• 제목/요약/키워드: Zone 1a

검색결과 5,405건 처리시간 0.027초

7구역진단기의 Factor AA 제1, 2, 3구역 유형과 임상지표와의 상관성 연구 (A Study on the Correlation among the Patterns of the Zone 1, 2, 3 of Factor AA in 7-Zone-Diagnostic System and the Clinical Parameters)

  • 조이현;유정석;이휘용;송범용
    • Journal of Acupuncture Research
    • /
    • 제25권6호
    • /
    • pp.67-76
    • /
    • 2008
  • Objectives : The 7-zone-diagnostic system is a diagnostic device to predetermine bodily locations by measuring the energy of body. This study was to investigate the relation between the different patterns of Zone 1, 2, 3 of Factor AA in CP-6000A(VEGA, Germany), 7-zone-diagnostic system and clinical parameters. The purpose of this study was relation Korean traditional medicine and western medicine with the data from 7-zone-diagnostic system and the clinical parameters. Methods : This study was carried out with the data from some clinical parameters. We made three groups according to the Factor AA patterns of CP-6000A. The Factor AA pattern of Group A is that the red bar graph of zone 1, 2, 3 were higher than the normal range and the others were the normal range. The Factor AA pattern of Group B was that the red bar graph of zone 1, 2, 3 was the normal range and the others were the normal range. The Factor AA pattern of Group C was that the red bar graph of zone 1, 2, 3 was lower than the normal range and the others were the normal range. After the data from clinical parameters to correspond with conditions of each group were selected, the data from clinical parameters among each groups analyzed statistically. Results : The values of GOT, GPT, r-GPT, Triglyceride, BUN, Uric acid of group A was higher than group C. Gastroscope of group A and B was higher than group C. Conclusions : It is thought that the red bar graph of zone 1, 2, 3 is higher, the group has the higher energy and the energy has a character of fire(熱). Those patterns have a high risk of hyperlipermia and liver, stomach disease.

  • PDF

어린이의 안전한 보행을 위한 iZone 시스템 (The iZone System for Safety Walking of Children)

  • 민성희;오유수
    • 한국멀티미디어학회논문지
    • /
    • 제22권1호
    • /
    • pp.62-69
    • /
    • 2019
  • In this paper, we propose iZone system for safe walking of children. The proposed system recognizes the state that a child is down a roadway as a dangerous situation. And then it informs the surrounding adults and guardians of the child in the event of a dangerous situation. The iZone system consists of the iZone device that attaches to a child's bag or clothing, the iZone app for children, the iZone server, and external beacons. The proposed system uses the ultrasonic sensor of the iZone device and the GPS coordinates and external beacons information by the children's smartphone to determine the dangerous situation. The proposed system uses external beacons to calibrate the GPS coordinates. Moreover, it determines whether the child is down the roadway in sidewalk by measuring the height difference between the roadway and the sidewalk using ultrasonic sensor.

7구역진단기의 5구역 정보와 위내시경 소견의 상관성에 관한 연구 (Correlations between Gastroscopy Results and Zone-5 Data from the 7-zone-Diagnostic System)

  • 정다정;임정균;이형걸;육태한;김종욱
    • Journal of Acupuncture Research
    • /
    • 제30권1호
    • /
    • pp.1-11
    • /
    • 2013
  • Objectives : The 7-zone-diagnostic system is a device for predetermining bodily locations by measuring the energy of the living body. The purpose of this study is to examine correlations between gastroscopy results and zone-5 data from the 7-zone-diagnostic system. Methods : This study was carried out with data from gastroscopy procedures. It involved 115 patients who had been diagnosed with gastritis, esophagitis, or gastric ulcers. These patients were divided into three groups according to the different patterns of zone-5 factors AA, FL2 and FL1. Group A was made up of patients for whom the red bar graph of zone-5 was higher than the normal range for factor AA. Group B was made up of patients for whom the red bar graph of zone-5 was within the normal range for factor AA. Group C was made up of patients for whom the red bar graph of zone-5 was lower than the normal range for factor AA. Group D E and F were made up of same way as group A B and C for factor FL2. Group G H and I were made up of same way as group A B and C for factor FL1. After the collection of gastroscopy results and data on zone-5 from the 7-zone-diagnostic system, the data was analyzed statistically. Results : 1. Group D had a higher ratio of medication than group E, and this result was statistically significant. 2. Group D G had a higher ratio of medication than group E G and group E H, and this result was statistically significant. 3. Group G had a higher ratio of esophagitis than group H, and this result was statistically significant. 4. A Group B H had a higher ratio of esophagitis than group B G, group C G, and group C H, and this result was statistically significant. 5. The medication group had a high score on the function index than the non-medication group, and this result was statistically significant. Conclusions : This study suggests that there is a slight correlation between gastroscopy results and zone-5 data from the 7-zone-diagnostic system. The research resulted in significant data that are helpful for diagnosing digestive system problems through the use of the 7-zone-diagnostic system.

IgY (Immunoglobulin Yolk) 분리를 위한 3-영역 SMB (Simulated Moving Bed)와 4-영역 SMB 비교전산모사 (Comparative Simulation of 3-zone SMB (Simulated Moving Bed) and 4-zone SMB for IgY (Immunoglobulin Yolk) Purification)

  • 윤상희;김인호
    • Korean Chemical Engineering Research
    • /
    • 제50권5호
    • /
    • pp.866-873
    • /
    • 2012
  • 난황에 포함된 IgY는 포유동물에 있는 바이러스나 항원에 반응하는 항체와 같은 역할을 한다. 난황을 전처리한 후 3-zone와 4-zone SMB를 이용하여 지질단백질들로 부터 IgY를 분리하는 전산모사연구를 수행하였다. 회분식 크로마토그래피에서 전산모사 매개변수와 흡착 등온식 SMB 전산모사 변수를 얻었다. Aspen simulator를 이용하여 전산모사를 수행하여 IgY를 분리할 수 있는 3-zone과 4-zone SMB 운전조건을 비교하여 다음과 같은 결과를 얻었다. IgY와 다른 단백질의 농도와 순도를 모두 고려할 때, 꼭지점인 좌표($m_2$, $m_3$=0.1, 1.1)에서 3-zone SMB가 최적의 조건으로 생각된다. IgY 만을 고려하면 4-zone SMB가 좌표($m_2$, $m_3$=0.06, 0.5)에서 가장 높게 IgY를 분리할 수 있었다. recycle이 없는 3-zone SMB는 꼭지점 좌표에서 좌표이동이 extract의 지질 단백질 농도에 큰 영향을 주었다.

부산항 관세자유지대의 경제적 파급효과에 관한 연구 - 부산신항만 1단계 준공시점을 대상으로 - (The Economic Impact of Establishing a Customs Free Zone in the Port of Busan Focusing on the Time of Completion of the 1st Phase of the New Port of Pusan)

  • 이수호;손애휘
    • 한국항만경제학회지
    • /
    • 제17권1호
    • /
    • pp.53-72
    • /
    • 2001
  • This study focuses on analyzing the economic effects and probes the necessity of establishing a customs free zone at the Port of Busan. It first considers the economic effects of establishing a customs free zone at the Port of Busan, then suggests policy prescriptions for introducing and operating the free zone system and improving the logistics functions of the Port. The timeline of this study is focused on 2007, when all of Busan Port will operate as a customs free zone and the first stage of the New Busan Port and distribution parks will be built and opened for operation. The regression analysis, which was conducted using the inter-industry relations table(input-output table data), provided a quantitative prediction on the effects of making Busan Port into a customs free zone. Regarding the impact of a free zone system on the domestic and regional economy, this research found that the impact of a customs free zone on domestic industries and the regional economy once the customs free zone is established throughout all of Busan Port would be highly positive. The positive economic effects on the domestic and Busan regional economy might be further strengthened if the value-added logistics function of Busan Port could be supplemented by effective linking to the hinterlands.

  • PDF

Effect of spatial characteristics of a weak zone on tunnel deformation behavior

  • Yoo, Chungsik
    • Geomechanics and Engineering
    • /
    • 제11권1호
    • /
    • pp.41-58
    • /
    • 2016
  • This paper focuses on the deformation behavior of tunnels crossing a weak zone in conventional tunneling. A three-dimensional finite element model was adopted that allows realistic modeling of the tunnel excavation and the support installation. Using the 3D FE model, a parametric study was conducted on a number of tunneling cases with emphasis on the spatial characteristics of the weak zone such as the strike and dip angle, and on the initial stress state. The results of the analyses were thoroughly examined so that the three-dimensional tunnel displacements at the tunnel crown and the sidewalls can be related to the spatial characteristic of the weak zone as well as the initial stress state. The results indicate that the effectiveness of the absolute displacement monitoring data as early warning indicators depends strongly on the spatial characteristics of the weak zone. It is also shown that proper interpretation of the absolute monitoring data can provide not only early warning for a weak zone outside the excavation area but also information on the orientation and the extent of the weak zone. Practical implications of the findings are discussed.

Traveling solvent Floating Zone법에 의한 $Y_3Fe_5O_{12}$단결정 육성 (Single Crystal Growth of $Y_3Fe_5O_{12}$ by the Traveling solvent Floating Zone(TSFZ) Method)

  • 이동주;신건철
    • 한국결정성장학회지
    • /
    • 제1권1호
    • /
    • pp.39-50
    • /
    • 1991
  • 적외선 집중가열 방식의 FZ장치를 이용하여 floation zone 결정 성장기술을 변형한 traveling solvent floating zone(TSFZ)기술로 yttrium iron garnet(YIG: Y3Fe5O12) 단결정을 성장하였다. 또한 TSFZ기술을 확립하기 위하여 단결정 성장시 미치는 여러 가지 영향을 조사하였다. 성장된 YIG결정은 직경이 5~6mm, 길이가 15~36mm이었으며, 이때 성장조건은 성장속도 1mm/h, 회전속도 30rpm, gas flow rate 0.2 1/min, zone aspect ratio 0.9~1, convexity 0.29이었다.

  • PDF

대정제법에 의한 전자재료용 indium정제에 관한 연구 (A study on the indium purification for electronic materials by zone refining)

  • 김백년;김선태;송복식;문동찬
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권2호
    • /
    • pp.130-137
    • /
    • 1994
  • Indium, element of group III, was refined by using zone refining for high purity refinement. We have found the impurities of T1, Zn, Fe, Cd, Pb, Ni, Cu, Sn in the refined indium with ICP-AES, so that 3.9 weight ppm of T1 was reduced to less than 1 ppm, 1.0 weight ppm of Zn was reduced to 0.7 ppm, 2.8 weight ppm of Cd was reduced to 2.5 ppm and 14.0 weight ppm of Sn was reduced to 6.7 ppm with 5 melten zone passes only. 3.9 weight ppm of T1 was reduced to less than 1 ppm, 1.0 weight ppm of Zn was reduced to 0.3 ppm, 2.8 weight ppm of Cd was reduced to less than 1.0 ppm and 14.0 weight ppm of Sn was reduced to 0.4 ppm after vacuum baking with 5 melten zone passes. The surface morpholgy of metal Indium thin film in each conditions showed that porosities were reduced in the front of sampled ingot after vacuum baking with 5 zone melten zone passes. The average electrical resistivity of Indium thin film was reduced from 1.4*10$^{-3}$ .ohm.-cm in Indium origin ingot to 7.9*10$^{-6}$ .ohm.-cm after zone refined with 5 melten zone passes.

  • PDF

GPS를 활용한 여자 필드하키 경기력 분석 (Performance Analysis of Women's Field Hockey Using GPS)

  • 김지응;송주호;박종철;최은영
    • 디지털융복합연구
    • /
    • 제17권10호
    • /
    • pp.461-468
    • /
    • 2019
  • 본 연구는 필드하키 선수를 대상으로 실제경기에서 측정된 GPS데이터를 분류하여 승리경기와 패배경기를 비교 분석하였다. 본 연구를 위하여 여자 필드하키 국가대표선수 23명을 대상으로 A매치 16경기에서 실시간으로 GPS를 선수들이 착용하여 데이터를 수집하였다. 연구결과에 의하면 승리한 경기가 패배한 경기보다 Zone2와 Zone5 구간을 제외한 나머지 구간에서 많이 뛰었으며, Zone3 이상의 구간에서 승리경기와 패배경기의 통계적 차이를 확인하였다. 또한, 6개의 구간을 3개씩 묶어 Zone1~3을 Low-Speed 구간과 Zone4~6을 High-Speed 구간으로 나누어 분석한 결과 유의미한 차이가 없었으며, 가속횟수에서는 고가속 횟수에서 차이가 나타났다. 두 번째로 포지션별로 구간별 이동 거리와 가속횟수를 분석한 결과, 포지션별로 구간별 이동 거리, 저가속 횟수와 고가속 횟수에서 포지션별로 통계적인 차이를 보여 빠른 움직임이 많을수록 경기결과에 차이를 확인했다.

계층분석법을 이용한 적정 수변구역 결정에 관한 연구 (A Study on Determination of an Optimum Riparian Buffer Zone Based on Analytical Hierarchy Process)

  • 한혜진;박석순
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.555-562
    • /
    • 2004
  • This paper presents the development and application of a riparian buffer zone design model(RBZDM). The model was developed as a decision-making tool for watershed management, by integrating geographic information system(GIS) and analytical hierarchy process(AHP) theory. Several factors for watershed management, such as pollution removal capacity, land aquisition cost, distribution of point and non-point pollution sources, and possibility of new pollution source location, were analyzed based on AHP theory. The vegetated buffer zone width was designed using GIS-based riparian buffer analysis. The developed model was applied to the Kyoungan Stream watershed, which is an important part of Paldang lake catchment area. The Kyoungan stream watershed was divided into sixteen subbasins. Six of them belong to the main stem, where the model was applied. Ten alternatives of buffer zone width and five hierarchial levels were designed. The relative importance and the relative preference were computed by pair-wise comparison of evaluation criteria given in hierarchial levels. The buffer zone width was determined by linear function of the given alternatives and relative preferences. From this study, it was determined that the six buffer zone widths of Kyoungan main stems would be 1,594, 1,744, 1,856, 1,782, 1,338, 1,780 meter, from upstream to downstream.