Quantitative Analysis of X-Ray Fluorescence for Understanding the Effect of Elevated Temperatures on Cement Pastes (XRF (X-ray fluorescence)를 활용한 고온환경에 노출된 시멘트 페이스트 분석의 이해)

  • Kil-Song Jeon;Young-Sun Heo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.130-137
    • /
    • 2023
  • By using XRF (X-ray fluorescence), this study investigates the variation of chemical properties in cement pastes at elevated temperatures. High-temperature conditions were prepared by using an electric furnace, planning a total of 11 target temperatures ranging from room temperature to 1000 ℃. A standard library of geo-quant basic was applied for the analysis of 12 elements in cement paste, including Ca, Si, Al, Fe, S, Mg, Ti, Sr, P, Mn, Zn and K. The results revealed that, as the temperature increased, the proportion of each element in the cement paste also increased. With the exception of a few elements present in extremely low amounts in the cement pastes, the variation in the composition ratio of most elements exhibited a strong correlation with temperature, with an R-squared value exceeding 0.98. In this study, cement pastes exposed to normal and high-temperature environments were compared. The authors established that the reasons for the different results in this comparison can be explained from the same perspective as when comparing raw cement with cement paste. Furthermore, this study discussed the potentially most dominant parameter when investigating the properties of cement paste using XRF.

Research on Surface Contamination Analysis of Radiology Examination Equipment in Medical Institutions (의료기관 내 영상의학 검사 장비의 표면 오염도 분석 연구)

  • Shin-Woo Lee;Da-eun Kim;Chae-won Mun;Gap-Jung Kim;Sang-Ha Kim;Hye-mi Park;Se-Jong Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.171-177
    • /
    • 2024
  • In this study, two general X-ray device, CT, and MRI inspection devices were selected from general hospitals in the Daejeon area and an experiment was conducted to predict the level of infection by measuring the surface contamination of the inspection devices at different times and to use it as basic data for infection prevention. As a result, the surface contamination level by time zone for general X-ray devices and MRI examination devices was in the order of 13H > 8H > 16H, and for CT examination devices, it was 13H > 16H > 8H, which appeared to be influenced by the number of tests. In addition, the surface contamination results for each part of the test device showed that the highest ATP contamination value was found on the stand bucky handle for the general X-ray device, the headrest for the CT examination device, and the operation switch for the MRI examination device, which was closely related to the number of contacts. As a result of comparing before and after disinfection, all devices showed a significant decrease after disinfection. Based on the results of the experiment, it is believed that it can be used as basic data to identify the level of contamination in radiology laboratories and prevent infectious diseases.

High Resolution Computerized Tomography System Using the Microfocus X-Ray for Inspection of Small Specimens (소형 물체의 검사를 위한 고해상도 미세 초점 X선 단층 촬영 시스템)

  • Kim, Young-Joo;Koo, Ja-Yong;Lee, Seung-S.;Kim, Whan-W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.3
    • /
    • pp.181-190
    • /
    • 1998
  • A computerized tomography system was developed using the X-ray source that has diameter of 5 micrometer. The system is used for the nondestructive testing of specimens with diameter below 20 mm. The convolution back projection algorithm was adopted for the reconstruction of cross sectional image, and the shape of the X-ray beam was let parallel beam or fan beam to compare each resultant image. Our CT system was constructed to operate based on the personal computer. The sectional images of the fabricated specimens were reconstructed and analyzed. The reconstructed images well coincided with real images taken with optical microscope and gave us enough reports on the defects in the ceramic specimen. The resolution of the system regarded as about $20{\sim}30$ micrometers.

  • PDF

X-ray Image Processing for the Korea Red Ginseng Inner Hole Detection (II) - Results of inner hole detection - (홍삼 내공검출을 위한 X-선 영상처리기술 (II) - 내공검출결과 -)

  • 손재룡;최규홍;이강진;최동수;김기영
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.45-52
    • /
    • 2003
  • Red ginsengs are inspected manually by examining those in the dark room with back light illumination. Manual inspection is often influenced by physical condition of inspectors. Sometimes. the best grade, heaven. has some inner holes though it was inspected by a specialist. In order to resolve this problem, this study was performed to develop image processing algorithm to detect the inner holes in the x-ray image of ginseng. Because of little gray value difference between background and ginseng in the image. simple thresholding method was not appropriate. Modified watershed algorithm was used to differentiate the inner holes from background and normal ginseng body. Inner hole edge region detected by watershed algorithm consists of many number of blobs including normal portions. With line profile analysis with scanning one line at a time beginning the starting point. it shelved two peaks both ends representing extracting each blobs. in which setting threshold value as of lower peak value enabled us to obtain inner hole image. Once this procedure has to be done till the finishing point it is completing inner hole detection for one blob. Thus. conducting ail blobs by this procedure is completing inner detection of one whole ginseng. Detection results of the inner holes fer various size of red ginsengs were good even though there was small detection variation. 6.2%. according to position of x-rat tube.

The Numerical Phantom Design for Simulation of the Stereo X-ray Inspection System (스테레오 X-선 투시장치 전산 모사를 위한 수치적 팬텀 설계)

  • Hwang, Young-Gwan;Lee, Seung-Wook;Lee, Nam-Ho;Moon, Myung-Kook
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1915_1916
    • /
    • 2009
  • 스테레오 X-선 영상시스템 개발을 위하여 수치적 프로젝션을 획득하는 방법론 및 수치적 팬텀 영상을 고안하고 시험하였다. 오픈소스인 TAKE21을 사용하여 수치적 팬텀을 설계하고 그로부터 프로젝션 이미지를 획득하였다. 스테레오 영상을 위한 평행 원근 투영(Parallel-Perspective) 기하구조에 대한 스테레오 프로젝션 영상을 얻기 위해서 계측기의 계와 선원의 위치에 대해 동차 좌표계(Homogeneous coordinate)에서의 선형변환(Linear Transform)을 적용되는 방식을 이용하였다. 이러한 시뮬레이션은 스테레오 X-선 검색 장치의 설계 및 알고리즘 개발에 유용하게 사용될 수 있을 것이다.

  • PDF

Development of End-milling Inspection System Using 450kVp Tube Voltage (450kVp Tube Voltage를 이용한 엔드밀링 검색 시스템 개발)

  • Yoon, Moon-Chul;Jung, Jin-Seok;Hwang, In-Ho;Yuk, Sun-Woo;Park, Su-Kang;Chin, Do-Hun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.2
    • /
    • pp.10-17
    • /
    • 2009
  • Transillumination system used by radiation is widely applied to industrial imaging system. In this study, the linear detector array constructed with scintillator and pin diode, and a multi-channel data acquisition system was developed for precision inspection of end-milling. The detector module consists of $16-CdWO_4$crystal scintillator and photodiode array. The detector and data acquisition system was applied to precision inspection of end-mill and the images of the end-mill were successfully reconstructed. The total system can analyze the Detector Quantum Efficiency(DQE) of each system. The performance of developed photodiodes equipment was compared with each other for different crystal geometry and its characteristics. Finally fine details of the end-mill phantom were constructed for industrial application. The image acquired contains several objects on a real time data transfer and the linear X-ray scanning system can be applied to many fields of a industry.

  • PDF

Development of Agricultural Products Screening System through X-ray Density Analysis

  • Eunhyeok Baek;Young-Tae Kwak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.4
    • /
    • pp.105-112
    • /
    • 2023
  • In this paper, we propose a new method for displaying colored defects by measuring the relative density with the wide-area and local densities of X-ray. The relative density of one pixel represents a relative difference from the surrounding pixels, and we also suggest a colorization of X-ray images representing these pixels as normal and defective. The traditional method mainly inspects materials such as plastics and metals, which have large differences in transmittance to the object. Our proposed method can be used to detect defects such as sprouts or holes in images obtained by an inspection machine that detects X-rays. In the experiment, the products that could not be seen with the naked eye were colored with pests or sprouts in a specific color so that they could be used in the agricultural product selection system. Products that are uniformly filled with a single ingredient inside, such as potatoes, carrots, and apples, can be detected effectively. However, it does not work well with bumpy products, such as peppers and paprika. The advantage of this method is that, unlike machine learning, it doesn't require large amounts of data. The proposed method could be applied to a screening system using X-rays and used not only in agricultural product screening systems but also in manufacturing processes such as processed food and parts manufacturing, so that it can be actively used to select defective products.

Corrosion Failure Analysis of the Convection Part of District Heating Peak Load Boiler (지역난방 첨두부하보일러 대류부 부식 파손 분석)

  • Kim, Youngsu;Chae, Hobyung;Hong, Minki;Song, Min Ji;Cho, Jeongmin;Kim, Woo Cheol;Ha, Tae Baek;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.55-60
    • /
    • 2019
  • Corrosion failure in the convection part of peak load boiler (PLB) of the district heating system led to water leakage. Herein, Internal Rotary Inspection System (IRIS) inspection was employed to examine wall thinning and the cause of leakage in the flue tube. The corrosive products of the turbulator and tube were investigated using scanning electron microscope combined with energy dispersive spectroscopy, X-ray diffraction, and inductively coupled plasma (ICP). Majority of the serious corrosion damage was observed near the turbulator located in the upper flue tube. ICP analysis of the boiler water revealed oxide formation of sodium chloride in the lower end part of the flue tube. A cross-sectional view of the turbulator revealed the presence of double-layers of the oxide film, indicating environmental change during operation associated with water leakage. The outer surface of the turbulator consisted of the acid oxides such as $NO_x$ and $SO_x$ along with sodium and chloride ions. Dew-point corrosion is hypothesized as the main cause for the formation of acid oxides in the region of contact of the flue tube and the turbulator.

The Reliability Test of Sealing Glass Frit in AC PDP

  • Jeon, Young-Hwan;Hwang, Jong-Hee;Lim, Tae-Young;Kim, Hyung-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1538-1541
    • /
    • 2005
  • For reliability evaluation of AC-PDP, one of the most important factor is sealing property. In this paper, the reliability evaluation test method of the commercialized sealing glass frit in AC-PDP was studied. 6 inch AC-PDP panels were tested for evaluation of sealing glass frit by vibration shock test, thermal shock test, non -destructive X-ray inspection, residual stress inspection and residual gas detection. These test methods are proposed as a standard for testing the reliability of sealing glass frit. The main failure mode of sealing glass frit in AC-PDP seems to be the crack propagation from thermal cycling rather than mechanical factor.

  • PDF

A Study on the Radiograph Inspection of Specimen in Welding Pass Using ATOS 80 High-strength Steel (ATOS 80 고장력강의 용접 패스에 따른 용접부 방사선검사에 관한 연구)

  • Baek, Jung-Hwan;Choi, Byung-Ky
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.6
    • /
    • pp.915-919
    • /
    • 2012
  • In constructing all kinds of equipment and steel structure, parts with discontinuities such as weld defects formed in the welded structure can generate fatigue cracks that results in damage or accidents. In this study, weld zones are investigated with X-rays and the latent images are put on film. Weld zone defects can be verified by developing the film. As weld defects are investigated by radiographic testing and correlated with the welding condition, more appropriate welding conditions can be found. According to the result of X-ray radiographic inspection of butt welding ATOS 80 high-strength steel with a thickness of 12mm, the best conditions for welding without creating weld defects are 4 weld-passes, a protective gas of 20% $CO_2$ and 80% Ar, a protective gas flow of 20L/min, a welding current of 200A, an arc voltage of 24V, a welding speed of 14.4cm/min, a welding rod angle of $50^{\circ}$, a welding gap of 5 mm with a ceramic base, and sand pre-heating to $160^{\circ}$ Celsius prior to welding.