• 제목/요약/키워드: acrylic resins

검색결과 135건 처리시간 0.02초

Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture

  • Jang, Dae-Eun;Lee, Ji-Young;Jang, Hyun-Seon;Lee, Jang-Jae;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.278-287
    • /
    • 2015
  • PURPOSE. The aim of this study was to compare the color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for the non-metal clasp dentures to those of thermoplastic polyamide and conventional heat-polymerized denture base resins. MATERIALS AND METHODS. Three types of denture base resin, which are conventional heat-polymerized acrylic resin (Paladent 20), thermoplastic polyamide resin (Bio Tone), thermoplastic acrylic resin (Acrytone) were used as materials for this study. One hundred five specimens were fabricated. For the color stability test, specimens were immersed in the coffee and green tee for 1 and 8 weeks. Color change was measured by spectrometer. Water sorption was tested after 1 and 8 weeks immersion in the water. For the test of cytotoxicity, cell viability assay was measured and cell attachment was analyzed by FE-SEM. RESULTS. All types of denture base resin showed color changes after 1 and 8 weeks immersion. However, there was no significant difference between denture base resins. All specimens showed significant color changes in the coffee than green tee. In water sorption test, thermoplastic acrylic resin showed lower values than conventional heat-polymerized acrylic resin and thermoplastic polyamide resin. Three types of denture base showed low cytotoxicity in cell viability assay. Thermoplastic acrylic resin showed the similar cell attachment but more stable attachment than conventional heat-polymerized acrylic resin. CONCLUSION. Thermoplastic acrylic resin for the non-metal clasp denture showed acceptable color stability, water sorption and cytotoxicity. To verify the long stability in the mouth, additional in vitro studies are needed.

Acetoacetoxy기 함유 하이솔리드 도료용 아크릴 수지의 합성 (Synthesis of Acrylic Resins for High-Solid Coatings Containing Acetoacetoxy Group)

  • 유혁재;정동진;정충호;함현식;박홍수;김태옥
    • 한국응용과학기술학회지
    • /
    • 제20권3호
    • /
    • pp.221-229
    • /
    • 2003
  • A copolymer ${\sim}$550cps ; $M_n$, 2590${\sim}$2850 ; and conversion, 82${\sim}$89%, respectively. It was found from the plotting of $T_g$ versus viscosity and $T_g$ versus molecular weight that viscosity increased with $T_g$ while number averaged molecular weight decreased with increasing $T_g$.

Caprolactone기 함유 아크릴수지와 HDI-Trimer에 의한 하이솔리드 도료의 도막물성 (Physical Properties of High-Solid Coatings with Acrylic Resins Containing Caprolactone Group and HDI-Trimer)

  • 조혜진;심일우;유혁재;우종표;김명수;함현식;박홍수;백운필
    • 한국응용과학기술학회지
    • /
    • 제21권4호
    • /
    • pp.300-305
    • /
    • 2004
  • High-solid coatings were prepared by blending of previosly synthesized acrylic resins and hexamethylene diisocyanate-trimer and curing it at room temperature. The characterization of the films of the prepared coatings was performed. The impact resistance, cross-hatch adhesion, $60^{\circ}$specular gloss, and heat resistance of the films proved to be good, and the pencil hardness and drying time proved to be slightly poor. Especially, there was a remarkable improvement in the heat resistance. This improvement may stem from the regular arrangement of ethyl groups introduced into the acrylic resin. As a result of Rigid-body pendulum visco-elasticity measurement, dynamic $T_g$ values of cured films increased with dynamic $T_g$ values.

열중합(熱重合) 의치상(義齒床) Resin과 합성수지인공치(合成樹脂人工齒)의 결합강도(結合强度)에 관(關)한 연구(硏究) (Bonding of acrylic resin teeth to hear-cured denture base resins)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제8권1호
    • /
    • pp.23-29
    • /
    • 1986
  • One of the primary advantage of acrylic resin teeth is their ability to bond chemically to the denture base resins. But, occasionally, failure have been observed in which acrylic resin teeth break lose from the denture, indicating that chemical bonding does not always occur. The most probable explanation for this type of failure was the presence of a trace of wax remaining as a residue on the surfaces of the teeth after the boiling-out procedure which adgered to the tooth surface and prevented bonding. The purpose of this stdy was preparing the specimens of denture base resin with acrylic resin teeth that four treatment method to ridge lap portion of the tooth and investigated bond between the teeth and denture base resin with tensile strength. Compared results of tensile strength on test specimens were as follows: 1. The mean of strength among the four test groups showed the difference was significant enough(P 0.01). The order of its strength mean was methylene chloride treatment group, detergent solution treatment group, kerosene-ether treatment grgoup, boiling water only group. 2. In compared results between the wax eliminating method groups, there were significant difference between the boiling water only group and other groups(P 0.01), no significant difference were found in the wax eliminating method groups except boiling water only group(P 0.05).

  • PDF

카프로락톤기 함유 90% 고형분인 아크릴수지의 하이솔리드 도료에의 적용 (Application of Acrylic Resins Containing Caprolactone Group and 90% Solid Contents to High-Solid Coatings)

  • 박홍수;양인모;김승진;김영근;정충호
    • 한국응용과학기술학회지
    • /
    • 제24권2호
    • /
    • pp.149-159
    • /
    • 2007
  • In order to prepare high-solid coatings, acrylic resins, HSCs [poly (EA/EMA/2-HEMA/CLA)] that contain 90% solid, were synthesized by copolymerization of ethyl acrylate (EA), ethyl methacrylate (EMA), 2-hydroxyethyl methacrylate (2-HEMA) and caprolactone acrylate (CLA). The high-solid coatings named as CHSCs (HSCs/HDI-trimer) were prepared by the curing reaction between the acrylic resins containing 90% solid contents and the isocyanates (HDI-trimer) curing agent room temperature. The curing behavior and various properties were examined on the film coated with the both high-solid coatings. The glass transition temperatures $(T_g)$ of CHSCs increased proportionally with increasing the predicted $T_g$ value by Fox equation, and had nothing to do with the solid contents. The prepared film showed good properties for $60^{\circ}$ specular gloss, impact resistance, cross-hatch adhesion and heat resistance, and bad properties for pencil hardness, drying time, and pot-life. Among the film properties, the heat resistance was very excellent and could be explained by the introduction of functional monomers of CLA.

중합방법이 다른 의치상 이장용레진의 물리적 특성 (PHYSICAL PROPERTIES OF RELINING DENTURE BASE RESINS WITH DIFFERENT POLYMERIZING METHODS)

  • 조석규;송광엽;윤수연;김문영
    • 대한치과보철학회지
    • /
    • 제40권4호
    • /
    • pp.386-395
    • /
    • 2002
  • This study would like to measure and compare water sorption and solubility of acrylic resins, with 3 different polymerizing methods, and tensile strength between denture base resin and relining rosins. For this experiment, 3 different acrylic resins were used; heat polymerizing resin: Vertex (Dentmex, Zeist, Holland), autopolymerizing resin: Tokuso Rebase (Tokuyama Corp, Tokyo, Japan), and light curing resin: Mild Rebaron LC(GC Corp, Tokyo, Japan) The results were as follows ; 1. Tokuso Rebase showed the lowest water sorption. followed by Mild Rebaron LC and Vertex. Among resins, there were some signigicant differences (P<0.05). 2. Vertex showed the lowest solubility, followed by Mild Rebaron LC and Tokuso Rcbase. Among resins, there were some signigicant differences (P<0.05). 3. Intact Vertex showed the highest tensile strength, and Mild Rebaron LC had a more tensile strength than Tokuso Rebase. Between Vertex and the other resins, there were some signigicant differences (P<0.05) However, between Mild Rebaron LC and Tokuso Rebase, there was no statistical difference (P>0.05). About 50% of Rebaron LC showed cohesive fracture. 4. Tensile strength has more decreased after thermocycling than before, but there was no statistical difference (P>0.05).

Influence of ozone and paracetic acid disinfection on adhesion of resilient liners to acrylic resin

  • Ekren, Orhun;Ozkomur, Ahmet
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.290-295
    • /
    • 2016
  • PURPOSE. The aim of this study was to evaluate the effect of paracetic acid (PAA) and ozone disinfection on the tensile bond strength (TBS) of silicone-based resilient liners to acrylic resins. MATERIALS AND METHODS. One hundred and twenty dumbbell shaped heat-polymerized acrylic resins were prepared. From the mid segment of the specimens, 3 mm of acrylic were grinded off and separated parts were reattached by resilient liners. The specimens were divided into 2 control (control1, control7) and 4 test groups of PAA and ozone disinfection (PAA1, PAA7, ozone1 and ozone7; n=10). While control groups were immersed in distilled water for 10 min (control1) and 7 days (control7), test groups were subjected to PAA (16 g/L) or ozone rich water (4 mg/L) for 1 cycle (10 min for PAA and 60 min for ozone) per day for 7 days prior to tensile tests. Measurements of the TBS were analyzed using 3-way ANOVA and Tukey's HSD test. RESULTS. Adhesive strength of Mollosil decreased significantly by application of ozone disinfection. PAA disinfection had no negative effect on the TBS values of Mollosil and Molloplast B to acrylic resin. Single application of ozone disinfection did not have any negative effect on TBS values of Molloplast B, but prolonged exposure to ozone decreased its adhesive strength. CONCLUSION. The adhesion of resilient liners to acrylic was not adversely affected by PAA disinfection. Immersion in ozonated water significantly decreased TBS of Mollosil. Prolonged exposure to ozone negatively affects adhesion of Molloplast B to denture base materials.

소르빅산 변성 수소첨가 DCPD계 석유수지의 합성 및 응용 (Synthesis and Application of Sorbic Acid Grafted Hydrogenated Dicyclopentadiene Hydrocarbon Resin)

  • 공원석;박준효;윤호규;이재욱
    • 접착 및 계면
    • /
    • 제16권1호
    • /
    • pp.29-34
    • /
    • 2015
  • 석유수지는 분자량이 작고 무정형인 열가소성 수지로써 다양한 접착제 및 고무의 가공조제, 필름의 첨가제 등으로 사용되고 있다. 석유수지의 단점은 비극성이기 때문에 비극성의 폴리머와의 상용성은 우수하나 아크릴 및 우레탄, 폴리아마이드와 같은 극성기를 포함하는 폴리머와의 상용성은 좋지 않다. 그뿐만 아니라, 최근 석유수지의 원료로 사용되는 나프타 크래킹 공정에서 나오는 부산물의 양이 가스 크래킹의 확대 적용으로 인해 줄어들고 있는 상황이다. 이러한 문제를 해결하기 위해 본 연구에서는 석유수지 원료로 극성기를 포함하면서 지속 가능한 신규 원료인 소르빅산으로 일부 대체하고자 하였다. 기존 석유수지 원료인 DCPD 모노머와 블루베리로부터 생성되는 소르빅산은 열중합에 의해 Diels-Alder 반응으로 성공적으로 공중합하였다. 소르빅산 변성 수소첨가 DCDPD계 석유수지는 아크릴계 접착제 배합에 적용되어 다양한 점 접착 물성이 측정되었으며, Polarity에 따른 상용성 및 연화점에 따라 최적 물성이 결정되었다.

의치 수리용 레진의 색안정성과 결합강도에 관한 연구 (A STUDY ON THE COLOR STABILITY AND SHEAR BOND STRENGTH OF DENTURE REPAIR RESINS)

  • 진태호
    • 대한치과보철학회지
    • /
    • 제33권1호
    • /
    • pp.24-31
    • /
    • 1995
  • This study was performed to investigate the color stability and shear bond strength of denture repair resins. The denture base resins used in this study were Premium Super-20(Lang Dental Mfg. Co., Inc.,.U.S.A.) as heat curing resin, Triad VLC Denture Base(Dentsply/York Division, U.S.A.), Triad Reline Material(Dentsply/York Division, U.S.A.), Repair Acrylic(Lang Dental Mfg. Co., Inc.,. U.S.A.), Toughron Rebase (MikiChemical Product, Kyoto, Japan), and Tokuso Rebase(Tokuyama Soda Co., Ltd., Japan) as denture repair resin. After fabrication of specimens, they stored for 20 months, then color changes and shear bond strength were measured by colorimeter(Model TC-6FX, Tokyo Denshoku Co.) and Instron Universial Test Machine. The results were as follows : 1. There were changes of $L^{\ast},\;a^{\ast},\;b^{\ast}$ and $DE^{\ast}$ in Triad VLC Denture Base after 20 months. 2. There were changes of $a^{\ast}$ in Toughron Rebase and Tokuso Rebase, and $b^{\ast}$ in Tokuso Rebase after 20 months. 3. The shear bond strength of Repair Acrylic and Toughron Rebase were higher than that of Tokuso Rebase and Triad Reline Material.

  • PDF

환경친화성 하이솔리드 도료의 제조 및 고형분 함량에 따른 도막물성 변화 (Preparation of Environmental Friendly High-Solid Coatings and Their Property Changes with Solid Contents)

  • 박홍수;조혜진;심일우;유혁제;김영찬
    • 한국응용과학기술학회지
    • /
    • 제22권2호
    • /
    • pp.116-122
    • /
    • 2005
  • Room temperature cure type of acryl-urethane coatings with high solid content were prepared in this study. Acrylic resins with 80% solid content were cured with hexamethylene diisocyanate (Desmodure N-3600). The cure time of prepared coatings BEHCC-84 (BEHC-84 : $T_g=0^{\circ}C$) and BEHCC-87 (BEHC-87 : $T_g=30^{\circ}C$), measured by rigid-body pendulum method, was recorded 8.3 hours and 3.8 hours, respectively. Dynamic viscoelastic experiment also revealed the glass transition temperature of BEHCC-84 and BEHCC-87 to be $T_g=40.3^{\circ}C$ and $T_g=43.3^{\circ}C$, respectively. It was found that the adhesion and flexural properties among various propeties of coatings were enhanced by the incorporation of caprolactone acrylate monomer into the acrylic resins.