• 제목/요약/키워드: Z-Source

검색결과 487건 처리시간 0.029초

The Effects of Online Social Influencers on Purchasing Behavior of Generation Z: An Empirical Study in Vietnam

  • PHAM, Minh;DANG, Thao Yen;HOANG, Thi Hong Yen;TRAN, Thi Thanh Nga;NGO, Thi Huong Quynh
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권11호
    • /
    • pp.179-190
    • /
    • 2021
  • The purpose of this study is to understand the impact of influencers on generation Z (Gen Z) in the online environment. This article has applied the theories of source credibility, TAM, IAM, and TPB to identify influencer characteristics that affect the purchasing behaviors of Gen Z customers. This research was conducted using a Google Form survey with 24 pre-designed questions. A total of 464 valid questionnaires from Gen Z Vietnamese were collected between November 2020 and January 2021. Data was analyzed using partial least squares structural equation modeling (PLS-SEM) with SmartPLS 3 software. The analysis results confirmed that the components of influencer credibility have a positive impact on Gen Z's purchasing behaviors under the mediated influence of argument quality, perceived usefulness, and social influence. Surprisingly, for Gen Z, the influencers' attractiveness has the strongest impact on their online behavior. More specifically, attractiveness plays the most important role in the perceived usefulness and social influence of Gen Z customers, while influencers' expertise has the strongest impact on argument quality delivered to customers. This study provides evidence of a change in the way Gen Z responds to marketing activities. They are more drawn by the attraction of influencers than their expertise.

출력이 직렬 결합된 단상 Quasi Z-소스 AC-AC 컨버터 (A Single-Phase Quasi Z-Source AC-AC Converter with a Series Connection of the Output Terminals)

  • 엄준현;정영국;임영철;최준호
    • 전력전자학회논문지
    • /
    • 제16권5호
    • /
    • pp.415-429
    • /
    • 2011
  • 본 연구에서는 출력이 직렬 연결된 단상 quasi Z-소스 AC-AC 컨버터를 제안하였다. 제안된 시스템은 단상quasi Z-소스 AC-AC 컨버터 2대의 입력 단을 병렬로 연결하고 출력 단을 직렬로 연결한 구조로 되어 있으며, 역상 모드와 동상 모드 별 전류 흐름과 출력전압의 형성 과정을 나타내었다. DSP로 제어되는 실험 시스템을 제작하여 PSIM시뮬레이션 결과와 비교 분석하였다. 그 결과 각 모드별로 듀티 비를 제어하여 원하는 출력 전압을 벅-부스트 할 수 있었다. 컨버터 1대가 단독으로 운전한 경우에 비하여, 각각의 모드에 대하여 부하 저항의 증가에 따른컨버터 효율과 입력 역률을 제안된 방법에 의하여 개선할 수 있었다. 또한 역상 모드의 경우, 일정 부하에서 컨버터의 효율과 입력 역률을 각각 10[%]와 35[%]정도 개선하였으며, 특히 부하 저항이 변동하는 과도상태에서도 일정한 출력 전압을 유지할 수 있었다.

Maximum Boost Space Vector Pulse-Width Modulation Strategy of Z-Source Inverters

  • Kim, Seong Hwan;Park, Jang Hyun
    • 전기전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.73-79
    • /
    • 2015
  • In this paper, maximum boost space vector pulse-width modulation(MBSVPWM) strategy of Z-Source Inverters(ZSIs) is proposed. Conventional space vector pulse-width modulation(SVPWM) method of Voltage Source Inverters(VSIs) is modified to produce unique PWM patterns that realize the maximum boost control of ZSIs. This proposed method minimizes the switching power losses of ZSIs by reducing the numbers of the shoot-through states. Moreover, some switches keep ON state and the switching transitions do not occur during the specific sectors. An experimental system has been built and tested to verify the effectiveness of the proposed strategy.

이득 및 변조지수 제어에 의한 Z-소스 인버터의 출력전압 제어 (Output Voltage Control of Z-Source Inverter by the Modulation Index and Gain Control)

  • 김세진;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.225-227
    • /
    • 2009
  • 본 논문에서는 전압형 3상 ZSI(Z-source Inverter)의 입력전압과 커패시터 충전전압을 검출하고 ZSI의 기본 정의를 이용해 지령전압에 대한 변조지수(Modulation Index)를 결정하는 방법과 출력전압 제어가 가능한 변형된 SVM(공간벡터 변조방식)으로 구성된 알고리즘을 소개한다. 제안된 알고리즘은 ZSI의 이득과 변조지수의 정의를 이용한 간단한 방법으로 변조지수를 변화시켜 출력전압을 일정하게 유지하는 방법이다. PSIM을 통하여 타당성을 입증하였다.

  • PDF

전원전압 센서리스 3상 Z-소스 PWM 컨버터 (Source Voltage Sensorless Three-Phase Z-source PWM Converter)

  • 한근우;수효동;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.115-116
    • /
    • 2012
  • 본 논문에서는 종전의 3상 PWM 컨버터의 문제점을 극복하기 위하여, 시스템의 간소화, 안정화, 비용 상승을 고려하여 3상 Z-소스 PWM 컨버터의 전원전압 센서리스 제어 기법을 제안하였다. 제안한 컨버터는 입력 단 전원전압 센서 없이 입력전류 센서와 DC-link단 전압센서만을 이용하여 전원전압을 추종하고 단위역률을 구현하였으며, 이를 PSIM 시뮬레이션을 통하여 검증 하였다.

  • PDF

변형 공간벡터 변조 기법이 적용된 Bq-ZSI를 이용한 유도전동기 구동시스템 (Bq-ZSI fed Induction Motor Drive System Using Modified Space Vector Modulation)

  • 한상협;김흥근;차헌녕;전태원;노의철
    • 전력전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.9-15
    • /
    • 2018
  • This study investigates a bidirectional quasi-Z-source inverter (Bq-ZSI) system with bidirectional power transfer capability and a modified space vector modulation scheme for reducing the ripple of the inductor current. By replacing the diode in the impedance network with an active switch, the power flow can be bidirectional. The average inductor current of the Bq-ZSI network is negative in the regenerative braking mode, thereby regenerating the power. In addition, modified space vector modulation scheme is applied to the Bq-ZSI to control shoot-through time effectively. A 5 kW prototype is built and tested to implement the proposed system. Experimental results show that the Bq-ZSI system is capable of regenerative braking of the induction motor and that the modified space vector modulation method is efficient.

변형 공간벡터방식을 사용한 Z-Source 인버터의 해석 및 제어 (Analysis and Control of Z-Source Inverter using Modified Space Vector Methods)

  • 전태원;황빈트랜;김흥근;노의철
    • 전력전자학회논문지
    • /
    • 제12권4호
    • /
    • pp.332-338
    • /
    • 2007
  • 본 논문은 ZSI에서 shoot-through 시간을 효율적으로 제어하기 위한 변형 공간전압 변조방식으로 3종류를 제시하였다. 3개의 변형 공간전압 변조방식에 대한 스위칭 패턴과 shoot-through 시간변화에 대한 변조신호의 변화를 분석한다. Shoot-through 시간 제어 범위와 함께 스위칭 패턴 및 변조신호의 평형성 등을 고려하여 최적의 변형 공간전압 변조방식을 선정하였으며, 32비트 DSP를 사용한 실험을 통하여 그 타당성을 확인한다.

Passivity-Based Control System of Permanent Magnet Synchronous Motors Based on Quasi-Z Source Matrix Converter

  • Cheng, Qiming;Wei, Lin
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1527-1535
    • /
    • 2019
  • Because of the shortcomings of the PID controllers and traditional drive systems of permanent magnet synchronous motors (PMSMs), a PMSM passivity-based control (PBC) drive system based on a quasi-Z source matrix converter (QZMC) is proposed in this paper. The traditional matrix converter is a buck converter with a maximum voltage transmission ratio of only 0.866, which limits the performance of the driven motor. Therefore, in this paper a quasi-Z source circuit is added to the input side of the two-stage matrix converter (TSMC) and its working principle has also been verified. In addition, the controller of the speed loop and current loop in the conventional vector control of a PMSM is a PID controller. The PID controller has the problem since its parameters are difficult to adjust and its anti-interference capability is limited. As a result, a port controlled dissipative Hamiltonian model (PCHD) of a PMSM is established. Thereafter a passivity-based controller based on the interconnection and damping assignment (IDA) of a QZMC-PMSM is designed, and the stability of the equilibrium point is theoretically verified. Simulation and experimental results show that the designed PBC control system of a PMSM based on a QZMC can make the PMSM run stably at the rated speed. In addition, the system has strong robustness, as well as good dynamic and static performances.

다이오드 정류기/Z-소스 인버터 시스템의 공통모드 전압 해석 (Analysis of Common Mode Voltages at Diode Rectifier/Z-Source Inverter System)

  • 트란콴빈;전태원;이홍희
    • 전력전자학회논문지
    • /
    • 제14권4호
    • /
    • pp.285-292
    • /
    • 2009
  • 본 논문은 다이오드 정류기와 Z-소스 인버터로 교류전동기 구동 시 암 단락 (shoot-through) 상태와 비 암 단락 상태를 나누어 각각 등가회로를 구성하고 공통모드 전압을 분석한다. 음의 값의 공통모드 전압을 감소시키기 위하여 암 단락 시간 제어와 함께 영전압 벡터인가 구간을 제거하는 변형 공간벡터변조기법을 제시한다. PSIM과 32-비트 DSP를 사용한 실험 및 시뮬레이션 결과를 통하여 음의 공통모드전압이 50%이상 감소됨을 확인하였다.

Z-Source Converter with Maximum Boost Voltage Gain

  • Nguyen, Minh-Khai;Jung, Young-Gook;Lim, Young-Cheol
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 추계학술대회 논문집
    • /
    • pp.112-114
    • /
    • 2008
  • This paper proposes a new two-stage Z-source converter (TSZC). The purpose of the proposed system is to obtain the ac voltage with a maximum boost voltage for fuel cell applications as a renewable energy source. In order to provide a continuous current path, a switching strategy for the dc-ac ZSI and ac-ac ZSC of the proposed system was used. The operation principle, analysis and simulation results of 1.2 kW fuel cell stack were also presented.

  • PDF