• Title/Summary/Keyword: XRAY

Search Result 63, Processing Time 0.02 seconds

Development and Evaluation of Non-Hydrous Skin Analogue Liquid Crystal using Thermo-Sensitivity Smart Sensor

  • Yoo, Kwang-Ho;Hong, Jae-Hwa;Eun, So-Hee;Jeong, Tae-Hwa;Jeong, Kwan-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.367-374
    • /
    • 2014
  • In this study, skin permeation enhancement was confirmed by designing it to have a structure and composition similarity to the intercellular lipids that improve miscibility with skin by cross-linked lipids poloxamer. The cross-linked lipids poloxamer was synthesized and analyzed by 1H NMR that structure dose had conjugated pluronic with ceramide3. Active component is released by modification of liquid crystal structure because PPO part, large-scale molecule block of pluronic, has hydrophobic nature at skin temperature of $35^{\circ}C$. Conjugated pluronic with ceramide3 was synthesized using Pluronic F127 and p-NPC (4-nitrophenyl chloroformate) at room temperature yielded 89%. Pluronic(Ceramide 3-conjugated Pluronic) was synthesized by reaction of p-NP-Pluronic with Ceramide3 and DMAP. The yield was 51%. This cross-linked lipids poloxamer was blended and dissolved at isotropic state with skin surface lipids, phospholipid, ceramide, cholesterol and anhydrous additive solvent. Next step was preceded by ${\alpha}$-Transition at low temperature for making the structure of Meso-Phase Lamella, and non-hydrous skin analogue liquid crystal using thermo-sensitivity smart sensor, lamellar liquid crystal structure through aging time. For confirmation of conjugation thermo-sensitivity smart sensor and non-hydrous skin analogue liquid crystal, structural observation and stability test were performed using XRD(Xray Diffraction), DSC(Differential Scanning Calorimetry), PM (Polarized Microscope) And C-SEM (Cryo-Scanning Electron Microscope). Thermo-sensitivity observation by Franz cell revealed that synthesized smart sensor shown skin permeation effect over 75% than normal liquid crystal. Furthermore, normal non-hydrous skin analogue liquid crystal that not applied smart sensor shown similar results below $35^{\circ}C$ of skin temperature, but its effects has increased more than 30% above $35^{\circ}C$.

Effect of Bone Demineralization and Tibia Lead on Blood Lead in Retired Lead Workers (퇴직한 납 취급 근로자들에서 골밀도 저하와 경골납량이 혈중납량에 미치는 영향)

  • Kim, Nam-Su;Kim, Jin-Ho;Kim, Hwa-Seong;Kim, Hui-Seon;Lee, Seong-Su;Todd, Andrew C.;Lee, Byeong-Guk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.324-333
    • /
    • 2006
  • This study was designed to investigate the effect of bone demineralization and tibia lead on blood lead in retired lead workers. Two hundred thirty five(126 females and 109 males) retired lead workers who worked in 4 different lead factories and 101 non-occupationally lead exposed subjects(51 females and 51 males) were recruited from March 2004 to October 2004. Bone mineral density(BMD) was measured at left calcaneous bone area by broadband ultrasound attenuation(BUA) method with QUS-2(Metra Biosystems Inc, USA). The BUA value transformed into T-score by WHO standard conversion criteria. Tibia bone lead was measured for skeletal bone lead with K-xray fluorescence(K-XRF) and blood lead was analyzed with flameless atomic spectrophotometer. Hemoglobin, hematocrit, serum calcium and iron were also analyzed. In addition, information for smoking and drinking status and basic personal data such as age, gender and lead exposure were also collected using questionnaire inquiry. Blood lead was correlated with tibia lead (r=0.664) and these two variables were negatively correlated with BMD in bivariate analysis. BMD showed significant main effect on the change of blood lead independent to tibia lead without any effect modification of age or gender; the one T-score unit decrease of mineral bone density made $0.43{\mu}g/dl$ increase of blood lead. On the other hand, tibia lead showed effect modification with gender on blood lead; the slope of tibia lead on blood lead in male was steeper than in female and crossed at around zero of tibia lead. In the multiple regression analysis of blood lead and tibia lead on BMD after adjustment of related covariates, only blood lead showed statistically significant effect on BMD. This study confirmed that BMD and blood lead were significantly associated. To verify the causal association of BMD on blood lead and vice versa, further longitudinal studies are needed.

Sacroiliac Joint/Sacrum Uptake Ratio Measured by Quantitative Sacroiliac Joint Scintigraphy (골(骨)스캔을 이용(利用)한 천장관절(薦腸關節)/천골섭취비(薦骨攝取比)의 정량적(定量的) 측정(測定))

  • Lee, Young-Yiul;Park, Seon-Yang;Lee, Myung-Chul;Choi, Sung-Jae;Cho, Bo-Youn;Choe, Kang-Won;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.2
    • /
    • pp.63-70
    • /
    • 1982
  • To evaluate the diagnostic usefulness and significance of quantitative sacroiliac joint scintigraphy in the assessment of sacroiliitis, we measured Sacroiliac Joint/Sacrum Uptake Ratio(SIS Ratio) by region of interest(ROI) method using $^{99m}Tc-methylene$ diphosphonate. The observed results were as follows: 1. Using ROI method, the SIS ratios for the control group of 65 persons were $1.05{\pm}0.08$(left) and $1.06{\pm}0.07$(right) which were narrower in range than those of slice method $(mean{\pm}S.D.)$. 2. The effects of age, gender and laterality on SIS ratio were not significant. 3. In left side, one of 6 patients with rheumatoid arthritis had SIS ratio in excess of 2 standard deviation of normal control group, and remainder had SIS ratios within normal limit. In right side, 3 patients had SIS ratios in excess of 2 standard deviation of normal control group, and remainder, within normal limit. 4. In both sacroiliac joint, 2 of 3 patients having sacroiliitis clinically with Reiter's syndrome whose pelvis A-P X-ray findings showed normal had high SIS ratios (left/right; 1.31/1.69, 1.90/1.80), but SIS ratio of one patient who had no evidence of sacroiliitis clinically was within normal limit. 5. In 6 patients with ankylosing spondylitis in both sacroiliac joints, 4 whose pelvis A-P Xray findings showed severe sclerotic change of sacroiliac joints had SIS ratio within normal limit or below that of normal control group, and SIS ratios of 2 patients whose pelvis A-P X-ray findings showed were increased. 6. 4 of 5 patients with low back pain of which cause could not be evaluated clinically and radiologically had SIS ratios in excess of that of normal control group. It would be concluded that quantitative sacroiliac joint scintigraphy is useful and sensitive screening method in the diagnosis as well as in the assessment clinical activity of sacroiliitis.

  • PDF

Effect of increased blood and tibia lead on the change of bone mineral density in retired male lead workers (과거의 직업적 납 노출에 의한 혈중납 및 골중납의 증가가 남성 골밀도 변화에 미치는 영향)

  • Kim, Nam-Soo;Lee, Sung-Soo;Kim, Hee-Seon;Todd, Andrew C.;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.19-28
    • /
    • 2010
  • This study was designed to investigate the effect of increased blood and tibia lead on the change of bone mineral density in retired male lead workers. One hundred nine retired male lead workers who worked in 4 different lead industries and 51 nonoccupationally lead exposed male subjects were recruited from March 2004 to October 2004. Bone mineral density(BMD) was measured by broadband ultrasound attenuation(BUA) at left calcaneous bone area with broadband ultrasound attenuation method of QUS-2(Metra Biosystems Inc, USA). Tibia bone lead was measured for skeletal bone lead with K-xray fluorescence(K-XRF) and blood lead was analyzed with flameless atomic spectrophotometer. Hemoglobin, hematocrit, serum calcium and iron were also analyzed. In addition, information for smoking and drinking status and basic personal data such as age and lead exposure were also collected using questionnaire inquiry. Blood lead was correlated with tibia lead (r=0.711) and these two variables were negatively correlated with BUA in bivariate analysis. BUA and tibia lead showed significant main effects on the change of blood lead after adjusting covariates. The effect modification by the level of BMD (low: lower than the median of BUA and high: higher than the median of BUA) was observed between the association of tibia lead and blood lead after adjustment of covariates. The subjects who had higher BMD seemed to have lower blood lead by the increase of tibia lead than those of lower BMD. In the multiple regression analysis of blood lead and tibia lead on BUA after adjustment of covariates, only blood lead showed statistically significant effect on BUA. This study confirmed that BMD and blood lead were significantly associated. To verify the causal association of BMD on blood lead and vice versa, further longitudinal studies are needed.

Three-dimensional Structure Analysis of $SmZn_{0.67}Sb_2$ by Transmission Electron Microscopy (투과전자현미경을 이용한 $SmZn_{0.67}Sb_2$의 3차원적 구조 분석)

  • Kim, Jin-Gyu;Kang, Sung-Kwon;Kim, Wan-Cheol;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.34 no.4
    • /
    • pp.255-264
    • /
    • 2004
  • The three-dimensional (3D) structure of an inorganic crystal, $SmZn_{0.67}Sb_2$ (space group P4/nmm, $a=4.26{\AA}\;and\;c=10.37{\AA}$) was solved by electron crystallography. High resolution electron microscopy (HREM) images from 3 different major zone axes and selected-area electron diffraction patterns from 16 different zone axes were combined to obtain a 3D information. A crystallographic image processing (CIP) of HREM images was used for more accurate determination of the crystal structure. As a result of this electron crystallography, average phase errors (${\Phi}_{res}$) of [001], [100] and [110] HREM images are $17.0^{\circ},\;8.3^{\circ}\;and\;21.9^{\circ}$, respectively. Xray crystallography of $SmZn_{0.67}Sb_2$ has attempted to compare accuracy of the structure determination by electron crystallography, which resulted in the cell parameters of $a=4.2976(6){\AA}\;and\;c=10.287(2){\AA}$, and the R-factor ($R_{sym}$) of 4.16%.

R.F. plasma assisted CVD로 합성한 BN, BCN 박막의 물성과 구조 연구

  • 김홍석;백영준;최인훈
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.114-114
    • /
    • 1999
  • Boron nitride (BN)는 매우 뛰어난 물리적, 화학적 성질을 가지고 있는 재료로 많은 연구가 진행되고 있다. hexagonal 형태의 hBN의 경우 큰 전기 저항과 열 전도도를 가지고 있고 열적 안정성을 가지고 있어 반도체 소자에서 절연층으로 쓰일 수 있다. 또한 X-ray와 가시광선을 투과시키기 때문에 X-ray와 가시광선을 투과시키기 때문에 X-ray lithography이 mask 기판으로 사용될 수 있다. Boron-carbon-nitrogen (BCN) 역시 뛰어난 기계적 성질과 투명성을 가지고 있어 보호 코팅이나 X-ray lithography에 이용될 수 있다. 또한 원자 조성이나 구성을 변화시켜 band gap을 조절할 수 있는 가능성을 가지고 있기 때문에 전기, 광소자의 재료로 이용될 수 있다. 본 연구에서는 여러 합성 조건 변화에 따른 hBN 막의 합성 거동을 관찰하고, 카본 농도변화에 따른 BCN 막의 기계적 성질과 구조의 변화, 그리고 실리콘 첨가에 의한 물성 변화를 관찰하였다. BN박막은 실리콘 (100) 기판 위에 r.f. plasma assisted CVD를 이용하여 합성하였다. 합성 압력 0.015 torr, 원료 가스로 BCl3 1.5 sccm, NH3 6sccm을 Ar 15 sccm을 사용하여 기판 bias (-300~-700V)와 합성온도 (상온~50$0^{\circ}C$)를 변화시켜 BN막을 합성하였다. BCN 박막은 상온에서 기판 bias를 -700V로 고정시킨 후 CH4 공급량과 Ar 가스의 첨가 유무를 변화시켜 합성하였다. 또한 SiH4 가스를 이용하여 실리콘을 함유하는 Si-BCN 막을 합성하였다. 합성된 BN 막의 경우, 기판 bias와 합성 온도가 증가할수록 증착속도는 감소하는 경향을 보여 주었다. 기판 bias와 합성온도에 따른 구조 변화를 SEM과 Xray로 분석하였다. 상온에서 합성한 경우는 표면형상이 비정질 형태를 나타내었고, X-ray peak이 거의 관찰되지 않았다. 합성온도가 증가하게 되면 hBN (100) peak이 나타나게 되고 이것은 합성된 막이 turbostratic BN (tBN) 형태를 가지고 있다는 것을 나타낸다. 50$0^{\circ}C$의 합성 온도에서 기판 bias가 -300V에서 hBN (002) peak이 관찰되었고, -500, -700 V에서는 hBN (100) peak만이 관찰되었다. 따라서 고온에서의 큰 ion bombardment는 합성되는 막의 결정성을 저해하는 요소로 작용한다는 것을 확인 할 수 있었다. 합성된 BN 막은 ball on disk type의 tribometer를 이용하여 마모 거동을 관찰한 결과 대부분 1이상의 매우 큰 friction coefficient를 나타내었고, nano-indenter로 측정한 BN막의 hardness는 매우 soft한 막에서부터 10 GPa 정도 까지의 값을 나타내었고, nano-indenter로 측정한 BN 막의 hardness는 매우 soft한 막에서부터 10GPa 정도 까지의 값을 가지며 변하였다. 합성된 BCN, Si-BCN 막은 FT-IR, Raman, S-ray, TEM 분석을 통하여 그 구조와 합성된 상에 관하여 분석하였다. FT-IR 분석을 통해 B-N 결합과 C-N 결합을 확인할 수 있었고, Raman 분석을 통하여 DLC의 특성을 분석하였다. 마모 거동에서는 BCN 막의 경우 0.6~0.8 정도의 friction coefficient를 나타내었고 Si-BCN 막은 0.3이하의 낮은 friction coefficient를 나타내었다. Hardness는 carbon의 함유량과 Ar 가스의 첨가 유무에 따라 각각을 측정하였고 이것은 BN 막 보다 향상된 값을 나타내었다.

  • PDF

The Clay Mineralogy of some Low Productive Paddy Soils In Kyonggi-Do (경기도(京畿道) 저위생산답(低位生産畓)의 점토광물(粘土鑛物)에 관(關)한 연구(硏究))

  • Shim, Sang Chil;Kim, Tai Soon;Lee, Hyung Koo;Song, Ki Joon;Valencia, I.G.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.7 no.3
    • /
    • pp.127-135
    • /
    • 1974
  • The samples were taken from the following localities previously classified as "Akiochi" area: Yangpyung, Puchun, and Pyungtaik, all of Kyonggi-do province. Five soil profiles were described in the field, and taken to the laboratory for physical and chemical analysis and mineralogical analysis by X-ray diffraction. The predominant clay minerals consist mainly of illite, vermiculite, chlorites and intergrade with vermiculite, and kaolinite. Illite or mica was found present in all samples and in all horizons. This was identified by the 9.83 to $10{\AA}$ (0.01) and $3.32{\AA}$ (003) basal reflections, Interhorizontal variations in mineral content and crystallinity are illustrated in their respective Xray diffractogram. Comparing the peak intensity, of the $14{\AA}$, $10{\AA}$ and $7{\AA}$ indicated the degree of weathering from the surface to the lower horizons. In general, the weathering of illite on the surface produced less pronounced $10{\AA}$ and $14{\AA}$ peak as compared to the lower horizons. The same may be said with kaolinite. On K-saturation, the $14{\AA}$ peak broadening on the low angle side was observed. This is interpreted to be due to chlorization. Heat treament from $100^{\circ}C$, $200^{\circ}C$, $400^{\circ}C$, $600^{\circ}C$, and $800^{\circ}C$. caused significant changes in the different diffractograms. Heating caused collasped of the $14{\AA}$ to $10{\AA}$ and the appearance of scattered peaks between $10-14{\AA}$. This is interpreted to the presence of vermiculite chlorite intergradient. The complete collapse of the $14{\AA}$ at $800^{\circ}C$ to $10{\AA}$ with increased intensity was attributed to the preservce of vermiculite. The principal difference among the clay minerals in each horizon is the concomitant increase and decrease in intensity with depth of the $14{\AA}$, $10{\AA}$ and $7{\AA}$ diffraction spacings. Apparently the weathering of illite ($10{\AA}$) is resulting in the formation of vermiculite ($14{\AA}$) and the interstratified material being an intermediate stage and the beginning of the formation of vermiculite. Some broadening- in the 17 to $18{\AA}$ was observed in Puchun-1 Pyungtaik-1 and Pyungtaik-2 specially so in the lower horizon in the Ca or Mg-saturated sample. Heated treatment tend to shift this peak to $14{\AA}$ indicating the presence of regular layering of the interstratified complex. The high amount of extractable aluminum and iron coupled with low exchange capacity indicate that iron and aluminum plays an important role in the weathering of these soils and is responsible to the low exchange capacity, high acidity and high phosphate absorptive capacity. The results presented substantiated the weathering sequence of Jackson in that mica ${\rightarrow}$ vermiculite ${\rightarrow}$ chloritezed vermiculite ${\rightarrow}$ kaolinite.

  • PDF

A Study on the Detection Ability of Minute Lesions in X-ray Using the Molybdenum Target (Molybdenum 저지극을 이용한 X-ray의 미세병소 검출능력에 관한 연구)

  • Yang, Da-Rae;Dong, Kyung-Rae;Park, Yong-Soon;Ji, Youn-Sang;Kim, Young-Keun;Kim, Chang-Bok
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.43-48
    • /
    • 2010
  • Beam quality is determined according to Xray tube's target material. In a range of between 22 kVp and 28 kVp, molybdenum target generates the characteristics energy between the average 17.9 kVp and 19.5 kVp, which produces the high contrast image of the breast. In this study, we used the Mo/Mo combination breast device and ALVIM TRM phantom and measured the detection ability of the minute lesion in the breast imaging throughout analyzing ROC curves. Assuming that an average subject thickness of the breast is 40 mm, the detection ability was not dependent on the kVp changes in a while dependent on both the mAs and thickness change. We can assure that it is not needed to increase the kVp for the imaging of breast which thickness is within the mean range of 40 mm.

Effects of Metal Ions Mole Ratio, pH and Heat Treatment Condition on the Magnetic Properties and Formation of Co-precipitated M-type Barium Ferrite Powders (공침법으로 합성한 바륨 페라이트(BaM)의 형성과 자기적 성질에 미치는 금속이온 몰 비 및 pH와 열처리 조건의 영향)

  • Baek, In-Seung;Nam, In-Tak
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.6
    • /
    • pp.209-215
    • /
    • 2009
  • M-type barium ferrite (BaFe12O19) powders were synthesized through the co-precipitation method. Starting material composition $Fe^{3+}:\;Ba^{2+}$ mole ratio was fixed as 8 and the relative amount of $Fe^{3+}$ and $Ba^{2+}$ was controlled. Structure and magnetic properties and powder morphology were investigated using XRD, SEM, VSM. Powder showing high coercivity and small magnetization was obtained at pH8 and $Fe_{3+}:\;Ba_{2+}$ of 12 : 1.5. Small magnetization value was originated from the existence of ${\alpha}-Fe_2O_3$. Single-phase Mtype barium ferrite were obtained regardless of the heat treatment condition and the amount of $Fe_{3+}\;and\;Ba_{2+}$ at pH$\approx$10. The largest value of magnetization (55.7 emu/g) under investigation were obtained when $Fe_{3+}:\;Ba_{2+}$ of 13.6 : 1.7 and furnace cooled powder in $O_2$. Particle size of powder was in the range of 50~200 nm.

Effect of Calcination Temperatures on the Structure and Electrochemical Characterization of Li(Ni0.5Mn0.3Co0.2)O2 as Cathode Material by Supercritical Hydrothermal Synthesis Method (초임계 수열법으로 합성한 Li(Ni0.5Mn0.3Co0.2)O2 양극 활물질의 소성 온도영향에 따른 구조 및 전기화학적 특성)

  • Choo, Soyeon;Beom, YunGyeong;Kim, Sungsu;Han, Kyooseung
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.3
    • /
    • pp.151-156
    • /
    • 2013
  • As the cathode material for li-ion battery, $LiNi_{0.5}Mn_{0.3}Co_{0.2}O_2$ were synthesized by supercritical hydrothermal method and calcined $850^{\circ}C$ and $900^{\circ}C$ for 10hrs in air. The effect of temperature in the heat treatment on the powder and its performance were studied of xray diffraction pattern, SEM-image, physical properties and electrochemical behaviors. As a result, calcined at $900^{\circ}C$ material particle size more increase than calcined at $850^{\circ}C$ material, especially shows excellent electrochemical performance with initial reversible specific capacity of 163.84 mAh/g (0.1C/2.0-4.3V), 186.87 mAh/g (0.1C/2.0-4.5V) and good capacity retention of 91.49% (0.2C/2.0-4.3V) and 90.36% (0.2C/2.0-4.5V) after 50th charge/discharge cycle.