• 제목/요약/키워드: ablation condition

검색결과 58건 처리시간 0.032초

나노초 레이저를 이용한 PMMA의 습식 및 건식어블레이션 비교 연구 (Comparison study of nanosecond laser induced wet and dry ablation of PMMA)

  • 이호
    • 한국산업융합학회 논문집
    • /
    • 제22권3호
    • /
    • pp.243-250
    • /
    • 2019
  • The nanosecond laser assisted ablation have been investigated. The biocompatable polymer PMMA was employed as the target material and the two distinctive surface conditions were test. The first surface condition is a dry surface for which the target surface is exposed to air and the second surface condition is the wet surface for which the target surface is covered with dehydrated water. The ablation volume, the laser induced acoustic wave, the laser induced plasma were investigated for both wet and dry condition. The nanosecond laser pulse ablatied more on the wet surface compared to the dry surface. The enhanced ablation of wet surface is attributed to the confined acoustic wave and the laser-induced plasma in the liquid layer.

알루미나 세라믹 소재의 초단파 레이저 어블레이션량 연구 (Ablation rate study using short pulsed laser subjected to Alumina medium)

  • 김경한;박진호
    • 한국레이저가공학회지
    • /
    • 제18권4호
    • /
    • pp.17-22
    • /
    • 2015
  • In this paper, ablation rate of $Al_2O_3$ ceramics by femtosecond laser fluence is derived with experimental method. The automatic three axis linear stage makes laser optics to move with high spatial resolution. With 10 times objective lens, minimal pattern width of $Al_2O_3$ is measured in the focal plane. Ablated surface area is shown as linear tendency increasing number of machining times with various laser power conditions. Machining times is most sensitive condition to control $Al_2O_3$ pattern width. Also, the linear increment of pattern width with laser power change is investigated. In high machining speed, the ablation volume rate is more linear with fluence because pulse overlap is minimized in this condition. Thermal effect to surrounding medium can be minimized and clean laser process without melting zone is possible in high machining speed. Ablation volume rate decelerates as increasing machining times and multiple machining times should be considered to achieve proper ablation width and depth.

펨토초 레이저를 이용한 OLED 용 Shadow Mask Invar 합금의 어블레이션 (Femtosecond Pulsed Laser Ablation of OLED Shadow Mask Invar Alloy)

  • 정일영;강경호;김재도;손익부;노영철;이종민
    • 한국정밀공학회지
    • /
    • 제24권12호
    • /
    • pp.50-56
    • /
    • 2007
  • Femtosecond laser ablation of the Invar alloy and hole drilling for a shadow mask are studied. We used a regenerative amplified Ti-sapphire laser with a 1kHz repetition rate, 184fs pulse duration and 785nm wavelength. Femtosecond laser pulse was irradiated on the Invar alloy with air blowing at the condition of various laser peak power. An ablation characteristic of the Invar alloy was appeared non-linear at $125J/cm^2$ of energy fluence. For the application to a shadow mask, the hole drilling of the Invar alloy with the cross section of a trapezoidal shape was investigated. The ablated micro-holes were characterized using an atomic force microscopy(AFM). The optimal condition of hole pattern f3r a shadow mask was $4\;{\mu}m$ z-axis feed rate, 0.2mm/s circular velocity, $26.4{\mu}J$ laser peak power. With the optimal processing condition, the fine circular hole shape without burr and thermal damage was achieved. Using the femtoseocond laser system, it demonstrates excellent tool for the Invar alloy micro-hole drilling without heat effects and poor edge.

빔 중첩율에 따른 티타늄 합금의 펨토초 레이저 어블레이션 (The Femto Second Laser Induced Ablation on the Titanium Alloy for Various Beam Overlap Ratio)

  • 정일영;강경호;김재도
    • 한국정밀공학회지
    • /
    • 제27권11호
    • /
    • pp.17-23
    • /
    • 2010
  • Titanium alloy is one of the hard processing materials made by the traditional manufacturing method because of the excellent mechanical strength. Ablation of titanium alloy is investigated by using a femtosecond laser which is a regenerative amplified Ti:sapphire laser with 1kHz repetition rate, 184fs pulse duration time and 785nm wavelength. Experiments are carried out under various ablation conditions with different pulse overlap ratios for the rectangular shape and micro hole. Test results show that the ablation characteristic according to pulse overlap ratio of titanium alloy seems to be as non-linear type at the different zone of energy fluence. The optimal condition of rectangular shape processing is obtained at the laser peak power 1.3mW, pulse overlap ratio of 90%, beam gap of $1\;{\mu}m$. The micro hole has a good quality from the pulse overlap ratio of 99% at the same laser peak power. With the optimal processing condition, the fine rectangular shape and micro hole without burr and thermal damage are achieved.

펨토초 레이저의 이송속도에 따른 Invar 합금의 어블레이션 특성 (Characteristics of the Femto-second Pulsed Laser Ablation according to Feed Velocity on the Invar Alloy)

  • 정일영;강경호;김재도;손익부;노영철;이종민
    • 한국정밀공학회지
    • /
    • 제26권3호
    • /
    • pp.25-31
    • /
    • 2009
  • Femto-second laser ablation with the various feed velocities of the Invar alloy and the micro surface milling for the processing condition were studied. We used a regenerative amplified Ti:sapphire laser with a 1kHz repetition rate, 184fs pulse duration time and 785nm wavelength. Femto-second laser pulse was irradiated on the Invar alloy with the air blowing at the condition of various laser peak powers and feed velocities. An ablation characteristic according to feed velocity of the Invar alloy was appeared as the non-linear type at different zone of energy fluence. The micro surface milling of the Invar alloy using a mapping method was investigated. The optimal condition of micro surface milling was laser peak power of 22.8mW, feed velocity of 1 mm/s, beam gap of $1{\mu}m$. With the optimal processing condition, the fine rectangular shape without burr and thermal damage was achieved. Using the femto-second laser system, it demonstrates excellent tool for micro surface milling of the Invar alloy without heat effects and poor edge.

Analysis for the Coolability of the Reactor Cavity in a Korean 1000 MWe PWR Using MELCOR 1.8.3 Computer Code

  • Lee, Byung-Chul;Kim, Ju-Yeul;Chung, Chang-Hyun;Park, Soo-Yong
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.669-674
    • /
    • 1996
  • The analysis for the coolability of the reactor cavity in typical Korean 1000 MWe Nuclear Unit under severe accidents is performed using MELCOR 1.8.3 code. The key parameters molten core-concrete interaction(MCCI) such as melt temperature, concrete ablation history and gas generation are investigated. Total twenty cases are selected according to ejected debris fraction and coolant mass, The ablation rate of concrete decreases as mass of the melt decreases and coolant mass increases. Heat loss from molten pool to coolant is comparable to total decay heat, so concrete ablation is delayed until water is absent and crust begins to remove. Also, overpressurization due to non-condensible gases generated during corium and concrete interacts can cause to additional risk of containment failure. It is concluded that flooded reactor cavity condition is very important to minimize the cavity ablation and pressure load by non-condensible gases on containment.

  • PDF

열적 메커니즘에 의한 펄스레이저 어블레이션 현상의 수치계산 (Numerical computation of pulsed laser ablation phenomena by thermal mechanisms)

  • 오부국;김동식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1572-1577
    • /
    • 2003
  • High-power pulsed laser ablation under atmospheric pressure is studied utilizing numerical and experimental methods with emphasis on recondensation ratio, and the dynamics of the laser induced vapor flow. In the numerical calculation, the temperature pressure, density and vaporization flux on a solid substrate are first obtained by a heat-transfer computation code based on the enthalpy method, and then the plume dynamics is calculated by using a commercial CFD package. To confirm the computation results, the probe beam deflection technique was utilized for measuring the propagation of a laser induced shock wave. Discontinuities of properties and velocity over the Knudsen layer were investigated. Related with the analysis of the jump condition, the effect of the recondesation ratio on the plume dynamics was examined by comparing the pressure, density, and mass fraction of ablated aluminum vapor. To consider the effect of mass transfer between the ablation plume and air, unlike the most previous investigations, the equation of species conservation is simultaneously solved with the Euler equations. Therefore the numerical model computes not only the propagation of the shock front but also the distribution of the aluminum vapor. To our knowledge, this is the first work that employed a commercial CFD code in the calculation of pulsed ablation phenomena.

  • PDF

피코초 레이저를 이용한 Eagle Glass 절단 시 가공성 평가 (Processing Evaluations of the Eagle Glass Cutting Using Pico-second Laser)

  • 이상균;이영곤;김재도
    • 한국정밀공학회지
    • /
    • 제30권4호
    • /
    • pp.403-408
    • /
    • 2013
  • In this paper, the characteristics of ablation processing of the eagle glass by pico-second laser are investigated. The laser ablation is used to process micro forms on materials. The ablation causes little thermal effect and little burr on the surface of eagle glass. In order to examine the characteristics of panic cracks, experiments are conducted under various cutting conditions such as a frequency of 600 kHz, laser powers, scan speeds and number of scan(NS). To minimize the panic cracks, the specimens are heated at $30^{\circ}C$, $45^{\circ}C$, and $60^{\circ}C$ for ten minutes respectively and then they are broken by hands. Laser powers, NS and scan speeds have an effect on glass cutting results. The ablation depths increase with an increase in the laser power and NS whereas the panic cracks decrease with an increase in scan speed. The high temperature on processed specimens reduces the panic cracks and makes good results of laser cutting. The optimal condition for eagle glass laser cutting is found to be at 30 W of laser power, 3 mm/s of scan speed and 500 of NS, respectively.

Selective Laser Direct Patterning of Indium Tin Oxide on Transparent Oxide Semiconductor Thin Films

  • Lee, Haechang;Zhao, Zhenqian;Kwon, Sang Jik;Cho, Eou Sik
    • 반도체디스플레이기술학회지
    • /
    • 제18권4호
    • /
    • pp.6-11
    • /
    • 2019
  • For a wider application of laser direct patterning, selective laser ablation of indium tin oxide (ITO) film on transparent oxide semiconductor (TOS) thin film was carried out using a diode-pumped Q-switched Nd:YVO4 laser at a wavelength of 1064 nm. In case of the laser ablation of ITO on indium gallium zinc oxide (IGZO) film, both of ITO and IGZO films were fully etched for all the conditions of the laser beams even though IGZO monolayer was not ablated at the same laser beam condition. On the contrary, in case of the laser ablation of ITO on zinc oxide (ZnO) film, it was possible to etch ITO selectively with a slight damage on ZnO layer. The selective laser ablation is expected to be due to the different coefficient of thermal expansion (CTE) between ITO and ZnO.

A comparison of different gingival depigmentation techniques: ablation by erbium:yttrium-aluminum-garnet laser and abrasion by rotary instruments

  • Lee, Kwang-Myung;Lee, Dong-Yeol;Shin, Seung-Il;Kwon, Young-Hyuk;Chung, Jong-Hyuk;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • 제41권4호
    • /
    • pp.201-207
    • /
    • 2011
  • Purpose: The aim of this study is to compare two different gingival depigmentation techniques using an erbium:yttrium-aluminum-garnet (Er:YAG) laser and rotary instruments. Methods: Two patients with melanin pigmentation of gingiva were treated with different gingival depigmentation techniques. Ablation of the gingiva by Er:YAG laser was performed on the right side, and abrasion with a rotary round bur on the opposite side. Results: The patients were satisfied with the esthetically significant improvement with each method. However, some pigment still remained on the marginal gingival and papilla. The visual analog scale did not yield much difference between the two methods, with slightly more pain on the Er:YAG laser treated site. Conclusions: The results of these cases suggest that ablation of the gingiva by an Er:YAG laser and abrasion with a rotary round bur is good enough to achieve esthetic satisfaction and fair wound healing without infection or severe pain. Prudent care about the gingival condition, such as the gingival thickness and degree of pigmentation along with appropriate assessment is needed in ablation by the Er:YAG laser procedure.