• 제목/요약/키워드: a chamber

검색결과 6,497건 처리시간 0.053초

포항 가속기 저장링 진공 chamber 설계 (Vacuum Chamber Design for the PLS Storage Ring)

  • 김창균;길계환;최우천;박수용
    • 한국진공학회지
    • /
    • 제1권1호
    • /
    • pp.24-27
    • /
    • 1992
  • The Pohang Accelerator Lab is constructing a 2 GeV synchrotron radiation source. In order to achieve a beam lifetime of 5 hours or more, the average pressure in the vacuum chamber will be kept in the nano Torr range. Each chamber consists of a top and a bottom piece, which are machined separately and welded together. The chamber material is A1 5083-H321. The pumping system has nine sets of lumped NEGs in tandem with ion pumps installed beneath photon stops, and six ion pumps per superperiod. A prototype chamber will be machined by February 1992. After various tests with the prototype chamber, the vacuum chamber design will be refined.

  • PDF

다중식 가두리 개발에 관한 연구 (A Study on the Development of Moving Watched Chamber)

  • 홍봉기;김인철
    • 수산해양기술연구
    • /
    • 제31권1호
    • /
    • pp.93-106
    • /
    • 1995
  • This paper describes the development of moving watched chamber. For the most part, the watched chamber have been located in the inner-bay. But, there are many problems of sea-water pollution. Therefore, the watched chamber must be relocated to undeveloped coastal area. The watched chamber which is located in the bay has a bit of damage by bad weather. But, the moving watched chamber would be exposed to bad water. It is desirable to improve the system of chamber. If we make a good design of the moving watched chamber with studying of waves and hydrodynamics, it would be possible to culture fish at the coastal sea area. When a fixed system is changed into a movable one, we can obtain the following advantages: 1. The possibility of diminishing the sea water pollution, easying the overcrowded state in a inner-bay farm, and relieved of limitation caused by bad conditions such as waves, red tides and terrains. 2. It would be easy not only to move the watched chamber system in accordance with weather conditions or occurrence of red tides, but also to select good sites for watched chamber fishes. 3. Transportation and good supervision with the automated design system can results with the effectiveness which increases the amount of aquatic products.

  • PDF

유동 가이드가 열파퍼 플라즈마 챔버의 아크현상 이력에 미치는 영향 (Effects of a Flow Guide on the Arcing History in a Thermal Puffer Plasma Chamber)

  • 이종철;김윤제
    • 대한기계학회논문집B
    • /
    • 제31권10호
    • /
    • pp.832-839
    • /
    • 2007
  • The geometry and dimensions of an expansion chamber are decisive factors in thermal puffer plasma chamber designs. Because they together dominate the temperature and speed at which the cooling gas from the chamber flows back through a flow channel to the arcing zone for the successful interruption of fault currents. In this study, we calculated the flow and mass transfer driven by arc plasma, and investigated the effects of a flow guide installed inside a thermal puffer plasma chamber. It is found that the existing cold gas of the chamber mixes with hot gases entrained from the arcing zone and is subjected to compression due to pressure build-up in the chamber. The pressure build-up with the flow guide is larger than that without due to a vortex which rotates clockwise around the chamber center. By the reverse pressure gradient, the mixing gas of the chamber flows back out for cooling down the residual plasma near current zero. In the case with the flow guide, the temperature just before current zero is lower than that without, and the Cu concentration with high electrical conductivity is also less than that without the flow guide.

하이브리드 로켓 추진 시스템의 혼합 연소실 적용에 따른 Trade-off 평가 (Trade-off Evaluation due to Application of Mixing Chamber for Hybrid Rocket-Propulsion System)

  • 김학철;문근환;문희장;김진곤
    • 항공우주시스템공학회지
    • /
    • 제10권3호
    • /
    • pp.23-31
    • /
    • 2016
  • The intermediate mixing chamber is one of various methods for improving the regression rate and combustion efficiency of the hybrid rocket. The mixing chamber with its non-combustible material makes the propulsion performance increase, but it leads to a low fuel-loading density in the combustion chamber; therefore, this performance-related trade-off between the mixing chamber and the low fuel-loading density was studied. In this study, the trade-off was conducted by comparing the intermediate-mixing-chamber case with a w/o-mixing-chamber case. The small hybrid-sounding rocket is designed with internal ballistics for comparing the rocket length to the weight. In addition, an external ballistic analysis was conducted for comparing the performances of the w/- and w/o-mixing-chamber cases. As a result, the intermediate-mixing-chamber case shows that the length and the weight were decreased to 12 % and 8 %, respectively; furthermore, when compared with the normal cases, the estimated altitude result of the w/-mixing-chamber case was increased to approximately 75 m.

가스 절연 시험용 체임버 개발 연구 (A Study on the Development of a 1800KV Testing Chamber for Gas Insulation)

  • 조연옥;최병주;김광수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.405-408
    • /
    • 1989
  • A 1800KV testing chamber for gas insulation has been developed. To develop the chamber, all parts consisting of the chamber, namely, bushing, main chamber, shield, conductor bus, inspection window, feedthrough, and spacer have been designed based on numerical electric field analysis. This paper presents the detailed design philosophy and methods of the chamber.

  • PDF

식물생장용 저압챔버 내의 기온, 상대습도 및 압력의 변화 (Variations of Air Temperature, Relative Humidity and Pressure in a Low Pressure Chamber for Plant Growth)

  • 박종현;김용현
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.200-207
    • /
    • 2009
  • This study was conducted to analyze the variations of air temperature, relative humidity and pressure in a low pressure chamber for plant growth. The low pressure chamber was composed of an acrylic cylinder, a stainless plate, a mass flow controller, an elastomer pressure controller, a read-out-box, a vacuum pump, and sensors of air temperature, relative humidity, and pressure. The pressure leakage in the low pressure chamber was greatly affected by the material and connection method of tubes. The leakage rate in the low pressure chamber with the welding of the stainless tubes and a plate decreased by $0.21kPa{\cdot}h^{-1}$, whereas the leakage in the low pressure chamber with teflon tube and rubber O-ring was given by $1.03kPa{\cdot}h^{-1}$. Pressure in the low pressure chamber was sensitively fluctuated by the air temperature inside the chamber. An elastomer pressure controller was installed to keep the pressure in the low pressure chamber at a setting value. However, inside relative humidity at dark period increased to saturation level.. Two levels (25 and 50kPa) of pressure and two levels (500 and 1,000sccm) of mass flow rate were provided to investigate the effect of low pressure and mass flow rate on relative humidity inside the chamber. It was concluded that low setting value of pressure and high mass flow rate of mixed gas were the effective methods to control the pressure and to suppress the excessive rise of relative humidity inside the chamber.

공기챔버 위치에 따른 폰툰형 초대형 구조물 유탄성응답 해석 (Hydroelastic Analysis of Pontoon Type VLFS Considering the Location and Shape of OWC Chamber)

  • 홍사영;경조현;김병완
    • 한국해양공학회지
    • /
    • 제22권1호
    • /
    • pp.22-29
    • /
    • 2008
  • A numerical investigation is made on the effects of the location and shape of the front wall of an OWC(Oscillating Water Column) chamber on the hydroelastic response of a VLFS. Most of the studies on the effects of an OWC chamber on the response of a VLFS have assumed the location of the OWC chamber to be at the front of the VLFS. In the present study, an OWC-chamber is introduced at an arbitrary position in relation to a VLFS to determine the influence of the location and shape of the OWC chamber on the hydroelastic response of the VLFS. A finite element method is adopted as a numerical scheme for the fluid domain. or the finite element method, combined with a mode superposition method, is applied in order to consider the change of mass and stiffness The OWC chamber in a piecewise constant manner. or the facilitated anefficient analysis of The hydroelastic response of the VLFS, as well as the easy modeling of different shape and material properties for the structure. Reduction of hydroelastic response of the VLFS is investigated for various locations and front wall shapes of the owe chamber.

부실을 가진 정적연소기에서 부실형상의 최적화 연구 (An Study on the Optimization of Sub-chamber Geometry in CVC with Sub-chamber)

  • 박종상;강병무;염정국;하종률;정성식
    • 한국분무공학회지
    • /
    • 제10권2호
    • /
    • pp.1-9
    • /
    • 2005
  • An experimental study was carried out to obtain the fundamental data about the effects of radical ignition on premixture combustion. A CVC(constant volume combustor) divided into the sub-chamber and the main chamber was used. Numerous narrow passage holes are arranged between the main chamber and the sub-chamber. The products including radicals generated by spark ignition in tile sub-chamber derives the simultaneous multi-point ignition in the main chamber. We have examined the effects of the sub-chamber volume, the diameter and number of passage holes, and the equivalence $ratio({\Phi})$ on the combustion characteristics by means of burning pressure measurement and flame visualization. In a CVC, the overall burning time including the ignition delay became very short and the maximum burning pressure was slightly increased by the radical ignition(RI) method in comparison with those by the conventional spark ignition(SI) method. Combustible lean limit by RI method is extended by ${\Phi}=0.25$ compared with that by SI method. Also, In cases of charging the number and the diameter for the fixed total cross section of the passage holes, combustion period increased significantly at a sub-chamber with a single hole, but those of the other conditions had almost a similar tendency in the sub-chamber with 4 or more holes. regardless of equivalence ratio. Therefore, it was Proved that a critical cross section exists with the number of passage holes.

  • PDF

가호기 건조 시스템에서 수치적 유동해석 (Numerical Analysis of the Flow in the Drying Chamber of a Sizing Machine)

  • 이진호;김수연
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 1996년도 추계 학술발표회
    • /
    • pp.29-34
    • /
    • 1996
  • In the present paper, the flow distribution in the hot air drying chamber of a sizing machine was numerically analyzed with respect to the geometries of the intake duct to obtain the more uniform flow distribution in the chamber. The result shows that the velocity distribution in the inlet of the chamber was significantly dependent on the the geometry of the intake duct. The degree of the non-uniformity in the chamber was reduced as the incident angle of the intake duct became to be smaller.

  • PDF

모형 지반의 최대 전단탄성계수 평가를 위한 벤더 엘리먼트 시험의 적용 (Application of Bender Element Tests for the Estimation of Maximum shear Modulus in Calibration Chamber)

  • 권형민;고영주;정충기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1278-1284
    • /
    • 2008
  • This study carried out bender element tests in a calibration chamber in order to estimate the characteristics of soil specimen prepared in a calibration chamber. Basically, the purpose of bender element test is to measure the shear wave velocity. Bender element test cannot only confirm the status of soil specimen deposited in a chamber, but also estimate the consolidation process indirectly. In order to carry out bender element test in a calibration chamber, a pair of bender elements was installed inside the chamber, using the 'ㄷ' shaped frame. For the sandy soils having various relative densities in various stress conditions, the maximum shear modulus was estimated. From the comparison with bender element test results in a triaxial testing device, testing device and procedure was validated.

  • PDF