• Title/Summary/Keyword: acoustic axis

Search Result 119, Processing Time 0.028 seconds

An Experimental Evaluation of Mechanical Properties and Failure Processing in Composite Laminate (복합재료의 기계적 성질 및 파손과정 평가)

  • J.W.,Ong;K.H.,Song;R.W.,Sung;B.S.,Shim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.25 no.4
    • /
    • pp.58-68
    • /
    • 1988
  • This paper is concerned with mechanical properties of unidirectional laminate $[(0^{\circ})_{8T},\;(90^{\circ})_{8T}]$, composed of angle plies $[({\pm}15^{\circ})_{2S},\;({\pm}30^{\circ})_{2S},\;({\pm}45^{\circ})_{2S},\;({\pm}60^{\circ})_{2S},\;({\pm}75^{\circ})_{2S}$ and laminate $[(9^{\circ}/90^{\circ})_{2S},\;(90^{\circ}/{\pm}45^{\circ}/0^{\circ})_S,\;({\pm}45^{\circ}/0^{\circ}/{\pm}90^{\circ})_S,\;({\pm}45^{\circ}/90^{\circ}/0^{\circ})_S,\;(0^{\circ}/90^{\circ}/{\pm}45^{\circ})_S,\;(90^{\circ}/0^{\circ}/{\pm}45^{\circ})_S]$ under the condition of uniform strain tension. Also, experimental investigation was conducted $[10]_{8T}$, off-axis tensile test for intralaminar shear characterization. The experimental data on the failure criterion of tensor polynomial were compared with those from the classical laminate theory. Acoustic Emission experiments have been carried out to investigate the changes of the amplitude distributions of Acoustic Emission monitored during failure of tensile tests on Carbon/Epoxy composites.

  • PDF

A Study on the Strength Evaluation of Unidirectional Carbon Fiber Reinforced Plastics by Nondestructive Method (일방성(一方性) 복함재료(複合材料)의 파괴거동(破壞擧動) 및 강도평가(强度評價)에 관(關)한 연구(硏究))

  • Chang, H.K.;Lee, J.S.;Cho, K.S.;Lee, S.H.;Park, E.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.7 no.2
    • /
    • pp.42-47
    • /
    • 1988
  • The off-axis tensile strength of the unidirectional carbon fiber reinforced plastic and the residual strength of impact damaged CFRP were measured and compared with the stress wave factor (SWF) of the specimens. The SWF values were measured to be decreased with the strength reduction in both cases and found to be useful for the nondestructive strength evaluation of unidirectional CFRP. The failure behaviour of the unidirectional CFRP during off-axis tensile testing was also monitored by acoustic emission(AE) method. The AE energy release showed the characteristic feature depending on the off-axis angle and this result was analyzed to be caused by the difference of the expected failure mode depending on the off-axis angle. The failure mode of CFRP was found to be analyzed by investigation of the peak amplitude distribution of AE.

  • PDF

Measurement of Complex Modulus of Acoustic Materials by Using Transfer Function Method

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kang, Hyun-Joo;Kim, Bong-Ki;Kim, Sang-Ryul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.1E
    • /
    • pp.12-17
    • /
    • 2002
  • Two improvements are discussed in measurement of the complex Young's modulus of the acoustic materials by using the transfer function method. It is found that the accelerometer misalignment might result in the severe measurement error, particularly in high frequency range. The supporting structure is modified to attach the upper and lower accelerometers along the vertical axis. Secondly, the method fur solving the equation associated with wave model is described. The solution of the lumped mass-spring model is chosen as the starting value for low frequency range, while in the mid and high frequency, the solution to the previous frequency step is used as the initial values. Measurements are done for hard and soft rubber specimens. It is shown that the erroneous peaks in the transfer function, due to the measurement error, cause highly incorrect Young's modulus and loss factors.

FBAR Device with Thin AlN Piezoelectric Film for 2 GHz RF Bandpass Filter Applications (2 GHz 대역 RF 대역통과 필터 응용을 위한 AlN 압전 박막을 이용한 FBAR 소자)

  • Giwan Yoon;Munhyuk Yim;Dongkyu Chai;Kim, Sanghee;Kim, Jongheon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.2
    • /
    • pp.250-254
    • /
    • 2003
  • A film bulk acoustic resonator (FBAR) device for 2 GHz radio frequency (RF) bandpass filter application is presented. This FBAR device consists of an aluminum nitride (AlN) film sandwiched between top(Al) and bottom(Au) electrodes and an acoustic multilayer reflector of a silicon dioxide/tungsten (SiO2/W). The A/N film deposited using a RF sputtering was observed to have small columnar grains with a strongly preferred orientation towards c axis. In addition to a high quality factor (4300), a large return loss of 37.19 dB was obtained.

Characteristics of ZnO Thin Films of FBAR using ALD and RF Magnetron Sputtering (ALD와 RF 마그네트론 스퍼터링을 이용한 FBAR 소자의 ZnO 박막증착 및 특성)

  • Shin, Young-Hwa;Kwon, Sang-Jik;Yoon, Young-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.2
    • /
    • pp.164-168
    • /
    • 2005
  • Piezoelectric ZnO thin films were for the first time formed on SiO$_2$/Si(100) substrate using 2-step deposition, atomic layer deposition(ALD) and RF magnetron sputtering deposition, for film bulk acoustic resonator(FBAR) applications. The ZnO buffer layer by ALD was deposited using alternating diethyl zinc(DEZn)/$H_2O$ exposures and ultrahigh purity argon gas for purging. The ZnO films by 2-step deposition revealed stronger c-axis-preferred orientation and smoother surface than those by the conventional RF sputtering method. The solidly mounted resonator(SMR)-typed FBAR fabricated by using 2-step deposition method revealed higher quality factor of 580 and lower return loss of -17.35dB. Therefore the 2-step deposition method in this study could be applied to the FBAR device fabrication.

Verification and application of Target Strength for Japanese anchovy (Engraulis japonicas) by theoretical acoustic scattering model (이론모델을 이용한 멸치의 음향산란강도의 검토 및 적용)

  • Hwang, Kangseok;Lee, Kyounghoon;Hwang, Bo-Kyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.4
    • /
    • pp.487-494
    • /
    • 2012
  • Acoustical backscattering characteristics of Japanese anchovy can be estimated by Kirchhoffray mode model (KRM model) due to estimate exact body and swim-bladder shape of the fish, the samples were rapidly frozen by dry-ice and alcohol. X-ray photos for ventral and lateral direction for 6 samples were taken and the 3D coordinates of the body swim-bladder were estimated by digitizing from the photos. The angles between the axis of body and swim-bladder were about $9^{\circ}$ at 38kHz and $7^{\circ}$ at 120kHz, 200kHz. General formula of TS and BL estimated were < $TS_{38kHz}$ >=20logBL-67.3, < $TS_{120kHz}$ >=20logBL-66.6, < $TS_{200kHz}$ >=20logBL-67.0. As a result, we confirmed KRM model is very useful to estimate TS (Target Strength) for design of experiment and it also can be applied to estimate the abundance of Japanese anchovy distributed by 2 frequency difference method in the survey area.

The Bearing Estimation of Narrowband Acoustic Signals Using DIFAR Beamforming Algorithm (DIFAR 빔형성 알고리듬을 이용한 협대역 음향신호의 방향성 추정)

  • 장덕홍;박홍배;정문섭;김인수
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.169-184
    • /
    • 2002
  • In order to extract bearing information from the directional sensors of DIFAR(directional frequency analysis and recording) that is a kind of passive sonobuoy, the cardioid beamforming algorithm applicable to DIFAR system was studied in the frequency domain. the algorithm uses narrow-band signals propagated though the media from the acoustic sources such as ship machineries. The proposed algorithm is expected to give signal to noise ratio of 6dB when it uses the maximum response axis(MRA) among the Cardioid beams. The estimated bearings agree very well with those from GPS data. Assuming the bearings from GPS data to be real values, the estimation errors are analyzed statistically. The histogram of estimation errors in each frequency have Gaussian shape, the mean and standard deviation dropping in the ranges -1.1~$6.7^{\circ}$ and 13.3~$43.6^{\circ}$, respectively. Estimation errors are caused by SMR degradation due to propagation loss between the source and receiver, daily fluctuating geo-magnetic fields, and non-stationary background noises. If multiple DIFAR systems are employed, in addition to bearing, range information could be estimated and finally localization or tracking of a target is possible.

Quasi-Optimal DOA Estimation Scheme for Gimbaled Ultrasonic Moving Source Tracker (김발형 초음파 이동음원 추적센서 개발을 위한 의사최적 도래각 추정기법)

  • Han, Seul-Ki;Lee, Hye-Kyung;Ra, Won-Sang;Park, Jin-Bae;Lim, Jae-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.276-283
    • /
    • 2012
  • In this paper, a practical quasi-optimal DOA(direction of arrival) estimator is proposed in order to develop a one-axis gimbaled ultrasonic source tracker for mobile robot applications. With help of the gimbal structure, the ultrasonic moving source tracking problem can be simply reduced to the DOA estimation. The DOA estimation is known as one of the representative long-pending nonlinear filtering problems, but the conventional nonlinear filters might be restrictive in many actual situations because it cannot guarantee the reliable performance due to the use of nonlinear signal model. This motivates us to reformulate the DOA estimation problem in the linear robust state estimation setting. Based on the assumption that the received ultrasonic signals are noisy sinusoids satisfying linear prediction property, a linear uncertain measurement model is newly derived. To avoid the DOA estimation performance degradation caused by the stochastic parameter uncertainty contained in the linear measurement model, the recently developed NCRKF (non-conservative robust Kalman filter) scheme [1] is utilized. The proposed linear DOA estimator provides excellent DOA estimation performance and it is suitable for real-time implementation for its linear recursive filter structure. The effectiveness of the suggested DOA estimation scheme is demonstrated through simulations and experiments.

On the Beam Focusing Behavior of Time Reversed Ultrasonic Arrays Using a Multi-Gaussian Beam Model

  • Jeong, Hyun-Jo;Lee, Jeong-Sik;Jeong, Yon-Ho;Bae, Sung-Min
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.531-537
    • /
    • 2008
  • One of the fundamental features of time reversal acoustic (TRA) techniques is the ability to focus the propagating ultrasonic beam to a specific point within the test material. Therefore, it is important to understand the focusing properties of a TR device in many applications including nondestructive testing. In this paper, we employ an analytical scheme for the analysis of TR beam focusing in a homogeneous medium. More specifically, a nonparaxial multi-Gaussian beam (NMGB) model is used to simulate the focusing behavior of array transducers composed of multiple rectangular elements. The NMGB model is found to generate accurate beam fields beyond the nonparaxial region. Two different simulation cases are considered here for the focal points specified on and off from the central axis of the array transducer. The simulation results show that the focal spot size increases with increasing focal length and focal angle. Furthermore, the maximum velocity amplitude does not always coincide with the specified focal point. Simulation results for the off-axis focusing cases do demonstrate the accurate steering capability of the TR focusing.

A Study on Attitude Heading Reference System Based Micro Machined Electro Mechanical System for Small Military Unmanned Underwater Vehicle

  • Hwang, A-Rom;Yoon, Seon-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.522-526
    • /
    • 2015
  • Generally, underwater unmanned vehicle have adopted an inertial navigation system (INS), dead reckoning (DR), acoustic navigation and geophysical navigation techniques as the navigation method because GPS does not work in deep underwater environment. Even if the tactical inertial sensor can provide very detail measurement during long operation time, it is not suitable to use the tactical inertial sensor for small size and low cost UUV because the tactical inertial sensor is expensive and large. One alternative to INS is attitude heading reference system (AHRS) with the micro-machined electro mechanical system (MEMS) inertial sensor because of MEMS inertial sensor's small size and low power requirement. A cost effective and small size attitude heading reference system (AHRS) which incorporates measurements from 3-axis micro-machined electro mechanical system (MEMS) gyroscopes, accelerometers, and 3-axis magnetometers has been developed to provide a complete attitude solution for UUV. The AHRS based MEMS overcome many problems that have inhibited the adoption of inertial system for small UUV such as cost, size and power consumption. Several evaluation experiments were carried out for the validation of the developed AHRS's function and these experiments results are presented. Experiments results prove the fact that the developed MEMS AHRS satisfied the required specification.