• Title/Summary/Keyword: YAG

Search Result 1,405, Processing Time 0.032 seconds

Laser Resurfacing after Facial Free Flap Reconstruction

  • Kim, Beom-Jun;Lee, Yun-Whan;You, Hi-Jin;Hwang, Na-Hyun;Kim, Deok-Woo
    • Medical Lasers
    • /
    • v.8 no.1
    • /
    • pp.7-12
    • /
    • 2019
  • Background and Objectives Skin and soft tissue defects can be treated according to a range of strategies, such as local flap, skin graft, biological dressing, or free flap. On the other hand, free tissue transfer usually leaves a distinct scar with an inconsistency of color or hypertrophy. This problem is highlighted if the defect is located on the face, which could have devastating effects on a patient's psychosocial health. Materials and Methods The authors used an erbium : yttrium-aluminum-garnet (Er:YAG) laser to resurface the free flap skin and match the color with the surrounding facial skin. This study evaluated the effectiveness of laser skin resurfacing on the harmonious color matching of transferred flap. Patients who had undergone laser resurfacing on facial flap skin between January 2014 and December 2018 were reviewed retrospectively. An ablative 2,940-nm fractional Er:YAG laser treatment was delivered to the entire flap skin at 21 J/cm2 with the treatment end-point of pinpoint bleeding. Several months later, the clinical photographs were analyzed. The L*a*b* color co-ordinates of both the flap and surrounding normal skin were measured using Adobe Photoshop. The L*a*b* color difference (ΔE) for the scar and normal surrounding skin were calculated using the following equation: ${\Delta}E=\sqrt{({\Delta}L)^2+({\Delta}a)^2+({\Delta}b)^2}$ Results All five patients were satisfied with the more natural appearance of the flaps. The ΔE values decreased significantly from the pre-treatment mean value of 19.64 to the post-treatment mean value of 11.39 (Wilcoxon signed-rank test, p = 0.043). Conclusion Ablative laser resurfacing can improve the aesthetic outcome of free tissue transfer on the face.

Research on the magnetic confinement of laser-induced plasma (레이저 유도 플라즈마에 대한 자기장 감금의 영향 연구)

  • Eunjoo Hyeon;Yong H. Ghym
    • Journal of IKEEE
    • /
    • v.28 no.1
    • /
    • pp.38-45
    • /
    • 2024
  • Most previous works about magnetic effect on plasma emission were interested in emission enhancement which was useful to various fields of plasma application. On the contrary, the following work is interested in plasma dissipation rarely reported in prior researches and expected to help advance plasma-controlling technique. Nd:YAG laser (1064 nm, 6 ns) was focused on three kinds of metals (Al, Ti and STS) and air. The permanent magnetic field (0.4 T) of Nd2Fe14B magnet was provided passing throughout laser-induced plasma. The spectra of plasma in both the presence and absence of the magnetic field were observed with varying laser power and delay time of the spectrograph. In this work it was uniquely discovered that the plasma always dissipated easily in the presence of magnetic field irrespective of the laser power. With the O I(777.42 nm)-line shape function fitted to Lorentz profile, its half width at half maximum (HWHM) was evaluated to verify that the magnetic field increased the plasma density. It is concluded that magnetic field facilitates not only plasma emission enhancement but also plasma dissipation, increasing recombination rate which is proportional to plasma density.

Change of Regional Myocardial Blood Flow After Transmyocardial Laser Revascularization in Porcine Model of Chronic Myocardial Ischemia (돼지 만성 심근허혈 모델에서 경심근레이저혈류재건술 후 국소 심근 혈류량의 변화)

  • Park, Kay-Hyun;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.662-671
    • /
    • 2001
  • Background: This study was aimed to assess improvement in myocardial perfusion after TMR by measuring regional myocardial blood flow(RMBF) in porcine model of chronic myocardial ischemia. Material and Method: Ameroid ring was placed around the proximal left circumflex coronary artery in fourteen pigs. After 4 weeks, the control group(7 pigs) underwent rethoracotomy only, and the TMR group(7 pigs) underwent Ho:YAG laser TMR at the circumflex territory. After another 4 weeks, the animals were sacrificed for the measurement of RMBF using colored microspheres. The ratio of RMBF between the circumflex territory and the interventricular septum was calculated and compared. Result: At 4 weeks after ameroid constriction, RMBF of the circumflex territory decreased to 46∼89% of RMBF of the interventricular septum. In five of six animals in the TMR group, RMBF of the circumflex territory at 8 weeks after ameroid constriction was higher compared with RMBF at 4 weeks after ameroid constriction. However, the improvement was statistically significant only in two animals. In three of the four animals in the control group, RMBF of the circumflex territory also increased at 8 weeks compared with RMBF at 4 weeks. The degree of increase in RMBF was not different between the control and the TMR groups. Conclusion: In porcine model of chronic myocardial ischemia, the degree of increase in RMBF of the ischemic area after Ho:YAG TMR was not different from the increase by development of native collateral circulation. Perfusion of ischemic myocardium after TMR is not thought to improve to the degree that can be demonstrated by currently available method of assessment such as radioisotope myocardial scintigraphy.

  • PDF

Effects of laser-irradiated dentin on shear bond strength of composite resin (레이저 처리가 상아질과 복합 레진의 결합에 미치는 영향)

  • Kim, Sung-Sook;Park, Jong-Il;Lee, Jae-In;Kim, Gye-Sun;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.520-527
    • /
    • 2008
  • Purpose: This study was conducted to evaluate the shear bond strength of composite resin to dentin when etched with laser instead of phosphoric acid. Material and methods: Recently extracted forty molars, completely free of dental caries, were embedded into acrylic resin. After exposing dentin with diamond saw, teeth surface were polished with a series of SiC paper. The teeth were divided into four groups composed of 10 specimens each; 1) no surface treated group as a control 2) acid-etched with 35%-phosphoric acid 3) Er:YAG laser treated 4) Er,Cr:YSGG laser treated. A dentin bonding agent (Adapter Single Bond2, 3M/ESPE) was applied to the specimens and then transparent plastic tubes (3 mm of height and diameter) were placed on each dentin. The composite resin was inserted into the tubes and cured. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours and the shear bond strength was measured using a universal testing machine (Z020, Zwick, Germany). The data of tensile bond strength were statistically analyzed by one-way ANOVA and Duncan's test at ${\alpha}$= 0.05. Results: The bond strengths of Er:YAG laser-treated group was $3.98{\pm}0.88$ MPa and Er,Cr:YSGG laser-treated group showed $3.70{\pm}1.55$ MPa. There were no significant differences between two laser groups. The control group showed the lowest bond strength, $1.52{\pm}0.42$ MPa and the highest shear bond strength was presented in acid-etched group, $7.10{\pm}1.86$ MPa (P < .05). Conclusion: Laser-etched group exhibited significantly higer bond strength than that of control group, while still weaker than that of the phosphoric acid-etched group.

EFFECT OF LASER IRRADIATION AND FLUORIDE APPLICATION ON REMINERALIZATION OF ERODED PRIMARY DENIAL ENAMEL (침식된 유치 법랑질에 대한 레이저 조사 및 불소도포의 재광화 효과)

  • Yang, Young-Sook;Kim, Dae-Eup;Ra, Ji-Young;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.262-268
    • /
    • 2006
  • The purpose of this in vitro study was to evaluate the remineralizing effects of Nd : YAG laser irradiation and fluorides application on primary tooth enamel eroded by acidic drink. The materials were 30 sound primary teeth with intact smooth enamel surfaces. They were demineralized with Coca-cola at $37^{\circ}C$ for 12 hours and then irradiated by Nd: YAG laser with 6W power, $50mJ/cm^2$ energy density. and 20Hz pulse repetition. After laser irradiation, teeth were treated by three kinds of fluorides : (1) 0.05% NaF solution, (2) 1.23% APF gel and (3) 0.1% fluoride varnish. Diagnodent scores and microhardness (VHN) were measured before and after the each treatment. The results were as follows: 1. Diagnodent scores decreased to 23.51% from the initial after demineralization, and then increased to 37.37% after laser irradiation, and to 51.34% after fluoride treatment. There were significant differences between the total scores of initial, demineralization, laser irradiation and fluoride treatment (P<0.05). There was no significant difference between scores after fluoride treatment according to fluoride types. 2. Microhardness(VHN) decreased to 33.58% from the initial after demineralization and then increased to 43.99% after laser irradiation, and to 51.38% after fluoride treatment. There were significant differences between the total scores of initial, demineralization, laser irradiation and fluoride treatment (P<0.05). There was no significant difference between scores after fluoride treatment according to fluoride types.

  • PDF

Conservation of Removing Surface Contaminants on Silla monument at Jungsung-ri using Nd:YAG Laser Cleaning System (Nd/YAG레이저를 이용한 포항중성리신라비 표면오염물 제거와 보존처리)

  • Lee, Tae Jong;Kim, Sa Dug;Lee, Joo Wan;Oh, Jung Hyeon;Lee, Myeong Seong
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.4
    • /
    • pp.142-153
    • /
    • 2011
  • 'Silla Monument Stone in Jungseong-ri, Pohang' was discovered in Pohang City, Gyeongsangbuk Province of Korea in 2009. The monument stone with irregular shape has dimensions of maximum height of 105cm, width of 47.6~49.6cm, thickness of 13.8~14.7cm and weight of 115kg. The results of monument stone was found to be granitite. Conservation treatment procedure was carried out in the order of production of Weathering map, cleaning of surface pollutants, consolidation using ethyl silicate. Black pollutant(crust) that covered more than 60% of the surface was analyzed first in order to remove the pollutants on the surface of the monumental stone by cleaning of surface pollutants using laser. The purpose on analysis was not only to verify the pollutants on the stone but also to carry out preliminary cleaning by securing rocks with same pollutant as the monumental stone. As the results of analysis using p-XRF(PMI. INNOV-X, USA) on the site, high level of Mn and Fe were detected, and the analysis of small section that had been fallen off with SEM/EDX for the purpose of quantitative analysis also detected high level of Mn. The Similar contaminants on Stone secured in the manner described above were made into 10 samples ($5cm{\times}5cm$) and was subjected to preliminary cleaning by Nd-YAG Laser(Laser&Physics, Korea). The results of surface observation through portable microscope during cleaning revealed that the power of 460mJ, wavelength of 1064nm and irradiation frequency of 1,800~2,300 per $25cm^2$ were most effective. Evaluation on the preservative treatment was made through confirmation of the extent of removal through color-difference meter measurement and component analysis prior to and following removal of the pollutants. As the result of color-difference meter measurement increase in the brightness was evidenced by the increase in the brightness ($L^*$)value from 33 to 49, and it was possible to ascertain the reduction in the pollutants as the content of Mn was reduced by about 80% from $50,000{\pm}5,000ppm$ to $10,000{\pm}2,000pmm$ from the result of component analysis.

Step Pulse Shaping Technique for Nd:YAG Laser Using a Multi-Switching Method

  • Kwak, Su-Young;Park, Jin-Young;Kim, Su-Weon;Min, Byoung-dae;Chung, Hyun-ju;Kim, Hee-je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.2
    • /
    • pp.55-59
    • /
    • 2004
  • Throughout manufacturing processes, pulse shaping is required for material processing and it is regarded as an important (actor according to the specific characteristics of materials. Therefore, this study suggests a highly appropriate pulse shaping technique using a multi-switching method. This is a pulse superposition method in which one flash lamp can consecutively turn on by the double switching of the discharging system. It is possible to construct a variety of pulse shapes and pulse widths by the consecutive trigger of the silicon-controlled rectifiers (SCR) of a PIC (program integrated circuit) one-chip microprocessor. The use of this technique can provide a number of advantages to people who require suitable pulse shaping for particular applications such as welding, cutting, and drilling.

Laser Welding Quality Monitoring with an Optical Fiber System

  • Kim, Jin-Tae;Kim, Do-Hyoung;Chung, Chin-Man;Baik, Sung-Hoon;Park, Seung-Kyu;Kim, Min-Suk
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.193-196
    • /
    • 2003
  • We have developed a laser welding monitoring system to monitor laser welding process conditions such as sample feed rate, laser focal position, and laser power. A 2 ㎾ Nd:YAG CW laser beam has been applied to the welding of a stainless steel plate (SUS306) to investigate the welding monitoring. Theradiation signal from the weld pool was guided back through the focusing optics and the laser delivery fiber, and measured by a photo detector. By changing the focus of the laser beam along the z-direction, the penetration depth of the welding material has been measured. That shows the penetration depth depends on the frequency fluctuations of the plume signals which can be used in welding quality control.

Quantum Interference Effects on Optical Amplification and the Index of Refraction in a Four-Level System

  • Zhang, Hui-Fang;Wu, Jin-Hui;Gao, Jin--Yue
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.174-179
    • /
    • 2003
  • We construct a four-level system where a metastable state is included in an $Er^{3+}$ Doped Yttrium aluminum garnet (YAG) crystal. Because of the action of the coherent field, the traditional light amplification with inversion can be exhibited with remarkable variation. As a result, we propose a method to achieve the gain equalization by atomic coherence. At the same time, we find that the high index of refraction accompanied by vanishing absorption can also be reached in this model. We also find that a higher index of refraction with zero absorption can be easily obtained when the coherent field is off resonance.

UV emission characterization of ZnO thin films depending on the variation of oxygen pressure (분위기 산소압변화에 따른 ZnO박막의 UV발광 특성분석)

  • Bae, Sang-Hyuck;Lee, Sang-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1523-1525
    • /
    • 1999
  • ZnO is a wide-bandgap II-VI semiconductor and has a variety of potential application. ZnO exhibits good piezoelectric, photoelectric and optic properties, and is good for a electroluminescence device. ZnO films have been deposited at (0001) shappire by PLD technique. Chamber was evacuated by turbomolecular pump to a base pressure of $1{\times}10^{-6}$ Torr Nd:YAG pulsed laser was operated at ${\lambda}=355nm$. The ZnO films were deposited at oxygen pressures from base to 500 mTorr. The substrate temperatures was increased from $200^{\circ}C$ to $700^{\circ}C$. At aleady works, UV emission and green-yellow PL was observed. In this work, ZnO films showed UV, violet, green and yellow emissions. UV emission was enhanced by increasing partial oxygen pressure. We investigated relationship between partial oxygen pressure and UV emission.

  • PDF