sang-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.4
    • /
    • pp.13-25
    • /
    • 2018
  • When deformation occurs on slope reinforced with anchor, shear stress and bending stress are applied on the shear surface along the slip surface and increase of the shear deformation causes the tension force variation of the anchor. In this study, shear test was performed by measuring the tension force of the anchor by inducing shear deformation in vertical direction of the anchor using a large-scale direct shear test equipment in order to confirm the tension force variation of the anchor induced by shear deformation. The shear test was performed for 8 conditions which were classified according to the anchor reinforcement, separation distance (1D, 2D, 4D) from the shear surface to bonded part and the lateral-pressure condition (0.1 MPa, 0.2 MPa) of adjacent ground. As a result of the shear test, it was found that the separation distance and the lateral-pressure condition affect the shear force of the ground reinforced by anchor and the tension force of the anchor, and experimentally verified that the shear force variation is related to axial force variation of the anchor head and tip. Therefore, it was confirmed that the behavior of the bonded part induced by the shear deformation can be indirectly predicted by analyzing the tendency of the tension force variation of the anchor head.