• Title/Summary/Keyword: Zero

Search Result 9,201, Processing Time 0.036 seconds

A Method for Estimating the Lung Clinical Target Volume DVH from IMRT with and without Respiratory Gating

  • J. H. Kung;P. Zygmanski;Park, N.;G. T. Y. Chen
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.53-60
    • /
    • 2002
  • Motion of lung tumors from respiration has been reported in the literature to be as large as of 1-2 cm. This motion requires an additional margin between the Clinical Target Volume (CTV) and the Planning Target Volume (PTV). While such a margin is necessary, it may not be sufficient to ensure proper delivery of Intensity Modulated Radiotherapy (IMRT) to the CTV during the simultaneous movement of the DMLC. Gated treatment has been proposed to improve normal tissues sparing as well as to ensure accurate dose coverage of the tumor volume. The following questions have not been addressed in the literature: a) what is the dose error to a target volume without gated IMRT treatment\ulcorner b) what is an acceptable gating window for such treatment. In this study, we address these questions by proposing a novel technique for calculating the 3D dose error that would result if a lung IMRT plan were delivered without gating. The method is also generalized for gated treatment with an arbitrary triggering window. IMRT plans for three patients with lung tumor were studied. The treatment plans were generated with HELIOS for delivery with 6 MV on a CL2100 Varian linear accelerator with a 26 pair MLC. A CTV to PTV margin of 1 cm was used. An IMRT planning system searches for an optimized fluence map ${\Phi}$ (x,y) for each port, which is then converted into a dynamic MLC file (DMLC). The DMLC file contains information about MLC subfield shapes and the fractional Monitor Units (MUs) to be delivered for each subfield. With a lung tumor, a CTV that executes a quasi periodic motion z(t) does not receive ${\Phi}$ (x,y), but rather an Effective Incident Fluence EIF(x,y). We numerically evaluate the EIF(x,y) from a given DMLC file by a coordinate transformation to the Target's Eye View (TEV). In the TEV coordinate system, the CTV itself is stationary, and the MLC is seen to execute a motion -z(t) that is superimposed on the DMLC motion. The resulting EIF(x,y)is inputted back into the dose calculation engine to estimate the 3D dose to a moving CTV. In this study, we model respiratory motion as a sinusoidal function with an amplitude of 10 mm in the superior-inferior direction, a period of 5 seconds, and an initial phase of zero.

  • PDF

Varietal Differences on Growth Characteristics of Direct-sown Rice under No-tillage Paddy Field (남부지방의 벼 무경운 직파재배에서 품종간 생육특성 비교)

  • Hong, Kwang-Pyo;Kim, Jang-Yong;Kang, Dong-Ju;Shin, Won-Kyo;Choe, Zhin-Ryong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.5
    • /
    • pp.551-557
    • /
    • 1996
  • In order to establish a labour-saved and environment friendly paddy rice system in southern Korea, no-tillage paddy system was proposed and investigated from 1992 to 1993. Basically this system includes a complete return of crop residules into the soil, and zero-tillage. In an effort to minimize labour requirement in rice farming, several cultivars were directly sown and grown under the system and the characteristics of the growth and yield potential of the cultivars were compared with those grown in an ordinary paddy soil. Joryeongbyeo, Dongjinbyeo, Daeyabyeo and Calose rices showed high level of seedling establishment in the no-tillage padddy system. However, the value was significantly lower than in those of the cultivars direct-sown in an ordinary tillage paddy condition. The rice direct-sown and grown under the no-tillage paddy system showed significantly decreased number of tillers per square meter and plant height, but increased ripened grains. The lodging-related characteristics of rice plant, such as band breaking weight, the length of top 3rd ∼4th internodes, the height of weight center, and lodging index, were observed positive aspects in cultivars such as Hwasungbyeo, Hwayongbyeo, Joryeongbyeo, Calose and Calose 76 and being considered adaptable to direct-sown under the no-tillage paddy system.

  • PDF

Development of the Seepage Flow Monitoring Method by the Hydraulic Head Loss Rate (수두손실률에 의한 침투류 감시기법 개발)

  • Eam, Sung-Hoon;Kang, Byung-Yoon;Kim, Ki-Wan;Koo, Ja-Ho;Kang, Shin-Ik;Cha, Hung-Youn;Jung, Jae-Hyun;Cho, Jun-Ho;Kim, Ki-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.5
    • /
    • pp.37-48
    • /
    • 2010
  • In this study, the seepage flow monitoring method by the hydraulic head loss rate was developed for the purpose of application to offshore construction site enclosed by cofferdams in which seepage force varies periodically. The amount of the hydraulic head loss rate newly defined in this graph was in a range between 0 and 1. The zero of the rate means the existence of flow with no seepage resistance. The 1 of the rate means no seepage flow through the ground. The closer to 1 the coefficient of determinant in the hydraulic head loss graph is, the more the ground through which seepage water flows is stable. The closer to 0 the coefficient of determinant in the hydraulic head loss graph is, the more the ground through which seepage water flows was unstable and the higher the possibilities of existence of empty space or of occurrence of piping on the seepage flow pass in the ground is. The hydraulic head loss graph makes it possible to monitor sensitively the situation of seepage flow state, and the graph helps to understand easily the seepage flow state at the specific section on the whole cofferdam.

Temperature Compensation on the Cone Tip Resistance by Using FBG Temperature Transducer (FBG센서를 이용한 콘 선단저항력의 온도영향 보상)

  • Kim, Rae-Hyun;Lee, Jong-Sub;An, Shin-Whan;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.10
    • /
    • pp.31-40
    • /
    • 2009
  • As the measurement of strain-gage type cone penetrometer is influenced by the temperature change during penetration, the temperature is a factor producing an error of the cone tip resistance. In this study, the 0.5 mm diameter temperature transducer and 7 mm diameter micro cone penetrometer are manufactured by using FBG sensors to evaluate the effect of temperature on the cone tip resistance. Design concepts include the cone configuration, sensor installation and the temperature compensation process. The test shows that the tip resistance measured by strain gauge is affected by the temperature change. The error of the tip resistance increases with an increase in temperature change, while the temperature effect on the tip resistance of FBG cone is effectively compensated by using FBG temperature transducer. Temperature compensated tip resistance of the strain gauge cone shows the good matched profile with FBG cone which performs real-time temperature compensation during penetration. This study demonstrates that the temperature compensation by using FBG sensor is an effective method to produce the more reliable cone tip resistance.

Analysis on Importance of Success Factors to Select for the Cloud Computing System Using AHP at Cyber Universities in Korea (AHP를 이용한 국내 사이버대학교 클라우드 컴퓨팅 시스템 구축 성공 요인의 중요도 분석)

  • Kang, Tae-Gu;Kim, Yeong-Real
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.1
    • /
    • pp.325-340
    • /
    • 2022
  • Amid the unprecedented situation of COVID-19 around the world, online education has established itself as an essential element in the era of zero contact and the importance of various content and changes of the system that are appropriate for the era of the 4th industrial revolution has increased. Although universities are making their efforts to combine ICT technologies and design and achieve new systems, the recognition and atmosphere for establishing the cloud computing system are falling short. The purpose of this research importance of success factors of "Building a cloud computing system of cyber university in Korea" by classifying the work characteristics and scale, and to derive and analyze the importance cloud rankings considering the organization and individual dimension. Therefore, this study has drawn 14 major factors in the previous researches and models through the survey on experts with knowledge related to the cloud computing. The analysis was conducted to see what differences there are in factors for the successful establishment of the cloud computing system using AHP. It is expected that the factors for success presented through this study would be used as systemic strategies and tools for the purpose of drawing factors for the success of establishing the private cloud computing system for the higher education institutions and public information systems.

The Research On the Energy Storage System Using SuperCapacitor (슈퍼커패시터를 적용한 에너지 저장시스템 설계에 관한 연구)

  • Kim, IL-Song
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.11
    • /
    • pp.215-222
    • /
    • 2018
  • In this paper, the research on the energy storage system adapting super-capacitor has been performed. The most advanced features compared to the conventional lead-acid battery systems is that it can obtain high power capability due to the super capacitor power characteristics. The suggested system can attain high power in short times and achieve high power quality improvements. The application areas are power quality improvement system, motor start power which requires high power during transient times. The energy conversion system consists of bi-directional converter and inverter and advantages of high speed, high power charging and discharging performances. The design steps for the two loop controller of the bi-directional inverter are suggested and verified by the experiment and manufacturing. The two loop controller design starts from linearized transfer function which is calculated from the state averaging model including state decoupling method. The current controller requirements are 20% overshoot and settling time and voltage controller are no overshoot and settling time which is 10 times longer than current controller. The design is verified from the step input response. The designed controllers have unity power factor characteristics and thus can improve the power quality of the grid. It also has fast response time and zero steady state error.

Comparison of the amount of bacteria according to the number of holes between bristles (칫솔모 사이에 형성한 구멍 수에 따른 세균 양 변화)

  • Kang, Kyung-Hee;Kang, So-Hyeon;Kim, So-Hee;Kim, Ji-Ho;Baek, Su-Jeong;Seo, Hyeon-Ji;Yun, Hae-Yeon;Goong, Hwa-Soo
    • Journal of Korean Academy of Dental Administration
    • /
    • v.6 no.1
    • /
    • pp.19-27
    • /
    • 2018
  • The purpose of this study was to determine the level of toothbrush bacterial growth, whether the dryness of the toothbrush head differs depending on the number of holes in the head, and to use these results as a reference for future toothbrush design. Two-millimeter holes were created on the head of the toothbrushes in groups of three, one, or zero holes. We made the solution with Streptococcus mutans, and the toothbrushes were placed in the solution and agitated. The toothbrushes were shaken to remove moisture and allowed to air-dry. The toothbrush heads were swabbed with saline and then placed in two inoculation groups. The first group was inoculated with a 102 dilution of the S. mutans culture and the second was inoculated with the original culture. After incubation, bacterial colony numbers were measured. The number of holes on the toothbrush head correlated with a decrease in number of cultured bacterial colonies. Our model of a toothbrush head with holes indicated that these holes in the toothbrush head were effective in reducing the level of microbial contamination and that a greater number of holes creates an improved toothbrush sanitation effect. The average number of colonies on the head of toothbrush by number of holes was high, followed by the number of holes 0, 1 and 3, and the average number of colony among toothbrush heads was same. The use of a toothbrush with holes between the toothbrush head indicates that it is effective in reducing the level of microbial contamination between the toothbrush head and toothbrush and the higher the number of holes, the better the effect.

Preparation of ZnO@TiO2 nano coreshell structure by the polymerized complex and sol-gel method (착체중합법과 sol-gel법에 의한 ZnO@TiO2 나노 코아쉘 구조의 제조)

  • Lim, Chang Sung
    • Analytical Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.237-243
    • /
    • 2008
  • Nano core shell structures of $TiO_2$ particles coated on surface of ZnO nanoparticles were prepared by the polymerized complex and sol-gel method. The average particle size of ZnO by the polymerized complex method showed 100 nm and the average particle size of $TiO_2$ by the sol-gel method showed below 10 nm. The average particle size of $ZnO@TiO_2$ nano core shell struture represented about 150 nm. The agglomeration between the ZnO particles using the polymerized complex method was highly controlled by the uniform absorption of $TiO_2$ colloid on the spherical ZnO surfaces. The driving force of heterogeneous bonding between ZnO and $TiO_2$ was induced by the Coulomb force. The ZnO and $TiO_2$ particles electrified with + and - charges, respectively, resulted in strong bonding by the difference of iso-electric point (IEP) when they laid neutrality pH area, depending on the heterogeneous surface electron electrified by the different zeta potential on the pH values.

Free Vibration Analysis of Laminated Composite Stiffened Plates under the In-plane Compression and Shear Loads (면내 압축 및 전단하중을 받는 적층 복합 보강 판의 자유진동해석)

  • Han, Sung-Cheon;Choi, Samuel
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.191-203
    • /
    • 2006
  • The vibration characteristics of composite stiffened laminated plates with stiffener is presented using the assumed natural strain 9-node shell element. To compare with previous research, the stiffened plates are composed of carbon-epoxy composite laminate with a symmetric stacking sequence. Also, the result of the present shell model for the stiffener made of composite material is compared with that of the beam model. In the case of torsionally weak stiffener, a local buckling occurs in the stiffener. In this case, the stiffener should be idealized by using the shell elements. The current investigation concentrates upon the vibration analysis of rectangular stiffened and unstiffened composite plates when subjected to the in-plane compression and shear loads. The in-plane compression affect the natural frequencies and mode shapes of the stiffened laminated composite plates and the increase in magnitude of the in-plane compressive load reduces the natural frequencies, which will become zero when the in-plane load is equal to the critical buckling load of the plate. The natural frequencies of composite stiffened plates with shear loads exhibit the higher values than the case of without shear loads. Also, the intersection, between the curves of frequencies against in-plane loads, interchanges the sequence of some of the mode shapes as a result of the increase in the inplane compressive load. The results are compared with those available in the literature and this result shows that the present shell model for the stiffened plate gives more accurate results. Therefore, the magnitude, direction type of the in-plane shear and compressive loads in laminated composite stiffened plates should be selected properly to control the specific frequency and mode shape. The Lanczos method is employed to solve the eigenvalue problems.

Correction for Membrane Penetration Effect during Isotropic Unloading and Undrained Cyclic Shear Process (등방제하과정과 반복전단과정에서의 멤브레인 관입량 및 보정식에 대한 실험적 고찰)

  • Kwon, Youngcheul;Bae, Wooseok;Oh, Sewook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3C
    • /
    • pp.201-207
    • /
    • 2006
  • Soil tests are generally conducted using a membrane to measure a pore water pressure. However, it has also been recognized that the membrane penetrates into the specimen by the change of the confining pressure, and it results in the erroneous measurement in the pore water pressure and the volumetric strain. This study examined the effectiveness of the correction equation of the membrane penetration on the basis of the experimental data acquired during the isotropic unloading and the cyclic shear process using the hollow cylindrical shear test equipment. The results showed that the membrane penetration by the correction equation could be overestimated when the mean effective stress was lower than 20kPa in this study. The limitations originated from the sudden increase near the zero effective stress, and in order to prevent the overestimation in low effective stress condition, the use of the constant a was proposed in this study. Furthermore, the correction equation for the membrane penetration had to be applied carefully when the initial relative density was high and the density changes were occurred by the relocation of the soil particle by the liquefaction.