• Title/Summary/Keyword: accelerated stress test

Search Result 295, Processing Time 0.021 seconds

Evaluation Criteria of Reliability on Transmission Control Unit for Passenger Car

  • Choi, M.;Ryu, S.;Lim, J.H.;Jeong, H.S.
    • International Journal of Reliability and Applications
    • /
    • v.11 no.1
    • /
    • pp.55-67
    • /
    • 2010
  • There has been a recent upsurge in demand for the improvement of car reliability in the Northern American which is the primary market of South Korea automobile industry. It has been required that the warranty for transmission control unit for passenger cars directly related to passenger safety or security should be extended for 10 years and 160,000 km. In this paper, the test method for reliability and evaluation criteria is presented to evaluate the reliability on the automatic transmission controller. Reliability certification test can be roughly divided into two types: a quality test and life assessment test and a quality test can be subdivided into a basic performance test and environmental resistance test. There are 3 types of tests on the performance test for automatic transmission controller and environmental resistance test is composed of 14 items. Life test is performed with only the product passed this quality test. In this study, operation limit test at the high-temperatures, accelerated life test under specific temperature and accelerated life test for 2 or 3 stress levels are shown as a way for life test.

  • PDF

Assessment of flow-accelerated corrosion-induced wall thinning in SA106 pipes with elbow sections

  • Seongin Moon;Jong Yeon Lee;Kyung-Mo Kim;Soon-Woo Han;Gyeong-Geun Lee;Wan-Young Maeng;Sebeom Oh;Dong-Jin Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1244-1249
    • /
    • 2024
  • A combination of flow-accelerated corrosion (FAC) tests and corresponding computational fluid dynamics (CFD) tests were performed to determine the hydrodynamic parameters that could help predict the highly susceptible location to FAC in the elbow section. The accelerated FAC tests were performed on a specimen containing elbow sections fabricated using commercial 2-inch carbon steel pipe. The tests were conducted at flow rates of 9 m/s under the following conditions: water temperature of 150 ℃, dissolved oxygen <5 ppb, and pH 7. Thickness reduction of the specimen pipe due to FAC was measured using ultrasonic testing. CFD was conducted on the FAC test specimen, and the turbulence intensity, and shear stress were analyzed. Notably, the location of the maximum hydrodynamic parameters, that is, the wall shear stress and turbulent intensity, is also the same location with maximum FAC rate. Therefore, the shear stress and turbulence intensity can be used as hydrodynamic parameters that help predict the FAC-induced wall-thinning rate. The results provide a method to identify locations susceptible to FAC and can be useful for determining inspection priority in piping systems.

A Study on Goodness of Fit Test in Accelerated Life Tests (가속수명시험에 대한 적합도 검정에 관한 연구)

  • Lee, Woo-Dong;Cho, Geon-Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • v.7 no.1
    • /
    • pp.37-46
    • /
    • 1996
  • In this paper, we introduce the goodness of fit test procedure for lifetime distribution using step stress accelerated lifetime data. Using the nonpapametric estimate of acceleration factor, we prove the strong consistence of empirical distribution function under null hypothesis. The critical vailues of Kolmogorov-Smirnov, Anderson-Darling, Cramer-von Mises statistics are computed when the lifetime distibution is assumed to be exponential and Weibull. The power of test statistics are compared through Monte-Cairo simulation study.

  • PDF

Accelerated Lifetime Data Analysis Using Quantile Regression (분위수 회귀를 이용한 가속수명시험 자료 분석)

  • Roh, Chee-Youn;Kim, Hee-Jeong;Na, Myung-Hwan
    • The Korean Journal of Applied Statistics
    • /
    • v.21 no.4
    • /
    • pp.631-638
    • /
    • 2008
  • Accelerated Lifetime Test is a method of estimation of lifetime quality characteristics under operation condition with the accelerated lifetime data obtained under accelerated stress. In this paper we propose estimation method with accelerated lifetime data using quantile regression. We apply the method to real data with Arrhenius and Inverse power model.

Optimal step stress accelerated life tests for the exponential distribution under periodic inspection and type I censoring

  • Moon, Gyoung-Ae;Park, Yong-Kil
    • Journal of the Korean Data and Information Science Society
    • /
    • v.20 no.6
    • /
    • pp.1169-1175
    • /
    • 2009
  • In this paper, the inferences of data obtained from periodic inspection and type I censoring for the step-stress accelerated life test are studied. The exponential distribution with a failure rate function that a log-linear function of stress and the tampered failure rate model are considered. The maximum likelihood estimators of the model parameters are estimated and also the optimal stress change time which minimize the asymptotic variance of maximum likelihood estimators of parameters is determined. A numerical example will be given to illustrate the proposed inferential procedures and the sensitivity of the asymptotic variance of the estimated mean by the guessed parameters is investigated.

  • PDF

Development of Accelerated Failure-free Test Method for Automotive Alternator Magnet (자동차 교류발전기용 자석에 대한 가속 무고장시험방법 개발)

  • Liu, Qiang;Ismail, Azianti;Jung, Won
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.36 no.4
    • /
    • pp.92-99
    • /
    • 2013
  • Many automotive components for power generation such as motors and alternators have been widely using ferrite magnets. To ensure a high level of efficiency could be achieved in an alternator, the assembled magnets must be in good enough durability. Recently, some hairline cracks have been found on the magnet produced by manufacturers in Korea. Thus, there is an increasing concern that some of the magnets produced could cause further problems after being assembled in the alternator. Based on the standard alternator test (RS0008 : 2006), this paper has developed an accelerated failure-free test for magnets in alternator to demonstrate that assembled magnets will meet durability objective specified by the manufacturer. This guarantees the target life of the magnet with 90 percent reliability and 90 percent confidence level (R90C90). Temperature and rotation speed were selected as accelerated stress factors.

An objective Bayesian analysis for multiple step stress accelerated life tests

  • Kim, Dal-Ho;Kang, Sang-Gil;Lee, Woo-Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.20 no.3
    • /
    • pp.601-614
    • /
    • 2009
  • This paper derives noninformative priors for scale parameter of exponential distribution when the data are collected in multiple step stress accelerated life tests. We nd the objective priors for this model and show that the reference prior satisfies first order matching criterion. Also, we show that there exists no second order matching prior. Some simulation results are given and using artificial data, we perform Bayesian analysis for proposed priors.

  • PDF

Durability of MEA Using sPEEK Membrane Reinforced with Poly Imide in PEMFC (고분자전해질연료전지에서 폴리이미드 강화 sPEEK막 MEA의 내구성)

  • Lee, Hye-Ri;Na, Il-Chai;Oh, Sung-Jun;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.296-301
    • /
    • 2017
  • Recently, there are many efforts focused on development of more economical non-fluorinated membranes for PEMFCs (Proton Exchange Membrane Fuel Cells). In this study, sulfonated poly (ether ether ketone) (sPEEK) membrane reinforced with poly imide was made to enhance of membrane durability. In order to test durability of single (un-reinforced) membrane and reinforced membrane MEA (Membrane and Electrode Assembly), degradation accelerated stress test was used. Before and after degradation, I-V polarization curve, hydrogen crossover current, electrochemical surface area, membrane resistance and charge transfer resistance were measured. As a result of experiments, hydrogen crossover current of reinforced MEA was lower than that of single MEA, therefor durability of reinforced MEA was higher than that of single MEA. There was not especially short phenomena in reinforced MEA after degradation accelerated stress test.

Assessment of Seed Viability and Vigour in Neem (Azadirachta indica A. Juss.)

  • Kumar, Devendra
    • Journal of Forest and Environmental Science
    • /
    • v.29 no.4
    • /
    • pp.282-291
    • /
    • 2013
  • Rapid loss in viability of neem (Azadirachta indica A. Juss.) seed is a major problem. Present effort was undertaken for developing a set pattern for assessing of viability and vigour in seed of various mother tree age of neem (Age I-06 years, Age II-15 years, Age III-25 years and Age IV->30 years old). Various viability test viz. triphenyle tetrazolium chloride test, electrical conductivity, excised embryo test, and germination test have been performed on seeds obtained from mother tree age classes. Inconsistency was observed with the TTC and EC test in germination of seed in laboratory as well as nursery. While various vigour tests viz. cold test, chemical stress test (methanol stress test), and accelerated ageing test alongwith ageing index, germination test (G%, MGT and GV) and various seedling growth parameters like seedling length (cm), number of leaves, collar diameter (cm), total biomass (g) alongwith mathematical indices i.e. vigour index, sturdiness quotient, volume index, quality index, root shoot ratio in nursery as well have been taken for study and showed better consistency. On the basis present study results of various viability and vigour test indicated that mother tree age class II performed better in comparison to others and it can be recommended for seed collection. Further it is also recommended that viability of neem seed may be assessed using various laboratory tests like excise embryo test and germination test (G%, MGT and GV) and vigour test may be taken preferably by cold germination test, chemical (methanol) stress test, accelerated ageing test in laboratory and germination alongwith various seedling growth parameters seedling length (cm), number of leaves, collar diameter (cm), total biomass (g) alongwith mathematical indices like Vigour Index, Sturdiness quotient, Volume Index, Quality index, root shoot ratio in nursery as discussed in this study.

Optimal Design of Accelerated Life Tests with Different Censoring Times

  • Seo, Sun-Keun;Kim, Kab-Seok
    • Journal of Korean Society for Quality Management
    • /
    • v.24 no.4
    • /
    • pp.44-58
    • /
    • 1996
  • This paper presents optimal accelerated life test plans with different censoring times for exponential, Weibull, and lognormal lifetime distributions, respectively. For an optimal plan, low stress level, proportion of test units allocated and censoring time at each stress are determined such that the asymptotic variance of the maximum likelihood estimator of a certain quantile at use condition is minimized. The proposed plans are compared with the corresponding optimal plans with a common censoring time over range of parameter values. Computational results indicate that those plans are statistically optimal ones in terms of accuracy of estimator when total censoring times of two plans are equal.

  • PDF