• Title/Summary/Keyword: abnormal power source

Search Result 35, Processing Time 0.029 seconds

A Study on the Development of Abnormal Power Source Generator to Evaluate Electronic Appliances (시험용 이상전원(異狀電源) 발생장치의 개발에 관한 연구)

  • Park, Chan-Won;Rho, Jea-Kwan
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.83-90
    • /
    • 2004
  • Generally, electronic appliances are used on the basis of normal power source supply. The power source inevitably includes the abnormal condition, such as, sudden voltage sagging, power interrupt, and induced noises. As the electronic appliances which include micro-controller-based circuits are being increased recently, the controller circuit sometimes malfunctions by the abnormal condition of the power source. This situation causes serious problems such as hitch of electric appliance, fire and medical instrument glitch, which produces serious situations. In this paper, development of power interrupt tester which is highly suitable for an endurance test device under abnormal power source to microprocessor-based circuits is proposed 89C2051 microcontroller is performed to make power interrupt signal, and software controls peripheral hardwares and built-in functions. Experimental results of this study will offer a good application to electronic appliance maker as a test device of hardware and software debugging use.

  • PDF

Development of Noise Source Detection System using Array Microphone in Power Plant Equipment (배열형 음향센서를 이용한 발전설비 소음원 탐지시스템 개발)

  • Sohn, Seok-Man;Kim, Dong-Hwan;Lee, Wook-Ryun;Koo, Jae-Raeyang;Hong, Jin-Pyo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.99-104
    • /
    • 2015
  • In this study, it has been initiated to investigate the specific abnormal vibration signal that has been captured in the power equipment. Array Microphone can be used in order to detect the direction and the position of the noise source. It is possible to track the abnormal mechanical noise in the power plant by utilizing the program and the microphone array system developed from this research. Array microphone system can be operated as a constant monitoring system.

Source identification of abnormal noise caused in diesel railcars through spectrum analysis (스펙트럼 분석을 통한 디젤동차 애상소음 원인규명)

  • 이용관;강명석
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.208-217
    • /
    • 1999
  • This paper presents spectrum analysis technique to identify abnormal noise produced in diesel railcars. Coherence and coherent power spectrum are very useful in determining source identifications. Experiments are applied to two different cars with similar phenomena about the case of stop and running condition. Metal contact in mounting bracket part which is excited by excessive transmission vibration is found to cause abnormal noise.

  • PDF

Abnormal Resonance Noise Phenomenon and Effect through Exhaust Gas Passageway in Urban Combined Power Plant (도심지 복합화력 배가스 통로에서의 이상 소음 현상과 영향)

  • Kim, Yeon-Whan;Lee, Young-Shin;Bae, Yong-Chae;Lee, Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.866-869
    • /
    • 2004
  • Power transformers, air-intakes and stacks in the urban combined power plant are main noisy sources. Because of Inhabitant complaint by abnormal noise transferred from the power plant. the noise was investigated at power plant and uptown area. The result of diagnosis made the acoustic resonance phenomenon by 580Hz's combustion dynamic pressure with the standing wave mode of sound fields in exhaust passageway of gas turbine into main noise source of public complain. The abnormal noise is caused by the resonance exhaust noise transferred through stacks of power plant.

  • PDF

A Parallel Processing Uninterruptible Power Supply for Sudden Voltage Fluctuation for Computer Applications

  • Lee, Su-Won;Ko, Sung-Hun;Lee, Seong-Ryong;Jung, Yong-Chae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.287-289
    • /
    • 2009
  • This paper deals with a parallel processing uninterruptible power supply (UPS) for sudden voltage fluctuation in computer applications to integrate power quality improvement, load voltage stabilization and UPS. To reduce the complexity, cost and number of power conversions, which results in higher efficiency, only one voltage-controlled voltage source inverter (VCVSI) is used. The system provides sinusoidal voltage at the fundamental value of 220V/60Hz for the load during abnormal utility power conditions or grid failure. Also, the system can be operated to mitigate the harmonic current and voltage demand from nonlinear loads and provide voltage stabilization for loads when sudden voltage fluctuation occur, such as sag and swell. System operation simulation demonstrates that the system protects against outages caused by abnormal utility power conditions and sudden voltage fluctuations and changes.

  • PDF

Development of Portable Power Interrupt Tester using Microcontroller (휴대형 전원 순단 시험 장치의 개발)

  • Park, C.W.;Rho, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.962-964
    • /
    • 2003
  • In this paper, development of portable power interrupt tester to evaluate microprocessor based control circuits for an endurance under abnormal power source. 89C2051 micro-controller is performed to make power interrupt signal, and software controls peripheral hardwares and built-in functions. Experimental results of this study will offer a good application to electronic appliance maker as a test device of hardware and software debugging use.

  • PDF

Improving the Output Current of Matrix Converter under Abnormal Input Voltage Conditions using a Neural Network Compensator (입력 전원 외란 상황에서의 신경회로망 기반 전류 보상기를 이용한 매트릭스 컨버터의 출력 전류 개선)

  • Lee, Eun-Sil;Park, Ki-Woo;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.199-206
    • /
    • 2010
  • Matrix converter is an energy conversion device of controlled power semiconductor switches that directly connects the three-phase source to the three-phase load. With no dc-link components for energy storage in the matrix converter the input current depends directly upon the load currents and the switch state of the converter. Therefore the unbalanced and distorted input voltages can result in unwanted output harmonic currents. This paper presents a current compensator based on neural network to improving output current quality for matrix converter under abnormal input voltage conditions. The effectiveness and feasibility of the proposed technique has been proven through numerical simulations and experimental tests.

Inrush Current Elimination for a Three-Phase Off-Line UPS System (3상 오프라인 무정전 전원 시스템의 돌입전류 제거)

  • Bukhari, Syed Sabir Hussain;Kwon, Byung-il
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.944-945
    • /
    • 2015
  • Many sensitive loads always rely on UPS systems to maintain continuous power during abnormal utility power conditions. As any disturbance occurs at the utility side, an off-line UPS system takes over the load within a quarter cycle to avoid a blackout. However, the starting of the inverter can root the momentous inrush current for the transformer installed before the load, due to its magnetic saturation. The consequences of this current can be a reduction of line voltage and tripping of protective devices of the UPS system. Furthermore, it can also damage the transformer and decrease its lifetime by increasing the mechanical stresses on its windings. To prevent the inrush current, and to avoid its disruptive effects, this paper proposes an off-line UPS system that eliminates the inrush current phenomenon while powering the transformer coupled loads, using a current regulated voltage source inverter (CRVSI) instead of a typical voltage source inverter (VSI). Simulations have been performed to validate the operation of proposed off-line UPS system.

  • PDF

Effects of AlN Ratio on Microstructure of AlN Films Grown by PAMBE (PAMBE를 이용하여 성장된 AlN 박막의 미세구조에 미치는 Al/N 비율 영향)

  • 홍성의;한기평;백문철;조경익;윤순길
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.12
    • /
    • pp.972-978
    • /
    • 2001
  • Some effects of Al/N ratio on microstructure of AlN films grown on Si(111) substrates by PAMBE were investigated. Al/N ratio was controlled by rf power of N$_2$ plasma source system. Al excess or N excess conditions were obtained below or above 350 W rf power, respectively. Surface roughness and morphology of AlN film grown at Al/N=1.0 showed the best result. Under Al excess condition, it was suggested that excess Al atoms which did not contribute to the growth of AlN film prevent the normal crystal growth and make abnormal growth of some columns. However, under N excess condition, it was explained that some of the excess active N source turned into gas state and then desorbed out from substrate.

  • PDF

Implementation of a Real-Time Data Acquisition System Based on Wireless Communication for Urban Rail Transit Substation (도시철도 변전소의 네트워크 기반 실시간 데이터 취득 시스템 구현)

  • Jung, Ho-Sung;Park, Young;Kim, Hyung-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.71-76
    • /
    • 2010
  • This paper is focused on implementing a real-time data acquisition system that checks power facility status by applying network based technology to Urban Transit substation power facilities and the results of its on-field tests. This system is composed of a sensor part, a measurement part, a transceiver part, a host computer, and a power source part. The system is designed to collect, save, analyze, and display the online state power facility AI (Analog Input). This system measures voltage and current from positive feeders and negative feeders where it is possible to check abnormalities of the substation‘s main power facilities. By monitoring abnormal data of the Urban Transit power facilities real-time and analyzing stored data, establishing procedures of optimized maintenance is possible.