• Title/Summary/Keyword: Y-Stent

Search Result 472, Processing Time 0.035 seconds

The Usefulness and Safety of Natural Stent in a Canine Model of Tracheal Stenosis (Nd-YAG laser를 이용한 기관협착 동물모델에서 Natural 스텐트의 안전성 및 유효성 -Dumon 스텐트와의 비교 실험-)

  • Kim, Ho-Joong;Koh, Won-Jung;Suh, Gee-Young;Chung, Man-Pyo;Kim, Jhin-Gook;Suh, Soo-Won;Kwon, O-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.431-438
    • /
    • 2002
  • Background : In order to investigate the usefulness and safety of Natural Stent, we performed this study in a canine model of tracheal stenosis induced using Nd-YAG laser. Materials and Methods : After tracheal stenosis was induced in 12 Mongrel dogs using Nd-YAG laser, either Dumon (n=6) or Natural (n=6) stent was inserted into the trachea. To assess the degree of stent migration and mucostasis, bronchoscopy was performed every week for 4 weeks, after which all stents were removed. One week after stent removal, tracheal stenosis was evaluated by bronchoscopy. Results : The degree of stent migration was not different between the dogs with Dumon stent ($3.0{\pm}0.8$) and those with Natural ($2.0{\pm}1.0$), nor was the degree of mucostasis, at Dumon ($1.7{\pm}0.5$) and Natural Stent ($1.5{\pm}0.6$), respectively. One week after stent removal, the degree of tracheal stenosis was not different between the Dumon ($1.5{\pm}0.5$) and the Natural group ($1.0{\pm}0.4$). In addition, there was no death and the degree of tracheal stenosis remained always within the safe limit (less than 2.0) in all animals. Conclusion : In a canine model of tracheal stenosis induced using Nd-YAG laser, the usefulness and safety of Natural Stent were similar to those of Dumon Stent. A clinical trial is necessary to document the usefulness and safety of Natural Stent in patients with tracheal stenosis.

The Verification of Computer Simulation of Nitinol Wire Stent Using Finite Element Analysis (유한요소법을 이용한 나이티놀 와이어 스텐트의 전산모사 실험 데이터 검증)

  • Kim, Jin-Young;Jung, Won-Gyun;Jeon, Dong-Min;Shin, Il-Gyun;Kim, Han-Ki;Shin, Dong-Oh;Kim, Sang-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.139-144
    • /
    • 2009
  • Recently, the mathematical analysis of stent simulation has been improved, with the help of development of various tool which measure mechanical property and location of stent in artery. The most crucial part of the stent modeling is how to design ideal stent and to evaluate the interaction between stent and artery. While there has been great deal of researches on the evaluation of the expansion, stress distribution, deformation of the stent in terms of the various parameters, few verification through computer simulation has been performed about deformation and stress distribution of the stent. In this study, we have produced the corresponding results between experimental test using Universal Testing Machine and computer simulation for the ideal model of stent. Also, we have analyzed and compared stress distribution of stent in the cases of that with membrane and that without membrane. The results of this study would provide minimum change of plan and good quality for ideal stent replacing damaged artery through the analysis using computer simulation in the early stage of stent design.

  • PDF

Deduction and Verification of Optimal Factors for Stent Structure and Mechanical Reaction Using Finite Element Analysis (스텐트의 구조 및 기계적인 반응에 대한 최적인자 도출과 유한요소해석법을 통한 검증)

  • Jeon, Dong-Min;Jung, Won-Gyun;Kim, Han-Ki;Kim, Sang-Ho;Shin, Il-Gyun;Jang, Hong-Seok;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.201-208
    • /
    • 2010
  • Recently, along with technology development of endoscopic equipment, a stent has been developed for the convenience of operation, shortening of recovery times, and reduction of patient's pain. To this end, optimal factors are simulated for the stent structure and mechanical reaction and verified using finite element analysis. In order to compare to present commercialized product such as Zilver (Cook, Bloomington, Indiana, USA) and S.M.A.R.T (Cordis, Bridgewater Towsnhip, New Jersey, USA), mechanical impact factors were determined through Taguchi factor analysis, and flexibility and expandability of all the products including ours were tested using finite element analysis. Also, important factors were sought that fulfill the optimal condition using central composition method of response surface analysis, and optimal design were carried out based on the important factors. From the centra composition method of Response surface analysis, it is found that importat factors for flexibility is stent thickness (T) and unit area (W) and those for expandability is stent thickness (T). In results, important factors for optimum condition are 0.17 mm for stent thickness (T) and $0.09\;mm^2$ for unit area (W). Determined and verified by finite element analysis in out research institute, a stent was manufactured and tested with the results of better flexibility and expandability in optimal condition compared to other products. Recently, As Finite element analysis stent mechanical property assessment for research much proceed. But time and reduce expenses research rarely stent of optimum coditions. In this research, Important factor as mechanical impact factor stent Taguchi factor analysis arrangement to find flexibility with expansibility as Finite element analysis. Also, Using to Center composition method of Response surface method appropriate optimized condition searching for important factor, these considering had design optimized. Production stent time and reduce expenses was able to do the more coincide with optimum conditions. These kind of things as application plan industry of stent development period of time and reduce expenses etc. be of help to many economic development.

Extraction of Vessel Width in Coronary Angiography Images (관상동맥 조영영상에서의 혈관 폭 추출)

  • Kim, Seong-Hu;Lee, Ju-Won;Kim, Joo-Ho;Choi, Dae-Seob;Lee, Gun-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.11
    • /
    • pp.2538-2543
    • /
    • 2012
  • The Percutaneous Coronary intervention is a typical way of testing which could be performance to treat a stenosed region by inserting a stent using catheter. In this case, choosing the best stent amongst various kinds of stent for performing an intervention is the most difficult process. For the reason, a width of the blood vessel which is stenosed must be correctly measured to help an operator choose right size of stent. So based on pixel, a width of the blood vessel measured by using the way of Euclidean distance after designing a center-line of vessel from a certain point assigned by operator is shown as a profile in this study. This study would be used as a goof reference for operators when choosing right size of stent.

Endovascular Treatment of Wide-Necked Intracranial Aneurysms : Techniques and Outcomes in 15 Patients

  • Kim, Jin-Wook;Park, Yong-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.2
    • /
    • pp.97-101
    • /
    • 2011
  • Objective : It is technically difficult to treat wide-necked intracranial aneurysms by the endovascular method. Various tools and techniques have been introduced to overcome the related technical limitations. The purpose of this study was to evaluate the radiologic and clinical results of widenecked intracranial aneurysm treatment using the endovascular method. Methods : Fifteen aneurysms in 15 patients were treated by the endovascular method from October 2009 to August 2010. Seven patients presented with subarachnoid hemorrhage (SAH), seven patients had unruptured aneurysms, and one patient had an intracerebral hemorrhage and intraventricular hemorrhage due to an incompletely clipped aneurysm. The mean dome-to-neck ratio was 1.1 (range, 0.6-1.7) and the mean height-to-neck ratio was 1.1 (range, 0.6-2.0). We used double microcatheters instead of a stent or a balloon for the first trial. When we failed to make a stable coil frame with two coils, we used a stent-assisted technique. Results : All aneurysms were successfully embolized. Eleven aneurysms (73%) were embolized by the double microcatheter technique without stent insertion, and four aneurysms (27%) were treated by stent-assisted coil embolization. One case had subclinical procedure-related intraoperative hemorrhage. Another case had procedure-related thromboembolism in the left distal anterior cerebral artery. During the follow-up period, one patient (7%) had a recanalized aneurysmal neck 12 months after coil embolization. The recurrent aneurysm was treated by stent-assisted coil embolization. Conclusion : We successfully treated 15 wide-necked intracranial aneurysms by the endovascular method. More clinical data with longer follow-up periods are needed to establish the use of endovascular treatment for wide-necked aneurysm.

The Developing Trend in Bioresorbable Stent for Treatment of Coronary Artery Disease (관상동맥질환 치료를 위한 생체흡수형스텐트의 개발 동향)

  • Jeong, Gyeong-Won;Kim, Tae-Hoon;Nah, Jae-Woon;Park, Jun-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.29 no.5
    • /
    • pp.497-502
    • /
    • 2018
  • The coronary artery disease (CAD) is rapidly increasing such as angina pectoris and atherosclerosis. The CAD is induce by cholesterol and calcium like plaque absortion to artery wall. The percutaneouss coronary intervention is non-invasive treatment that narrowed-artery is expand by using balloon catheter and bare metallic stent. The metallic stents have been effective in reducing the dead by coronary artery disease, but the permanent presence of the metallic stent has been associated with persistent inflammation, and incidence of late thrombosis. Therefore, development bioresorbable vascular scaffold (BRS) is rapidly increasing for treatment of long-term complications and arterial restenosis by permanentmetal prosthesis such as stent. The review discusses the BRS trend for successfully development.

Endovascular Stroke Therapy Focused on Stent Retriever Thrombectomy and Direct Clot Aspiration : Historical Review and Modern Application

  • Kang, Dong-Hun;Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.3
    • /
    • pp.335-347
    • /
    • 2017
  • Intravenous recombinant tissue plasminogen activator had been the only approved treatment for acute ischemic stroke since its approval in 1995. However, the restrictive time window, numerous contraindications, and its low recanalization rate were all limitations of this modality. Under those circumstances, endovascular stroke therapy went through a great evolution during the past two decades of intravenous thrombolysis. The results of the 2013 randomized trials for endovascular stroke therapy were neutral, although they were limited by insufficient imaging screening at enrollment, early-generation devices with less efficacy, and treatment delays. Huge progress was made in 2015, as there were five randomized clinical trials which all demonstrated the safety and efficacy of endovascular stroke treatment. Despite differences in detail patient enrollment criteria, all 5 trials employed key factors for good functional recovery; (1) screening with non-invasive imaging to identify the proximal occlusion and exclude a large infarct core, (2) using highly effective modern thrombectomy devices mainly with stent retriever, and (3) establishment of a fast workflow to achieve effective reperfusion. The results of those trials indicate that modern thrombectomy devices can allow for faster and more effective reperfusion, which can lead to improved clinical outcomes compared to intravenous thrombolysis alone. These advances in mechanical thrombectomy are promising in the global fight against ischemic stroke-related disability and mortality. Two current mainstreams among such mechanical thrombectomy techniques, "stent retriever thrombectomy" and "direct clot aspiration", are the topic of this review. Stent retriever thrombectomy using Solitaire and Trevo retriever will be firstly discussed. And, the commonalities and the differences between two major clot aspiration thrombectomy techniques; a direct aspiration first pass technique (ADAPT) and forced arterial suction thrombectomy (FAST), will be additionally explained. Finally, details regarding the combination of direct clot aspiration and stent retriever thrombectomy, the switching strategy and the Solumbra technique, will be described.

Effectiveness of Endoscopic Dilatation & Silicone Stent Insertion for Tracheobronchial stenoses : Preliminary study (기관-기관지 협착에서 내시경적 확장술 및 실리콘 스텐트의 유용성 : 예비보고)

  • Lee, Kyong-Soo;Park, Dong-Wook;Kim, Kyu-Hun;Kim, Jae-Wook;Koh, Yoon-Woo;Kim, Do-Jin;Lee, Seung-Won
    • Korean Journal of Bronchoesophagology
    • /
    • v.15 no.1
    • /
    • pp.50-55
    • /
    • 2009
  • Objectives: Endoscopic airway dilatation and stenting has been developed to treat the airway stenosis without potential morbidities of open surgery. We report the clinical results of endoscopic airway dilatation with silicone stenting in patients with posttuberculous bronchial stenosis(PTBS) and with severe main tracheal stenosis who have poor general conditions Methods : A prospective observation study of five patients, who have undergone endoscopic airway dilatation and silicone stenting between Feb 2007 and Feb 2009. A total of twelve patients were treated with endoscopic airway dilatation, among them 5 patients were included in this study. three patients were treated with newly designed silicone stent (Natural stent: TNO Co., Seoul, South Korea) because of poor surgical conditions and longer stenotic segment Results: 3 patients were grade III PTBS, and the other 2 patients were grade IV post tracheotomy main tracheal stenosis. One patient of PTBS were treated with silicone stent following endoscopic dilatation because of longer stenotic segment. Two patients of main tracheal stenosis patients were treated with silicone stent because of tracheal lumen collapse. There was no severe postoperative complications except mild granulation tissue formations Conclusions : Endoscopic dilatation including silicone stenting could be a useful method for treating patients with PTBS, and for main tracheal stenosis patients with poor general surgical conditions

  • PDF

A Study on Optimal Shape of Stent by Finite Element Analysis (유한요소 해석을 이용한 스텐트 최적형상 설계)

  • Lee, Tae-Hyun;Yang, Chulho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.1-6
    • /
    • 2017
  • Stents are widely used as the most common method of treating coronary artery disease with implants in the form of a metal mesh. The blood flow is normalized by inserting a stent into the narrowed or clogged areas of the human body. In this study, the mechanical characteristics of a stent are investigated according to the variations of its design parameters by the Taguchi method and finite element analysis. A stent model of the Palmaz-Schatz type was used for the analysis. In the analysis, an elasto-plastic material model was adopted for the stent and a hyper-elastic model was used for the balloon. The main interest of this study is to investigate the effects of the design parameters which reduce the possibility of restenosis by adjusting the recoil amount. A Taguchi orthogonal array was constructed on the model of the stent. The thickness and length and angle of the slot were selected as the design parameters. The amounts of radial recoil and longitudinal recoil were calculated by finite element analysis. The statistical analysis using the Taguchi method showed that optimizing the shape of the stent could reduce the possibility of restenosis. The optimized shape showed improvements of recoil in the radial and longitudinal directions of ~1% and ~0.1%, respectively, compared to the default model.

Comparative Analysis of Endovascular Stroke Therapy Using Urokinase, Penumbra System and Retrievable (Solitare) Stent

  • Choi, Jae-Hyung;Park, Hyun-Seok;Kim, Dae-Hyun;Cha, Jae-Kwan;Huh, Jae-Taeck;Kang, Myongjin
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.5
    • /
    • pp.342-349
    • /
    • 2015
  • Background : Higher reperfusion rates have been established with endovascular treatment for acute ischemic stroke patients. There are limited data on the comparative performance of mechanical thrombectomy devices. This study aimed to analyse the efficacy and safety of the stent retriever device (Solitaire stent) by comparing procedure time, angiographic outcome, complication rate and long term clinical outcome with previous chemical thrombolysis and mechanical thrombectomy using penumbra system. Method : A retrospective single-center analysis was undertaken of all consecutive patients who underwent chemical thrombolysis and mechanical thrombectomy using Penumbra or Solitaire stent retriever from March 2009 to March 2014. Baseline characteristics, rate of successful recanalization (modified Thrombolysis in Cerebral Infarction score 2b-3), symptomatic intracerebral hemorrhage, procedure time, mortality and independent functional outcomes ($mRS{\leq}2$) at 3 month were compared across the three method. Results : Our cohort included 164 patients, mechanical thrombectomy using stent retriever device had a significant impact on recanalization rate and functional independence at 3 months. In unadjusted analysis mechanical thrombectomy using Solitaire stent retriever showed higher recanalization rate than Penumbra system and chemical thrombolysis (75% vs. 64.2% vs. 49.4%, p=0.03) and higher rate of functional independence at 3 month (53.1% vs. 37.7% vs. 35.4%, p=0.213). In view of the interrelationships between all predictors of variables associated with a good clinical outcome, when the chemical thrombolysis was used as a reference, in multiple logistic regression analysis, the use of Solitaire stent retriever showed higher odds of independent functional outcome [odds ratio (OR) 2.62, 95% confidence interval (CI) 0.96-7.17; p=0.061] in comparison with penumbra system (OR 1.57, 95% CI 0.63-3.90; p=0.331). Conclusion : Our initial data suggest that mechanical thrombectomy using stent retriever is superior to the mechanical thrombectomy using penumbra system and conventional chemical thrombolysis in achieving higher rates of reperfusion and better outcomes. Randomized clinical trials are needed to establish the actual benefit to specific patient populations.